Errors in short circuit measurements due to spectral mismatch between sunlight and solar simulators

Errors in short circuit current measurement were calculated for a variety of spectral mismatch conditions. The differences in spectral irradiance between terrestrial sunlight and three types of solar simulator were studied, as well as the differences in spectral response between three types of reference solar cells and various test cells. The simulators considered were a short arc xenon lamp AMO sunlight simulator, an ordinary quartz halogen lamp, and an ELH-type quartz halogen lamp. Three types of solar cells studied were a silicon cell, a cadmium sulfide cell and a gallium arsenide cell.

Curtis, H. B.↗

Calibration of solar cells by the reference cell method - The spectral mismatch problem

The calibration of solar cells by means of solar simulators and calibrated reference cells has always been faced with the problem of errors due to source spectral irradiance mismatch and cell spectral response mismatch. A general expression is derived in this paper to enable calculation of mismatch error. The information required to make this calculation is the relative spectra responses of the test and reference cells, and the relative spectral irradiance of the simulator (over the spectral range defined by cell response). The spectral irradiance of the solar standard is assumed given. Experimental results are presented.

Seaman, C. H.↗

The correction for spectral mismatch effects on the calibration of a solar cell when using a solar simulator

A general expression was derived to enable calculation of the calibration error. The information required includes the relative spectral response of the reference cell, the relative spectral response of the cell under test, and the relative spectral irradiance of the simulator (over the spectral range defined by cell response). The spectral irradiance of the solar AMX is assumed to be known.

Seaman, C. H.↗

Cross-calibration of Imaging Sensors using Model-based, SI-traceable Predictions of At-sensor Radiance

Many inter-consistency efforts force empirical agreement between sensors viewing a source nearly coincident in time and geometry that ensures consistency between sensors rather than obtain an SI-traceable calibration with documented error budgets. The method described here provides interconsistency via absolute radiometric calibration with defensible error budget avoiding systematic errors through prediction of at-sensor radiance for a site viewed by multiple sensors but not necessarily viewed at coincident times. The method predicts spectral radiance over a given surface site for arbitrary view and illumination angles and for any date dominated by clear-sky conditions. The foundation is a model-based, SI-traceable prediction of at-sensor radiance over selected sites based on physical understanding of the surface and atmosphere. The calibration of the ground site will include spatial, spectral, and sunview geometric effects based on satellite and ground-based data. The result is an interconsistency of hyperspectral and multispectral sensors spanning spatial resolutions from meters to kilometers all relative to the surface site rather than a single sensor. The source-centric philosophy of calibrating the site inherently accounts for footprint size mismatch, spectral band mismatch, and temporal and spatial sampling effects. The method for characterizing the test site allows its use for SI-traceable calibration of any sensor that can view the calibrated test site. Interconsistency is obtained through the traceability and error budget rather than coincident views. Such an approach to inter-consistency provides better understanding of biases between sensors as well producing more accurate results with documented SI-traceability that reduces the need for overlapping data sets.

Thome, Kurtis↗

Solar cell measurements

The measurement of the electrical performance characteristics of individual solar cells is discussed. One of the reasons is determination of the output power, measurement of the effect of various degradation mechanisms, and separation of cells by current and voltage for eventual use in series and parallel combinations. Major problem areas in making accurate performance measurements are the determination of the irradiance level during measurement, the measurement and control of cell junction temperature, and the contacting of the separate current and potential leads to the cell under test. Solar cells respond to only part of the solar spectrum, irradiance measurement made with blackbody detectors lead to spectral mismatch errors. The use of reference cells with a spectral response similar to that of the test cell reduces this error. Reference cells are calibrated at standard atmospheric conditions with all cells calibrated at the same conditions.

Curtis, H. B.↗

Optical effects of regolith processes on S asteroids as simulated by laser impulse alteration of ordinary chondrite

The spectral properties of some powdered chondrites and minerals altered by Isser impulse are studied in order to estimate possible optical effects of regolith processes (micrometeoritic bombardment). Gradual reduction of overall reflectance and spectral contrast, the increase of continuum slope, the increase of spectrally derived olivine/pyroxene ratio and Fs content of orthopyroxene with increasing alteration degree show that regolith processes could affect optical properties of surface material more heavily than has been previously appreciated. Ordinary chondrites (OC's) are known to account for 80 percent of observed meteorite falls, but so far no main belt parent bodies have been identified for these meteorites. S-asteroids resemble OC's spectrally, but are characterized by a steeper red continuum unlike that of OC's and their spectrally derived mineralogies are far outside OC range. Attempts were made to explain the spectral mismatch between OC's and S asteroids by some process, which alters optical properties of uppermost regolith. However, the spectral studies of shocked (black) OC's, gas-rich OC's, melted OC's and synthetic metal-rich regoliths derived from OC's demonstrate that such altered OC materials darken, but do not redden.

