Search NASASearch

SEARCH · Search NASA

Results for “spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Atmospheric pressure chemical ionization of fluorinated phenols in atmospheric pressure chemical ionization mass spectrometry, tandem mass spectrometry, and ion mobility spectrometry

Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH.

NASA Discipline Environmental Health

Atmospheric pressure chemical ionization studies of non-polar isomeric hydrocarbons using ion mobility spectrometry and mass spectrometry with different ionization techniques

The ionization pathways were determined for sets of isomeric non-polar hydrocarbons (structural isomers, cis/trans isomers) using ion mobility spectrometry and mass spectrometry with different techniques of atmospheric pressure chemical ionization to assess the influence of structural features on ion formation. Depending on the structural features, different ions were observed using mass spectrometry. Unsaturated hydrocarbons formed mostly [M - 1]+ and [(M - 1)2H]+ ions while mainly [M - 3]+ and [(M - 3)H2O]+ ions were found for saturated cis/trans isomers using photoionization and 63Ni ionization. These ionization methods and corona discharge ionization were used for ion mobility measurements of these compounds. Different ions were detected for compounds with different structural features. 63Ni ionization and photoionization provide comparable ions for every set of isomers. The product ions formed can be clearly attributed to the structures identified. However, differences in relative abundance of product ions were found. Although corona discharge ionization permits the most sensitive detection of non-polar hydrocarbons, the spectra detected are complex and differ from those obtained with 63Ni ionization and photoionization. c. 2002 American Society for Mass Spectrometry.

Non-NASA Center

Advancing Aerosol Chemical Characterization and Vertical Profiling over the Southern Great Plains Using Uncrewed Aerial Sampling and Offline Aerosol Mass Spectrometry

Recent advancements in uncrewed aerial systems (UASs) and particulate matter (PM) analytical techniques have provided opportunities for atmospheric research. In this study, we deployed the Department of Energy’s fixed-wing ArcticShark UAS to examine PM 2.5 composition at varying altitudes─within and above the planetary boundary layer (PBL)─over the Southern Great Plains atmospheric observatory (SGP). A total of 22 flights were conducted across March, June, and August 2023. Composite filter samples were collected during each flight and analyzed with offline aerosol mass spectrometry (AMS), complemented by on-board real-time sensors and ground-based instrumentation, to provide a comprehensive view of regional aerosol characteristics. Results show clear vertical and seasonal differences in the aerosol composition. Relative to ground-level measurements, aloft samples exhibited shifts in the distribution of organic and inorganic PM, with the organic composition varying distinctly across seasons. Particulate organic nitrogen (ON) was elevated, with bulk compositions similar in March and June but strongly altered in August, likely driven by biomass burning and enhanced photochemical activity. Combined AMS and chemical ionization mass spectrometry analyses detected amines, amides, and amino acids. PM above the planetary boundary layer was enriched in oxidized organic aerosols, while ground-level PM contained higher nitrate and sulfate. Seasonal differences in aqueous-phase processing were also observed, which were strongest in March during persistent cloud cover and weaker in the drier August period, suggesting a shift from aqueous- to gas-phase SOA formation. In conclusion, these findings highlight the value of UAS in advancing PM measurements and vertical profiling of aerosol composition.

54 ENVIRONMENTAL SCIENCES

The use of ion mobility spectrometry and gas chromatography/mass spectrometry for the detection of illicit drugs on clandestine records

Illicit drug distribution has over the past decade grown tremendously from simple 'drug pushing' where drugs were distributed from poorly organized individuals to today's well organized and well financed drug cartels. This change to a more 'corporate-like' atmosphere has resulted in a greater use of record keeping to monitor the profits generated. The use of record keeping by drug distributors is not restricted to high level drug smugglers but is used at all levels within the distribution network. Dealers at all levels including street dealers are generally 'fronted', given on consignment quantities of drugs that they in turn sell to customers, thereby requiring the need for records to keep track of drug sales versus liabilities. These records because of their illicit nature are often encrypted to hide the fact that they are indeed records of drug transactions. The creation of a handwritten notation concerning a drug transaction is normally brought on because of a purchase or sale. In a sale, this is commonly accomplished through a consignment, or the designation of a quantity to a customer to whom that amount has been 'fronted'. Because this activity generates a debt, it follows that an accounting for payments made, as well as new transactions completed, is only logical. One of the most common means of representing these is through an 'accounting flow', in which payments are subtracted from a running balance while new sales are added to it. The examination of illicit drug records has been the key to the prosecution of numerous federal, state, and local drug cases for a number of years. The Document Section of the FBI Laboratory, through its Racketeering Records Analysis Unit (RRAU), has been involved in such analytical efforts since 1983. Detailed analytical research brought about an evolution in the systematic approach utilized in the RRAU since that time. The close proximity of the drugs to the records often results in trace drug evidence being transferred to the records. The detection of trace drug residue on surfaces by ion mobility spectrometry (IMS) is well documented in literature. The following procedure will deal primarily with the newer techniques of trace drug analysis and drug record analysis developed by the Chemistry/Toxicology Unit of the FBI Laboratory since the more traditional techniques of latent finger print analysis and document analysis are well known.

Donnelly, Brian

Energy Dispersive Spectrometry and Quantitative Analysis Short Course. Introduction to X-ray Energy Dispersive Spectrometry and Quantitative Analysis

This course will cover practical applications of the energy-dispersive spectrometer (EDS) to x-ray microanalysis. Topics covered will include detector technology, advances in pulse processing, resolution and performance monitoring, detector modeling, peak deconvolution and fitting, qualitative and quantitative analysis, compositional mapping, and standards. An emphasis will be placed on use of the EDS for quantitative analysis, with discussion of typical problems encountered in the analysis of a wide range of materials and sample geometries.

