Guidelines for Home Energy Professionals: Standard Work Specifications (SWS) Maintenance Charter and Procedures
This Standard Work Specifications (SWS) Maintenance Charter and Procedures outlines the policies and procedures for SWS.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This Standard Work Specifications (SWS) Maintenance Charter and Procedures outlines the policies and procedures for SWS.
This fact sheet provides essential information about the 2011 publication of the Workforce Guidelines for Multifamily Home Energy Upgrades, including their origin, their development with the help of industry leaders to create the standard work specifications for retrofit work.
This document provides the rationale for the specifications for the standardized transportation, aging, and disposal (STAD) canister systems provided in Performance Specification for Standardized Transportation, Aging, and Disposal Canister Systems, FCRD-NFST-2014-000579, Rev. 2, referred to as STAD Spec herein. The STAD Spec was developed to support STAD canister system studies and potential research, development, and demonstration activities. Requirements in the specification may evolve with time based on results from analyses, experiments, design studies, system evaluations and demonstrations, as well as other factors. The STAD canister system consists of a canister, together with a storage or aging overpack/module/vault, a shielded transfer cask (STC), a site transporter, a transportation overpack, and a transportation skid. Three sizes of circular cross section STAD canister variants are specified. The small STAD canister capacity is four pressurized water reactor (PWR) or nine boiling water reactor (BWR) spent nuclear fuel (SNF) assemblies. The medium STAD canister capacity is 12 PWR or 32 BWR SNF assemblies. The large STAD canister capacity is 21 PWR or 44 BWR SNF assemblies. There are 60 specifications in the STAD Spec that cover the STAD canister general design attributes, canister safety functional requirements, operational considerations, materials, storage and aging system requirements, and transportation system requirements. The 60 specifications are derived from regulatory requirements, regulatory guidance, STAD canister disposability considerations, and interim storage facility (ISF) and geologic repository handling facility considerations.
The U.S. Department of Energy (DOE), the National Renewable Energy Laboratory (NREL) and numerous industry stakeholders developed the Standard Work Specifications for Single-Family Home Energy Upgrades to define the minimum requirements for high-quality residential energy upgrades. Today, the Standard Work Specifications provide a unique source for defining high-quality home energy upgrades,establishing clear expectations for homeowners, contractors, trainers, workers, program administrators, and organizations that provide financing for energy upgrades.
This performance specification document addresses use of a standardized transportation, aging, and disposal (STAD) canister system in the spent nuclear fuel (SNF) waste management system. This document was developed to support STAD canister system studies and potential research, development, and demonstration activities. Requirements in this specification may evolve with time based on results from analyses, experiments, design studies, system evaluations and demonstrations, as well as other factors. A STAD canister system consists of a canister, together with a storage or aging overpack/module/vault, a shielded transfer cask (STC), a site transporter, a transportation overpack, and a transportation skid. Three sizes of circular cross section STAD canister variants are specified in this document. The small STAD canister capacity is four pressurized water reactor (PWR) or nine boiling water reactor (BWR) SNF assemblies. The medium STAD canister capacity is 12 PWR or 32 BWR SNF assemblies. The large STAD canister capacity is 21 PWR or 44 BWR SNF assemblies. Using standardized canisters for SNF facilitates the interface between storage at an independent spent fuel storage installation (ISFSI) or a DOEowned interim storage facility (ISF), transportation between facilities, and disposal at a repository. Multiple STAD canisters may be stored in a single storage overpack and/or a single transportation overpack. The US Nuclear Regulatory Commission (NRC) requirements currently used for storage and transportation are adopted for the STAD canister system. Approved approaches (guidance) in NRC storage and transportation documents are also adopted as requirements for the STAD canister system to facilitate obtaining NRC Certificates of Compliance (CoCs) for STAD canister systems. Performance specifications in this document are also informed by STAD canister disposability in various geologic media and consideration of ISF (and geologic repository) handling facility design, operations, and licensing requirements.
Cantilevered highway Variable Message Signs (VMS, also referred to as CMS, Changeable Message Signs, in latest design specifications) are potentially vulnerable to vibration caused by gusts from wind or that from truck-induced air flow. An example of such a vibration scenario was a VMS on State Route 17 in northern New Jersey, which was reported to experience large amplitude vertical displacements at the end of the cantilever. Reported vibration displacements ranged from the neighborhood of one to two feet to approximately four feet at the tip of the cantilever. This prompted the New Jersey Department of Transportation to take down the VMS and to support the structure to protect the safety of motorists. At the time of the New Jersey State Route 17 VMS vibration episodes, the AASHTO Standard Specifications for Structural Supports for Highway Signs, Luminaires, and Traffic Signals (referred to as Standard Specifications hereinafter) did not offer much guidance in the design for fatigue. It was also limited in instructions for VMS supporting structures, which might have produced some faulty designs. The sixth edition of the Standard Specifications indicated that the vibration problem is commonly associated with a large projected area in the horizontal plane and a vertical gust pressure created by truck passage under the VMS. An equivalent static gust pressure from trucks, PTG, is given for design purpose. A drag coefficient of 1.7 associated with the truck velocity VT is used in the calculation of PTG with an indication that it is an interim value before more research is completed to obtain a better coefficient. The study presented in this report was done to gain a better understanding of the aerodynamic properties of VMS and supporting structures, the dynamic characteristics of truck-induced gust pressure, and the potential for wind-truck-structure interaction that may produce significant vibration episodes for the VMS structures.
