Search NASA⌕ Search

SEARCH · Search NASA

Results for “specimen preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Influence of Specimen Preparation and Specimen Size on Composite Transverse Tensile Strength and Scatter

The influence of specimen polishing, configuration, and size on the transverse tension strength of two glass-epoxy materials, and one carbon-epoxy material, loaded in three and four point bending was evaluated. Polishing machined edges, arid/or tension side failure surfaces, was detrimental to specimen strength characterization instead of yielding a higher, more accurate, strength as a result of removing inherent manufacture and handling flaws. Transverse tension strength was typically lower for longer span lengths due to the classical weakest link effect. However, strength was less sensitive to volume changes achieved by increasing specimen width. The Weibull scaling law typically over-predicted changes in transverse tension strengths in three point bend tests and under-predicted changes in transverse tension strengths in four point bend tests. Furthermore, the Weibull slope varied with specimen configuration, volume, and sample size. Hence, this scaling law was not adequate for predicting transverse tension strength of heterogeneous, fiber-reinforced, polymer matrix composites.

OBrien, T. Kevin↗

Influence of Specimen Preparation and Specimen Size on the Transverse Tensile Strength and Scatter of Glass Epoxy Laminates

The influence of specimen polishing, specimen configuration, and specimen size on the transverse tension strength of two glass epoxy materials loaded in three and four point bending was evaluated. Polishing machined edges, and/or tension side failure surfaces, was detrimental to specimen strength characterization instead of yielding a higher, more accurate, strength as a result of removing inherent manufacture and handling flaws. Transverse tension strength was sensitive to span length due to the classical weakest link effect. However, strength was less sensitive to volume changes achieved by increasing specimen width. The Weibull scaling law over-predicted changes in transverse tension strengths in three point bend tests and under-predicted changes in transverse tension strengths in four point bend tests. Furthermore, the Weibull slope varied with specimen configuration, volume, and sample size. Hence, the utility of this scaling law for predicting transverse tension strength is unclear.

OBrien, T. Kevin↗

Effects of specimen preparation on the electromagnetic property measurements of solid materials with an automatic network analyzer

Effects of specimen preparation on measured values of an acrylic's electomagnetic properties at X-band microwave frequencies, TE sub 1,0 mode, utilizing an automatic network analyzer have been studied. For 1 percent or less error, a gap between the specimen edge and the 0.901-in. wall of the specimen holder was the most significant parameter. The gap had to be less than 0.002 in. The thickness variation and alignment errors in the direction parallel to the 0.901-in. wall were equally second most significant and had to be less than 1 degree. Errors in the measurement f the thickness were third most significant. They had to be less than 3 percent. The following parameters caused errors of 1 percent or less: ratios of specimen-holder thicknesses of more than 15 percent, gaps between the specimen edge and the 0.401-in. wall less than 0.045 in., position errors less than 15 percent, surface roughness, hickness variation in the direction parallel to the 0.401-in. wall less than 35 percent, and specimen alignment in the direction parallel to the 0.401-in. wall mass than 5 degrees.

Long, E. R., Jr.↗

Specimens Prepared for Materials International Space Station Experiment

The Materials International Space Station Experiment (MISSE) is a materials flight experiment sponsored by the Materials and Manufacturing Directorate of the Air Force Research Laboratory at Wright-Patterson Air Force Base and the NASA Space Environmental Effects Program at the NASA Marshall Space Flight Center. MISSE is a cooperative effort among the Air Force, several NASA field centers, and industry. The experiment package will be placed on the exterior of the International Space Station in the summer of 2001. Approximately half of the specimens will be exposed to the space environment for 1 year, and the other half will be exposed for 3 years. The Electro-Physics Branch at the NASA Glenn Research Center has prepared and delivered over 150 specimens to be included in MISSE. Specimens include: 1) Double-coated polyimide Kapton to compare mass loss from in-space atomic oxygen undercutting erosion to ground-laboratory atomic oxygen undercutting erosion for predicting in-space durability; 2) Silicones to study changes in surface hardness and optical properties after combined atomic oxygen--ultraviolet radiation exposure for predicting in-space durability; 3) Forty-one different polymers to accurately measure their atomic oxygen erosion yields; 4) Scattering chambers to study atomic oxygen scattering characteristics that are relevant to the degradation found in spacecraft with exterior openings; 5) Thin polymer film disks and tensile specimens to study the effects of radiation on their optical properties and mechanical properties; 6) Lightweight intercalated graphite epoxy composites to study electromagnetic interference shielding performance; and 7) Polymer-based materials utilizing new atomic oxygen protection concepts to study their durability.