Carpenter, Paul

A universal language for finding mass spectrometry data patterns

Despite being information rich, the vast majority of untargeted mass spectrometry data are underutilized; most analytes are not used for downstream interpretation or reanalysis after publication. The inability to dive into these rich raw mass spectrometry datasets is due to the limited flexibility and scalability of existing software tools. Here, in this study, we introduce a new language, the Mass Spectrometry Query Language (MassQL), and an accompanying software ecosystem that addresses these issues by enabling the community to directly query mass spectrometry data with an expressive set of user-defined mass spectrometry patterns. Illustrated by real-world examples, MassQL provides a data-driven definition of chemical diversity by enabling the reanalysis of all public untargeted metabolomics data, empowering scientists across many disciplines to make new discoveries. MassQL has been widely implemented in multiple open-source and commercial mass spectrometry analysis tools, which enhances the ability, interoperability and reproducibility of mining of mass spectrometry data for the research community.

Damiani, Tito [Czech Academy of Sciences (CAS), Pr

Mass spectrometry.

Review of the current state of mass spectrometry, indicating its unique importance for advanced scientific research. Mass spectrometry applications in computer techniques, gas chromatography, ion cyclotron resonance, molecular fragmentation and ionization, and isotope labeling are covered. Details are given on mass spectrometry applications in bio-organic chemistry and biomedical research. As the subjects of these applications are indicated alkaloids, carbohydrates, lipids, terpenes, quinones, nucleic acid components, peptides, antibiotics, and human and animal metabolisms. Particular attention is given to the mass spectra of organo-inorganic compounds, inorganic mass spectrometry, surface phenomena such as secondary ion and electron emission, and elemental and isotope analysis. Further topics include mass spectrometry in organic geochemistry, applications in geochronology and cosmochemistry, and organic mass spectrometry.

Burlingame, A. L.

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION

Terrestrial imaging spectrometry - Current status, future trends

A review of recent progress in the field of imaging spectrometry is presented based on the 14 articles comprising the special issue of this journal. The results presented were achieved through research done with data from the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), the first imaging spectrometer to cover the full solar reflected portion of the spectrum. The majority of the early work in imaging spectrometry prior to AVIRIS focused largely on geological applications and specifically surface mineral identification. In the past 5 years, the range of applications has expanded into the scientific disciplines of ecology, hydrology, oceanography, and atmospheric science. Significant progress has also been made in sensor design and calibration, and information extraction. NASA plans to place high spectral resolution sensors in earth orbit within the next few years; two have been flown already on recent planetary missions and have proven to be of great value to the study of planetary surfaces and atmospheres. The work presented in this issue will lead directly to more effective utilization of imaging spectrometry in the study of the earth. We present a discussion of future trends in imaging spectrometry at the conclusion of this article.

Vane, Gregg

Mass spectrometry in the U.S. space program: past, present, and future

Recent years have witnessed significant progress on the miniaturization of mass spectrometers for a variety of field applications. This article describes the development and application of mass spectrometry (MS) instrumentation to support of goals of the U.S. space program. Its main focus is on the two most common space-related applications of MS: studying the composition of planetary atmospheres and monitoring air quality on manned space missions. Both sets of applications present special requirements in terms of analytical performance (sensitivity, selectivity, speed, etc.), logistical considerations (space, weight, and power requirements), and deployment in perhaps the harshest of all possible environments (space). The MS instruments deployed on the Pioneer Venus and Mars Viking Lander missions are reviewed for the purposes of illustrating the unique features of the sample introduction systems, mass analyzers, and vacuum systems, and for presenting their specifications which are impressive even by today's standards. The various approaches for monitoring volatile organic compounds (VOCs) in cabin atmospheres are also reviewed. In the past, ground-based GC/MS instruments have been used to identify and quantify VOCs in archival samples collected during the Mercury, Apollo, Skylab, Space Shuttle, and Mir missions. Some of the data from the more recent missions are provided to illustrate the composition data obtained and to underscore the need for instrumentation to perform such monitoring in situ. Lastly, the development of two emerging technologies, Direct Sampling Ion Trap Mass Spectrometry (DSITMS) and GC/Ion Mobility Spectrometry (GC/IMS), will be discussed to illustrate their potential utility for future missions. c 2001 American Society for Mass Spectrometry.

NASA Discipline Environmental Health

Predicting High‐Resolution Spatial and Spectral Features in Mass Spectrometry Imaging with Machine Learning and Multimodal Data Fusion

Recent advancements in molecular Mass Spectrometry Imaging have sparked interest in integrating high spatial resolution methods with molecular mass-spectrometry-based chemical imaging. Fusion-based algorithms have proven effective in generating high spatial-resolution molecular mass spectra. However, a significant challenge stems from the differing physical mechanisms underlying image generation and data upsampling techniques, potentially leading to discrepancies in integrated information channels. Integrating physical constraints into data processing workflows is essential to tackle this issue. In this study, we propose an innovative approach that merges data from Fourier transform ion cyclotron resonance (FTICR), time-of-flight matrix-assisted laser desorption/ionization, and time-of-flight secondary ion mass spectrometry imaging techniques. By leveraging FT-ICR's unparalleled spectral resolution and ToF-SIMS's exceptional spatial resolution, we achieve submicron spatial resolution, enabling the observation of intact molecular species with remarkable spectral precision. Canonical correlation analysis is employed to incorporate physical constraints. Through sophisticated image processing and machine learning techniques, the results of this fusion hold significant promise for advancing our comprehension of complex systems and unveiling concealed molecular intricacies.

canonical correlation analysis

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry