Search NASA⌕ Search

SEARCH · Search NASA

Results for “space conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Quantum Condition Space

Abstract The fundamental properties of quantum physics are exploited to evaluate event probabilities with projection measurements. Next, to study what events can be specified by quantum methods, the concept of the condition space is introduced, which is found to be the dual space of the classical outcome space of bit strings. Like the classical outcome space generates the quantum state space, the condition space generates the quantum condition space being the central idea of this work. The quantum condition space permits the existence of entangled conditions having no classical equivalent. In addition, the quantum condition space is related to the quantum state space by a Fourier transform guaranteed by the Pontryagin duality, and therefore an entropic uncertainty principle can be defined. The quantum condition space offers a novel perspective of understanding quantum states with the duality picture. Furthermore, the quantum conditions have physical meanings and realizations of their own and thus may be studied for purposes beyond the original motivation of characterizing events for probability evaluation. Finally, the relation between the condition space and quantum circuits provides insights into how quantum states are collectively modified by quantum gates, which may lead to deeper understanding of the complexity of quantum circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

In cooperation with the Building America Program, The Levy Partnership explored a variety of options to reduce space-conditioning energy consumption, working with partners to design, manu- facture, and build test homes in three states. The Levy Partnership tested the use of minisplit ductless heat pumps in combi- nation with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The team set out to achieve 50% less energy consumption, compared to the 2009 International Energy Conservation Code, while maintaining home afford- ability and thermal comfort. The strategy also included a highly efficient thermal envelope to reduce space-conditioning loads.

30 DIRECT ENERGY CONVERSION↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space conditioning loads.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space-conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code (ICC 2009) while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space-conditioning loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Ducts in Conditioned Space

As codes push for greater energy savings, production homebuilders must consider ways to reduce the energy use associated with HVAC system performance. One prominent and effective approach to reduce energy use is the transition of ductwork from unconditioned space (attics, crawlspaces, basements) into conditioned space.

Building America↗

RENEWABLE MARINE-SOURCE INTEGRATED HEAT PUMP FOR SPACE CONDITIONING, WATER HEATING, AND FRESH WATER HARVESTING IN REMOTE COASTAL AND ISLAND COMMUNITIES

US coastal and island communities have vulnerable energy infrastructure and high energy costs, which are exacerbated by climate change. A unique opportunity exists to use thermal energy from year-round mild temperature variations to satisfy the broad energy needs of these communities. The US Department of Energy’s Oak Ridge National Laboratory designed a small-scale marine-source integrated heat pump (MS-IHP) that, as a single appliance, combines space conditioning, dehumidification (including fresh water harvesting from humid air), and water heating for home and commercial building applications in remote coastal and island communities. The unique, innovative features of the MS-IHP offer improved efficiency and substantially reduced costs for space conditioning, dehumidification, and water heating by seamlessly integrating a heat pump, heat pump water heater, and dehumidifier by using a single compressor; optimal year-round space cooling and heating, dehumidification, water harvesting, and water heating; and improved thermal comfort and reliable operation without frosting and defrosting because of the ocean’s warm temperatures and high heat capacity. Preliminary testing was conducted by retrofitting a commercial heat pump, demonstrating an outperformed performance compared with traditional air-source heat pumps. The MS-IHP technology can help decarbonize energy systems in remote coastal and island communities.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Novel Modular Residential CCHP for Space Conditioning and Water Heating

This presentation will first describe the design of a novel modular residential cold-climate heat pump for both space conditioning and water heating that can be coupled with thermal energy storage (TES) to maximize system efficiency and load flexibility. Among some of the novel operating modes of the proposed design include: 1) simultaneous outdoor coil defrost while still providing space heating or water heating; 2) simultaneous water heating and space cooling 3) using the TES as the heat source during cold climate operation to improve efficiency and 4) compressorless charging of the TES module during days with high temperature swings between night and day. Then, initial simulation results will be presented describing system performance in key operating modes in climate region 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Timed to save: the added value of accounting for hourly incidence of electricity savings from residential space-conditioning measures

