ECAR-1943 AGC-1 INDIVIDUAL SPECIMEN FLUENCE, TEMPERATURE, AND LOAD CALCULATION AND TABULATION

This ECAR calculates the fluence and temperature of the AGC-1 specimens as they change elevation through the course of the experiment. The specimen elevation varies as the specimen stack shrinks due to irradiation and load induced creep. The compressed specimen stacks (S-1 thru S-6) have a graphite pushrod that applies a gas cylinder load. The top of the pushrod position is measured and recorded in the NGNP Data Management and Analysis System (NDMAS). The bottom of each of these compressed stacks is supported by the lower specimen holder which also shrinks as a result of irradiation and load. The specimen holder post-irradiation length was recorded during post-irradiation examination (PIE). Assuming the specimen holder shrinkage is linear with respect to the fluence received, the position of the top of the specimen holder can be calculated with respect to reactor integrated power. Assuming that individual specimen shrinkage is proportional to the fluence received, and that the shrinkage behavior is similar in all the specimens, the individual specimen position can be calculated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Motorized manipulator for positioning a TEM specimen

The invention relates to a motorized manipulator for positioning a TEM specimen holder with sub-micron resolution parallel to a y-z plane and rotating the specimen holder in the y-z plane, the manipulator comprising a base (2), and attachment means (30) for attaching the specimen holder to the manipulator, characterized in that the manipulator further comprises at least three nano-actuators (3.sup.a, 3.sup.b, 3.sup.c) mounted on the base, each nano-actuator showing a tip (4.sup.a, 4.sup.b, 4.sup.c), the at least three tips defining the y-z plane, each tip capable of moving with respect to the base in the y-z plane; a platform (5) in contact with the tips of the nano-actuators; and clamping means (6) for pressing the platform against the tips of the nano-actuators; as a result of which the nano-actuators can rotate the platform with respect to the base in the y-z plane and translate the platform parallel to the y-z plane.

Schmid, Andreas Karl↗

Report on the Installation and Preparedness of a Protochips Fusion in-situ Heating Holder for TEM

This brief report documents the procurement and installation of a Protochips Fusion (formerly Aduro) high-temperature, high stability transmission electron microscopy (TEM) specimen holder that allows for the high spatial resolution characterization of material specimens at high temperature in situ of an electron microscope. This specimen holder was specifically procured for use with The FEI Talos F200X Scanning/Transmission Electron Microscope (STEM) in Oak Ridge National Laboratory’s (ORNL’s) Low Activation Materials Development and Analysis (LAMDA) Laboratory. The Protochips Fusion holder will enable high-resolution structural and chemical analysis of irradiated materials at high temperature, becoming a unique capability worldwide, and would encourage high-quality in situ experiments to be conducted on irradiated materials.

47 OTHER INSTRUMENTATION↗

Ultracold cryogenic TEM with liquid helium and high stability

Cryogenic transmission electron microscopy has revolutionized structural biology and materials science. To image below liquid nitrogen temperatures, various liquid helium stages have been constructed but have proven to be complex and unstable, making high-resolution imaging challenging. This problem is even more pronounced in side-entry specimen holders common on modern transmission electron microscopes. Here, we introduce an ultracold liquid helium transmission electron microscope side-entry specimen holder, featuring continuous cryogen flow and vibration decoupling. This instrument is compatible with modern aberration-corrected microscopes and achieves sub-25 K base temperature, ±2 mK thermal stability over many hours, and atomic resolution—setting the stage for a new era of cryogenic electron microscopy.

