Search NASA⌕ Search

SEARCH · Search NASA

Results for “space needle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Space Needle, Seattle, WA

Environmental data from the top of the Space Needle

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Industrial Steerable Needle for Inspecting Extremely Confined Spaces in Nuclear Facilities - 18316

We present a novel, compliant mechanism inspired by steerable needles for endoscopic surgery that provides the capability to navigate extremely confined spaces for the purpose of infrastructure inspection. Extremely confined spaces are commonly encountered during infrastructure inspection of nuclear facilities. These spaces can include pipes and ventilation ducts. Often these infrastructure features go uninspected simply because there is no viable way to access their interior. In addition, it is not uncommon for extremely confined spaces to be laid-out in a spider-web fashion that must be selectively navigated in order to execute an inspection. Recently, millimeter-scale imagers have become commercially available. These imagers are small enough to fit inside an extremely confined space, but there is currently no means to bring the imager to the portion of the structure that must be inspected. In this work this problem is addressed by taking inspiration from the field of steerable needles used in endoscopic surgery. Steerable needles are long flexible shafts that are capable of being directed through the human body using control forces applied external to the body. Unfortunately, steerable needles cannot be directly applied to the problem of navigating maze-like arrangements of extremely confined spaces. Traditional steerable needles must operate within a solid medium that can be penetrated in order to be steered so they are not directly applicable to navigating extremely confined spaces. However surgical steerable needles do suggest an approach to the problem. Steerable needles are typically made from super-elastic nitinol. This material has the property that it can experience high strain without yielding. Furthermore, superelastic nitinol is stiff enough that it is possible to push the tube down a long, maze-like arrangement of a confined space without buckling. The stiffness properties of nitinol combined with its high yield strain makes it an attractive material for navigating a tube through a maze-like arrangement of extremely confined spaces. The ability to selectively navigate extremely confined spaces opens up new possibilities to use emerging miniature imaging technology for infrastructure inspection. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector

Purpose: Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. Methods: The system consists of a flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 {sup 125}I seeds, and IsoAid Advantage {sup 103}Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Results: Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for {sup 125}I 6711 seeds, 4.7% for {sup 125}I 9011 seeds, and 11.0% for Advantage {sup 103}Pd seeds. Conclusions: This study showed that a flat panel detector dosimetry system is a viable option for source strength verification in preloaded needles, as it is capable of measuring all of the sources intended for implantation. Such a system has the potential to directly and efficiently estimate individual source strengths, the overall mean source strength, and the positions within the seed-spacer train.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-10: Assessment of Fiber Bragg Grating (FBG)-Based Sensing for Real-Time Needle Tracking During MR-Guided Brachytherapy

Purpose: This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. Methods: The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needle’s deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its position and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. Results: Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. Conclusion: The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-758: To Determine the Source Dwell Positions of HDR Brachytherapy Using 2D 729 Ion Chamber Array

Purpose: Determination of source dwell positions of HDR brachytherapy using 2D 729 ion chamber array Methods: Nucletron microselectron HDR and PTW 2D array were used for the study. Different dwell positions were assigned in the HDR machine. Rigid interstitial needles and vaginal applicator were positioned on the 2D array. The 2D array was exposed for this programmed dwell positions. The positional accuracy of the source was analyzed after the irradiation of the 2D array. This was repeated for different dwell positions. Different test plans were transferred from the Oncentra planning system and irradiated with the same applicator position on the 2D array. The results were analyzed using the in house developed excel program. Results: Assigned dwell positions versus corresponding detector response were analyzed. The results show very good agreement with the film measurements. No significant variation found between the planned and measured dwell positions. Average dose response with 2D array between the planned and nearby dwell positions was found to be 0.0804 Gy for vaginal cylinder applicator and 0.1234 Gy for interstitial rigid needles. Standard deviation between the doses for all the measured dwell positions for interstitial rigid needle for 1 cm spaced positions were found to be 0.33 and 0.37 for 2cm spaced dwell positions. For intracavitory vaginal applicator this was found to be 0.21 for 1 cm spaced dwell positions and 0.06 for 2cm spaced dwell positions. Intracavitory test plans reproduced on the 2D array with the same applicator positions shows the ideal dose distribution with the TPS planned. Conclusion: 2D array is a good tool for determining the dwell position of HDR brachytherapy. With the in-house developed program in excel it is easy and accurate. The traditional way with film analysis can be replaced by this method, as the films will be more costly.