Abstract Previous research has recognized that the value of measures that reduce electricity usage depends upon the timing of the savings generated, but the lack of hourly savings shapes has limited the demonstration of this concept. We develop empirical hourly savings shapes for residential space-conditioning measures from nearly 18,000 efficiency projects in California and show how they combine with the diurnal and seasonal variation in electricity system costs. We find that these measures (cooling replacements; windows, doors, and skylights; and other envelope measures) tend to save electricity when system costs are highest and that the hourly savings account for 1.4–1.5 times as much value as non-time-sensitive estimates of efficiency would predict. We present these impact multipliers for each measure to quantify the additional value revealed by the time-sensitive approach. We show that this additional value is similar in an evolving electricity grid with storage, rather than natural gas generation, as the marginal resource.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

The Hydrofluorocarbon Phasedown and Commercial Space Conditioning: A Guide to the Transition

You may be aware of the hydrofluorocarbon (HFC) phasedown, but the details and its impact on your operations may still be unclear. Or perhaps this is the first you're hearing about the phasedown. In either case, this guide provides information to aid conversations with facility managers and engineers and provides an explanation of how the phasedown affects equipment in commercial buildings. It also includes actions you and your organization can take now to properly plan and prepare.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lab Evaluation of Downward Capacity of Radiant Ceiling Panel Systems

This project investigated the cooling delivery effectiveness of radiant ceiling panels as a function of attic insulation level using multiple laboratory testing and analytical methodologies. Delivery effectiveness is the heating or cooling energy delivered to a conditioned space divided by the total heating or cooling energy added or removed by the space conditioning system. The lower the losses of the heating or cooling delivery method, the higher the delivery effectiveness. For ducted systems, delivery effectiveness is reduced by both air leakage and thermal losses (especially if the ducts are installed in attics), while the delivery effectiveness of a radiant system supplied by hot and cold water is only reduced by thermal losses, which can be mitigated by sufficient insulation above, or at the "back" of the panel. Being installed at or below the ceiling plane, sufficient back insulation should be provided by default in the form of the attic insulation above the radiant ceiling panels. Site-built radiant ceiling panels were evaluated at Frontier Energy’s Building Science Research Laboratory (BSRL) in a uniquely designed environmental test chamber with independently controllable indoor and attic spaces and a height-adjustable ceiling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Numerical Modelling Study on Submerged Condensers for Heat Pump Water Heaters Using Low-GWP Refrigerants

Challenges to global warming require reduction of GHG emissions, and increased use of renewable energy. Heat pumps extract energy from renewable sources and convert them to more useable forms for space conditioning, space heating and for water heating. They can be powered by renewable sources of electricity and must be engineered to use low global warming potentials (GWP) refrigerants (e.g., propane, GWP = 3) for a sustainable economy. Therefore, an electric heat pump water heaters (HPWH) using propane as refrigerant are developed in Oak Ridge National Laboratory to replace water heaters using all electric resistance and natural gas. A submerged condenser directly contacting with water is employed in the HPWH, which eliminates heat transfer barrier of the tank wall, and also prevents heat loss from the condenser tubes to the surrounding air. In present work, a numerical model is developed to model the submerged condenser. A dynamic temperature distribution on the condenser tubes from experimental data is applied to the model to enhance the accuracy of the numerical model. The model is essential to guide the design of the submerged condenser to achieve the performance required by the HPWH.