42 ENGINEERING↗

Off-axis electron holography of bacterial cells and magnetic nanoparticles in liquid

Here, the mapping of electrostatic potentials and magnetic fields in liquids using electron holography has been considered to be unrealistic. Here, we show that hydrated cells of Magnetospirillum magneticum strain AMB-1 and assemblies of magnetic nanoparticles can be studied using off-axis electron holography in a fluid cell specimen holder within the transmission electron microscope. Considering that the holographic object and reference wave both pass through liquid, the recorded electron holograms show sufficient interference fringe contrast to permit reconstruction of the phase shift of the electron wave and mapping of the magnetic induction from bacterial magnetite nanocrystals. We assess the challenges of performing in situ magnetization reversal experiments using a fluid cell specimen holder, discuss approaches for improving spatial resolution and specimen stability, and outline future perspectives for studying scientific phenomena, ranging from interparticle interactions in liquids and electrical double layers at solid–liquid interfaces to biomineralization and the mapping of electrostatic potentials associated with protein aggregation and folding.

36 MATERIALS SCIENCE↗

In-situ heating-and-electron tomography for materials research: from 3D ( In-situ 2D) to 4D ( In-situ 3D)

In-situ observation has expanded the application of transmission electron microscopy (TEM) and has made a significant contribution to materials research and development for energy, biomedical, quantum, etc. Recent technological developments related to in-situ TEM have empowered the incorporation of three-dimensional observation, which was previously considered incompatible. In this review article, we take up heating as the most commonly used external stimulus for in-situ TEM observation and overview recent in-situ TEM studies. Then, we focus on the electron tomography (ET) and in-situ heating combined observation by introducing the authors’ recent research as an example. Assuming that in-situ heating observation is expanded from two dimensions to three dimensions using a conventional TEM apparatus and a commercially available in-situ heating specimen holder, the following in-situ heating-and-ET observation procedure is proposed: (i) use a rapid heating-and-cooling function of a micro-electro-mechanical system holder; (ii) heat and cool the specimen intermittently and (iii) acquire a tilt-series dataset when the specimen heating is stopped. This procedure is not too technically challenging and can have a wide range of applications. Essential technical points for a successful 4D (space and time) observation will be discussed through reviewing the authors’ example application.

36 MATERIALS SCIENCE↗

In-situ TEM Holder for Ultrafast, Multimodal Imaging

This project developed a prototype in-situ specimen holder product to transmission electron microscope (TEM) users that drastically expand the usability of TEM by combining nanoscale laser excitation and optical signal collection. A commercial prototype has been constructed and a few nanoscale materials characterization experiments have been performed to validate its performance and demonstrate its utility in real scientific studies, for example, in-situ characterization and mapping of defects in the synthesis of nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An On-Axis Tomography Holder for Correlative Electron and Atom Probe Microscopy

This document briefly outlines the procurement and commissioning of a Fishione Model 2050 on-axis rotational tomography specimen holder for the FEI F200X Talos Scanning Transmission Electron Microscope in Oak Ridge National Laboratory’s Low Activation Materials Development and Analysis (LAMDA) Laboratory. The Model 2050 specimen rod was successfully procured and commissioned and is now available to users.

47 OTHER INSTRUMENTATION↗

Isothermal Martensitic and Pressure-Induced Delta to Alpha-Prime Phase Transformations in a Pu-Ga Alloy