60 APPLIED LIFE SCIENCES↗

Epidural anesthesia needle guidance by forward-view endoscopic optical coherence tomography and deep learning

Epidural anesthesia requires injection of anesthetic into the epidural space in the spine. Accurate placement of the epidural needle is a major challenge. To address this, we developed a forward-view endoscopic optical coherence tomography (OCT) system for real-time imaging of the tissue in front of the needle tip during the puncture. We tested this OCT system in porcine backbones and developed a set of deep learning models to automatically process the imaging data for needle localization. A series of binary classification models were developed to recognize the five layers of the backbone, including fat, interspinous ligament, ligamentum flavum, epidural space, and spinal cord. The classification models provided an average classification accuracy of 96.65%. During puncture, it is important to maintain a safe distance between the needle tip and the dura mater. Regression models were developed to estimate that distance based on the OCT imaging data. Based on the Inception architecture, our models achieved a mean absolute percentage error of 3.05% ± 0.55%. Overall, our results validated the technical feasibility of using this novel imaging strategy to automatically recognize different tissue structures and measure the distances ahead of the needle tip during the epidural needle placement.

60 APPLIED LIFE SCIENCES↗

Computer-aided Veress needle guidance using endoscopic optical coherence tomography and convolutional neural networks

During laparoscopic surgery, the Veress needle is commonly used in pneumoperitoneum establishment. Precise placement of the Veress needle is still a challenge for the surgeon. In this study, a computer-aided endoscopic optical coherence tomography (OCT) system was developed to effectively and safely guide Veress needle insertion. This endoscopic system was tested by imaging subcutaneous fat, muscle, abdominal space, and the small intestine from swine samples to simulate the surgical process, including the situation with small intestine injury. Each tissue layer was visualized in OCT images with unique features and subsequently used to develop a system for automatic localization of the Veress needle tip by identifying tissue layers (or spaces) and estimating the needle-to-tissue distance. We used convolutional neural networks (CNNs) in automatic tissue classification and distance estimation. In conclusion, the average testing accuracy in tissue classification was 98.53 ± 0.39%, and the average testing relative error in distance estimation reached 4.42 ± 0.56% (36.09 ± 4.92 μm).

59 BASIC BIOLOGICAL SCIENCES↗

CT Fluoroscopy-Guided Transsacral Intervertebral Drainage for Pyogenic Spondylodiscitis at the Lumbosacral Junction

PurposeTo retrospectively describe the feasibility and efficacy of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction with a combination of two interventional radiological techniques—CT-guided bone biopsy and abscess drainage.Materials and methodsThree patients with pyogenic spondylodiscitis at the lumbosacral junction were enrolled in this study between July 2013 and December 2015. The procedure of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction was as follows: the sacrum at S1 pedicle was penetrated with an 11-gauge (G) bone biopsy needle to create a path for an 8-French (F) pigtail drainage catheter. The bone biopsy needle was withdrawn, and an 18-G needle was inserted into the intervertebral space of the lumbosacral junction. Then, a 0.038-inch guidewire was inserted into the intervertebral space. Finally, the 8-F pigtail drainage catheter was inserted over the guidewire until its tip reached the intervertebral space. All patients received six-week antibiotics treatment.ResultsSuccessful placement of the drainage catheter was achieved for each patient without procedural complications. The duration of drainage was 17–33 days. For two patients, specific organisms were isolated; thus, definitive medical therapy was possible. All patients responded well to the treatment.ConclusionsCT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction is feasible and can be effective with a combination of two interventional techniques—CT fluoroscopy-guided bone biopsy and abscess drainage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data-Driven Model Reduction of Multiphase Flow in a Single-Hole Automotive Injector

Fuel injector design has a substantial influence on the performance and emissions of direct injection engines. To date, large eddy simulations coupled with a single-fluidmixture modeling approach have shown great success in evaluating the complex interplay among injector design, fuel properties, and operating conditions on the injector performance. However, this simulation approach is too computationally expensive to be used by industry routinely for injector design due to the fine temporal and spatial resolution required to resolve wall-bounded flow within the injector. The work presented in this paper highlights a potential pathway to addressing this issue. To study the influence of injector design, fuel properties, and operating conditions on injector performance, large eddy simulations were performed to model the turbulent multiphase flow development through a side-oriented singlehole diesel injector. Using Latin hypercube sampling, the design space spanning a range of fuel properties, operating conditions, and needle lifts were explored. Two techniques for dimensionality reduction, namely proper orthogonal decomposition and autoencoders, were compared to evaluate their accuracy in representing the flow in a reduced dimensional space. Finally, based on the findings from this work, recommendations are provided in using machine learning approaches within the context of emulation to construct reduced-ordermodels for internal flow development relevant to automotive applications.

