Search NASASearch

SEARCH · Search NASA

Results for “spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Interpretation of Various Radiation Backgrounds Observed in the Gamma-Ray Spectrometer Experiments Carried on the Apollo Missions and Implications for Diffuse Gamma-Ray Measurements

Since the report of a preliminary analysis of cosmic gamma-ray measurements made during the Apollo 15 mission, an improved calculation of the spallation activation contribution has been made including the effects of short-lived spallation fragments, which can extend the correction to 15 MeV. In addition, a difference between Apollo 15 and 16 data enables an electron bremsstrahlung contribution to be calculated. A high level of activation observed in a crystal returned on Apollo 17 indicates a background contribution from secondary neutrons. These calculations and observations enable an improved extraction of spurious components and suggest important improvements for future detectors.

C S Dyer

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

The Alpha-Proton-X-Ray Spectrometer Deployment Mechanism: an Anthropomorphic Approach to Sensor Placement on Martian Rocks and Soil

On July 4,1997, the Mars Pathfinder spacecraft lands on Mars and starts conducting technological and scientific experiments. One experiment, the Alpha-Proton-X-ray Spectrometer, uses a sensor head placed against rocks and soil to determine their composition. To guarantee proper placement, a deployment mechanism mounted on the Mars Rover aligns the sensor head to within 20 deg of the rock and soil surfaces. In carrying out its task, the mechanism mimics the action of a human hand and arm. Consisting of a flexible wrist, a parallel link arm, a brush dc motor actuator, and a revolutionary non-pyrotechnic fail-safe release device, the mechanism correctly positions the sensor head on rocks as high as 0.29 m and on targets whose surfaces are tilted as much as 45 deg from the nominal orientation of the sensor head face. The mechanism weighs less than 0.5 kg, can withstand 100 g's, and requires less than 2.8 N x m of actuation torque. The fail-safe coupler utilizes Cerrobend, a metal alloy that melts at 60 C, to fuse the actuator and the rest of the mechanism together. A film heater wrapped around the coupler melts the metal, and Negator springs drive the mechanism into its stowed position. The fail-safe actuates using 6.75 Watts for 5 minutes in the event of an actuator failure.

Richard S Blomquist

The Hyperspectral Microwave Photonic Instrument (HyMPI) and its NEDT Performance

This work presents an overview of a hyperspectral microwave-photonic spectrometer and demonstrates the system end-to-end noise equivalent delta temperature (NEDT) performance. The system aims at augmenting the remote sensing capability from space, with a focus on the Earth’s planetary boundary layer (PBL) thermal microwave (MW) spectral region (0-200 GHz). Combining a Photonic Integrated Circuit (PIC) channelizer and an application-specific integrated circuit (ASIC) spectrometer, the PIC & ASIC (PICASIC) module is capable of processing 40 GHz spectra at hyperspectral (4 MHz) resolution. The photonic technology is agnostic to the spectral region and multiple photonic modules can cover the entire 200 GHz spectrum. Measured results of the end-to-end system NEDT agree with predicted values confirming that the NEDT is primarily dominated by the noise figure of the MW front-end, with the optical link adding no significant noise. The data also demonstrate that a single module enables simultaneous super- and hyper-spectral resolution channel analysis across a 40 GHz range.

spectrometer

Evidence of an Extended Period of Aqueous Alteration on the Bennu Parent Body Revealed By I-Xe Analyses

NASA’s OSIRIS-REx mission delivered to Earth 121.6 g of regolith material from asteroid Bennu on 24th September 2023. We report multi-step laser pyrolysis xenon isotopic analysis to investigate the I-Xe system in individual particles separated from aggregate material (a mixture of small particles of undefined lithology). The high sensitivity of the RELAX mass spectrometer allows us to observe small excesses of individual isotopes and separate out different components, which may not be possible using a conventional noble gas mass spectrometer. The temperature resolution of RELAX is sufficient to seek an I-Xe isochron from step heating analysis of a sample mass <100 μg, which can contribute to our understanding of the nature and timing of aqueous alteration on Bennu’s parent body. We also aim to better estimate and understand the iodine concentration of CI chondrite-like material.

