Search NASA⌕ Search

SEARCH · Search NASA

Results for “sources molecular spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Walls and windows in the molecular Milky Way

Estimates are presented of the distances to the nearest CO-emitting material along 31,500 lines of sight in the northern Milky Way on the basis of an analysis of the Massachusetts-Stony Brook survey of CO emission in the first Galactic quadrant. For Galactic latitudes between -1.0 and +1.0 deg and longitudes between 8 and 53 deg, significant CO emission (greater than 1.2 K) and associated optical obscuration (greater than 1.2 mag) is found within 2 kpc of the sun in 21,149 of the lines of sight. Much of this local emission is associated with the Aquila Rift system of dark clouds. Another 8,179 lines of sight are obscured at distances between 2 and 10 kpc. The remaining 2,172 lines of sight are completely free of significant CO emission. These cloud-free positions can be used as 'offs' for radio or IR spectroscopy of molecular sources in the Galactic plane, as 'ons' for studies of the diffuse intercloud medium itself, and as possible 'windows', through which distant disk and bulge stars might be optically observable.

Waller, William H.↗

The 1.5 - 3.5 Micron Spectroscopy of the Orion H2 Source

A synopsis of current research with near infrared airborne spectroscopy of the Orion molecular hydrogen emission line source is presented. It is suggested that (H2) is the most abundant molecular species in the interstellar medium and is of paramount importance to understand its behavior and distribution in that medium. The H2 has no permanent electric dipole moment which precludes dipole transitions. It is, however, detected in absorption against background starlight by UV electronic transitions and in the IR through electric quadrupole rotation/vibration and pure rotation emission lines. The physical parameters of this region, in the context of their relationships to other members of the complex family of Orion objects, molecular clouds, compact IR sources, H 2 regions, and shock fronts are described.

Davis, D. S.↗

Tunable Electro-optic modulators for lidar systems and atmospheric applications

In global sensing applications using different types of lidars, the spectral range and fine frequency coverages are often limited because of the finite tunabilities of molecular lasers and the number of molecular species that are available. To overcome the above obstacle, we have proposed new broadband frequency tunable electro-optic (EO) modulators that can cover a wide range from the mid-infrared to the visible as lidar sources in atmospheric sensing applications such as high resolution atmospheric molecular spectroscopy, Differential Absorption Lidar (DIAL), and laser radar imaging. The configuration of the proposed new tunable EO modulators includes an electro-optic active crystal element surrounded by a ferrite tuning element which is placed inside a microwave waveguide. The tuning is provided by an external magnetic field, which is either longitudinal or transverse, and the modulator can be either single sideband type or a double sideband type depending on the application required for the spectral purity of the modulator output.

Eng, R. S.↗

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank↗

Ultra high resolution molecular beam cars spectroscopy with application to planetary atmospheric molecules

The measurement of high resolution pulsed and continuous wave (CW) coherent anti-Stokes Raman spectroscopy (CARS) measurements in pulsed and steady state supersonic expansions were demonstrated. Pulsed molecular beam sources were characterized, and saturation of a Raman transition and, for the first time, the Raman spectrum of a complex molecular cluster were observed. The observation of CW CARS spectra in a molecular expansion and the effects of transit time broadening is described. Supersonic expansion is established as a viable technique for high resolution Raman spectroscopy of cold molecules with resolutions of 100 MH2.

Byer, R. L.↗

Optical signatures of molecular particles via mass-selected cluster spectroscopy

A new molecular beam apparatus was developed to study optical absorption in cold (less than 100 K) atomic clusters and complexes produced by their condensation with simple molecular gases. In this instrument, ionized clusters produced in a laser vaporization nozzle source are mass selected and studied with photodissociation spectroscopy at visible and ultraviolet wavelengths. This new approach can be applied to synthesize and characterize numerous particulates and weakly bound complexes expected in planetary atmospheres and in comets.