42 ENGINEERING↗

Hydrogen Generation and Serpentinization of Olivine Under Flow Conditions

Serpentinization of olivine is often studied in the laboratory under batch conditions. Olivine conversion in situ with enhanced natural hydrogen production will likely be implemented via injection of aqueous solutions. Hence, transport is relevant to the extent of olivine reaction and, potentially, the morphology of precipitates formed. To test conditions for optimal H 2 generation and outcomes, serpentinization was induced by injecting pH = 12.5 brine at 0.015 cm 3 /min (0.5 pore volumes per day) into an olivine sand pack (250 to <355 μm grain size) at 245°C generating, at minimum 76 and 89 mol% H 2 at 35 and 57 d, respectively. Grain-coating serpentine with radiating needles cemented the reacted sand grains. Importantly, pore space was maintained between the dissolving grains and the serpentine precipitates. Hence, reactivity continued as a result of fluid access to mineral surfaces, the large grain size, and the continuous injection of undersaturated alkaline fluids.

08 HYDROGEN↗

SU-F-BRA-04: Prostate HDR Brachytherapy with Multichannel Robotic System

Purpose: High-dose-rate (HDR) brachytherapy is gradually becoming popular in treating patients with prostate cancers. However, placement of the HDR needles at desired locations into the patient is challenging. Application of robotic system may improve the accuracy of the clinical procedure. This experimental study is to evaluate the feasibility of using a multichannel robotic system for prostate HDR brachytherapy. Methods: In this experimental study, the robotic system employed was a 6-DOF Multichannel Image-guided Robotic Assistant for Brachytherapy (MIRAB), which was designed and fabricated for prostate seed implantation. The MIRAB has the provision of rotating 16 needles while inserting them. Ten prostate HDR brachytherapy needles were simultaneously inserted using MIRAB into a commercially available prostate phantom. After inserting the needles into the prostate phantom at desired locations, 2mm thick CT slices were obtained for dosimetric planning. HDR plan was generated using Oncetra planning system with a total prescription dose of 34Gy in 4 fractions. Plan quality was evaluated considering dose coverage to prostate and planning target volume (PTV), with 3mm margin around prostate, as well as the dose limit to the organs at risk (OARs) following the American Brachytherapy Society (ABS) guidelines. Results: From the CT scan, it is observed that the needles were inserted straight into the desired locations and they were adequately spaced and distributed for a clinically acceptable HDR plan. Coverage to PTV and prostate were about 91% (V100= 91%) and 96% (V100=96%), respectively. Dose to 1cc of urethra, rectum, and bladder were within the ABS specified limits. Conclusion: The MIRAB was able to insert multiple needles simultaneously into the prostate precisely. By controlling the MIRAB to insert all the ten utilized needles into the prostate phantom, we could achieve the robotic HDR brachytherapy successfully. Further study for assessing the system’s performance and reliability is in progress.

60 APPLIED LIFE SCIENCES↗

A compliant mechanism for inspecting extremely confined spaces

We present here a novel, compliant mechanism that provides the capability to navigate extremely confined spaces for the purpose of infrastructure inspection. Extremely confined spaces are commonly encountered during infrastructure inspection. Examples of such spaces can include pipes, conduits, and ventilation ducts. Often these infrastructure features go uninspected simply because there is no viable way to access their interior. In addition, it is not uncommon for extremely confined spaces to possess a maze-like architecture that must be selectively navigated in order to properly perform an inspection. Efforts by the imaging sensor community have resulted in the development of imaging sensors on the millimeter length scale. Due to their compact size, they are able to inspect many extremely confined spaces of interest, however, the means to deliver these sensors to the proper location to obtain the desired images are lacking. To address this problem, we draw inspiration from the field of endoscopic surgery. Specifically we consider the work that has already been done to create long flexible needles that are capable of being steered through the human body. These devices are typically referred to as 'steerable needles.' Steerable needle technology is not directly applicable to the problem of navigating maze-like arrangements of extremely confined spaces, but it does provide guidance on how this problem should be approached. Specifically, the super-elastic nitinol tubing material that allows steerable needles to operate is also appropriate for the problem of navigating maze-like arrangements of extremely confined spaces. Furthermore, the portion of the mechanism that enters the extremely confined space is completely mechanical in nature. The mechanical nature of the device is an advantage when the extremely confined space features environmental hazards such as radiation that could degrade an electromechanically operated mechanism. Here, we present a compliant mechanism developed to navigate maze-like arrangements of extremely confined spaces. The mechanism is shown to be able to selectively navigate past three 90° bends. The ability to selectively navigate extremely confined spaces opens up new possibilities to use emerging miniature imaging technology for infrastructure inspection.

