Search NASA⌕ Search

SEARCH · Search NASA

Results for “space fire safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Boiling Transitions During Droplet Contact on Superheated Nano/Micro-Structured Surfaces

Manipulating surface topography is one of the most promising strategies for increasing the efficiency of numerous industrial processes involving droplet contact with superheated surfaces. In such scenarios, the droplets may immediately boil upon contact, splash and boil, or could levitate on their own vapor in the Leidenfrost state. In this work we report the outcomes of water droplets coming in gentle contact with designed nano/micro-textured surfaces at a wide range of temperatures as observed using high-speed optical and X-ray imaging. Further, we report a paradoxical increase in the Leidenfrost temperature ($T_{\text{LFP}}$) as the texture spacing is reduced below a critical value (~10 μm) that represents a minima in $T_{\text{LFP}}$. Although droplets on such textured solids appear to boil upon contact, our studies suggest that their behavior is dominated by hydrodynamic instabilities implying that the increase in $T_{\text{LFP}}$ may not necessarily lead to enhanced heat transfer. On such surfaces, the droplets display a new regime characterized by splashing accompanied by a vapor jet penetrating through the droplets before they transition to the Leidenfrost state. We provide a comprehensive map of boiling behavior of droplets over a wide range of texture spacings that may have significant implications towards applications such as electronics cooling, spray cooling, nuclear reactor safety and containment of fire calamities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Root traits reveal safety and efficiency differences in grasses and shrubs exposed to different fire regimes

Plant roots are important components of terrestrial ecosystems, but little is known about how root traits differ between plant species or vary across space in natural ecosystems. In this study, we investigated how root traits vary across grasses and woody shrubs in a tallgrass prairie located in Manhattan, KS, USA. Specifically, were interested in understanding how anatomical traits vary across these different plant groups, across different depths in the soil, and also across multiple areas of tallgrass prairie that are burned at different frequencies. We compared traits that allow roots to use soil water efficiently and those that help roots persist through extended periods of drought. We found that woody roots exhibited traits that allow them to use water efficiently in shallow soils but persist through drought in deeper soil. Here, these traits may allow shrubs to transport water from shallow soils to deeper soil after large rain events and resist extended periods without rain when soils become dry, which may allow woody plants to successfully compete for water in less frequently burned, more diverse plant communities. Grasses had traits that allow them to use water efficiently but also tolerate drought in shallow soils, regardless of fire treatment. This unique trait combination likely gives grasses a competitive advantage over other tallgrass prairie plants across different fire regimes. Together, these results show that anatomical root traits can be used to enhance mechanistic understanding of plant functioning in dynamic ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen Refueling Reference Station Lot Size Analysis for Urban Sites

Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) is a project initiated by the DOE in 2015 and executed by Sandia National Laboratories and the National Renewable Energy Laboratory to address R&D barriers to the deployment of hydrogen fueling infrastructure. One key barrier to the deployment of fueling stations is the land area they require (i.e. "footprint"). Space is particularly a constraint in dense urban areas where hydrogen demand is high but space for fueling stations is limited. This work presents current fire code requirements that inform station footprint, then identifies and quantifies opportunities to reduce footprint without altering the safety profile of fueling stations. Opportunities analyzed include potential new methods of hydrogen delivery, as well as alternative placements of station technologies (i.e. rooftop/underground fuel storage). As interest in heavy-duty fueling stations and other markets for hydrogen grows, this study can inform techniques to reduce the footprint of heavy-duty stations as well. This work characterizes generic designs for stations with a capacity of 600 kg/day hydrogen dispensed and 4 dispenser hoses. Three base case designs (delivered gas, delivered liquid, and on-site electrolysis production) have been modified in 5 different ways to study the impacts of recently released fire code changes, colocation with gasoline refueling, alternate delivery assumptions, underground storage of hydrogen, and rooftop storage of hydrogen, resulting in a total of 32 different station designs. The footprints of the base case stations range from 13,000 to 21,000 ft 2 . A significant focus of this study is the NFPA 2 requirements, especially the prescribed setback distances for bulk gaseous or liquid hydrogen storage. While the prescribed distances are large in some cases, these setback distances are found to have a nuanced impact on station lot size; considerations of the delivery truck path, traffic flow, parking, and convenience store location are also important. Station designs that utilize underground and rooftop storage can reduce footprint but may not be practical or economical. For example, burying hydrogen storage tanks underground can reduce footprint, but the cost savings they enable depend on the cost of burial and the cost land. Siting and economic analysis of station lot sizes illustrate the benefit of smaller station footprints in the flexibility and cost savings they can provide. This study can be used as a reference that provides examples of the key design differences that fueling stations can incorporate, the approximate sizes of generic station lots, and considerations that might be unique to particular designs.

