Search NASA⌕ Search

SEARCH · Search NASA

Results for “space heating electrification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Datasets for Widespread Residential Space Heating Electrification in Texas

In this experiment, we explore long term patterns in electricity demand driven by the dual effects of full electrification of space heating in Texas (by adoption of electric heat pumps), and climate change. We use a predictive model of electricity demand, climate projections, and an open source nodal power system (DC Optimal Power Flow) model of the Electric Reliability Council of Texas (ERCOT) system. Heat pumps are a more energy efficient way of providing space heating and cooling in homes. We attempt to exhaustively investigate the impacts of full residential space heating electrification by adoption of heat pumps for the segment of Texas households that currently rely on fossil fuels (about 40%), while simultaneously incorporating climate change meteorological variables. We explore a range of scenarios of heat pump efficiency and climate uncertainty over a long period of future years (2020-2099). In total, the simulation experiment generates 1,280 simulation years of hourly data. We report and analyze results in form of impacts on residential load, total load, peak load, seasonality of peaking, and reliability measured by occurrence and frequency of loss of load events. While the experiment is for ERCOT, the insights and approach can be applied to other regions. The results from the analysis can inform system planners on a range of potential capacity requirements/ reliability implications and/or risks of full space heating electrification via the adoption of electric heat pumps, given the uncertainty in the scenarios/ climate futures. The dataset includes model output for residential, non residential and total load, and the results from the GO ERCOT model runs for 4 RCP Scenarios (RCP 4.5 Cooler, RCP 4.5 Hotter, RCP 8.5 Cooler, RCP 8.5 Hotter), 4 Heating electrification Scenarios (Base , Standard Efficiency HP, High Efficiency HP, Ultra-High Efficiency HP) over 80 years (2020-2099). The metrological variables at BA scale were weighted weighted using population projections consistent with the SSP3 scenario.

Climate Change↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon and energy cost impacts of electrification of space heating with heat pumps in the US

In order to meet climate goals, it will be necessary to significantly reduce the greenhouse gases emitted by homes. A key factor in the US is to reduce the on-site combustion of fossil fuels for heating end-uses and to replace this with use of electric heat pump technologies connected to a low-carbon grid. The replacement of natural gas furnaces with electric heat pumps is a key home decarbonization strategy. However, the potential for space heating electrification to reduce greenhouse gas emissions depends on the carbon dioxide equivalent (CO 2 e) content of the electricity used by the heat pump. This varies considerably depending on the source of electricity, with large state to state variability. Furthermore, household energy costs are likely to be impacted by the electrification of space heating, because retail energy prices for both natural gas and electricity in each state vary by factors of seven and four, respectively. Contractors, energy programs, government and building code officials, as well as consumers need clear indications of the likely CO 2 e and energy cost impacts of proposed electrification projects, because these will affect decarbonization choices and rationales around scaled heating electrification. Government and utility programs also need to be aware of the likely outcomes of any supported/incentivized measures. Here, in this paper, we investigate these effects by looking at new metrics to analyze the change in CO 2 e emitted and the cost to meet home heating loads when switching from a natural gas furnace to a heat pump for the contiguous 48 states of the mainland US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

Among 32 million multi-family buildings in the United States, approximately 42% have poor or no insulation. Envelope retrofits of these buildings will provide thermal resiliency and enable a pathway to electrification of space heating systems as a result of improved thermal performance. Hydronic Shell (HS) is a technology which combines an insulated retrofit panel with a heating, ventilation and air-conditioning (HVAC) thus enabling both envelope retrofit and space heating electrification. In this study, we used whole building energy simulation to evaluate energy impact of multi-family building retrofit with hydronic shell system. The simulation was performed for four locations of New York, Syracuse, Chicago and Boston. The results from the simulation showed more than 66% cooling energy reduction and more than 88% heating energy reduction from Hydronic Shell retrofit compared to Baseline building in all four locations. This reduction in energy consumption resulted in up to 219 MT reduction in annual CO2 emission. The cost reduction per floor area achieved from HVAC energy consumption reduction using Hydronic Shell retrofit was 0.66 to 0.99 $\$$/ft 2 . The results also showed higher percentage of heating energy reduction comes from the envelope only retrofit and higher percentage of cooling energy reduction comes from the retrofit HVAC system for the four locations under study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Size Up or Size Down? National Analysis of Heat Pump Sizing and Impacts