Banks, Bruce A.↗

Innovative Nuclear Materials Outboard-A Project Specimen Preparation Guide

The Innovative Nuclear Materials (INM) Program was recently established by the U.S. Department of Energy (DOE) to develop advanced material technologies for use in nuclear reactors. The INM program is presently focused on researching in-core non-fueled materials for application in fast spectrum nuclear reactors. The widespread deployment of fast reactors continues to be a prominent aspiration for advanced nuclear technology developers. However, companies working to license these reactors have no choice but to rely on historic material technologies since further optimization and advancement of these materials is impeded by the lack of fast neutron irradiation test facilities. INM-OA is a non-fueled drop-in experiment which will irradiate material specimens of interest to fast reactor applications. This experiment will be irradiated at Idaho National Laboratory (INL) in the Advanced Test Reactor (ATR) outboard-A (OA) position during normal and high temperature steady state (HTSS) cycles. It will include material specimens supplied by members of the INM program and will utilize a cadmium-lined basket to filter out incident thermal neutrons, thus simulating a faster neutron energy spectrum. Material specimens will undergo post-irradiation examination including microscopy and mechanical testing. In addition to absorption reactions, fast neutrons cause microstructural damage in materials by atom displacement, which can cause exacerbated changes in physical properties and behavior. Thus, the data obtained from the INM-OA experiment will be crucial for understanding the engineering-scale behavior of reactor materials. This document is intended for the Principal Investigators providing samples for this project. Topics included are a general description of the experiment, the irradiation experiment/capsule design, sample geometries, number of samples to be provided, documentation to be provided, a brief list potentially useful characterization methods that can be leveraged at INL, and other miscellaneous requirements specific to this project. This document is intended for informational use only.

innovative nuclear materials↗

Survey of baffle plate samples, specimen machining, and hydrogen measurements

This report outlines preliminary results on the survey and characterization of irradiated baffle plate, baffle former, and flux thimble tube specimens as part of the ongoing investigation into irradiation-induced embrittlement in austenitic stainless steels at ambient (room temperature) conditions. The specimens originated from commercial pressurized water reactor (PWR) components, covering displacement damage doses ranging from approximately 0.065 to 75 dpa. Initial scanning electron microscopy (SEM) surveys revealed that specimen surfaces exhibited fine machining marks and in-service-formed oxide layers on the side surfaces of the analyzed specimens. The oxide layers revealed specific features resembling localized "pitting-like" corrosion. An additional set of specimens representing in-service oxidation is being preserved for future microstructure analysis work. As believed, this will provide additional insights into long-term material degradation in PRWs. Specimen machining challenges emerged due to a complex failure of the electric discharge machining (EDM) system located in hot area. Despite partial restoration, issues persist with the EDM’s secondary power supply, necessitating the exploration of alternative EDM or computer numerical control (CNC) machining approaches to facilitate tensile specimen preparation. Currently, low speed saw cutting is in progress to prepare specimens for hydrogen measurements and general microstructure analysis. The near-term goals include completing tensile specimen machining for advanced mechanical testing and characterizing fracture mechanisms, and stress-corrosion cracking testing, ultimately aiming to identify and mitigate the ambient-condition intergranular cracking through targeted post-irradiation annealing strategies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Carbon distribution profiles in lunar fines

Radial distribution profiles of elemental carbon in lunar soils consisting of particles in the size range of 50 to 150 microns were investigated. Initial experiments on specimen preparation and the analysis of prepared specimens by Auger electron spectrometry (AES) and scanning electron microscopy (SEM) are described. Results from splits of samples 61501,84 and 64421,11, which were mounted various ways in several specimen holders, are presented. A low carbon content was observed in AES spectra from soil particles that were subjected to sputter-ion cleaning with 960eV argon ions for periods of time up to a total exposure for one hour. This ion charge was sufficient to remove approximately 70 nm of material from the surface. All of the physically adsorbed carbon (as well as water vapor, etc.) would normally be removed in the first few minutes, leaving only carbon in the specimen, and metal support structure, to be detected thereafter.

Hart, R. K.↗

Bidirectional reflectance of zinc oxide

This investigation was undertaken to determine original and useful information about the bidirection reflectance of zinc oxide. The bidirectional reflectance will be studied for the spectra between .25-2.5 microns and the hemisphere above the specimen. The following factors will be considered: (1) surface conditions; (2) specimen preparation; (3) specimen substrate, (4) polarization; (5) depolarization; (6) wavelength; and (7) angles of incident and reflection. The bidirectional reflectance will be checked by experimentally determined angular hemispherical measurements or hemispherical measurements will be used to obtain absolute bidirectional reflectance.