47 OTHER INSTRUMENTATION↗

Microstructure and strengthening of Al-6Ce-3Ni-0.7Fe (wt%) alloy manufactured by laser powder-bed fusion

In this study, an Al-6Ce-3Ni-0.7Fe (wt%) alloy was fabricated via laser powder-bed fusion and its microstructure, thermal stability, tensile properties, and creep properties are investigated for two rapid-solidification rates with different eutectic spacings. For both faster- and slower-cooled states, the as-fabricated alloy mostly shows elongated grains with very fine eutectic networks (~40 nm lamellar width) comprising a high-volume fraction (~18 %) of intermetallic phases. Faster-cooled samples, however, display a less continuous eutectic network with finer spacing (~100 nm), leading to higher Orowan strengthening and therefore superior microhardness and yield stress up to ~350 °C. Upon aging (300 - 450 °C), micron-size Al 9 (Ni,Fe) 2 needle-like precipitates form within grains, and the Al 11 Ce 3 eutectic network spheroidizes, while retaining a submicron width and spacing, resulting in 33–37 % drop in microhardness after 144 h aging at 400 °C. Limited tensile ductility (~6 %) and creep ductility (~1-2 %) are measured for both faster- and slower-cooled alloys due to an inhomogeneous microstructure, where cavitation preferentially initiates at melt-pool boundaries, precipitate-free zones, and/or denuded zones, eventually leading to local fracture. Denuded zones, induced by stress, form due to diffusional flow with stress-dependent orientations, and are identified as microstructurally weak regions leading to strain localization. The present alloy does not show a significant difference in 300 °C creep resistance between: (i) tensile and compressive loading, (ii) faster- and slower-cooled samples, and (iii) continuous and spheroidized eutectics. Creep resistance at 300 °C is comparable to that of a Ce-richer Al-10.5Ce-3.1Ni-1.2Mn (wt%) alloy, despite the formation of denuded zones and needle-like Al 9 (Ni,Fe) 2 precipitates.

36 MATERIALS SCIENCE↗

Renewable energy in focus: In{sub 5}Se{sub 5}Br, a solid material with promising thermoelectric properties for industrial applications

Highlights: • In{sub 5}Se{sub 5}Br contains indium simultaneously in three different oxidation states. • Bulk sample of In{sub 5}Se{sub 5}Br shows n-type conductivity. • The Seebeck voltage increases linearly with the temperature difference increase. • In bulk In{sub 5}Se{sub 5}Br the resistivity oscillates between 2.6 MΩ and 23 MΩ. • DTA and HT-powder XRD data show incongruent melting of the compound. - Abstract: We obtained via solid state synthesis needle-shaped crystals of In{sub 5}Se{sub 5}Br crystallizing in the space group Pmn2{sub 1} and containing indium simultaneously in three different oxidation states: In{sup +}, formal In{sup 2+} and In{sup 3+}. Bulk sample of In{sub 5}Se{sub 5}Br shows n-type conductivity and linear increase of Seebeck voltage with the temperature difference increase. Seebeck voltage of approx. 720 mV is recorded at a temperature difference of 80 K, corresponding to a Seebeck coefficient −8900 μV/K. A voltage increase up to 250 mV is recorded within 10 min upon application of a 27 K temperature difference between the contacts. On-off switching of the heating source unveils repeatable results. Linear I–U behavior with a resistivity of 2.32 × 10{sup 11} Ω is observable for individual needles of In{sub 5}Se{sub 5}Br. In bulk In{sub 5}Se{sub 5}Br the resistivity oscillates between 2.6 MΩ and 23 MΩ. DTA and HT-powder XRD data show incongruent melting to InBr, InSe and In{sub 2}Se{sub 3} at 805 K. The ternary compound expands 1.02% along [0 1 0] showing a coefficient of thermal expansion α{sub b} = 2.3(4) × 10{sup −5} K{sup −1}. Lower expansions of 0.6% and 0.16% along a and c axes corresponding to mean coefficients of thermal expansion of α{sub a}{sup ¯} = 1.3(1) × 10{sup −5} K{sup −1}, α{sub c}{sup ¯} = 4.4(5) × 10{sup −6} K{sup −1} are observed. Thin layer growing of In{sub 5}Se{sub 5}Br on glass substrate with targeted doping/substitutions can improve the sample conductivity, increase the Seebeck coefficient and lower the thermal conductivity making In{sub 5}Se{sub 5}Br a good alternative material for industrial thermoelectric applications.