Electrification of on-site fossil fuel combustion in buildings is recognized as a key component of achieving global greenhouse gas emissions targets. Air-source heat pumps are an efficient approach for space heating electrification. However, a major barrier to heat pump adoption is the high installation cost relative to furnaces and air conditioners. Because the installation cost of heat pumps - especially cold climate models - is dependent on their size, it is important to understand the distribution of heat pump sizes using different sizing methods and factors that impact heat pump sizing. In this study, we use sub-hourly physics simulations of 550,000 statistically representative dwelling units to analyze the distribution of heat pump size in the U.S. for three different efficiency levels of heat pumps, with and without building insulation and air sealing upgrades. We will present results from the national analysis of different factors affecting heat pump sizing along with the impact of sizing decisions on upgrade costs and operating costs.

electrification↗

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock

Twenty percent (25%) of the energy consumed by the U.S. commercial building sector is from on-site combustion of fossil fuels for space heating. Part of decarbonizing U.S. energy systems to meet climate initiatives will require electrification of space heating equipment, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for electrification solutions. However, there is limited understanding of the impact on emissions when considering regional electricity generation methods, as well as the impact of ambient temperature on capacity and efficiency, defrost operation, realistic sizing methodologies, and supplementary heating on overall heat pump performance. This study explores the effects of transitioning all installed, existing RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock (TM), the U.S. Department of Energy's calibrated model of the U.S. commercial building stock. Results show 10% and 9% reductions in stock aggregate energy consumption and greenhouse gas emissions, respectively. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building↗

Decarbonizing HVAC and Water Heating in Commercial Buildings

This report is intended to provide building owners and facilities engineers with heating electrification options and design considerations, as well as additional resources on key topics. The document focuses on the electrification of space heating and water heating loads using electric heat pump systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

According to the 2020 residential energy consumption survey, there are 32 million multi-family buildings in the United States, and approximately 42% of these have poor or no insulation (US EIA 2020). Electrification of buildings with heat pump is one of the key strategies to achieve the goal of 90% reduction of greenhouse gas emissions in buildings by 2050 (U.S. Department of Energy 2024a). Building electrification will also enable greater penetration of variable renewable energy sources. However, replacing the natural gas dominated heating system by electrical appliance will increase the electrical load in heating dominated climate. It is crucial to well-insulate the building envelope to mitigate the stress in the grid from electrification. The hydronic shell (HS) system discussed next can achieve dual objective of envelope retrofit with space heating system electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Valuation of Novel Waste Heat Sources and a Path Towards Adoption: Preprint

It is recognized that beneficial electrification of most space heating will be necessary to avert the worst consequences of climate change. Fifth generation district heating and cooling (5GDHC) networks operate at near-ambient temperatures and thus facilitate heating electrification, as well as the use of waste heat sources at a wide range of temperatures. In this paper, we analyze the potential of waste heat to supply the required heat to these networks and describe the business models that could expand the use of these waste heat sources. Showcase single family and commercial districts in the US are discussed to demonstrate emerging technologies, district infrastructure approaches, and third-party thermal utility funding models for these leading 5GDHC networks. As part of this work, heat flow and temperature profiles from five different types of waste heat sources are analyzed. An example district is used to examine the integration potential and to quantify the potential reduction in energy consumption. The results indicate that 5GDHC networks are highly suitable systems for utilizing low to moderate temperature waste heat sources. In the studied district, waste heat can cover a share of up to 66% of the heat supplied to the ambient loop and reduce the overall electricity consumption for heating by up to 51%, depending on the characteristics of the specific power, temperature, and type of waste heat source. Through their moderate operating temperatures and use of waste heat sources combined with third party financed infrastructure, 5GDHC districts have significant potential to reduce carbon emissions associated with space conditioning.

district energy↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Simulation of a PCM Integrated Heat Pump Using Time-of-Use Utility Structure based Control Strategy for Demand Response

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries and constructing new peaking power plants. The aggressive carbon reduction goals of the United States are accelerating the electrification of building equipment. If space heating and cooling in the US were electrified using conventional heat pump technologies, the winter electric grid peak would approximately double. Integrating TES with heat pump (HP) enables electrification of space cooling and heating devices without overtaxing the grid.This paper evaluates the benefits of a novel phase change material (PCM) integrated heat pump configuration via simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation.To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

Li, Zhenning↗

Overview of Building Electrification Technologies and Market Opportunities

This report provides an overview of building electrification drivers and select building electrification technologies and their markets and performance. Covered topics: Building Electrification Drivers and Context; Heat Pumps for Space Conditioning; Heat Pump Market Opportunities; Life Cycle GHG Emissions Impacts of Heat Pump Space Conditioning Technologies; Heat Pump Water Heaters; Electrification of Gas Loads: Commercial and Residential; Residential Panel Capacity; Electric Vehicle Impacts and Connections to Buildings; and Building Envelope Improvements and Thermal Energy Storage (TES) Opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