Specimen Holder Design Improves Accuracy of X-Ray Powder Analysis

Specimen holder for X ray diffraction analysis presents the specimen to the incident X rays in a curvature. This permits the use of an X ray beam having a larger divergence angle, the beam intensity is increased, and the statistical accuracy of analysis is improved.

Mack, M.↗

Specimen Holder for Analytical Electron Microscopes

Reduces spectral contamination by spurious X-ray. Specimen holder made of compressed carbon, securely retains standard electron microscope grid (disk) 3 mm in diameter and absorbs backscattered electrons that otherwise generate spurious X-rays. Since holder inexpensive, dedicated to single specimen when numerous samples examined.

Clanton, U. S.↗

Specimen Holder For Flammability Tests

Fixture holds sheet specimens for flammability tests. Frame and clamps designed to minimize local overstress on specimen. Heat capacity of fixture low, interfering less with interpretation of results of test by drawing less heat away from specimen. Accepts films, fabrics, foams, and other sheets, rigid or flexible. Specimens thin or thick, or of variable thickness. Bent to accommodate curved rigid specimens. Also used for such other tests as particle-impact tests.

Rucker, Michelle A.↗

Mode-II-Fracture Specimen And Holder

Test specimen and loading frame developed for fatigue and fracture testing of materials under mode-II (sliding-mode) loading. Assembly placed in compression-testing machine. Loads directed oppositely along centerline cause self-similar crack to propagate. Enables consistently accurate alignment of specimens before insertion of specimen/frame assemblies into compression-testing machine. Makes design attractive for testing in hostile environments in which access to machine or furnace limited. Additional feature, with little or no modification, placed horizontally into impact testing machine and subjected to loading at high speeds.

Buzzard, Robert J.↗

ECAR-1943 AGC-1 INDIVIDUAL SPECIMEN FLUENCE, TEMPERATURE, AND LOAD CALCULATION AND TABULATION

This ECAR calculates the fluence and temperature of the AGC-1 specimens as they change elevation through the course of the experiment. The specimen elevation varies as the specimen stack shrinks due to irradiation and load induced creep. The compressed specimen stacks (S-1 thru S-6) have a graphite pushrod that applies a gas cylinder load. The top of the pushrod position is measured and recorded in the NGNP Data Management and Analysis System (NDMAS). The bottom of each of these compressed stacks is supported by the lower specimen holder which also shrinks as a result of irradiation and load. The specimen holder post-irradiation length was recorded during post-irradiation examination (PIE). Assuming the specimen holder shrinkage is linear with respect to the fluence received, the position of the top of the specimen holder can be calculated with respect to reactor integrated power. Assuming that individual specimen shrinkage is proportional to the fluence received, and that the shrinkage behavior is similar in all the specimens, the individual specimen position can be calculated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Motorized manipulator for positioning a TEM specimen

The invention relates to a motorized manipulator for positioning a TEM specimen holder with sub-micron resolution parallel to a y-z plane and rotating the specimen holder in the y-z plane, the manipulator comprising a base (2), and attachment means (30) for attaching the specimen holder to the manipulator, characterized in that the manipulator further comprises at least three nano-actuators (3.sup.a, 3.sup.b, 3.sup.c) mounted on the base, each nano-actuator showing a tip (4.sup.a, 4.sup.b, 4.sup.c), the at least three tips defining the y-z plane, each tip capable of moving with respect to the base in the y-z plane; a platform (5) in contact with the tips of the nano-actuators; and clamping means (6) for pressing the platform against the tips of the nano-actuators; as a result of which the nano-actuators can rotate the platform with respect to the base in the y-z plane and translate the platform parallel to the y-z plane.

Schmid, Andreas Karl↗

Vacuum Chuck Holds Filter Pad For Counting Particles

Microscope-stage holder keeps filter pad flat to keep it in focus. Specimen holder is special vacuum chuck that applies suction through flat screen. Suction keeps filter pad flat against specimen holder while microscope stage moving to scan areas denoted by grid. In microscope system equipped with video camera, image-analyzing/particle-counting computer, and automatic focus, use of stage speeds count considerably by eliminating need to stop frequently for manual refocusing. Technician free to perform other tasks while computer controls translation of stage and takes count automatically.

