Spectrograph stabilization using a single-delay interferometer on the Hale Telescope

We describe a technique for spectrograph stabilization useful when conventional mitigation techniques of vacuum tanks, thermal insulation, and laser frequency comb may be impractical, expensive, heavy, or bulky. This includes spectrographs on airborne platforms or mounted on telescopes where they suffer a changing gravity vector or other drifts. Placing a fixed-delay interferometer in series with a spectrograph forms an externally dispersed interferometer (EDI). This produces a uniform sinusoidal comb multiplying input spectrum, creating (through heterodyning) beats (moiré patterns). In Fourier space for low frequencies up to the comb frequency, the moiré generated signal counter-rotates to ordinary spectra under an unknown disperser wavenumber drift Δx. This generates a large negative feedback signal useful in a conceptual control loop, to converge rapidly to a stable spectrum and yield Δx. A modified EDI data analysis algorithm (“crossfading”) combines frequency-weighted moiré with conventional spectrum to cancel net output spectrum reaction to Δx. Needing only a single-delay, this is a practical improvement over prior crossfading analyses requiring multiple delays. We test crossfading on ThAr data near 4850 cm−1 taken on Hale telescope in an earlier project. In a single pass, we reduce drift 20 times. Using seven iterations, we reduce 0.5 cm−1 (31 km/s Doppler equivalent) drift to 4×10−7 cm−1 (2.5 cm/s). The interferometer delay can wander, because linearity of phase versus wavenumber interpolates science features between bracketing calibrating spectral references. Second, mathematically reversing the heterodyning effect doubles effective spectral resolution without changing disperser slit.

Erskine, David J [Lawrence Livermore National Labo↗

Method for boosting dispersive spectrograph stability 1000× using interferometry with crossfaded pairs of delays

We demonstrate a key step along a technical route to achieving cm/s scale accuracy for astronomical spectrographs over long (multi-year) time scales, which is critical for the Doppler characterization of Earth sized exoplanets, and measurement of small cosmic redshift drift over many years. This same technique also enables searching exoplanet atmospheres for biosignificant molecules in direct planet imaging using, otherwise, insufficiently low resolution and drift prone dispersive (grating or prism) spectrographs. Using a method called crossfading for externally dispersed interferometers (EDIs) to get highly robust spectra, we recently demonstrated a factor of 1000 x reduction in the net shift of an EDI measured ThAr line to a deliberate simulated wavelength translation of the detector. This 1000 x gain in disperser stability can be combined with conventional stability gains afforded by fiber scramblers, vacuum tanks, and thermal control, to provide an additional 1 to 3 orders of magnitude reduction in the net point spread function shift drift. Crossfading combines high- and low-delay fringing signals that react oppositely in phase to cancel their net reaction to a detector wavelength drift. This can be implemented by an interferometer addition to a facility spectrograph.

79 ASTRONOMY AND ASTROPHYSICS↗

The Stability of Fiber Spectrographs in the Faint-source Regime

The use of optical fibers in astronomical instrumentation offers high-multiplex and light-gathering flexibility. However, with most previous fiber spectrographs optimized for large fields of view on modest-aperture telescopes, the performance of fibers in the context of faint targets on large telescopes remains largely untested. In this paper, we evaluate aspects of fiber stability, especially as they apply in the context of precision sky subtraction of faint sources at modest spectral resolution ($R$ ~ 3000). After introducing a framework for describing potential systematic errors, we use publicly available data from existing instruments, including instrumentation used by the fourth-generation Sloan Digital Sky Survey’s MaNGA project (MaNGA: Mapping Nearby Galaxies at Apache Point Observatory) and the Very Large Telescope’s FLAMES: Fiber Large Array Multi Element Spectrograph. We isolate sources of fiber systematics and estimate the observed amplitude of persistent residuals as well as stochastic noise contributions resulting from changing fiber stresses. Comparing these levels against their impact on various sky subtraction schemes demonstrates that 0.1% precision sky subtraction with fiber instruments is possible. As a demonstration, we show that the MaNGA instrument can deliver 0.2% residuals on bright near-IR sky lines with nonlocal sky subtraction, if pseudo-slit limitations are addressed by allocating 50% of its fibers to sky. We further highlight recently published deep exposures that achieved a 1$σ$ background level of 27.6 AB per square arc second, equivalent to a precision of 0.2% of the sky background continuum.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of mass flow in the transition region and inner corona

A solar rocket experiment launched on June 5, 1979 is described which provides high spectral resolution line profiles across the solar disk. The instrument consists of a small telescope with moderate spatial resolution and a spectrograph with stability and high spectroscopic resolution (about 0.028 A at 600 A). The detector system uses a microchannel plate array to provide 1,024 simultaneous measurements spanning approximately 30 A of the solar spectrum. The spectrograph uses a 3600 l/mm grating, and the spectral range 609-634 A is recorded in second order overlapping 1218-1268 A in first order. The position of the emission lines is determined by a center-of-mass routine and velocity shifts are evident. The qualitative results are in general agreement with the results of Cushman and Rense (1976).