A well-homogenized Pu-2 at.% Ga alloy can be retained in the metastable face-centered cubic {delta} phase at room temperature. Ultimately, this metastable {delta} phase will decompose via a eutectoid transformation to the thermodynamically stable monoclinic {alpha} phase and the intermetallic compound Pu{sub 3}Ga over a period of approximately 10,000 years [1]. In addition, these low solute-containing {delta}-phase Pu alloys are metastable with respect to an isothermal martensitic phase transformation to the {alpha}{prime} phase during low temperature excursions [2, 3] and are also metastable with respect to a {delta} {yields} {alpha}{prime} phase transformation with increases in pressure [3-5]. The low temperature {delta} {yields} {alpha}{prime} isothermal martensitic phase transformation in the Pu-2 at.% Ga alloy only goes to {approx}25% completion with the resultant {approx}20 {micro}m long by 2 {micro}m wide lath-shaped {alpha}{prime} particles dispersed within the {delta} matrix. In recently reported studies, Faure et al. [4] have observed a {delta} {yields} {gamma} {yields} {alpha}{prime} pressure-induced phase transformation sequence during a diamond anvil cell investigation and, based on x-ray diffraction and density and compressibility experiments, Harbur [5] has concluded that both {alpha}{prime} and an amorphous phase are present in samples that were pressurized and recovered. In this work, a large volume moissanite anvil cell is constructed to permit the pressurization and recovery of specimens of a size suitable for TEM and electron diffraction studies. The cell, shown in Fig. 1, has an overall diameter of 101.6 mm, a moissanite anvil diameter of 9.00 mm, a culet size of 3 mm, and a spring steel gasket 0.5 mm thick with a hole diameter of 2.5 mm. A 2.3 mm diameter by 100 {micro}m thick sample of {delta}-phase Pu-2 at.% Ga is compressed at a rate of approximately 0.05 GPa/minute to {approx}1 GPa to induce the phase transformation to {alpha}{prime}. Optical microscopy of the recovered specimen reveals a very fine microstructure that appears to be single phase, although the resolution of this technique is insufficient to differentiate between single and multiple phases if the grain size is below approximately 1 {micro}m. X-ray diffraction, using a laboratory Cu K{sub {alpha}} source with wavelength of 1.542{angstrom}, shows the monoclinic reflections from the {alpha}{prime} phase, strong peaks from the aluminum specimen holder, and weak peaks from the face-centered cubic {delta} phase as shown in Fig. 2. The recovered specimen is prepared for TEM and electron diffraction studies as described in Moore et al. [6]. TEM reveals small regions of {delta} phase with a very high dislocation density interspersed between the 10-100's nm {alpha}{prime} grains as shown in Fig. 3. Electron diffraction, shown in the insert in Fig. 3, clearly reveals the presence of the {delta} phase. This microstructure is in contrast to the {alpha}{prime} particles that form as a result of the low-temperature isothermal martensite in which the {alpha}{prime} particles are lath-shaped and significantly larger as shown in the optical micrograph in Fig. 4 of a sample cooled to -120 C and held for 10 hours. In these preliminary results, there is no evidence of either an amorphous phase, as suggested by Harbur [5], or the presence of a {gamma} phase. We expected to observe an amorphous phase based on the similarity of this experiment to that of Harbur [5]. It is possible that the {gamma} phase, as reported by Faure et al. [4], does form as an intermediate, but it is not retained to ambient pressure.

36 MATERIALS SCIENCE↗

Quartz microbalance device for transfer into ultrahigh vacuum systems

An uncomplicated quartz microbalance device has been developed which is transferable into ultrahigh vacuum (UHV) systems. The device is extremely useful for flux calibration of different kinds of material evaporators. Mounted on a commercial specimen holder, the device allows fast quartz microbalance transfer into the UHV and subsequent positioning exactly to the sample location where subsequent thin film deposition experiments shall be carried out. After backtransfer into an UHV sample stage, the manipulator may be loaded in situ with the specimen suited for the experiment. The microbalance device capability is demonstrated for monolayer and submonolayer vanadium depositions with an achieved calibration sensitivity of less the 0.001 ML coverage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring New Science Domains with Atom Probe Tomography Enabled by an Environmental Transfer Hub

The liquid/solid and gas/solid interface represents a rich scientific and technological frontier for discovery and innovation in many areas of science. However, the direct nano- to atomic-scale characterization of these interfaces is technically challenging within broad range of analytical tools that require high to ultrahigh vacuum conditions. This challenge has been largely addressed within the electron microscopy (EM) community through the development of unique specimen holders and differentially-pumped vacuum systems that allow researchers to probe, in situ, liquid/solid and gas/solid interfaces using electron probes [1]. However, the direct application of APT to liquid/solid and gas/solid interfaces is not possible and requires the development of unique specimen preparation and handling of cryogenically-frozen specimens and/or work with specimens under environmentally-protected conditions. At PNNL, we have developed unique suite of hardware and experimental protocols for the preparation and handling of environmentally-sensitive materials centered around the combination of a unique environmental transfer hub, specimen suitcase device, and modified cryo FIB/SEM capabilities (Fig. 1a) [2-3]. The ability to prepare, manipulate, and transfer specimens under either cryogenic or vacuum conditions thus provides a means to uniquely apply APT analysis to a wide variety of material systems that would not be possible otherwise. Here we describe some specific examples, shown in Figure 1b, of APT analysis applied to temperature sensitive material systems requiring cryo specimen preparation and transfer, as well as air sensitive materials systems requiring vacuum or inert vacuum transfer.