Scott, R.↗

An Improved Technique for the Preparation of Mounted or Unmounted Carbon/Epoxy Specimens

As carbon/epoxy materials became more prevalent in the aerospace industry, microstructural analysis demanded specimen preparation techniques that led to better polished surfaces, achievable in a shorter time, and using fewer steps. The desire to use image analysis for material characterization also helped drive the goal for defect free surfaces. At NASA-Langley (LaRC), carbon/epoxy specimens had been historically prepared in 1 inch diameter Bakelite mounts. Carbon/epoxy specimens that were 1/8 to 1/4 inch thick were not affected by the heat and pressure required for mounting in Bakelite, however thinner specimens were crushed during mounting. A two-part room temperature curing epoxy was chosen as an alternative but sometimes voids developed between the specimen and the mounting material. This was prevented by either heating the epoxy to 140 degrees F to lower the viscosity of the epoxy or by using a vacuum impregnation apparatus. Both techniques helped facilitate flow and allowed the epoxy to penetrate crevices.

Edahl, Robert A., Jr.↗

Focused Ion Beam Recovery and Analysis of Interplanetary Dust Particles (IDPs) and Stardust Analogues

Meteoritics research is a major beneficiary of recent developments in analytical instrumentation [1,2]. Integrated studies in which multiple analytical techniques are applied to the same specimen are providing new insight about the nature of IDPs [1]. Such studies are dependent on the ability to prepare specimens that can be analyzed in multiple instruments. Focused ion beam (FIB) microscopy has revolutionized specimen preparation in materials science [3]. Although FIB has successfully been used for a few IDP and meteorite studies [1,4-6], it has yet to be widely utilized in meteoritics. We are using FIB for integrated TEM/NanoSIMS/synchrotron infrared (IR) studies [1].

Graham, G. A.↗

Preparation of Regular Specimens for Atom Probes

A method of preparation of specimens of non-electropolishable materials for analysis by atom probes is being developed as a superior alternative to a prior method. In comparison with the prior method, the present method involves less processing time. Also, whereas the prior method yields irregularly shaped and sized specimens, the present developmental method offers the potential to prepare specimens of regular shape and size. The prior method is called the method of sharp shards because it involves crushing the material of interest and selecting microscopic sharp shards of the material for use as specimens. Each selected shard is oriented with its sharp tip facing away from the tip of a stainless-steel pin and is glued to the tip of the pin by use of silver epoxy. Then the shard is milled by use of a focused ion beam (FIB) to make the shard very thin (relative to its length) and to make its tip sharp enough for atom-probe analysis. The method of sharp shards is extremely time-consuming because the selection of shards must be performed with the help of a microscope, the shards must be positioned on the pins by use of micromanipulators, and the irregularity of size and shape necessitates many hours of FIB milling to sharpen each shard. In the present method, a flat slab of the material of interest (e.g., a polished sample of rock or a coated semiconductor wafer) is mounted in the sample holder of a dicing saw of the type conventionally used to cut individual integrated circuits out of the wafers on which they are fabricated in batches. A saw blade appropriate to the material of interest is selected. The depth of cut and the distance between successive parallel cuts is made such that what is left after the cuts is a series of thin, parallel ridges on a solid base. Then the workpiece is rotated 90 and the pattern of cuts is repeated, leaving behind a square array of square posts on the solid base. The posts can be made regular, long, and thin, as required for samples for atom-probe analysis. Because of their small volume and regularity, the amount of FIB-milling time can be much less than that of the method of sharp shards. Individual posts can be broken off for mounting in a manner similar to that of the method of sharp shards. Alternatively, the posts can be left intact on the base and the base can be cut to a small square (e.g., 3 by 3 mm) suitable for mounting in an atom probe of a type capable of accepting multiple-tip specimens. The advantage of multiple-tip specimens is the possibility of analyzing many tips without the time-consuming interchange of specimens.

Kuhlman, Kim↗

Flash electropolishing for TEM: Reducing FIB‐induced defects in tungsten with protocols for new materials

Focused ion beam (FIB) milling has become the dominant approach for site-specific transmission electron microscopy (TEM) specimen preparation; however, FIB damage remains a critical limitation for reliable microstructural characterisation, particularly in radiation effects studies. Tungsten is especially susceptible to FIB damage due to its high nuclear stopping power, which promotes the formation and strong diffraction contrast of FIB-induced ‘black spot’ defects that are indistinguishable from very fine irradiation-induced loops/defects resulting from low to intermediate temperature neutron irradiation. In this work, flash electropolishing is systematically evaluated as a post-FIB treatment for minimising preparation-induced artefacts for TEM analysis of tungsten-based alloys. Using a range of non-, ion-, and neutron-irradiated tungsten materials, the effectiveness of flash electropolishing has been assessed through direct comparison with conventional FIB and plasma-FIB preparation including low-energy Ga, Ar, Xe ion cleaning. The results demonstrate that flash electropolishing effectively removes FIB-damaged layers and ‘black spot’ defects, thereby enabling reliable observation of irradiation-induced dislocation structures. Key processing parameters governing flash electropolishing quality – including lamella thickness, applied voltage, polishing duration, electrolyte chemistry, and cathode geometry – have been systematically evaluated, and clear criteria were established for determining when flash electropolishing is required to ensure reliable microstructural analysis. This work also provides practical guidance for implementing flash electropolishing as an artefact-controlled specimen-preparation approach for TEM characterisation of FIB-produced specimens. The systematic protocol can be extended to other, non-tungsten materials.