08 HYDROGEN↗

Accurate Compression of Tabulated Chemistry Models with Partition of Unity Networks

Tabulated chemistry models are widely used to simulate large-scale turbulent fires in applications including energy generation and fire safety. Tabulation via piecewise Cartesian interpolation suffers from the curse-of-dimensionality, leading to a prohibitive exponential growth in parameters and memory usage as more dimensions are considered. Artificial neural networks (ANNs) have attracted attention for constructing surrogates for chemistry models due to their ability to perform high-dimensional approximation. However, due to well-known pathologies regarding the realization of suboptimal local minima during training, in practice they do not converge and provide unreliable accuracy. Partition of unity networks (POUnets) are a recently introduced family of ANNs which preserve notions of convergence while performing high-dimensional approximation, discovering a mesh-free partition of space which may be used to perform optimal polynomial approximation. In this work, we assess their performance with respect to accuracy and model complexity in reconstructing unstructured flamelet data representative of nonadiabatic pool fire models. Our results show that POUnets can provide the desirable accuracy of classical spline-based interpolants with the low memory footprint of traditional ANNs while converging faster to significantly lower errors than ANNs. For example, we observe POUnets obtaining target accuracies in two dimensions with 40 to 50 times less memory and roughly double the compression in three dimensions. We also address the practical matter of efficiently training accurate POUnets by studying convergence over key hyperparameters, the impact of partition/basis formulation, and the sensitivity to initialization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation Hardened Foam Cold Test Plan – Phase-I: Foam Adhesion, Contamination Fixation, Moisture Stresses, Pipe Cutting, and Thermal Profile Testing

This document outlines the Phase-I test objectives and implementation plan for a down-selective foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of an intumescent, fire-retardant foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed in FIU’s Outdoor Test and Evaluation Facility using a mock-up that replicates the operational conditions at the proposed hot test location at F/H labs. Results from the cold test plan will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the site and transported to a proper disposal facility. Phase-I testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of foam fixative in piping, (2) evaluation of the adhesion of the foam fixative in piping under varying moisture conditions, (3) determination of the heat profile of the foam fixative during curing, (4) determination of the relationship between pipe diameter and foam fixative quantity, (5) determination of the internal pipe pressure after foam deployment and curing, (6) development of a leak test standard operating procedure to test for the effectiveness of the foam plug, (7) initiation of a literature review to determine if using a hot tap is a viable method to deliver foam into piping, and (8) initiation of a 10-foot mock up test that will be used in Phase-II cold testing. The cold test will be conducted at FIU and all testing activities will comply with SRNL Conduct of R&D Protocols (SRNL-IM-2020-00019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Foaming Solutions for High Level Waste (HLW) Processing - 20195

Foaming occurs during treatment of high level waste (HLW) at Savannah River Site's Defense Waste Processing Facility (DWPF) in the Chemical Process Cell (CPC) due to high gas generation from process steam and chemical offgas products [1]. The presence of amphiphilic particles in the waste slurry stabilizes the foam [2], [3]. Efficient processing of HLW requires foam control, as foam-overs lead to lower productivity and potential radioactive contamination of condensate streams. DWPF currently employs Siovation Antifoam 747, a surfactant produced by Momentive Performance Materials, as an antifoaming agent during waste treatment. Despite its ability to control foam generation, processing issues have arisen from its use [4]. During DWPF chemical processing, a chemical antifoam agent must be effective at temperatures up to 103 deg. C between pH 3-13. Antifoam 747 is effective at pH 7 but degrades as pH deviates [5]. Antifoam 747 is 90% by weight Momentive{sup TM} L77 and 10% by weight Momentive{sup TM} Y-17580. These ingredients are trisiloxane products, which are especially vulnerable to attack in acidic and caustic environments. Since Antifoam 747 readily degrades, periodic addition is required. Several processing concerns related to Antifoam 747 have affected DWPF operation. Its overuse warranted concern of potential flammable melter offgas under upset conditions due to the generation of carbon dioxide and hydrogen. As a result, a Potential Inadequacy in the Safety Analysis (PISA) was declared [6]. Antifoam contribution has been included in the melter offgas flammability strategy and the quantity of antifoam is monitored to ensure limits are not exceeded. Testing at Savannah River National Laboratory (SRNL) determined that propanal, tri-methylsilanol, and hexamethyldisiloxane are generated as Antifoam 747 degrades, leading to a second PISA [7]. The formation of these byproducts poses additional flammability risks. Furthermore, the methyl and ethyl groups of these compounds may be responsible for the formation of the methyl and ethyl mercury discovered in DWPF [8], [9]. The formation of organomercury has specifically been called out by DOE as a need for increased research. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoam agents were evaluated as part of an effort to improve HLW treatment operations at DWPF and to reduce, or eliminate, the flammability hazards associated with Antifoam 747 currently in use. Foaming of high-level waste (HLW) slurries is an issue at the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) which is currently mitigated with a chemical antifoam agent. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoams were examined to improve HLW treatment at DWPF and to eliminate the flammability hazards associated with Siovation Antifoam 747 currently in use. Non-chemical foam control methods were deemed unviable for chemical processing at DWPF, as the spray/mist technique requires too much water and space limitations make installation and implementation of headspace agitators unfeasible. The use of ultrasonic energy thickened and further stabilized the foam. Two suitable alternative defoaming agents, Momentive{sup TM} Y- 17112 and Evonik Surfynol{sup R} MD-20, were identified. Both defoamers control foam over a pH range of 4- 13 at boiling, with no flammable degradation products, and only minimal quantities (100-200 mg/kg) are required under glycolic acid conditions. In order to validate the effectiveness of these defoaming agents, SRNL recommends irradiation testing and laboratory scale SRAT/SME experiments with actual radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pressurization Analysis for Heating of a Screw Top Utility Can Loaded With Plutonium Oxide Powder by a 1273 K Fire