Cryo atom probe tomography, Atom Probe, cryogenic ↗

Solid Particle Erosion Wear of GF/EP Composites with Added Al{sub 2}O{sub 3}

This study has targeted to investigate wear behavior of a sort of new composite material where Al{sub 2}O{sub 3}({approx_equal}150 {mu}m) particles were added to glass fiber and epoxy resin (GF/EP) at an amount of 15% and 30%. The method used in the tests, was the one that use dry and compressed air to accelerate abrasive particles onto a specimen and from there the wear formed was investigated. Striking speed was determined with the help of a double disc method by making use of pressure difference, whereas impinging angles were set by turning the specimen holder around its axis. As a result, in this experimental study, solid particle erosion behavior of a new formed composite material was investigated and erosion rates computed where three different impinging angles (30 deg., 60 deg. and 90 deg.), three different striking speeds (23, 34 and 53 m/s) and two different fiber directions (0 deg. and 45 deg.) were used to enable angular aluminum abrasives with average diameter of 400 {mu}m to bombard target specimens to undertake the tests. In addition, the study presents microscopic views of the specimens after undergoing the tests.

36 MATERIALS SCIENCE↗

Improvement of windowed type environmental-cell transmission electron microscope for in situ observation of gas-solid interactions

We have developed an improved, windowed type environmental-cell (E-cell) transmission electron microscope (TEM) for in situ observation of gas-solid interactions, such as catalytic reactions at atmospheric pressure. Our E-cell TEM includes a compact E-cell specimen holder with mechanical stability, resulting in smoother introduction of the desired gases compared with previous E-cell TEMs. In addition, the gas control unit was simplified by omitting the pressure control function of the TEM pre-evacuation chamber. This simplification was due to the successful development of remarkably tough thin carbon films as the window material. These films, with a thickness of <10 nm, were found to withstand pressure differences >2 atm. Appropriate arrangement of the specimen position inside the E-cell provided quantitatively analyzable TEM images, with no disturbances caused by the windowed films. As an application, we used this E-cell TEM to observe the dynamic shape change in a catalytic gold nanoparticle supported on TiO{sub 2} during the oxidation of CO gas.

36 MATERIALS SCIENCE↗

Microfluidic system for transmission electron microscopy

We present a microfluidic system that maintains liquid flow in a specimen chamber for (scanning) transmission electron microscope ((S)TEM) imaging. The specimen chamber consists of two ultra-thin silicon nitride windows supported by silicon microchips. They are placed in a specimen holder that seals the sample from the vacuum in the electron microscope, and incorporates tubing to and from the sample connected to a syringe pump outside the microscope. Using results obtained from fluorescence microscopy of microspheres flowing through the system, an equation to characterize the liquid flow through the system was calibrated. Gold nanoparticles of diameters of 30 and 100 nm moving in liquid were imaged with a 200 kV STEM. It was concluded that despite strong influences from Brownian motion, and sensitivity to small changes in the depth of the bypass channel, the electron microscopy flow data matched the calculated flow speed within an order of magnitude. The system allows for rapid (within a minute) liquid exchange, which can potentially be used, for example, to investigate the response of specimens, e.g., eukaryotic-, or bacterial cells, to certain stimuli.

99 GENERAL AND MISCELLANEOUS↗