36 MATERIALS SCIENCE↗

The h –Sb x WO 3+2 x Oxygen Excess Antimony Tungsten Bronze

Here, we describe the previously unreported oxygen excess hexagonal antimony tungsten bronze with composition Sb 0.5 W 3 O 10 , in the following denoted as h –Sb x WO 3+2 x with x = 0.167, to demonstrate its analogy to classical A x WO 3 tungsten bronzes. This compound forms in a relatively narrow temperature range between 580 °C < T < 620 °C. It was obtained as a dark–blue polycrystalline powder, and as thin, needle–shaped, blue single crystals. h –Sb x WO 3+2 x crystallizes in the hexagonal space group P 6/ mmm with the cell parameters a=7.4369(4) Å and c=3.7800(2) Å. The antimony and excess oxygen occupy the hexagonal channels within the network of corner–sharing WO 6 octahedra. h –Sb x WO 3+2 x has a resistivity of ρ 300 K ≈1.28 mΩ cm at room temperature, with little if any temperature–dependence on cooling. DFT calculations on a simplified model for this compound find a metallic–like electronic structure with the Fermi level falling within rather flat bands, especially around the Γ point.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Formation and characterization of hydride rim structures in Zircaloy-4 nuclear fuel cladding tubes

Zirconium alloy tubes used as nuclear fuel cladding are subject to oxidation and subsequent hydrogen pickup during their long service in commercial light water reactors. The hydrogen picked up in the cladding can precipitate as a brittle hydride rim feature on the cladding outer surface. Here, to better understand the effect of hydride rims on the fracture behavior of stress-relieved zirconium alloy cladding tubes, a procedure to produce these rim-like structures has been developed and is described herein. Extensive characterization of the ‘as hydrided’ tubes is performed. The hydrogen charging apparatus consists of a tube furnace with a quartz chamber that is connected to a vacuum pump as well as a bottle of pure hydrogen gas. The charging station uses a static charge of hydrogen as opposed to a flowing gas. The chief advantage of this approach is the ability to monitor the pressure drop in the hydriding chamber and correlate this pressure drop to a known rate of hydrogen pickup in the cladding tube. It was found that the hydrogen partial pressure, metal temperature, and surface treatment all clearly played a role in whether a hydride rim was formed. Extensive characterization of the hydride rims shows they consist of needle like platelets of δ phase hydrides (ZrH1.66) oriented in the circumferential direction with a radial spacing of several microns in a sandwich-like structure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Automated Atom Probe Tomography capability to study the influence of applied voltage and laser power on the final apparent composition of the analyzed specimen

This study presents the development and implementation of an autonomous Bayesian optimization (BO) framework for controlling and optimizing experimental parameters in Atom Probe Tomography (APT). Using commercial silicon needle samples as a benchmark system, we demonstrate that BO can efficiently navigate the complex parameter space of voltage and laser power to achieve target charge state ratios (specifically Si + /(Si + +Si 2+ )) with minimal experimental evaluations. Our implementation integrates Gaussian Process modeling with the CAMECA atom probe control framework, enabling autonomous adjustment of experimental conditions in real-time. Results show that the algorithm successfully converges to target ratios under different scenarios: maintaining a reference ratio, increasing the ratio (favoring Si 1+ ), and decreasing the ratio (favoring Si 2+ ). The system adapts to specimen evolution during analysis, compensating for changes in apex geometry while maintaining optimization targets. This work establishes a proof of concept for AI-driven optimization in APT, addressing the traditional challenges of manual parameter tuning and paving the way for applications to more complex materials where compositional accuracy is critical.

36 MATERIALS SCIENCE↗