The documented safety analysis for the Savannah River National Laboratory (SRNL) evaluates the consequences of a postulated 1273 K fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage containers. The oxide storage configuration selected for analysis is can/bag/can, comprised of oxide powder inside an 8.38 × 10 -6 m 3 stainless steel B vial inside 0.006 kg of polyethylene bagging inside a one-quart screw top utility can of the type commonly used to package solvents or rubber cements. To enable evaluation of the dose consequences, temperature and pressure transients have been calculated for exposure of a typical set of storage containers to the fire. The pressurization analysis credits venting to and from the B vial but does not credit venting or leakage from the can. Due to the low rate of venting from the B vial into the can gas space, the can pressure is nearly independent of the B vial pressure. Calculated maximum pressures are compared to the utility can burst pressure. In lieu of a structural analysis of the utility cans, burst pressures and leakage rates were measured using compressed nitrogen gas. The measured gauge burst pressure was 0.250 ± 0.043 MPa. The measured burst pressures are lower than the calculated maximum pressure due to fire exposure, indicating that the utility cans could burst during exposure to a 1273 K fire.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

AI-Enabled Robots for Automated Nondestructive Evaluation and Repair of Power Plant Boilers. Final Report

Boiler failure could cause loss of life and safety issues, cost hundreds of thousands of dollars in equipment repairs, property damage and production losses, and drive up the cost of electric power. Boiler maintenance is challenging and risky for inspectors working on scaffolding in confined hazardous spaces inside of a boiler and sometimes the space is hard to access. The operation is also time-consuming due to the large area of vertical structures for inspection and the tremendous effort needed for scaffolding. Recently, the use of robotics (e.g., drones and crawlers) in power plants for maintenance is growing rapidly. However, the existing robotics solutions show two notable technological gaps: no live repair capability, and no Artificial Intelligence (AI) for smart autonomy. The objective of this project is to develop an integrated autonomous robotic platform that is equipped with compact non-destructive evaluation (NDE) sensors to perform live inspection, operates onboard repair devices to perform live repair, and uses AI for intelligent data fusion and predictive analysis for automated and smart spatiotemporal inspection, analysis and repair of the furnace walls in coal-fired boilers. The approach to achieve the objective includes developing NDE sensors with signal processing techniques, designing and evaluating repair devices for robots based on fusion and solid-state technologies, and an autonomous robotic platform that can attach to and navigate on boiler furnace walls using magnetic drive tracks. The robot is also powered by AI to automate data gathering (e.g., 3D mapping and damage localization) and predictive analysis. This project has advanced the state-of-the-art by providing technological breakthroughs including compact NDE and repair tools for robots, AI capabilities for smart autonomy, and a robotic platform for automated boiler maintenance. This project has great potential to result in significant benefits including limiting or eliminating the need to send operators to assess difficult-to-access or hazardous areas, enabling automated live inspection and repair, avoiding time consuming scaffolding (especially for partial maintenance during unplanned outage), collecting comprehensive and well-organized data smartly, and avoiding or limiting the need for onsite or remote piloting technicians. The impacts can be tremendous in terms of the time and cost savings, reducing the risk for human operators, and increasing boiler reliability, usability, and efficiency. In addition, by developing the new technologies on the autonomous inspection and repair robot, by involving multiple undergraduate and graduate students working together with the faculty members on this project, and by generating knowledge and building up collaborations with industrial partners, this effort will significantly update the education capabilities, support long-term fundamental research, and maintain the leadership of Colorado School of Mines and Michigan State University in energy fields.

