Computer program details for design of sensible-heat space radiators
Fortran program for sensible-heat space radiator design
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fortran program for sensible-heat space radiator design
Determining heat transfer to space vehicles entering planetary atmospheres for proper design and thermal protection
Information necessary to evaluate the design of a solar space heating and hot water system is reported. System performance specifications, the design data brochure, the system description, and other information pertaining to the design are included.
Design analysis and general characteristics of flat plate central fin-tube sensible-heat space radiators under thermodynamic and fluid mechanic conditions
Thermal analyses were conducted to evaluate the thermal response of various individual materials and multi-layer configurations for an in-space heat shield exposed to a rocket plume during stage separation. Frequently used, readily available thermal protection materials consisting of cork, carbon cloth phenolic (CCP), and silica cloth phenolic (SCP) were selected for an initial screening analysis. SCP was chosen as the primary material for further evaluation using an updated thermal environment calculated using computational fluid dynamics (CFD) results. A multi-layer configuration consisting of SCP providing erosion resistance and a Nomex honeycomb providing thermal protection was then evaluated as a solution for more mass-efficient performance. Pyrolysis depth, bondline temperature, back-side temperature, and a thermal factor of safety were used to define the necessary material thickness profile. Adhesives were included in the analyses with considerations for maximum temperature and application method. One dimensional thermal analyses at several stations along the heat shield surface were performed for the initial screening and follow-on analyses. The methodology used standard processes and computer programs applicable to solid rocket motor internal insulation and nozzle thermal analysis such as Chemical Equilibrium and Applications (CEA), Aerotherm Chemical Equilibrium (ACE), Momentum/Energy Integral Technique (MEIT), and Insulation Thermal Response and Ablation Code (ITRAC). The baseline SCP/Nomex honeycomb multi-layer configuration thermal performance predictions satisfied the objectives with an acceptable mass estimate for the design maturity. The EA9673 film adhesive and SCP resin were the best performing bonding agents considered for the SCP/Nomex honeycomb and Nomex honeycomb/structural substrate interfaces. The baseline mass estimate was lowest when the resin was the bonding agent due to the higher maximum service temperature. These thermal analyses evaluated typical internal and external nozzle materials using a calculated thermal environment and heat loads that were lower than a typical rocket motor internal environment but greater than standard external aeroheating.
The effect of the meteoroid/space debris environment on the design and evolution of spacecraft waste heat rejection radiator systems is discussed. Active radiator systems; i.e., systems in which waste heat is collected from the various heat sources within a spacecraft and delivered to the radiator system by a heat transport loop are emphasized. The heat is distributed over the radiator area and thus rejected to space. Present and future systems are discussed.
Complete heat-flux and temperature maps computed. Computer program SSQ developed to address and quantify complex, solar-shadowing conditions inherent in sparse, lattice-type space structures. Analysis procedure one of assessing partial shadowing of structural elements by multiple, similar slender members. Program yields schedules of incident-solar, Earth-thermal, and Earth-albedo radiation throughout complete orbit for elemental locations on selected structural members. Thermal response computed in optional routine. Complete heat-flux and temperature mapping obtained by repeated computations for selected elements of interest.
A collection of three quarterly reports are given covering the development of two prototype solar heating systems consisting of the following subsystems: collector, storage, control, transport, and site data acquisition. The two systems are being installed at York, Pennsylvania, and Manchester, New Hampshire.
A 12 months performance of Visitors Center installation suffered from low insolation, high energy dissipation, and equipment breakdown. System has 980 square feet of liquid flat-plate collectors, water energy storage, 4-mode control, heat exchangers, pumps, and plumbing. Design expected system to supply over 50 percent of annual heating demand, but only 109 million Btu were conserved.
The solar energy system located at the Visitors' Center on the Stephens College Campus, Columbia, Missouri is discussed. The system is installed in a four-story, 15,000 square foot building. The solar energy system is an integral design of the building and utilizes 176 hydronic flat plate collectors which use a 50 percent water ethylene blycol solution and water-to-water heat exchanger. Solar heated water is stored in a 5,000 gallon water storage tank located in the basement equipment room. A natural gas fired hot water boiler supplies hot water when the solar energy heat supply fails to meet the demand. The designed solar contribution is 71 percent of the heating load.