Moroz, L. V.↗

Laboratory Simulation of Space Weathering: ESR Measurements of Nanophase Metallic Iron in Laser-irradiated Olivine and Pyroxene Samples

S-type asteroids are believed to be parent bodies of ordinary chondrites. Although both S-type asteroids and ordinary chondrites contain the same mineral assemblage, mainly olivine and pyroxene, the reflectance spectra of the asteroids exhibit more overall depletion (darkening) and reddening, and more weakening of absorption bands relative to the meteorites. This spectral mismatch is explained by space weathering process, where high-velocity dust particle impacts should change the optical properties of the uppermost regolith surface of asteroids. In order to simulate the space weathering, we irradiated nanosecond pulse laser beam onto pellet samples of olivine (8.97wt% FeO) and pyroxene (enstatite: 9.88wt% FeO, hypersthene: 16.70wt%). We got spectral changes in our samples similar to that by space weathering on asteroids and confirmed nanophase alpha-metallic iron particles, which were theoretically predicted, not only on olivine but also on pyroxene samples by Transmission Electron Microscopy (TEM). Nanophase metallic iron particles were widely scattered throughout the amorphous rims developed along the olivine grains, whereas they were embedded in aggregates of amorphous in enstatite samples. Recently, we also measured laser-irradiated samples by ESR (Electron Spin Resonance). Strong ESR signals, characteristic to nanophase iron particles, are observed on irradiated olivine samples. In this paper, we report the quantities of nanophase metallic iron particles in pyroxene samples by ESR observations in addition to olivine samples.

Kurahashi, E.↗

Air mass 1.5 global and direct solar simulation and secondary reference cell calibration using a filtered large area pulsed solar simulator

Spectral mismatch between a solar simulator and a desired spectrum can result in nearly 20 percent measurement error in the output of photovoltaic devices. This occurs when a crystalline silicon cell monitors the intensity of an unfiltered large area pulsed solar simulator (LAPSS) simulating the ASTM air mass 1.5 direct spectrum and the test device is amorphous silicon. The LAPSS spectral irradiance is modified with readily available glass UV filters to closely match either the ASTM air mass 1.5 direct or global spectrum. Measurement error is reduced to about 1 percent when using either filter if the reference cell and test device are the same general type.

Mueller, Robert L.↗

Interstellar extinction variations in the Large Magellanic Cloud

The properties of ultraviolet extinction in the LMC are reexamined using some of the existing LMC data from the International Ultraviolet Explorer (IUE) satellite and a large number of new observations obtained during the IUE Sixth Episode. The main goal is to determine if the LMC extinction properties are regionally modulated and, if so, to examine the type and range of the variations. Among the new IUE observations presented is a large grid of unreddened LMC flux standards, which will eliminate spectral mismatch effects as complications in the extinction analysis. Eight new reddened stars were observed. The properties of the program stars are summarized; the method for producing the extinction curves (including the criteria for pairing reddened and unreddened stars) is discussed; and the curves themselves are presented and discussed.

Fitzpatrick, E. L.↗

Fiber Optical Solar Simulator

A new solar simulator is described whose output closely matches a desired solar spectrum for testing photovoltaic cells. The accurate simulation of the spectrum is attained by combining three light beams, each tailored to have suitable spectral content. The three light beams, derived from two sources, are filtered and 'mixed' by means of a trifurcated, randomized fiber cable so that when superimposed they add up to the desired solar spectrum. The fiber optic solar simulator (FOSS) simplifies solar cell testing by greatly reducing measurement time, obviating need for spectral mismatch corrections, and improving the accuracy of measurement. Other applications of FOSS are also described.

Sopori, Bhushan L.↗

Transmittance Measurement of a Heliostat Facility used in the Preflight Radiometric Calibration of Earth-Observing Sensors

Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration.

Czapla-Myers, J.↗

Cross-Calibration of the Oceansat-2 Ocean Colour Monitor (OCM) with Terra and Aqua MODIS