TEM sample preparation↗

Interpretation of Zerodur® Strength Data

Recent, detailed fractographic analysis of Zerodur® strength test specimens prepared by linear grinding and etching with a proprietary process indicated low frequency damage to be the strength limiting defects Recent, detailed fractographic analysis of Zerodur® strength test specimens prepared by linear grinding and etching with a proprietary process indicated low frequency damage to be the strength limiting defects [1]. The 2-parameter Weibull distribution is usually assumed when working with ceramic and glasses such as Zerodur®, although 3-parameter behavior is occasionally considered [2]. Detailed statistical modeling of the Zerodur® strength data with the was initial perspective of a 3-parameter Weibull distribution gave unsatisfying results [3]. The subsequent fractographic investigation indicated [1] that the usual assumption of many small, random, noninteracting flaws [4] was not represented, but instead, less frequent, aligned flaws along etching ridges parallel to the grinding direction were present, Figure 1. It was thus concluded that the strength of Zerodur® as prepared was not Weibull distributed. The flaws represent a sparse flaw population relative to typical grinding damage, but an extensive occurrence (high frequency) of handling damage. We examine the type of distribution present and explain the appearance of a 3-parameter distribution.

Glass, ceramic, strength, Weibull, distribution, m↗

On the roles of welding residual stresses in determination of fracture toughness in austenitic stainless steel SUS 304 pipeline girth welds

Welding residual stresses especially the high tensile stresses are proved to have negative impacts on the fatigue and fracture behaviors of welded structures. In this study, a virtual fabrication of test specimens from welding process to specimen preparation was carried out by numerical simulation. An austenitic stainless steel multi-pass pipe welding was simulated by transient thermal–mechanical finite element analysis, the residual stresses were then mapped into the test specimen to evaluate fracture toughness. The findings in this study confirmed that, residual stress can be high in a sub-sized compact tensile specimen, which may accelerate or hinder the crack propagation during actual fatigue and fracture tests as reported in recent years. The influence of the cutting location and orientation of the specimen on fracture performance was investigated systematically to provide a fundamental understanding of welding residual stress and necessary insights into the specimen preparation procedure. Considering the limitation of measuring techniques and the complexity of the stress distribution, the developed numerical model can be a very useful tool to elucidate the stress evolution and quantify the effect of remaining welding stress on fracture toughness.

Fracture behavior↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

Corrosion Testing Of Additively Manufactured Stainless Steel 316H In Molten Salt Environments

The development of a new ASTM standard for evaluating the corrosion resistance of additive manufactured (AM) stainless steel (SS) 316H in chloride molten salts is critical for the use of these materials in extreme environments such as molten salt reactors (MSRs). This report pertains to a work package of the Advaned Materials and Manufacturing Technologies (AMMT) developing a systematic methodology to link changes in AM fabrication parameters, namely surface finishing, porosity, microstructure, and chemical heterogeneity, to corrosion performance in NaCl-MgCl2 salt, a proposed secondary coolant for MSRs. During Fiscal Year 2024, Idaho National Laboratory investigators in the AMMT program, utilized SS316H bars, fabricated with laser bed powder fusion at Los Alamos National Laboratory, to establish and optimize the workflow for evaluating these process-to-performance relationships. Standard practices for specimen preparation were established using these specimens, with particular focus on descaling and sectioning methods that align with ASTM guidelines. A comprehensive experimental design for static corrosion testing was developed, with pre- and post-exposure analysis utilizing optical microscopy and scanning electron microscopy. So far standard descaling techniques were optimized, one static corrosion test was conducted on the LANL AM SS316H specimens, and pre- and post-corrosion practices were established. In addition, the work package yielded a review paper on corrosion testing gaps for AM materials in nuclear applications and submitted a proposal for a rapid-turnaround experiment to the Nuclear Science User Facilities Program to investigate the combined effects of proton irradiation and corrosion on AM SS316H. This work package establishes a foundation for evaluating processing-to-performance relationships for AM SS316H in harsh conditions, contributing to the safe and efficient design of components for next-generation nuclear reactors. The creation of a standardized methodology and the generation of relevant publications and future research pathways represent significant strides towards integrating AM materials into critical applications where corrosion resistance is paramount.

36 MATERIALS SCIENCE↗