Zhang, Mingkan↗

Predicting industrial building energy consumption with statistical and machine-learning models informed by physical system parameters

The industrial sector consumes about one-third of global energy, making them a frequent target for energy use reduction. Variation in energy usage is observed with weather conditions, as space conditioning needs to change seasonally, and with production, energy-using equipment is directly tied to production rate. Previous models were based on engineering analyses of equipment and relied on site-specific details. Others consisted of single-variable regressors that did not capture all contributions to energy consumption. Further, new modeling techniques could be applied to rectify these weaknesses. Applying data from 45 different manufacturing plants obtained from industrial energy audits, a supervised machine-learning model is developed to create a general predictor for industrial building energy consumption. The model uses features of air enthalpy, solar radiation, and wind speed to predict weather-dependency; motor, steam, and compressed air system parameters to capture support equipment contributions; and operating schedule, production rate, number of employees, and floor area to determine production-dependency. Results showed that a model that used a linear regressor over a transformed feature space could outperform a support vector machine and utilize features more representative of physical systems. Using informed parameters to build a reliable predictor will more accurately characterize a manufacturing facility's energy savings opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online Calculator to Evaluate the Impact of Airtightness on Residential Building Energy Consumption and Moisture Transfer

Energy consumption in residential buildings is primarily driven by space conditioning applications. Space heating and cooling, on average, consume approximately 50% of the energy in the residential buildings in the U.S. The primary energy use due to infiltration is more than 2.8 Quads, which is 29% of primary energy consumption attributable to fenestration and building envelope components in residential buildings in US in 2010. There are advanced air barrier technologies and construction practices to reduce air leakage in buildings, which are currently available in the market. However, the lack of adequate information on their impact on energy consumption and the durability of buildings has caused the slow adoption of these technologies and methods. In the past, the authors developed an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in airtightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations, given that air leakage through the building envelope can have a significant impact on moisture transfer. The calculator is again being expanded by adding residential and additional commercial building data. In this paper, we present the impact of airtightness in residential buildings on energy consumption and moisture transfer. The study includes the analysis of airtightness in 52 major cities in the U.S. and five cities in Canada on a residential building that includes a crawlspace and has a gas furnace.

Kunwar, Niraj↗

Effect of the space weather conditions on the Earth magnetosphere soft X-ray emissivity

The aim of the study is to model and characterize the soft X-ray emissivity on the Earth magnetosphere for different space weather conditions (SWC), providing information to interpret the soft X-ray measurements of the Solar wind Magnetosphere Ionosphere Link Explorer space mission. The MHD code pluto in spherical coordinates is used to perform parametric studies with respect to the solar wind (SW) dynamic pressure (considering density and velocity effects independently) as well as the IMF intensity and orientation, predicting the soft X-ray emissivity for different SWC. The integrated soft X-ray emissivity inside the magnetosheath is calculated as a proxy of the soft X-ray emission dependencies with the SWC independently of the satellite orbit and camera line of sight. The analysis indicates fluctuations of the interplanetary magnetic field (IMF) orientation and magnitude may significantly affect the measured soft X-ray emission although changes in the SW dynamic pressure should be the main source of variability. The southward IMF orientation leads to the configuration with the largest soft X-ray emissivity and northward to the lowest. Strongly distorted magnetospheres explored in configurations showing SW and IMF parameters comparable to the impact of interplanetary coronal mass ejections may show a decrease of the soft X-ray emissivity as the IMF magnitude increases, explained by the strong magnetosphere compression and constriction of the magnetosheath region where the soft X-ray emissivity maximum is located. The simulations also indicate large excursions of the soft X-ray emissivity maximum inside the magnetosheath as the IMF magnitude and SW dynamic pressure fluctuate particularly for radial and ecliptic IMF orientations.

Earth↗

An Integrated Control Method for Supplemental Minisplit Heat Pumps in Existing Homes

The FSEC Energy Research Center(FSEC) at the University of Central Florida has investigated low-cost space-conditioning upgrade solutions for existing homes since 2014. The retrofits involve installing a modest capacity, centrally located, high efficiency, ductless, minisplit heat pump (MSHP) for use in conjunction with the home’s existing central space conditioning system (CSCS). This type of retrofit targets homes with older but not obsolete CSCSs that have not reached end of life, and presents a more cost-effective option to achieve space conditioning energy savings than outright CSCS replacement. This report describes results from investigating the energy savings potential, given adherence to comfort management, if the control of the MSHP and CSCS were integrated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