Search NASASearch

SEARCH · Search NASA

Results for “spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Bulk and integrated acousto-optic spectrometers for molecular astronomy with heterodyne spectrometers

A survey of acousto-optic spectrometers for molecular astronomy is presented, noting a technique of combining the acoustic bending of a collimated coherent light beam with a Bragg cell followed by an array of sensitive photodetectors. This acousto-optic spectrometer has a large bandwidth, a large number of channels, high resolution, and is energy efficient. Receiver development has concentrated on high-frequency heterodyne systems for the study of the chemical composition of the interstellar medium. RF spectrometers employing acousto-optic diffraction cells are described. Acousto-optic techniques have been suggested for applications to electronic warfare, electronic countermeasures and electronic support systems. Plans to use integrated optics for the further miniaturization of acousto-optic spectrometers are described. Bulk acousto-optic spectrometers with 300 MHz and 1 GHz bandwidths are being developed for use in the back-end of high-frequency heterodyne receivers for astronomical research.

Chin, G.

Composition measurements of the topside ionosphere using a magnetic mass spectrometer, ion mass spectrometer on ISIS-2 spacecraft

The ion mass spectrometer (IMS) on the ISIS-II satellite is described; it measures the composition and distribution of positive ions in the earth's ionosphere in the mass range of 1 to 64 atomic mass units. Significant data were received which show a wide variation in ion composition at night near the equator and in the daytime poleward of the plasmapause. It was found that these data enable further study of the polar wind and that the experiment produced timely data during the August, 1972 magnetic storm to show the development of a unique ionosphere above the plasmapause during the period of the storm. The scientific objectives and results of the experiment, the technical description of the instrument, a bibliography with sample papers attached, and a summary of recommendations for further study are presented.

Hoffman, J. H.

Development of a versatile plate spectrometer for electron beam characterization

A new instrument for electron beam characterization has been developed, based on measuring the range of beam electrons in different thicknesses of aluminum, to determine both the current and energy of an electron beam traveling in open air. This instrument is referred to as a ‘plate spectrometer’ as the thickness of the spectrometer is adjusted by adding or removing aluminum plates. This spectrometer was assembled and then characterized at the Idaho Accelerator Center (IAC) with three different beam energies and with one beam energy at the University of Maryland Radiation Facilities. The plate spectrometer was able to match the median energies and provide a reasonable constraint to the beam distributions seen in the IAC magnetic spectrometer. Finally, in a separate experiment, the plate spectrometer was also seen to agree with a dosimetry characterization of the beam at the University of Maryland Radiation Facilities and improved upon the uncertainties of this measurement.

43 PARTICLE ACCELERATORS

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Planetary atmospheres with mass spectrometers carried on high-speed probes or satellites

Earth satellite-borne mass spectrometers are considered, taking into account the identification of atomic oxygen in the thermosphere with an 'open' source mass spectrometer flown on a sounding rocket, the conventional closed-source instrument, the mass spectrometers on the Atmosphere Explorer satellites, and mass spectrometer electron multiplier output. A description is presented of mass spectrometers and planetary entry probes. Attention is given to an attempt to obtain an atmospheric composition profile with a terrestrial entry probe, the descending trajectory in the early orbits of the Atmosphere Explorer C satellite, and the molecular nitrogen densities for the descending legs of the orbits. It is pointed out that chemical reactions on the surfaces of the mass spectrometer make the measurement of reactive atmospheric species such as atomic oxygen very difficult.

Nier, A. O.

Spectral characterization and performance of SPT-SLIM on-chip filterbank spectrometers

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) experiment is a pathfinder for demonstrating the use of on-chip spectrometers for millimeter (mm) Line Intensity Mapping (LIM). We present spectral bandpass measurements of the SPT-SLIM spectrometer channels made on site using a Fourier Transform Spectrometer during the first deployment of SPT-SLIM in the 2024-2025 Austral summer season. We note the effect of FTS systematics on measurements of on-chip filterbank spectrometer resolutions and demonstrate a technique for measuring the narrow band passes of the SPT-SLIM filterbanks that improves beyond the intrinsic resolution of a Fourier Transform Spectrometer.

Benson, C. S. [Cardiff U.]

Lunar orbital mass spectrometer experiment

The design, development, manufacture, test and calibration of five lunar orbital mass spectrometers with the four associated ground support equipment test sets are discussed. A mass spectrometer was installed in the Apollo 15 and one in the Apollo 16 Scientific Instrument Module within the Service Module. The Apollo 15 mass spectrometer was operated with collection of 38 hours of mass spectra data during lunar orbit and 50 hours of data were collected during transearth coast. The Apollo 16 mass spectrometer was operated with collection of 76 hours of mass spectra data during lunar orbit. However, the Apollo 16 mass spectrometer was ejected into lunar orbit upon malfunction of spacecraft boom system just prior to transearth insection and no transearth coast data was possible.

Lord, W. P.

Data processing improvements for the Skylab S-191 EREP spectrometer

The characteristics of the S-191 spectrometer (filter wheel infrared spectrometer) are discussed. Inherent deficiencies in previous spectrometers are described and the techniques for correcting the deficiencies are explained. The radiance errors caused by error in wavelength are identified and the effects on the accuracy of the spectrometer are described. It is stated that the most important source of error in the S-191 spectrometer is off-band radiation in which the detected radiation is far from the wavelength which is expected to be detected by the sensor at that particular time. A numerical analysis of the effects of off-band radiation is developed.

Campbell, C. E.