Rottman, G. J.↗

The Magneto-optical Filter, Working Principles and Recent Progress

The Magneto-Optical Filter is described which allows simultaneous magnetic and velocity measurements (in both imaging and non-imaging modes) without the need for a spectrograph. In this way the stability and alignment problems of the spectrograph are completely overcome. Its major advantages are: wavelength absolute reference and stability, high signal to noise ratio and independence of the transmission profile from the incidence angle of the solar beam. It is an imaging instrument allowing high wave number analysis in the solar oscillation spectrum and a continuous monitoring of the image position through the chromospheric facular structures. The apparatus in use at Mt. Wilson is assembled in a modular form. The most important part of it is a glass cell containing the sodium vapor. The filter is easy to use but the cell is not easy to construct in an optimal way. The technology is in progress both to use Na and K together and to prevent the windows from becoming coated during a long-term operation.

Cacciani, A.↗

Image Registration for Stability Testing of MEMS

Image registration, or alignment of two or more images covering the same scenes or objects, is of great interest in many disciplines such as remote sensing, medical imaging. astronomy, and computer vision. In this paper, we introduce a new application of image registration algorithms. We demonstrate how through a wavelet based image registration algorithm, engineers can evaluate stability of Micro-Electro-Mechanical Systems (MEMS). In particular, we applied image registration algorithms to assess alignment stability of the MicroShutters Subsystem (MSS) of the Near Infrared Spectrograph (NIRSpec) instrument of the James Webb Space Telescope (JWST). This work introduces a new methodology for evaluating stability of MEMS devices to engineers as well as a new application of image registration algorithms to computer scientists.

Memarsadeghi, Nargess↗

Control apparatus for spectral energy source

Automatic light-controlling system for dc arc emission spectrographs controls the vaporization rate of the sample and stabilizes the dc arc. The output energy is regulated such that advantage can be taken of the highly sensitive dc arc source without sacrificing the desired precision.

Gordon, W. A.↗

Absolute calibration of a hydrogen discharge lamp in the vacuum ultraviolet

A low-pressure hydrogen discharge lamp was calibrated for radiant intensity in the vacuum ultraviolet spectral region on an absolute basis and was employed as a laboratory standard source in spectrograph calibrations. This calibration was accomplished through the use of a standard photodiode detector obtained from the National Bureau of Standards together with onsite measurements of spectral properties of optical components used. The stability of the light source for use in the calibration of vacuum ultraviolet spectrographs and optical systems was investigated and found to be amenable to laboratory applications. The lamp was studied for a range of operating parameters; the results indicate that with appropriate peripheral instrumentation, the light source can be used as a secondary laboratory standard source when operated under preset controlled conditions. Absolute intensity measurements were recorded for the wavelengths 127.7, 158.0, 177.5, and 195.0 nm for a time period of over 1 month, and the measurements were found to be repeatable to within 11 percent.

Nealy, J. E.↗

Report of the facility definition team spacelab UV-Optical Telescope Facility

Scientific requirements for the Spacelab Ultraviolet-Optical Telescope (SUOT) facility are presented. Specific programs involving high angular resolution imagery over wide fields, far ultraviolet spectroscopy, precisely calibrated spectrophotometry and spectropolarimetry over a wide wavelength range, and planetary studies, including high resolution synoptic imagery, are recommended. Specifications for the mounting configuration, instruments for the mounting configuration, instrument mounting system, optical parameters, and the pointing and stabilization system are presented. Concepts for the focal plane instruments are defined. The functional requirements of the direct imaging camera, far ultraviolet spectrograph, and the precisely calibrated spectrophotometer are detailed, and the planetary camera concept is outlined. Operational concepts described in detail are: the makeup and functions of shuttle payload crew, extravehicular activity requirements, telescope control and data management, payload operations control room, orbital constraints, and orbital interfaces (stabilization, maneuvering requirements and attitude control, contamination, utilities, and payload weight considerations).

