Search NASA⌕ Search

SEARCH · Search NASA

Results for “spinning reserve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

On Secured Spinning Reserve Deployment of Energy-Limited Resources Against Contingencies

Featured with fast response abilities and high ramp rates, energy storage systems (ESS), such as pumped-storage hydropower (PSH) plants and battery storage systems (BSS), are considered as key first-responders to provide spinning reserve in response to system contingencies. However, ESSs are energy-limited resources, and their sustained spinning reserve deployment is restricted by the stored energy and available capacity. Indeed, the spinning reserve deployment against contingencies may deviate actual state-of-charge (SOC) from the scheduled value, inducing potential SOC boundary violations and non-dispatchability in later hours. This paper proposes the post-contingency operation model and the spinning reserve secure constraints to address these issues. The post-contingency operation model describes that spinning reserve from ESSs is promptly deployed when contingency occurs, and then gradually substituted by quick-start units when they are switched online. By leveraging this operation strategy, spinning reserve secure constraints in terms of SOC headrooms are adopted to guarantee its deplorability. Furthermore, a modified IEEE 118-bus system with multiple PSHs and BSSs is used to verify the proposed approach.

13 HYDRO ENERGY↗

Regional Real-Time PV Spinning Reserve Estimator

Curtailed photovoltaic (PV) generation is a zero-marginal-cost spinning reserve that can be used for a number of active power control services. Unlike traditional spinning reserve providers, however, i.e., fossil-fueled generators, which have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate knowledge of the PV PHL is essential. It ensures that enough headroom is reserved by the PV plants to deliver the award services in real time and informs feasible dispatch decisions made by the market operator. To tackle this challenge, a novel reference-control grouping-based PV plant reserve estimation method has been proposed by the National Renewable Energy Laboratory under past projects funded by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office. The estimation method separates inverters within a plant into two groups: a control group and a reference group. While the reference group is reserved to operate at its PHL, the control group can be curtailed to provide the grid services. Real-time outputs from the reference inverters are used to estimate the PHL for the whole plant based on the ratio between capacities of the reference group and of the plant. This work further enhances the methodology by (1) improving the model accuracy through machine learning; (2) automating the reference inverter selection through correlation analysis; (3) considering estimation look-ahead windows; and (4) applying to regional spinning reserve estimation. Significant performance improvement has been observed based on real-world data collected by CAISO, Southern Company, and Terabase Energy. Compared with the original scaling method, the newly proposed machine learning-based approach reduces the estimation errors by 30% and 13% at the plant level and region level, respectively. Results obtained from this project are intended to be used by grid operators, market operators, balancing authorities, and PV plant owners and operators to facilitate PV participation in ancillary service markets. Regulators, policymakers, and system planners can also consider the results of this work in their decision-making processes. In addition to the performance improvement on the existing reference-control based grouping method, we also investigated how the variability of PV generation from a single PV inverter can be used to represent the variability of PV generation at the plant level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 99% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows: Preprint

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 1.6% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

The value of concentrating solar power in ancillary services markets

Ancillary services, such as spinning reserves, can provide grid reliability and contribute to profitability of an energy resource. We exercise an existing dispatch optimization model to estimate the profitability of a concentrating solar power plant by incorporating the sale of spinning reserves in the ancillary service market using the National Renewable Energy Laboratory's System Advisor Model to simulate operations within a 72-h rolling horizon framework. Assuming a price-taker approach with day-ahead energy and spinning reserve prices from both the California Independent System Operator and the Electricity Reliability Council of Texas, we find that selling spinning reserves in addition to electric energy increases plant profitability by up to 7% with perfect knowledge of day-ahead pricing and solar resource availability. Here, this finding suggests that spinning reserve markets provide significant value streams to concentrating solar power plants that can leverage thermal energy storage to offer reliable production in the short-to-medium term.