Study and evaluation of impulse mass spectrometers for ion analysis in the D and E regions of the ionosphere

Theoretical and numerical analyses were made of planar, cylindrical and spherical electrode time-of-flight mass spectrometers in order to optimize their operating conditions. A numerical analysis of potential barrier gating in time-of-flight spectrometers was also made. The results were used in the design of several small mass spectrometers. These were constructed and tested in a laboratory space simulator. Detailed experimental studies of a miniature cylindrical electrode time of flight mass spectrometer and of a miniature hemispherical electrode time of flight mass spectrometer were made. The extremely high sensitivity of these instruments and their ability to operate at D region pressures with an open source make them ideal instruments for D region ion composition measurements.

Kendall, B. R.

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

Somov, Alexander [Jefferson Lab]

Shortwave Spectrometer (SWS) zenith radiance swsrad.b1 v3 and higher

Hyperspectral zenith radiances from the SWS instrument reported at 1 Hz. This data stream contains calibrated, dark-subtracted, radiances from two grating array spectrometers: a Si-detector based spectrometer denoted by SW and an InGaAs based detector denoted by LW. Spectra from both spectrometers are calibrated based on the spectral responsivity determined by reference against NIST-traceable light sources are reported independently as separate arrays having the same time record but wavelength dimension specified for each detector. Because the LW spectrometer is more susceptible to temperature-induced changes, a scale factor adjustment is applied the the LW spectra to yield agreement with the SW spectra over the wavelength range where they overlap. The final radiances incorporate QC to flag saturated values, periods where house-keeping fields fall outside acceptable bounds, and to flag pixels for which the spectral responsivity is not acceptable.

54 ENVIRONMENTAL SCIENCES

Electron/proton spectrometer certification documentation analyses

A compilation of analyses generated during the development of the electron-proton spectrometer for the Skylab program is presented. The data documents the analyses required by the electron-proton spectrometer verification plan. The verification plan was generated to satisfy the ancillary hardware requirements of the Apollo Applications program. The certification of the spectrometer requires that various tests, inspections, and analyses be documented, approved, and accepted by reliability and quality control personnel of the spectrometer development program.

Gleeson, P.

Ultraviolet spectrometer experiment for the Voyager mission

An objective grating spectrometer covering the wavelength range of 500 to 1700 A with a 10-A resolution is employed for the Voyager ultraviolet spectrometer experiment. In determining the composition and structure of the atmospheres of Saturn, Jupiter and several satellites, the ultraviolet spectrometer will rely on airglow mode observations to measure radiation from the atmospheres due to resonant scattering of solar flux, and the occultation mode for assessments of the atmospheric extinction of solar or stellar radiation as the spacecraft enters shadow zones. Since it is capable of prolonged stellar observations in the 500 to 1000 A wavelength range, the spectrometer is expected to make important contributions to exploratory studies of UV sources.

Broadfoot, A. L.

RF spectrometers for heterodyne receivers

Several types of spectrometers developed for radio astronomy receivers which utilize RF filters, multiple oscillators and mixers, digital autocorrelators and acoustic/optic devices are considered. The RF spectrometer developed at GSFC to provide wide bandwidths (greater than 1 GHz) as well as high resolution (5MHz) is described. The 128 channel filter bank is divided into high and low resolution sections. The high resolution section is tunable by providing a second mixer ahead of the filter bank. This is necessary because infrared receivers which use gas lasers as local oscillators are only tunable to specific laser frequencies. To compensate for astronomical Doppler shifts and molecule frequency differences a second local oscillator and mixer is needed. A diagram of the RF section of the filter bank is shown. The RF spectrometer is shown to be the best means of achieving ultra-wide bandwidths for infrared heterodyne receivers. For high resolution with a large number of channels, the acousto/optical spectrometer is the principle instrument, particularly for balloon or space flight applications.

Buhl, D.

The Dynamics Explorer Wind and Temperature Spectrometer

The Wind and Temperature Spectrometer, designed to measure the concentration, kinetic temperature, and motion (three mutually perpendicular components of the wind) of the neutral particles, is described, noting that measurements of the concentration and velocity of the ambient thermal ions are also possible. Two of the three wind components, the temperature and the concentration of the dominant constituent, can be measured to an altitude of approximately 650 km; the third component can be measured to about 375 km (estimated). Ion measurements can be taken throughout the orbit. The quadrupole mass spectrometer is the principal sensor for the instrument. Measurements of the zonal and vertical components of the wind are made by interpreting the modulation of the particle stream entering the mass spectrometer, induced by baffles that scan slowly (one vertically and one horizontally) in front of the entrance port of the mass spectrometer.

N W Spencer

A hard X ray and soft gamma ray telescope spectrometer

A telescope spectrometer in the hard X-ray and soft gamma-ray region from 30 keV to 200 keV can provide significant information in investigations related to solar physics and planetary science. The present study is concerned with the preliminary design of such an instrument, taking into account a use of the Low Intensity X-ray Imaging Scope (Lixiscope). In the design of the considered telescope spectrometer, attention would have to be given to three major components, including the X-ray and gamma-ray input optics, an imaging detector-spectrometer, and an output processor. The preliminary results provided by the present study indicate that, in principle, a complete hard X-ray and soft gamma-ray telescope imaging spectrometer system using the Lixiscope is feasible. However, much work remains to be done with respect to the optimization and improvement of the system for future flight applications.

Yin, L. I.

Preliminary testing of a prototype portable X-ray fluorescence spectrometer

A portable X-ray fluorescence spectrometer for use as an analyzer in mineral resource investigative work was built and tested. The prototype battery powered spectrometer, measuring 11 by 12 by 5 inches and weighing only about 15 pounds, was designed specifically for field use. The spectrometer has two gas proportional counters and two radioactive sources, Cd (10a) and Fe (55). Preliminary field and laboratory tests on rock specimens and rock pulps have demonstrated the capability of the spectrometer to detect 33 elements to date. Characteristics of the system present some limitations, however, and further improvements are recommended.

Patten, L. L.