Source record↗

Radial Velocity Detection of Extra-Solar Planetary Systems

The McDonald Observatory Planetary Search (MOPS) was designed to search for Jovian-mass planets in orbit around solar-type stars by making high-precision measurements of the Radial Velocity (RV) of a star, to attempt to detect the reflex orbital motion of the star around the star-planet barycenter. In our solar system, the velocity of the Sun around the Sun-Jupiter barycenter averages 12.3 m/ s. The MOPS survey started operation in September 1987, and searches 36 bright, nearby, solar-type dwarfs to 10 m/s precision. The survey was started using telluric O2 absorption lines as the velocity reference metric. Observations use the McDonald Observatory 2.7-m Harlan Smith Telescope coude spectrograph with the six-foot camera. This spectrograph configuration isolates a single order of the echelle grating on a Texas Instruments 800 x 800 CCD. The telluric line method gave us a routine radial velocity precision of about 15 m/s for stars down to about 5-th magnitude. However, the data obtained with this technique suffered from some source of long-term systematic errors, which was probably the intrinsic velocity variability of the terrestrial atmosphere, i.e. winds. In order to eliminate this systematic error and to improve our overall measurement precision, we installed a stabilized I2 gas absorption cell as the velocity metric for the MOPS in October 1990. In use at the telescope, the cell is placed directly in front of the spectrograph entrance slit, with starlight passing through the cell. The use of this sealed stabilized I2 cell removes potential problems with possible long-term drifts in the velocity metric. The survey now includes a sample of 36 nearby F, G, and K type stars of luminosity class V or IV-V.

Cochran, William D.↗

Validation of Ozone Profile Retrievals Derived from the OMPS LP Version 2.5 Algorithm Against Correlative Satellite Measurements

The Limb Profiler (LP) is a part of the Ozone Mapping and Profiler Suite launched on board of the Suomi NPP satellite in October 2011. The LP measures solar radiation scattered from the atmospheric limb in ultraviolet and visible spectral ranges between the surface and 80 km. These measurements of scattered solar radiances allow for the retrieval of ozone profiles from cloud tops up to 55 km. The LP started operational observations in April 2012. In this study we evaluate more than 5.5 years of ozone profile measurements from the OMPS LP processed with the new NASA GSFC version 2.5 retrieval algorithm. We provide a brief description of the key changes that had been implemented in this new algorithm, including a pointing correction, new cloud height detection, explicit aerosol correction and a reduction of the number of wavelengths used in the retrievals. The OMPS LP ozone retrievals have been compared with independent satellite profile measurements obtained from the Aura Microwave Limb Sounder (MLS), Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) and Odin Optical Spectrograph and InfraRed Imaging System (OSIRIS). We document observed biases and seasonal differences and evaluate the stability of the version 2.5 ozone record over 5.5 years. Our analysis indicates that the mean differences between LP and correlative measurements are well within required +/- 10% between 18 and 42 km. In the upper stratosphere and lower mesosphere (>43 km) LP tends to have a negative bias. We find larger biases in the lower stratosphere and upper troposphere, but LP ozone retrievals have significantly improved in version 2.5 compared to version 2 due to the implemented aerosol correction. In the northern high latitudes we observe larger biases between 20 and 32 km due to the remaining thermal sensitivity issue. Our analysis shows that LP ozone retrievals agree well with the correlative satellite observations in characterizing vertical, spatial and temporal ozone distribution associated with natural processes, like the seasonal cycle and quasi-biennial oscillations. We found a small positive drift approx. 0.5%/yr in the LP ozone record against MLS and OSIRIS that is more pronounced at altitudes above 35 km. This pattern in the relative drift is consistent with a possible 100m drift in the LP sensor pointing detected by one of our altitude-resolving methods.

Ozone Mapping↗

Excalibur: A Nonparametric, Hierarchical Wavelength Calibration Method for a Precision Spectrograph

Excalibur is a nonparametric, hierarchical framework for precision wavelength calibration of spectrographs. It is designed with the needs of extreme-precision radial-velocity (EPRV) instruments in mind, which require calibration or stabilization to better than 10{sup −4} pixels. Instruments vary along only a few dominant degrees of freedom, especially EPRV instruments that feature highly stabilized optical systems and detectors. Excalibur takes advantage of this property by using all calibration data to construct a low-dimensional representation of all accessible calibration states for an instrument. Excalibur also takes advantage of laser-frequency combs or etalons, which generate a dense set of stable calibration points. This density permits the use of a nonparametric wavelength solution that can adapt to any instrument or detector oddities better than parametric models, such as a polynomial. We demonstrate the success of this method with data from the Extreme Precision Spectrograph (EXPRES), which uses a laser-frequency comb. When wavelengths are assigned to laser comb lines using excalibur, the rms of the residuals is about one-fifth that of wavelengths assigned using polynomial fits to individual exposures. Radial-velocity measurements of HD 34411 show a reduction in rms scatter over a 10 month time baseline from 1.17 to 1.05 m s{sup −1}.