S A Crowther

Thermal Vacuum Testing of the Cryostat Heat Removal System for COSI SMEX

The Cryostat Heat Removal System (CHRS) of the Compton Spectrometer and Imager (COSI) consists of cryocooler, three transport aluminum ammonia Constant Conductance Heat Pipes (CCHP), three radiators with CCHP spreaders and Cryocooler Control Electronics (CCE) attached to a separate radiator. A Thermal Vacuum (TVAC) test was conducted at NASA Goddard Space Flight Center to characterize the integrated COSI CHRS in the flat configuration. This presentation summarizes the measured COSI CHRS performance along with lessons learned.

Pipes

Opportunities to Intercalibrate Radiometric Sensors from International Space Station

Highly accurate measurements of Earth's thermal infrared and reflected solar radiation are required for detecting and predicting long-term climate change. Consideration is given to the concept of using the International Space Station to test instruments and techniques that would eventually be used on a dedicated mission, such as the Climate Absolute Radiance and Refractivity Observatory (CLARREO). In particular, a quantitative investigation is performed to determine whether it is possible to use measurements obtained with a highly accurate (0.3%,with 95%confidence) reflected solar radiation spectrometer to calibrate similar, less accurate instruments in other low Earth orbits. Estimates of numbers of samples useful for intercalibration are made with the aid of yearlong simulations of orbital motion. Results of this study support the conclusion that the International Space Station orbit is ideally suited for the purpose of intercalibration between spaceborne sensors.

Intercalibrate

Lunar Elemental Analysis Obtained From the Apollo Gamma-Ray and X-Ray Remote Sensing Experiment

Gamma-ray and X-ray spectrometers carried in the Service Modules of the Apollo 15 and Apollo 16 spacecraft were employed for compositional mapping of the lunar surface. The measurements involved the observation of the intensity and characteristic energy distribution of gamma rays and X-rays emitted from the lunar surface. A large-scale compositional map of over 10 percent of the lunar surface was obtained from an analysis of the observed spectra. The Apollo 15 flight was at a lunar orbital inclination of 29 degrees as compared with a 9-degree inclination of the Apollo 16 flight; thus, the projected ground track of the Apollo 15 flight covered a larger projected surface area than that of the Apollo 16 flight. The objective of the X-ray experiment was to measure the K spectral lines from Mg, Al, and Si. Spectra were obtained and the data were reduced to Al/Si and Mg/Si intensity ratios and ultimately to chemical ratios. Analyses of the results have indicated (1) that the Al/Si ratios are highest in the lunar highlands and considerably lower in the maria, and (2) that the Mg/Si concentrations generally show the opposite relationship. There is a tendency for the Al/Si values to increase from the western mare areas to the eastern limb highlands. There are distinct chemical contrasts between such features: as the small mare basins and the highland rims. The objective of the gamma-ray experiment was to measure the natural and cosmic-ray-induced activity emission spectrum. At this time, the elemental abundances for Th, U, K, Fe, Ti, Si, and O have been determined over a number of major lunar regions. Regions of relatively high natural radioactivity were found in the Mare Imbrium and Oceanus Procellarum regions. High spots of natural radioactivity were also found south of Fra Mauro; somewhat southwest of Archimedes, and south of Aristarchus. An enhanced region of natural radioactivity was found around Van de Graaff on the far side of tile Moon. In regions other than Mare Imbrium and Oceanus Procellarum, an anticorrelation between natural radioactivity and lunar elevation, as determined from the Apollo laser, altimeter, has been found. From the combined results of the gamma-ray and X-ray spectrometer experiments almost complete information concerning the major element composition of over 10 percent of the lunar surface has been obtained. Distributions have also been mapped for K, Th, and Ti. Interesting correlations between lunar topography and magnetic and gravitational properties have been found.