The Ocean Colour Monitor (OCM) sensor on-board the Oceansat-2 spacecraft has been operational since its launch in September, 2009. The Oceansat 2 OCM primary design goal is to provide continuity to Oceansat-1 OCM to obtain information regarding various ocean-colour variables. OCM acquires Earth scene measurements in eight multi-spectral bands in the range from 402 to 885 nm. The MODIS sensor on the Terra and Aqua spacecraft has been successfully operating for over a decade collecting measurements of the earth's land, ocean surface and atmosphere. The MODIS spectral bands, designed for land and ocean applications, cover the spectral range from 412 to 869 nm. This study focuses on comparing the radiometric calibration stability of OCM using near-simultaneous TOA measurements with Terra and Aqua MODIS acquired over the Libya 4 target. Same-day scene-pairs from all three sensors (OCM, Terra and Aqua MODIS) between August, 2014 and September, 2015 were chosen for this analysis. On a given day, the OCM overpass is approximately an hour after the Terra overpass and an hour before the Aqua overpass. Due to the orbital differences between Terra and Aqua, MODIS images the Libya 4 site at different scan-angles on a given day. Some of the high-gain ocean bands for MODIS tend to saturate while viewing the bright Libya 4 target, but bands 8-10 (412 nm - 486 nm) provide an unsaturated response and are used for comparison with the spectrally similar OCM bands. All the standard corrections such as bidirectional reflectance factor (BRDF), relative spectral response mismatch, and impact for atmospheric water-vapor are applied to obtain the reflectance differences between OCM and the two MODIS instruments. Furthermore, OCM is used as a transfer radiometer to obtain the calibration differences between Terra and Aqua MODIS reflective solar bands.

Angal, Amit↗

Comparison of the MODIS and VIIRS Thermal Emissive Band Radiometric Calibration

Moderate Resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) are major instruments for Earth science observations.Nearly 40 MODIS scientific products and a wide range of VIIRS environmental data records are produced using their global observations. The consistency of the MODIS and VIIRS calibrated data is important for the study of Earth science. This article assesses the calibration consistency of the Aqua MODIS and VIIRS thermal emissive band (TEB) data. To remove the impact of the mismatched relative spectral response (RSR) on the comparisons, the simultaneous nadir observation data from the cross-track infrared sounder (CrIS) and the infrared atmospheric sounding interferometer (IASI) are used as references in two different methods to independently verify the consistency. The comparisons of the MODIS and VIIRS TEB calibrated data show that the brightness temperature (BT) differences for comparable bands between MODIS and VIIRS are in general within 0.2 K for BT larger than 230 K. The differences of all comparable MODIS and VIIRS TEBs are consistent over time. MODIS measurements agree better with N20 VIIRS than with Suomi National Polar-orbiting Partnership (S-NPP) VIIRS. The S-NPP VIIRS measurements are higher than N20 VIIRS, within 0.1 Kfor long-wave infrared (LWIR) bands and 0.3 K for band M13.

Calibration↗

Developing a Spectral Correlation based Method for mitigating Angular Mismatch Effects in Intercalibration Using a Benchmark Hyperspectral Sensor

The CLARREO Pathfinder (CPF) mission will implement a state-of-the-art intercalibration method for transferring CPF’s in-orbit Système Internationale (SI)-traceable reference to the shortwave channel of the Clouds and the Earth’s Radiance Energy System (CERES) and the reflective solar bands of the Visible Infrared Imaging Radiometer Suite (VIIRS) aboard the NOAA-20 satellite platform with a targeted intercalibration methodology uncertainty of 0.3% (k=1). In order to achieve such a high intercalibration accuracy, the CPF intercalibration measurements to be scheduled need to closely match those from CERES and VIIRS in time, space, angles, and wavelength. Despite’s CPF’s two-axis pointing capability to match its boresight line of sight to that of a target sensor, there will be finite residual differences in angular samplings of the two instruments. The potential angular mismatch between CPF and the target sensors can introduce systematic errors in the intercalibration results, and therefore needs to be corrected using a rigorously designed algorithm. The CPF intercalibration team has been developing a correction method for mitigating the impact of these angular anisotropic effects in the CPF-VIIRS and CPF-CERES intercalibration. The method explores the spectral correlation relationship between the reflected solar radiances from the same surface target that would be measured by CPF at two adjacent angles. Our studies have shown that the spectral information based on CPF measurements can be used to accurately predict the spectral radiance or reflectance difference due to a given mismatch in the viewing and solar geometry. The hyper-spectral information can also be used to provide scene stratification without using any auxiliary data, which is critical to reduce the angular correction uncertainty. The angular correction relationship can be well established using simulated CPF-like top-of-atmosphere spectral radiances observed at all sorts of viewing geometry and solar angles and for different scenes. Intensive radiative transfer simulations have been completed using a state-of-art radiative transfer model developed by the CPF team members. The implementation of the algorithm on high-fidelity event simulation data and the characterization for the angular adjustment uncertainty will be presented.