Berry, Anthony↗

Report on the Installation and Preparedness of a Protochips Fusion in-situ Heating Holder for TEM

This brief report documents the procurement and installation of a Protochips Fusion (formerly Aduro) high-temperature, high stability transmission electron microscopy (TEM) specimen holder that allows for the high spatial resolution characterization of material specimens at high temperature in situ of an electron microscope. This specimen holder was specifically procured for use with The FEI Talos F200X Scanning/Transmission Electron Microscope (STEM) in Oak Ridge National Laboratory’s (ORNL’s) Low Activation Materials Development and Analysis (LAMDA) Laboratory. The Protochips Fusion holder will enable high-resolution structural and chemical analysis of irradiated materials at high temperature, becoming a unique capability worldwide, and would encourage high-quality in situ experiments to be conducted on irradiated materials.

47 OTHER INSTRUMENTATION↗

Specimen and Holder for Sliding-Mode Fatigue Tests

Single-ended notch design facilitates accurate measurements of crack progression. Novel test specimen and novel loading fixture and fracture testing of materials under Mode II, or sliding-mode, loading. Testing required for analysis of failures in structural materials, bearings, and the like.

Buzzard, R. J.↗

3-D Manipulator for Mass Spectrometer

Small mass-spectrometer specimens are positioned in three dimensions by manipulator that employs two bellows to provide vacuum seal and accommodate movement of specimen holder. Inner bellows and outer bellows accommodate vertical and horizontal motion, respectively. Y-axis movement is in and out of plane of page. Specimen-holder column is hollow so electrical wires can pass through it to specimen.

Cirner, J. C.↗

Ultracold cryogenic TEM with liquid helium and high stability

Cryogenic transmission electron microscopy has revolutionized structural biology and materials science. To image below liquid nitrogen temperatures, various liquid helium stages have been constructed but have proven to be complex and unstable, making high-resolution imaging challenging. This problem is even more pronounced in side-entry specimen holders common on modern transmission electron microscopes. Here, we introduce an ultracold liquid helium transmission electron microscope side-entry specimen holder, featuring continuous cryogen flow and vibration decoupling. This instrument is compatible with modern aberration-corrected microscopes and achieves sub-25 K base temperature, ±2 mK thermal stability over many hours, and atomic resolution—setting the stage for a new era of cryogenic electron microscopy.

42 ENGINEERING↗

Off-axis electron holography of bacterial cells and magnetic nanoparticles in liquid

Here, the mapping of electrostatic potentials and magnetic fields in liquids using electron holography has been considered to be unrealistic. Here, we show that hydrated cells of Magnetospirillum magneticum strain AMB-1 and assemblies of magnetic nanoparticles can be studied using off-axis electron holography in a fluid cell specimen holder within the transmission electron microscope. Considering that the holographic object and reference wave both pass through liquid, the recorded electron holograms show sufficient interference fringe contrast to permit reconstruction of the phase shift of the electron wave and mapping of the magnetic induction from bacterial magnetite nanocrystals. We assess the challenges of performing in situ magnetization reversal experiments using a fluid cell specimen holder, discuss approaches for improving spatial resolution and specimen stability, and outline future perspectives for studying scientific phenomena, ranging from interparticle interactions in liquids and electrical double layers at solid–liquid interfaces to biomineralization and the mapping of electrostatic potentials associated with protein aggregation and folding.

36 MATERIALS SCIENCE↗

In Situ Measurement of Ground-Surface Flow Resistivity

New instrument allows in situ measurement of flow resistivity on Earth's ground surface. Nonintrusive instrument includes specimen holder inserted into ground. Flow resistivity measured by monitoring compressed air passing through flow-meters; pressure gages record pressure at ground surface. Specimen holder with knife-edged inner and outer cylinders easily driven into ground. Air-stream used in measuring flow resistivity of ground enters through quick-connect fitting and exits through screen and venthole.

Zuckerwar, A. J.↗

Effects of specimen preparation on the electromagnetic property measurements of solid materials with an automatic network analyzer

Effects of specimen preparation on measured values of an acrylic's electomagnetic properties at X-band microwave frequencies, TE sub 1,0 mode, utilizing an automatic network analyzer have been studied. For 1 percent or less error, a gap between the specimen edge and the 0.901-in. wall of the specimen holder was the most significant parameter. The gap had to be less than 0.002 in. The thickness variation and alignment errors in the direction parallel to the 0.901-in. wall were equally second most significant and had to be less than 1 degree. Errors in the measurement f the thickness were third most significant. They had to be less than 3 percent. The following parameters caused errors of 1 percent or less: ratios of specimen-holder thicknesses of more than 15 percent, gaps between the specimen edge and the 0.401-in. wall less than 0.045 in., position errors less than 15 percent, surface roughness, hickness variation in the direction parallel to the 0.401-in. wall less than 35 percent, and specimen alignment in the direction parallel to the 0.401-in. wall mass than 5 degrees.

Long, E. R., Jr.↗