The U.S. has designed, constructed, and operated several sodium fast reactors (SFRs). To support these efforts and to document best practices, activities associated with the development of standards and consensus standards were carried out, however, the vast majority of those SFR standards are currently in a withdrawn or inactive status. Consensus standards are useful during design and licensing of reactors, as is evident in the current nuclear power generation fleet. Consensus standards provide certainty and predictability between stakeholders during licensing and other regulatory interactions. These standards offer guidance, reflect expert positions, and establish effective practices for a wide range of topics. Consensus standards are developed by committees with representation from a broad cross-section of industry, organizations, professional societies, and government agencies. However, most existing consensus standards applicable to nuclear power plants were developed specifically for light-water reactor (LWR) designs and may not adequately address specific advanced non-LWR design topics such as those related to SFRs.
The SWS were built by industry, for industry, and DOE and NREL facilitated the process to create them. The goal of the SWS maintenance process is to continue the consensus-based engagement to ensure the SWS content remains a relevant resource for promoting industry- accepted practices and maintaining consistency throughout the industry. This SWS Maintenance Charter and Procedures document defines the SWS maintenance process to provide transparency to stakeholders in how the SWS are maintained.
A middle distillate algal oil blend and red diesel algal oil blend from Sapphire Energy, Inc. were hydrotreated and distilled. The middle distillate feedstock blend was 8.0 wt.% biocrude and 92.0 wt.% middle distillate. The red diesel feedstock blend was 12.6 wt.% biocrude and 87.4 wt.% red diesel. During steady state, 151.4 kilograms of hydrotreated middle distillate/algal oil blend product was collected. During steady state, 312.6 kilograms of red diesel/algal oil blend hydrotreated product was collected. From the liquid product of the hydrotreated middle distillate/algal oil blend, 9.75 wt.% of the jet fuel cut is estimated to be from the algal oil. From the liquid product of the hydrotreated red diesel/algal oil blend, 11.3 wt.% of the diesel cut is estimated to be from the algal oil. The jet fuel cut of the middle distillate algal oil blend hydrotreated liquid product was analyzed using ASTM D1655, Standard Specification for Aviation Turbine Fuels. The diesel cut of the red diesel algal oil blend hydrotreated liquid product was analyzed using ASTM D975, Standard Specification for Diesel Fuel Oils.
A Management System may be defined as a set of standardized and interrelated practices that aim to improve effectiveness and produce better results. This system should be structured in such a way as to allow essential information to flow properly within the organization, including technical, administrative, production and human resources information, among others, within an adopted compliance model. There are, currently, several standards and guidelines for structuring a compliance model related to a management system. A system that covers various aspects of management in a single system is usually called integrated. Only the International Atomic Energy Agency - IAEA has a guide with this approach for radioactive waste: GS-G-3.3, 'The Management System for the Processing, Handling and Storage of Radioactive Waste' and GS-G-3.4, 'The Management System for the Disposal of Radioactive Waste'. The objective of this work is to present a comparison between existing standards, even if not specific for the management of radioactive waste, but which are widely used by companies. In due course, the result of this work will be object of proposal for specific standard to be presented to regulatory agency for this type of activity. This study should be useful for countries where there are no specific guidelines by the regulatory agency, adopting the best standard or guide as a conformity standards, creating and establishing a hybrid structure best suited to the safety and security aspects of the local culture. (authors)
The United States (US), with its 50-year experience in developing deep geologic disposal for transuranic waste, spent nuclear fuel (SNF), and high-level radioactive waste (HLW), has much to share with other countries. Yet, other countries are better able to translate the US experience and corresponding policy decisions into solutions sensible for their country when they understand the compliance requirements in US laws and regulations. This paper presents past approaches in the generic and site-specific standards of the US Environmental Protection Agency (EPA) and implementing regulations of the US Nuclear Regulatory Commission (NRC) using the framework provided by (1) key questions of the Blue Ribbon Commission on America’s Nuclear Future, and (2) international consensus standards. Both the 1985 EPA generic standards, as updated in 1993 and applied at the operating Waste Isolation Pilot Plant in southern New Mexico for transuranic waste from atomic energy defense activities, and the EPA 2008 site-specific standards and implementing regulations, as applied at the proposed Yucca Mountain repository in southern Nevada for SNF and HLW, adopt the strategy of using quantitative, probabilistic analysis to assess performance and compliance.
