Hollow cathode plasma source for active spacecraft charge control
A prototype plasma source spacecraft discharge device has been developed to control overall and differential spacecraft surface charging. The plasma source is based on a unique hollow cathode discharge, where the plasma generation process is contained completely within the cathode. This device can be operated on argon, krypton, or xenon and has a rapid cold start time of less than 4 s. The discharge system design includes a spacecraft-discharge/net-charge sensing circuit which provides the ability to measure the polarity, magnitude, pulse shape, and time duration of a discharging event. Ion currents of up to 325 microA and electron currents ranging from 0.02 to 6.0 A have been extracted from the device. In addition, the spacecraft discharge device successfully discharged capacitively biased plates, from as high as + or - 2500 V, to ground potential, and discharged and clamped actively biased plates at +5 V with respect to ground potential during ground simulation testing.