14 SOLAR ENERGY↗

Modifications to Solar Titan-130 Combustion Systems for Efficient, High Turndown Operation

The project team of Southwest Research Institute® (SwRI®), Solar Turbines Incorporated (Solar), the Electric Power Research Institute (EPRI), the University of California, Irvine (UCI), and the Georgia Institute of Technology (Georgia Tech) investigated methods to allow higher efficiency part-load operation of a Solar Titan 130 gas turbine. The objective was to develop a low-emission combustion system capable of sustaining combustion and avoiding lean blowout during high turndown operation, which would allow the gas turbine to operate as efficiently as possible at part load. Currently, electric utility markets are beginning to experience substantial increases in renewable energy generation. Some of these renewable energy sources have highly variable output in an uncontrolled manner. In order to maintain grid stability, there is a need for power plants to ramp up power to the grid rapidly to make up for drops in renewable generation. This is often termed spinning reserve, but the size of this reserve may need to increase as renewable penetration into the electric utility market increases. Small combined heat and power (CHP) power plants provide a promising option for meeting this spinning reserve requirement. In order to operate in spinning reserve while still meeting the heat requirements for the CHP, the gas turbine needs to operate efficiently at very low loads. Efficient, high turndown operations in this engine are limited by the lean flammability limit of the premixed combustion system. This project sought enhance the lean operability range of the Titan 130 combustor. First, the project team participated in a brainstorming activity and ultimately selected two concepts to explore: fuel augmentation with hydrogen (H2) to improve the stability at lean operating conditions and modifications to the fuel nozzle to improve the emissions performance at lean operating conditions. Analytical and laboratory investigations were accomplished by UCI to investigate the efficacy of H2 addition at improving lean blow out (LBO) limits and the resulting emissions. These investigations used a variety of chemical reactor network (CRN) and CFD models, validated against laboratory data, to model the impact of H 2 and inform the experimental efforts accomplished by SwRI and Solar. Ultimately, both the CRN and CFD models yielded generally good agreement with the experimental data below a particular temperature threshold. Atmospheric tests of a full-scale T130 annular combustor were performed at SwRI facilities in San Antonio, Texas, to investigate the use of H 2 addition. For these tests, the T130 combustion system remained largely unchanged; minor modifications were performed to the fuel ducting to allow for the safe use of H 2 . The test ultimately demonstrated that the addition of H 2 to the fuel mixture significantly increased the AFR ratio at which the combustor could operate. This improvement to the LBO limit should allow for less use of compressor bleed and less throttling needed by the inlet guide vanes (IGV). This in turn could result in more efficient operation of the gas turbine at lower load points. The second modification explored in this work was a direct modification to the T130 injector. The project team hypothesized that modifications to the pilot of the T130 injector could provide lower emissions at high turn-down operations. These modifications were manufactured and explored by the team at Solar. High pressure rig tests, originally slated to occur at SwRI, were ultimately accomplished by Solar to maintain overall project budget and mitigate cost growth attributable to supply chain issues and inflation. The pressurized rig tests ultimately showed that the SwRI Project No. 18.24153 - DE-EE0008415 Page 2 Final Technical Report January 24, 2024 modifications did not significantly alter the performance of the combustion system at the high turn-down conditions; both the modified injectors and the baseline configuration exhibited elevated emissions comparted to the full-load operating condition. A final set of studies performed by EPRI investigated the benefit-cost of flexible CHP as well as a grid interconnection study for the California Independent System Operator (CAISO) grid. These studies considered: traditional CHP with no spinning reserve available for on-demand grid support, 50% flexible CHP where 50% of the machine’s capacity is consumed by on-site baseload operations while providing an additional 50% capacity for on-demand grid support, and 70% flexible CHP where 70% of capacity is consumed on-site by baseload operations and 30% is available for on-demand grid support. In all cases, the analyses showed a benefit-to-cost ratio greater than unity implying a positive net present value for all configurations. However, the traditional CHP showed the most economic benefit. These results are sensitive to several factors, many of which are not fully known and may vary over time. Thus site owners must be convinced that taking up the increased costs and risks from flexible CHP would be worth implementing. As the grid in California and across the country transition to incorporate larger renewable energy generation, flexible CHP can provide much needed operating reserves and dispatchability. Alternative fuel options, such as hydrogen blending and biofuels, may also lower carbon intensities of CHP. Flexible CHP should be examined in the evolving market to understand innovative business models, changes market rules and services, and new technologies.