Hydropower is an established, affordable renewable energy generation technology supplying nearly 18% of the electricity consumed globally. A hydropower facility interacts continuously with the surrounding water resource environment, causing alterations of varying magnitude in the natural flow of water, energy, fish, sediment, and recreation upstream and downstream. A universal challenge in facility design is balancing the extraction of useful energy and power system services from a stream with the need to maintain ecosystem processes and natural environmental function. On one hand, hydroelectric power is a carbon-free, renewable, and flexible asset to the power system. On the other, the disruption of longitudinal connectivity and the artificial barrier to aquatic movement created by hydraulic structures can produce negative impacts that stress fresh water environments. The growing need for carbon-free, reliable, efficient distributed energy sources suggests there is significant potential for hydropower projects that can deploy with low installed costs, enhanced ecosystem service offerings, and minimal disruptions of the stream environment.
Reagents and methods are provided that permit simultaneous analysis of multiple diverse small molecule analytes present in a complex mixture. Samples are labeled with chemically identical but isotopically distince forms of the labeling reagent, and analyzed using mass spectrometry. A single reagent simultaneously derivatizes multiple small molecule analytes having different reactive functional groups.
Explore the source record for details and available documents.
The SWS are a free online tool and industry guide that defines the minimum acceptable outcomes for home energy upgrades installed on single-family, multifamily, and manufactured housing.
This document provides an overview of intentional islands, otherwise known as microgrids. The topics covered include common types of microgrid configurations, high level summaries of standards that address some aspect of microgrid implementation and interconnection, and a discussion of specific standards that apply during specific the islanding operational stages of parallel operation, transition to islanding, islanding operation and transition back to parallel operation.
Aviation turbine engine fuel specifications are governed by ASTM International, formerly known as the American Society for Testing and Materials (ASTM) International, and the British Ministry of Defence (MOD). ASTM D1655 Standard Specification for Aviation Turbine Fuels and MOD Defence Standard 91-91 are the guiding specifications for this fuel throughout most of the world. Both of these documents rely heavily on the vast amount of experience in production and use of turbine engine fuels from conventional sources, such as crude oil, natural gas condensates, heavy oil, shale oil, and oil sands. Turbine engine fuel derived from these resources and meeting the above specifications has properties that are generally considered acceptable for fuels to be used in turbine engines. Alternative and synthetic fuel components are approved for use to blend with conventional turbine engine fuels after considerable testing. ASTM has established a specification for fuels containing synthesized hydrocarbons under D7566, and the MOD has included additional requirements for fuels containing synthetic components under Annex D of DS91-91. New turbine engine fuel additives and blend components need to be evaluated using ASTM D4054, Standard Practice for Qualification and Approval of New Aviation Turbine Fuels and Fuel Additives. This paper discusses these specifications and testing requirements in light of recent literature claiming that some biomass-derived blend components, which have been used to blend in conventional aviation fuel, meet the requirements for aviation turbine fuels as specified by ASTM and the MOD. The 'Table 1' requirements listed in both D1655 and DS91-91 are predicated on the assumption that the feedstocks used to make fuels meeting these requirements are from approved sources. Recent papers have implied that commercial jet fuel can be blended with renewable components that are not hydrocarbons (such as fatty acid methyl esters). These are not allowed blend components for turbine engine fuels as discussed in this paper.
The water content of bio-oils is a key metric for several reasons. Water is typically the most concentrated single component of fast pyrolysis oils, though this will be much lower in catalytic fast pyrolysis and upgraded products. Reduced water content is preferable in bio-oil as water can contribute to phase separation, corrosivity, and instability. Additionally, lower water is beneficial for physical properties such as energy density. The percentage of water can also be used to correct the calculation for organic oxygen when determining total oxygen content of bio-oils via combustion-based ultimate analysis. The procedure described here is specifically written for the analysis of bio-oils, and is based on ASTM E203, Standard Test Method for Water Using Volumetric Karl Fischer Titration. This standard test method is specified for measuring the mass % water in pyrolysis liquid biofuels in ASTM D7544, Standard Specification for Pyrolysis Liquid Biofuel. Although the standard method is prescribed for the analysis of pyrolysis liquids for use in industrial and commercial burners, the method is not specifically written for this product. The method described with this Laboratory Analytical Procedure (LAP) provides specific guidance for the analysis of bio-oils. Both organic and aqueous phases can be measured with this technique.