J I Trombka

Air-Broadened Line Shapes in the 2n3 R Branch of 12ch4 Between 6014 and 6100 cm-1

Complete and accurate information on line shape parameters of 2?3 methane transitions for air broadening as a function of temperature is critical not only for the correct interpretation of the observed atmospheric spectra but also for the development of a reliable theoretical model. For this reason, we obtained a series of high-resolution, high S/N spectra of high-purity 12CH4 and 12CH4 broadened with dry air at temperatures in the 130 to 295 K range using the Bruker IFS 125HR Fourier transform spectrometer at JPL. Two absorption cells were used in the experiment, a White cell with path length of 13 m for room temperature spectra and a 21 m Herriott cella for cold sample spectra. The 15 spectra used in the analysis consisted of 3 low pressure (0.26 to 2.57 Torr) spectra with pure 12CH4 and 12 air-broadened spectra with total sample pressures of 79-805 Torr and volume mixing ratios of methane between 0.23 and 1%. A multispectrum least-squares fitting techniqueb was employed to fit all 15 spectra simultaneously. Preliminary results for select R(J) manifolds will be presented.

V Malathy Devi

The Future of Oaks in the Santa Monica Mountains: A Case Study in Using Remote Sensing Data for Species Distributions Models

The Woolsey Fire began on November 8, 2018, and lasted for almost two weeks, during which it burned almost 100,000 acres of valuable landscape and habitat, including a vast area of woodland. The persistence of key woodland species provides aesthetic, monetary, and ecological value to the landscape through carbon sequestration, air temperature moderation, and erosion mitigation, among other ecosystem services. This study investigated the impact of the Woolsey Fire on native woodland species distributions and identified areas suitable for restoration within the Santa Monica Mountains National Recreation Area. The team partnered with the Resource Conservation District of the Santa Monica Mountains; National Park Service, Santa Monica Mountains National Recreation Area; California Department of Parks and Recreation, Los Angeles County Division; County of Los Angeles Fire Department, Prevention Services Bureau, Forestry Division; County of Los Angeles Department of Regional Planning; and the University of Montana. The Earth observations used include data from Landsat 8 Operational Land Imager, NASA ER-2 Jet Airborne Visible InfraRed Imaging Spectrometer, Shuttle Radar Topography Mission, and RapidEye. The team produced maps of burn severity from the Woolsey Fire, its impact on plant species distributions, and habitat suitability projections for 2050 and 2099 to assist partners in prioritizing areas for restoration. A plant community classification was successfully created using Multiple Endmember Spectral Mixture Analysis (MESMA). Overall accuracy was assessed at 90.54% by comparing the classification to validation pixels derived from ground truth information provided by our partners.

Roger Ly

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

First N 2 Profile for Venus’ Deep Lower Atmosphere

We present the first N 2 profile for Venus’ deep lower atmosphere (<15 km) and a constrained isotopic composition for cloud N 2 [1]. This work directly addresses unresolved questions for Venus using legacy observations. Prior to this work, there were no reported measurements for N 2 abundances at <15 km and the isotopic composition remained unconstrained [2]. The N 2 parameters are critical to understanding the evolution and thermal properties of the atmosphere [3-7]. Our N 2 results were obtained by re-analysis of data acquired in 1978 by the Pioneer Venus Large Probe Neutral Mass Spectrometer (LNMS) [8]. The archived mass spectra from 64.2 to 0.2 km were treated using the analytical procedures specifically developed for the LNMS [9-11]. Judicious peak fitting permitted disambiguation of (A) N 2 + and CO + at 28 u and (B) 14 N 15 N+, 13 CO + , and C 2 H 5 + at 29 u. Quality controls included comparing the (A) LNMS CO + /CO 2 + ratios to the NIST database and literature and (B) fitted counts for CO + to the expected counts of CO + calculated from C 18 O + and 13 CO + using the LNMS 16 O/ 18 O and 12 C/ 13 C ratios (obtained from CO 2 ). Our results show that N 2 is uniformly mixed across the deep lower atmosphere between ~0.2 and 15 km (2.49 ± 0.10 v%). In contrast, N 2 is non-uniformly mixed across the sub-cloud atmosphere and clouds (~15–59 km), where N 2 abundances increase by ~ 2-fold between ~15 km (2.45 ± 0.32 v%) and ~59-51 km (5.21 ± 0.18 v%). Using the cloud data, we also obtained a constrained 15 N/ 14 N ratio (2.93×10 -3 ± 0.13×10 -3 ) and δ 15 N value (-204 ± 35‰). Thus, the LNMS results [1] suggest that (A) the atmosphere is unstable at <15 km, (B) N 2 is not well-mixed >15 km, and (C) the cloud δ 15 N falls between Earth and the solar wind [12, 13]. Comparisons of the N 2 abundances and isotopic compositions for nitrogen, carbon, and oxygen to other Venus measurements will be discussed.