20 FOSSIL-FUELED POWER PLANTS↗

Using Energy Storage-Based Grid Forming Inverters for Operational Reserve in Hybrid Diesel Microgrids

In remote arctic communities, where access to a bulk electrical grid interconnection is not available, the implementation of islanded microgrids has been the most viable way to produce and distribute electricity services to their inhabitants. Historically, these islanded grids have relied primarily on diesel generators or hydropower resources to supply the baseload. However, this practice can result in increased expense due to the high costs associated with fuel transportation and the significant amounts of on-site storage necessary when fuel transportation is unavailable during winter months. In order to mitigate this problem, arctic microgrids have started to transition to a hybrid-source operational mode by incorporating renewable energy sources that are inherently variable in nature, such as wind or solar. Due to their highly stochastic behavior, these hybrid-source islanded microgrids can pose potential issues related to power quality due to introduction of rapid net load fluctuations and inability of diesel generators to respond rapidly. In addition, non-firm stochastic sources can require significant idling diesel generator resources to serve as spinning reserves, which is inefficient and wasteful. This work studies the problems that may arise in the transient dynamics of a real-world hybrid diesel microgrid when subjected to a loss of wind generation. Moreover, this work proposes a transition from a diesel spinning reserve to a battery energy-storage system (BESS) operating reserve scheme. The study of the proposed transition is important in establishing the fundamental implication of transient dynamics and the potential benefits of integrating a BESS as a spinning reserve in terms of stability, frequency nadir, and transient voltage deviation. The methods to investigate and validate the transient dynamics relied on both electromagnetic simulation models of GFMIs and a commercially available GFMI in an experimental power hardware-in-the-loop setup. The simulation results showed that the proposed operating reserve scheme improves the power quality of the system in terms of voltage deviation and frequency nadir when the microgrid is subjected to a loss of wind generation scenario. Depending on the simulation cases, adding a GFMI reduced the frequency nadir between 65.3% and 86.7%. Moreover, the reductions in the voltage deviations improved between 3.6% and 23.0%. From these results it can be concluded that the integration of a GFMI can reduce the frequency nadir in a hybrid diesel microgrid, and in turn, reduce diesel consumption, which improves system reliability while reducing fuel expenses. Furthermore, the novelty of this work relies on the fact that the offline simulation results were validated using a power hardware-in-the-loop platform that incorporated a 100 kVA commercially available GFMI as the device under test.

Hernandez-Alvidrez, Javier↗

Coordinated frequency regulation among asynchronous AC grids with an MTDC system

With the increasing penetration level of renewable power, the power systems’ inertias are decreasing. To ensure that the frequency is above the threshold of the under frequency load shedding, one effective way is to share the spinning reserves among asynchronous AC grids through HVDC systems. In this paper, a coordinated frequency regulation scheme that enables spinning reserves sharing is proposed for such hybrid AC/DC grids. This scheme is a communication-free method that consists of the droop control, the inertia emulation control and the frequency safety control. The combined response of the three controls can increase not only the frequency nadir but also the settled frequency of the disturbed grid. In addition, the hysteresis comparators and the power injection limits are adopted in the frequency regulation scheme to reduce the coupling effect among AC grids. Thus, under small and harmless disturbance, the frequency regulation scheme will be inactive; the disturbance in strong AC grids would not affect the weak AC systems. The frequency regulation scheme coordinates well with the automatic generation control of the grids. Furthermore, the feasibility and effectiveness of the proposed frequency regulation scheme are verified through simulation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Service Values of Generic Marginal Building Flexibility in Modeled 2030 U.S. Power Systems

The datasets include the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of generic, daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. The results should be interpreted along with the caveats listed in "Valuation of Building Flexibility: Grid Service Value for Initial Market Entrants in Projected 2030 United States Power Systems", which also documents the methods used for the study. The factors examined in the study include: grid scenario, region, original usage hour in the day (local time), and building flexibility parameters - efficiency, dissipation, and shifting window include max pre-shift and max post-shift. Filenames in the datasets: The filenames contain information on the grid scenario, and the building flexibility efficiency and dissipation. For example: MidCase_2030_efficiency1.25_dissipation0.05_value.csv contains all results under Mid RE 2020, efficiency = 1.25, and dissipation = 0.05. * MidCase = Mid RE Each .csv file contains: region: The location of the building flexibility, aligned with U.S. Energy Information Administration (EIA) National Energy Modeling System (NEMS) Electricity Market Module regions. max_pre_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift earlier. max_post_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift later. local_datetime: Original datetime of 1kWh of building energy consumption. local_orig_h: Original usage hour (1-24) of building energy consumption, ignores daylight saving. local_shift_to: The datetime to when building energy consumption shifts, if shifting happens. If no shifting occurs, this cell is left blank. energy: Net energy value of energy shifting. capacity: Net capacity value of energy shifting. shifting_value: Net energy plus capacity value of energy shifting. spin: Spin reserve value at the original datetime of consumption. flex: Flexible reserve value at the original datetime of consumption. reg: Regulation reserve value at the original datetime of consumption. total_profit: Assuming the building flexibility is capable of providing energy, capacity, and ancillary services, total profit is the maximum value of energy shifting value, spin reserve value, flexible reserve value, and regulation reserve value - one of the four choices at any given hour - because we do not allow its value to be double-counted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Data-Driven Method for Adaptive Reserve Requirement Estimation via Probabilistic Net Load Forecasting