20 FOSSIL-FUELED POWER PLANTS↗

Quantitative Risk Assessment for Fuel Cell Electric Bus Hydrogen Storage and Refueling Facility

It is necessary to understand the safety implications and risk mitigation options for fuel cell electric bus fleet deployment, especially for related facilities responsible for operations such as production, storage, compression, and dispensing of hydrogen for use by the buses. In this report, we present a quantitative risk assessment for a potential fuel cell electric bus fleet that was motivated by efforts to improve resilience at the Portland International Airport but can be applicable to a range of hydrogen case studies and use cases. We estimated risk for a facility that produces, stores, compresses, and dispenses hydrogen for the fleet of buses, with a focus on individual risk to people in terms of annual frequency of fatality. We considered the frequency of hydrogen leaks that could result in harmful physical outcomes like jet fires or explosions, and the consequences of those outcomes for people. We created customized fault trees to calculate the frequencies of different sizes of leaks and event sequence diagrams to calculate ignition probabilities for the various leak sizes. We also leveraged the HyRAM+ toolkit to use these inputs to calculate overall risk for the facility, which we separated into one section responsible for producing, storing, and compressing hydrogen, and one section responsible for dispensing the hydrogen to the buses. We found that the dispensing area seemed to have a higher risk than the production/storage/compression area of the facility, largely because of the inclusion of a component with a high leak frequency (the heat exchanger used to cool the hydrogen before entering the vehicle, to prevent overheating and expansion of hydrogen in the onboard tank). For the example production and refueling facility we evaluated and the data we used for the analysis, the leak frequency had a larger impact on the risk differences between the two sections on the facility, compared to the physical outcome consequence, which was slightly different due to the varying fuel conditions, but not substantially different. Actions can be taken to prevent these hazards (e.g., lowering leak frequencies in system components) or to mitigate the consequences if they do occur (e.g., installing barriers to protect people if ignition events occur). The choice of which actions to take depends not only on safety considerations but also on space, time, staffing, feasibility, and financial constraints. Therefore, the quantitative risk assessment approach can help understand relative risk contributions from different components, leak sizes, consequences, and human actions, to prioritize risk reduction strategies and balance these parameters. The outcomes of this report may be useful for a variety of stakeholders working in the hydrogen, transportation, vehicle, and aviation sector, including those responsible for aspects like facility design, operations, and regulations. There is not a single value of risk that determines whether a hypothetical system is “safe” or not. The insights about risk mitigations may be leveraged, and the quantitative risk assessment approach can be applied to other case studies to understand risk priorities and contributions specific to different FCEB and hydrogen facility uses.

08 HYDROGEN↗

Radiation Hardened Foam Cold Test Plan - Phase II: Foam Characterization Testing and Environmental Chamber Testing of FoamBag Fixative Foam

This document outlines the Phase II test objectives and implementation plan for a down-select foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of a polyurethane resin foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed at FIU and SRNL test and lab facilities. Results from the cold tests will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the area and transported to a designated disposal facility. Phase I testing was previously conducted using Hilti CP620 fixative foam. Results from Phase I testing indicate Hilti CP-620 fixative foam is incompatible with SRS site hot taps as an effective foam delivery method into Hastelloy C-22 piping. Phase II testing will be conducted using FoamBag TM fixative foam as an alternative fixative foam option. Phase II testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of FoamBag TM in Hastelloy C-22 piping, (2) evaluation of the adhesion of FoamBag TM in piping under various moisture conditions, (3) determination of the heat profile of FoamBag TM during curing, (4) determination of the internal pipe pressure after FoamBag TM deployment and curing, (5) conduct a leak test to determine if FoamBag TM is effective at creating a full seal within piping, (6) headspace testing of FoamBag TM to determine if there are any associated off-gas hazards during FoamBag TM curing, (7) conduct environmental chamber testing of FoamBag TM to understand how environmental parameters impacts FoamBag TM curing, and (8) conduct fire testing to evaluate FoamBag TM fire retardant characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