Duncan, Michael A.↗

A Census of Stars and Disks in Corona Australis

We have performed a census of the young stellar populations near the Corona Australis molecular cloud using photometric and kinematic data from several sources, particularly Gaia EDR3, and spectroscopy of hundreds of candidate members. We have compiled a catalog of 393 members of Corona Australis, (39 at >M6), 293 (36) of which are spectroscopically classified for the first time in this work. We find that Corona Australis can be described in terms of two stellar populations, a younger one (a few megayears) that is partially embedded in the cloud (the Coronet Cluster) and an older one (∼15 Myr) that surrounds and extends beyond the cloud (Upper Corona Australis). These populations exhibit similar space velocities, and we find no evidence for distinct kinematic populations in Corona Australis, in contrast to a recent study based on Gaia DR2. The distribution of spectral types in Corona Australis reaches a maximum at M5 (∼0.15 M⊙), indicating that the initial mass function has a similar characteristic mass as other nearby star-forming regions. Finally, we have compiled mid-infrared photometry from the Wide-field Infrared Survey Explorer and the Spitzer Space Telescope for the members of Corona Australis, and we have used those data to identify and classify their circumstellar disks. Excesses are detected for 122 stars, one-third of which are reported for the first time in this work.

T L Esplin↗

Micro Raman Spectroscopy for Characterizing Molecular Contamination on Space Flight Hardware

In the field of contamination control,many unknowns exist. Often, contamination control engineers have to utilize multiple spectroscopic, macroscopic, and microscopic tools to identify contamination sources when there is a potential contamination exposure to space flight hardware. Understanding the chemical composition of the molecular contamination provides an opportunity for contamination control engineers to determine if this contamination is problematic or benign. In this study, an existing witness plate program for monitoring space flight hardware during the assembly, integration, and testing phases is coupled with micro Raman spectroscopy analysis. The main goal of this study is to determine the limitations, reproducibility, and throughput of micro Raman spectroscopy for characterizing molecular contamination. Micro Raman Spectroscopy will be an additional tool used by contamination control engineers to monitor the cleanliness of space flight hardware.

Microscope↗

Heterodyne Spectroscopy in the Thermal Infrared Region: A Window on Physics and Chemistry

The thermal infrared region contains molecular bands of many of the most important species in gaseous astronomical sources. True shapes and frequencies of emission and absorption spectral lines from these constituents of planetary and stellar atmospheres contain unique information on local temperature and abundance distribution, non-thermal effects, composition, local dynamics and winds. Heterodyne spectroscopy in the thermal infrared can remotely measure true line shapes in relatively cool and thin regions and enable the retrieval of detailed information about local physics and chemistry. The concept and techniques for heterodyne detection will be discussed including examples of thermal infrared photomixers and instrumentation used in studies of several astronomical sources. Use of heterodyne detection to study non-LTE phenomena, planetary aurora, minor planetary species and gas velocities (winds) will be discussed. A discussion of future technological developments and relation to space flight missions will be addressed.

Kostiuk, Theodor↗

Tunable diode laser Stark modulation spectroscopy for rotational assignment of the HNO3 7.5-micron band

The technique of Stark modulation spectroscopy for unraveling and assigning rotationally resolved dense molecular spectra has been employed using a tunable diode laser (TDL) source. Doppler-limited absorption and Stark modulation spectra of the HNO3 7.5-micron band near the 1326/cm band origin are presented with preliminary values of the excited-state rovibrational constants derived from both TDL and Bomem Fourier transform IR spectra.

Webster, C. R.↗

Ultraviolet absorption: Experiment MA-059

A technique devised to permit the measurement of atmospheric species concentrations is described. This technique involves the application of atomic absorption spectroscopy and the quantitative observation of resonance fluorescence in which atomic or molecular species scatter resonance radiation from a light source into a detector. A beam of atomic oxygen and atomic nitrogen resonance radiation, strong unabsorbable oxygen and nitrogen radiation, and visual radiation was sent from Apollo to Soyuz. The density of atomic oxygen and atomic nitrogen between the two spacecraft was measured by observing the amount of resonance radiation absorbed when the line joining Apollo and Soyuz was perpendicular to their velocity with respect to the ambient atmosphere. Results of postflight analysis of the resonance fluorescence data are discussed.