deep lower atmosphere

Radio Metric Errors Due to Mismatch and Offset Between a DSN Antenna Beam and the Beam of a Troposphere Calibration Instrument

Two components of the error of a troposphere calibration measurement were quantified by theoretical calculations. The first component is a beam mismatch error, which occurs when the calibration instrument senses a conical volume different from the cylindrical volume sampled by a Deep Space Network (DSN) antenna. The second component is a beam offset error, which occurs if the calibration instrument is not mounted on the axis of the DSN antenna. These two error sources were calculated for both delay (e.g., VLBI) and delay rate (e.g., Doppler) measurements. The beam mismatch error for both delay and delay rate drops rapidly as the beamwidth of the troposphere calibration instrument (e.g., a water vapor radiometer or an infrared Fourier transform spectrometer) is reduced. At a 10-deg elevation angle, the instantaneous beam mismatch error is 1.0 mm for a 6-deg beamwidth and 0.09 mm for a 0.5-deg beam (these are the full angular widths of a circular beam with uniform gain out to a sharp cutoff). Time averaging for 60-100 sec will reduce these errors by factors of 1.2-2.2. At a 20-deg elevation angle, the lower limit for current Doppler observations, the beam-mismatch delay rate error is an Allan standard deviation over 100 sec of 1.1 x 10 -14 with a 4-deg beam and 1.3 x 10 -15 for a 0.5-deg beam. A 50-m beam offset would result in a fairly modest (compared to other expected error sources) delay error (less than or equal to 0.3 mm for 60-sec integrations at any elevation angle is greater than or equal to 6 deg). However, the same offset would cause a large error in delay rate measurements (e.g., an Allan standard deviation of 1.2 x 10 -14 over 100 sec at a 20-deg elevation angle), which would dominate over other known error sources if the beamwidth is 2 deg or smaller. An on-axis location is essential for accurate troposphere calibration of delay rate measurements. A half-power beamwidth (for a beam with a tapered gain profile) of 1.2 deg or smaller is desired for calibration of all types of radio metrics. A water-vapor radiometer calibration beam of this size with very low sidelobes would require a clear aperture antenna with a diameter of at least 1.5 m if the primary water vapor sensing channel were in the 20-22 GHz range.

R P Linfield

Prototype Demonstration of Solar-Carbothermal System to Extract Oxygen From Regolith