New report describes warehouse/office building in Kansas City, Kansas which uses solar heating for warehouse portion and conventional heating and cooling for office portion. Building is divided into 20 equal units, each with its own solar-heating system. Modular design enables multiple units to be combined to form offices or warehouses of various sizes as required by tenants.
The solar energy system was constructed with the 48,800 square feet warehouse to heat the warehouse area of about 39,000 square feet while an auxiliary energy system heats the office area of about 9,800 square feet. The building is divided into 20 equal units, and each has its own solar system. The modular design permits the flexibility of combining multiple units to form offices or warehouses of various size floor areas as required by a tenant. Each unit has 20 collectors which are mounted in a single row. The collectors are double glazed flat plate collectors with a gross area of 7,800 sq ft. Air is heated either through the collectors or by the electric resistance duct coils. Extracts from the site files, specifications, drawings, installation, operation and maintenance instructions are presented.
Critical technology experiments have been performed on thermal energy storage modules in support of the Brayton Advanced Heat Receiver program. The modules are wedge-shaped canisters designed to minimize the mechanical stresses that occur during the phase change of the lithium fluoride phase change material. Nickel foam inserts were used in some of the canisters to provide thermal conductivity enhancement and to distribute the void volume. Two canisters, one with a nickel foam insert, and one without, were thermally cycled in various orientations in a fluidized bed furnace. The only measurable impact of the nickel foam was seen when the back and short sides of the canister were insulated to simulate operation in the advanced receiver design. In tests with insulation, the furnace to back side delta T was larger in the canister with the nickel foam insert, probably due to the radiant absorptivity of the nickel. However, the differences in the temperature profiles of the two canisters were small, and in many cases the profiles matched fairly well. Computed Tomography (CT) was successfully used to nondestructively demarcate void locations in the canisters. Finally, canister dimensional stability, which was measured throughout the thermal cycling test program with an inspection fixture was satisfactory with a maximum change of 0.635 mm (0.025 in.).
Critical technology experiments have been performed on thermal energy storage modules in support of the NASA Advanced Solar Dynamic Brayton Heat Receiver Program. The modules, wedge-shaped canisters containing lithium fluoride (LiF), were designed to minimize the mechanical stresses that occur during the phase change of the LiF. Nickel foam inserts were placed in two of the test canisters to provide thermal conductivity enhancement and to distribute the void volume throughout the canister. A procedure was developed for reducing the nickel oxides on the nickel foam to enhance the wicking ability of the foam. The canisters were filled with LiF and closure-welded at the NASA Lewis Research Center. Two canisters, one with a nickel foam insert, the other without an insert, were thermally cycled in various orientations in a fluidized bed furnace. Computer-aided tomography was successfully used to nondestructively determine void locations in the canisters. Finally, canister dimensional stability was measured after thermal cycling with an inspection fixture.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Astronauts exposed to prolonged weightlessness will experience deconditioning, dehydration, and hypovolemia which all adversely affect thermoregulation. These thermoregulatory problems can be minimized by several countermeasures that manipulate body water and vascular volumes. USARIEM scientists have extensively studied dehydration effects and several possible countermeasures including hyperhydration, plasma and erythrocyte volume expansion. This paper reviews USARIEM research into these areas.
The work being carried out at the University of Florida Solar Energy and Energy Conversion Laboratory in converting solar energy, our only income, into other needed and useful forms of energy is described. A treatment such as this demonstrates, in proper perspective, how solar energy can benefit mankind with its many problems of shortages and pollution. Descriptions were given of the conversion processes, equipment, and performance. The testing of materials, solar water heating, space heating, cooking and baking, solar distillation, refrigeration and air-conditioning, work with the solar furnace, conversion to mechanical power, hot air engines, solar-heated sewage digestion, conversion to electricity, and other devices will be discussed.