Donahue, T. M.↗

Vibrational Spectroscopy after OSU - From C2- to Interstellar Polycyclic Aromatic Hydrocarbons

The composition of interstellar ice and dust provides insight into the chemical history of the interstellar medium and early solar system. It is now possible to probe this unique and unusual chemistry and determine the composition of these microscopic interstellar particles which are hundreds to many thousands of light years away thanks to substantial progress in two areas: astronomical spectroscopic techniques in the middle-infrared, the spectral region most diagnostic of chemical composition, and laboratory simulations which realistically reproduce the critical conditions in various interstellar environments. High quality infrared spectra of many different astronomical sources, some associated with giant, dark molecular clouds -the birthplace of stars and planets- and others in more tenuous, UV radiation rich regions are now available. The fundamentals of IR spectroscopy and what comparisons of astronomical IR spectra with laboratory spectra of materials prepared under realistic simulated interstellar conditions tell us about the components of these materials is the subject of this talk. These observations have shown that mixed molecular ices comprised of H2O, CH3OH, CO, NH3 and H2CO contain most of the molecular material in molecular clouds and that gas phase, ionized polycyclic aromatic hydrocarbons (PAHs) are widespread and surprisingly abundant throughout most of the interstellar medium.

Allamandola, Louis J.↗

Slow-Positron Generator For Studying Polymer Films

Aspects of molecular structures probed by positron-annihilation spectroscopy (PAS). Slow-positron-beam generator suitable for PAS measurements in thin polymer films. Includes Na22 source of positrons and two moderators made of well-annealed tungsten foil. With proper choice of voltage, positrons emitted by inward-facing surfaces of moderators made to stop in polymer films tested.

Singh, Jag J.↗

Tunable far infrared laser spectrometers

The state of the art in far infrared (FIR) spectroscopy is reviewed. The development of tunable, coherent FIR radiation sources is discussed. Applications of tunable FIR laser spectrometers for measurement of rotational spectra and dipole moments of molecular ions and free radicals, vibration-rotation-tunneling spectra of weakly bound complexes, and vibration-rotation spectra of linear carbon clusters are presented. A detailed description of the Berkeley tunable FIR laser spectrometers is presented.

Blake, G. A.↗

A 100 microsec, reliable, 10 Hz pulsed supersonic molecular beam source

A 10-Hz repetition rate, 100-microsec duration, reliable pulsed supersonic molecular beam source is described. Mechanical and electrical design of the pulsed valve are given in detail. Characteristics of the supersonic expansion obtained using coherent anti-Stokes Raman spectroscopy in acetylene are presented. They include pulse shape, gas rotational and translational cooling as a function of distance from the nozzle, clustering effects, and shock heating at the leading edge of the pulse.

Byer, R. L.↗

An IRAS survey of the Taurus-Auriga molecular cloud

IRAS data are used to search for young premain-sequence stars not previously associated with molecular cloud cores in the Taurus-Auriga region. NIR photometry and optical spectroscopy suggest that many of the objects are young stars. The sample includes six new embedded sources with luminosities comparable to that of the average T Tauri star, suggesting that surveys for premain-sequence stars in the cloud are essentially complete for luminosities greater than 0.5 solar luminosities. A disagreement is found between accretion rates derived from the duration of the embedded phase and those derived from the bolometric luminosity. It is found that this disagreement may be reconciled if a star accretes most of its mass in a time that is short compared to the duration of the embedded phase or if the ages of T Tauri stars have been underestimated.

Kenyon, Scott J.↗