47 OTHER INSTRUMENTATION↗

Optimization of Lyot Coronagrah focal plane masks for improved low-order wavefront sensing

The WFIRST Coronagraph uses a Low-Order Wavefront Sensing and Control (LOWFS/C) subsystem to stabilize the stellar wavefront. This is true for the Hybrid Lyot Coronagraph (HLC), the Shaped Pupil Coronagraph (SPC) spectrograph, and the SPC wide field of view modes. For the SPC spectrograph, we have found via modeling and simulations that a focal plane mask (FPM) with an elliptical phase dimple can reduce the LOWFS errors significantly compared to the conventional, circular phase dimple. For HLC designs, we concurrently optimized the FPM parameters and deformable mirror shapes using our open-source software toolbox, the Fast Linearized Coronagraph Optimizer (FALCO). This process resulted in new FPMs with non-uniform central-area phase modulation. We have found in numerical simulations that such FPMs still provide sufficient LOWFS performance. In this paper, we will present the LOWFS performance for several new HLC and SPC FPM designs.

Riggs, A.J. Eldorado↗

Application of the intensified CCD to airglow and auroral measurements

New detector technology exemplified by advanced CCD and intensified CCD (ICCD) systems have important advantages for both spectrographic and imaging research. However, to realize the full potential of this new technology, the detector and the optical system as a whole must be considered. It is frequently not enough to simply substitute an ICCD for an earlier detector; rather, to achieve optimum results, the optics must be adapted to the specific detector. Properly designed airglow spectrographs based on the ICCD detector offer the advantages of high throughput over a broad spectral range, precise wavelength stability, low noise, and compactness. Imagers having the wide field and the high sensitivity needed for airglow research are practical as well.

Broadfoot, A. L.↗

Sodium Velocity Maps on Mercury

The objective of the current work was to measure two-dimensional maps of sodium velocities on the Mercury surface and examine the maps for evidence of sources or sinks of sodium on the surface. The McMath-Pierce Solar Telescope and the Stellar Spectrograph were used to measure Mercury spectra that were sampled at 7 milliAngstrom intervals. Observations were made each day during the period October 5-9, 2010. The dawn terminator was in view during that time. The velocity shift of the centroid of the Mercury emission line was measured relative to the solar sodium Fraunhofer line corrected for radial velocity of the Earth. The difference between the observed and calculated velocity shift was taken to be the velocity vector of the sodium relative to Earth. For each position of the spectrograph slit, a line of velocities across the planet was measured. Then, the spectrograph slit was stepped over the surface of Mercury at 1 arc second intervals. The position of Mercury was stabilized by an adaptive optics system. The collection of lines were assembled into an images of surface reflection, sodium emission intensities, and Earthward velocities over the surface of Mercury. The velocity map shows patches of higher velocity in the southern hemisphere, suggesting the existence of sodium sources there. The peak earthward velocity occurs in the equatorial region, and extends to the terminator. Since this was a dawn terminator, this might be an indication of dawn evaporation of sodium. Leblanc et al. (2008) have published a velocity map that is similar.

Potter, A. E.↗

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗

Broadband Stability of the Habitable Zone Planet Finder Fabry–Pérot Etalon Calibration System: Evidence for Chromatic Variation

The comblike spectrum of a white light–illuminated Fabry–Pérot etalon can serve as a cost-effective and stable reference for precise Doppler measurements. Understanding the stability of these devices across their broad (hundreds of nanometers) spectral bandwidths is essential to realizing their full potential as Doppler calibrators. However, published descriptions remain limited to small bandwidths or short time spans. We present an ∼6 month broadband stability monitoring campaign of the Fabry–Pérot etalon system deployed with the near-infrared Habitable Zone Planet Finder (HPF) spectrograph. We monitor the wavelengths of each of ∼3500 resonant modes measured in HPF spectra of this Fabry–Pérot etalon (free spectral range = 30 GHz, bandwidth = 820–1280 nm), leveraging the accuracy and precision of an electro-optic frequency comb reference. These results reveal chromatic structure in the Fabry–Pérot mode locations and their evolution with time. We measure an average drift on the order of 2 cm s{sup –1} day{sup −1}, with local departures up to ±5 cm s{sup –1} day{sup −1}. We discuss these behaviors in the context of the Fabry–Pérot etalon mirror dispersion and other optical properties of the system and the implications for the use of similar systems for precise Doppler measurements. Our results show that this system supports the wavelength calibration of HPF at the ≲10 cm s{sup −1} level over a night and the ≲30 cm s{sup −1} level over ∼10 days. Our results also highlight the need for long-term and spectrally resolved study of similar systems that will be deployed to support Doppler measurement precision approaching ∼10 cm s{sup −1}.

42 ENGINEERING↗