The Carbothermal Reduction Demonstration (CaRD) project was an effort to develop a prototype system to demonstrate the extraction of oxygen from simulated lunar regolith using concentrated solar energy and a carbothermal reaction. The prototype consisted of a deployable solar concentrator capable of tracking the sun, carbothermal reactor, fluid system, gas analysis, and a solar concentrator control system consisting of avionics and software. These subsystems were developed by multiple NASA centers and a private industry partner, Sierra Space. The various teams worked together to define requirements and interfaces to successfully assemble the complex system and demonstrate an integrated solar carbothermal process. The solar concentrator developed at Glenn Research Center (GRC) was designed to be stowed for a launch environment then deployed on the lunar surface. It utilized a crossed dragone configuration of composite mirrors to direct horizontal sunlight onto a target 90° from the incoming sunlight. The key performance parameters for the solar concentrator were efficiency and power density. The carbothermal reactor was developed by Sierra Space through a separate project called the Carbothermal Oxygen Production Reactor (COPR) where it successfully demonstrated a fully automated process in a thermal vacuum environment [1]. The fluid system needed for the carbothermal reaction was also developed by Sierra Space and successfully demonstrated in the same thermal vacuum test. The gas analysis system was developed at Kennedy Space Center (KSC) and was required to determine the amount of oxygen extracted during each test. The gas analysis system was based on the Mass Spectrometer Observing Lunar Operations (MSOLO) instrument. Avionics and software for the CaRD prototype were also developed at KSC and based on experience with MSOLO avionics and software. The control system was designed to stow, deploy, track the sun, and perform beam alignment of the concentrated light. The prototype subsystems were integrated and tested at Johnson Space Center’s (JSC) Energy Systems Test Area. A heliostat was used to direct sunlight toward the prototype in a way that is representative of the sunlight conditions at the south pole of the Moon. When concentrated sunlight was focused on simulated lunar regolith within the reactor, the gas analysis team confirmed the presence of carbon monoxide gas, which confirmed that a solar carbothermal reaction took place. The key performance parameter for the integrated prototype was grams of oxygen extracted per kilowatt hour of energy arriving at the concentrator primary mirror. The prototype design successfully demonstrated end-to-end capability and further steps to achieve a flight capable system have been defined. With lunar data, engineers would be able to design a scaled-up system capable of extracting oxygen from regolith at useful quantities for crew life support and rocket propellant. On the long term, this method of In-Situ Resource Utilization could be used to drastically reduce the cost and risk of a sustained human presence on the Moon by reducing the amount of oxygen that would have to be delivered.

Koorosh R Araghi

Prototype Demonstration of Solar Carbothermal System to Extract Oxygen from Regolith

The Carbothermal Reduction Demonstration (CaRD) project was an effort to develop a prototype system to demonstrate the extraction of oxygen from simulated lunar regolith using concentrated solar energy and a carbothermal reaction. The prototype consisted of a deployable solar concentrator capable of tracking the sun, carbothermal reactor, fluid system, gas analysis, and a solar concentrator control system consisting of avionics and software. These subsystems were developed by multiple NASA centers and a private industry partner, Sierra Space. The various teams worked together to define requirements and interfaces to successfully assemble the complex system and demonstrate an integrated solar carbothermal process. The solar concentrator developed at Glenn Research Center (GRC) was designed to be stowed for a launch environment then deployed on the lunar surface. It utilized a crossed dragone configuration of composite mirrors to direct horizontal sunlight onto a target 90° from the incoming sunlight. The key performance parameters for the solar concentrator were efficiency and power density. The carbothermal reactor was developed by Sierra Space through a separate project called the Carbothermal Oxygen Production Reactor (COPR) where it successfully demonstrated a fully automated process in a thermal vacuum environment. The fluid system needed for the carbothermal reaction was also developed by Sierra Space and successfully demonstrated in the same thermal vacuum test. The gas analysis system was developed at Kennedy Space Center (KSC) and was required to determine the amount of oxygen extracted during each test. The gas analysis system was based on the Mass Spectrometer Observing Lunar Operations (MSOLO) instrument. Avionics and software for the CaRD prototype were also developed at KSC and based on experience with MSOLO avionics and software. The control system was designed to stow, deploy, track the sun, and perform beam alignment of the concentrated light. The prototype subsystems were integrated and tested at Johnson Space Center’s (JSC) Energy Systems Test Area. A heliostat was used to direct sunlight toward the prototype in a way that is representative of the sunlight conditions at the south pole of the Moon. When concentrated sunlight was focused on simulated lunar regolith within the reactor, the gas analysis team confirmed the presence of carbon monoxide gas, which confirmed that a solar carbothermal reaction took place. The key performance parameter for the integrated prototype was grams of oxygen extracted per kilowatt hour of energy arriving at the concentrator primary mirror. The prototype design successfully demonstrated end-to-end capability and further steps to achieve a flight capable system have been defined. With lunar data, engineers would be able to design a scaled-up system capable of extracting oxygen from regolith at useful quantities for crew life support and rocket propellant. On the long term, this method of In-Situ Resource Utilization could be used to drastically reduce the cost and risk of a sustained human presence on the Moon by reducing the amount of oxygen that would have to be delivered.

Aaron Paz