Wan Wu↗

Assessing the Calibration Differences in the Reflective Solar Bands of Terra MODIS and Landsat-7 Enhanced Thematic Mapper Plus

Long-term data records obtained from Earth observing sensors depend not only onthe calibration accuracy of individual sensors but also on the consistency across instruments andplatforms. Hence, sensor calibration intercomparison plays a vital role for a better understandingof various science products. The Moderate Resolution Imaging Spectroradiometer (MODIS)and enhanced thematic mapper plus (ETM+) on the Terra and Landsat 7 platforms have operatedsuccessfully since their launch, collecting measurements in the reflective solar and infrared partsof the spectrum. Terra MODIS has employed a reflectance-based calibration since beginning itsmission. In the case of ETM+, a radiance-based calibration was employed until recent years,when a reflectance-based calibration was introduced. Being in the AM constellation with lessthan 30 min difference in overpass times, near-simultaneous Earth scene measurements can beeffectively used to assess the calibration differences between the spectrally matching bands ofthese two instruments. The pseudoinvariant calibration sites (PICS) in the North African desertare widely used for on-orbit calibration and validation of satellite sensors. Four PICS from thisregion have been employed to assess the multitemporal reflectance differences. Correction forbidirectional reflectance, spectral response function mismatch, and impacts of atmosphericwater-vapor have been incorporated to provide an assessment of the long-term stability ofeach spectral band and reflectance differences amongst them. Results indicate that the spectralbands of both instruments show a long-term stability to within 2% from 2000 to 2017. Thetop-of-atmosphere reflectances between the two instruments postcorrection agree to within 4%.Also included in this paper is a detailed discussion of various parameters contributing to theuncertainties of this cross-calibration. The techniques presented in this paper can be furtherextended to perform similar intercomparison between Landsat 8 Operational Land Imager, AquaMODIS, and Suomi-NPP VIIRS.

Angal, Amit↗

DNA CTG triplet repeats involved in dynamic mutations of neurologically related gene sequences form stable duplexes

DNA triplet repeats, 5'-d(CTG)n and 5'-d(CAG)n, are present in genes which have been implicated in several neurodegenerative disorders. To investigate possible stable structures formed by these repeating sequences, we have examined d(CTG)n, d(CAG)n and d(CTG).d(CAG)n (n = 2 and 3) using NMR and UV optical spectroscopy. These studies reveal that single stranded (CTG)n (n > 2) forms stable, antiparallel helical duplexes, while the single stranded (CAG)n requires at least three repeating units to form a duplex. NMR and UV melting experiments show that the Tm increases in the order of [(CAG)3]2 < [(CTG)3]2 << (CAG)3.(CTG)3. The (CTG)3 duplex is stable and exhibits similar NMR spectra in solutions containing 0.1-4 M NaCl and at a pH range from 4.6 to 8.8. The (CTG)3 duplex, which contains multiple-T.T mismatches, displays many NMR spectral characteristics similar to those of B-form DNA. However, unique NOE and 1H-31P coupling patterns associated with the repetitive T.T mismatches in the CTG repeats are discerned. These results, in conjunction with recent in vitro studies suggest that longer CTG repeats may form hairpin structures, which can potentially cause interruption in replication, leading to dynamic expansion or deletion of triplet repeats.

NASA Discipline Exobiology↗

GEO-LEO Reflective Band Inter-Comparison with BRDF and Atmospheric Scattering Corrections

The inter-comparison of the reflective solar bands (RSB) between the instruments onboard a geostationary orbit satellite and a low Earth orbit satellite is very helpful in assessing their calibration consistency. Himawari-8 was launched 7 October 2014 and GOES-R was launched on 19 November 2016. Unlike previous GOES instruments, the Advanced Himawari Imager (AHI) on Himawari-8 and the Advanced Baseline Imager (ABI) on GOES-R have onboard calibrators for the RSB. Independent assessment of calibration is nonetheless important to enhance their product quality. MODIS (Moderate Resolution Imaging Spectroradiometer) and VIIRS (Visible Infrared Imaging Radiometer Suite) can provide good references for sensor calibration. In this work, the inter-comparison between AHI and VIIRS is performed over a pseudo-invariant target. The use of stable and uniform calibration sites provides comparison with accurate adjustment for band spectral difference, reduction of impact from pixel mismatching, and consistency of BRDF (Bidirectional Reflectance Distribution Function) and atmospheric correction. The site used is the Strzelecki Desert in Australia. Due to the difference in solar and view angles, two corrections must be applied in order to compare the measurements. The first is the atmospheric scattering correction applied to the top of atmosphere reflectance measurements. The second correction is applied to correct the BRDF effect. The atmospheric correction is performed using a vector version of the Second Simulation of a Satellite Signal in the Solar Spectrum (6SV) model and the BRDF correction is performed using a semi-empirical model. Our results show that AHI band 1 (0.47 microns) has a good agreement with VIIRS band M3 within 0.15 percent. AHI band 5 (1.61 microns) shows the largest difference (5.09 percent) with VIIRS band M10, while AHI band 5 shows the least difference (1.87 percent) in comparison with VIIRS band I3. The methods developed in this work can also be directly applied to assess GOES-16/ABI (Geostationary Operational Environment Satellite16 / Advanced Baseline Imager) calibration consistency, a topic we will address in the future.

The inter-comparison of the reflective solar bands↗