The University of Colorado Boulder Boulder, CO, 80309, USA With the increasing penetration of renewable energy, power systems are subject to more uncertainty. This makes power system reserve scheduling more challenging. Most of the current reserve requirement determination methods calculate reserve requirements based on historical data, which does not consider the real-time or future system uncertainty. In this paper, a data-driven method is developed to determine the non-spinning reserve requirement (NSRR) in the Electric Reliability Council of Texas (ERCOT) system. The method follows the procedure of the current ERCOT method while adaptively determining the NSRR based on probabilistic net load forecasts. Case studies with two years of ERCOT data show that the developed method significantly reduces the NSRR by introducing an adaptive temporal resolution and update rate. Sensitivity analysis with different forecasting and percentile thresholds indicates the flexibility of the developed method.

non-spinning reserve↗

Method and system for providing flexible reserve power for power grid

An optimization-based method and system is disclosed to enable heterogeneous loads and distributed energy resources (DERs) to participate in grid ancillary services, such as spinning and non-spinning reserves, and ramping reserves. The method includes receiving inputs for decision parameters for optimizing an objective for obtaining flexible reserve power, solving the objective for obtaining flexible reserve power, determining a reserve power schedule for a prediction horizon for providing flexible reserve power based on the objective, generating a service bid based on the reserve power schedule for the power grid; and when the service bid is accepted, providing flexible reserve power to the power grid based on the service bid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Allocating Reserves in Active Distribution Systems for Tertiary Frequency Regulation

This paper proposes a cooperative game theory-based approach for reserve optimization to enable distributed energy resources (DERs) participate in tertiary frequency regulation. Tertiary frequency regulation schemes ensure that reserve requirements of primary and secondary frequency regulation are fulfilled with a minimum cost. While the available reserve from a single distribution system may not suffice tertiary frequency regulation, stacked reserve from several distribution systems can enable them participate in tertiary frequency regulation at scale. In this paper, a two-stage strategy is proposed to effectively and precisely allocate spinning reserve requirement from each DER in distribution systems. In the first stage, two types of characteristic functions are computed: worthiness index (WI) and power loss reduction (PLR). In the second stage, the equivalent Shapley values are computed based on the characteristic functions, which are used to determine distribution factors for reserve allocation among DERs. The effectiveness of the proposed method for allocating reserves among DERs is demonstrated through several case studies on modified versions of the IEEE 13-node and 33-node distribution systems.

Gautam, Mukesh↗

Improving operational flexibility of integrated energy system with uncertain renewable generations considering thermal inertia of buildings

Insufficient flexibility in system operation caused by traditional "heat-set" operating modes of combined heat and power (CHP) units in winter heating periods is a key issue that limits renewable energy consumption. In order to reduce the curtailment of renewable energy resources through improving the operational flexibility, a novel optimal scheduling model based on chance-constrained programming (CCP), aiming at minimizing the lowest generation cost, is proposed for a small-scale integrated energy system (IES) with CHP units, thermal power units, renewable generations and representative auxiliary equipments. In this model, due to the uncertainties of renewable generations including wind turbines and photovoltaic units, the probabilistic spinning reserves are supplied in the form of chance-constrained; from the perspective of user experience, a heating load model is built with consideration of heat comfort and inertia in buildings. To solve the model, a solution approach based on sequence operation theory (SOT) is developed, where the original CCP-based scheduling model is tackled into a solvable mixed-integer linear programming (MILP) formulation by converting a chance constraint into its deterministic equivalence class, and thereby is solved via the CPLEX solver. We report the simulation results on the modified IEEE 30-bus system demonstrate that the presented method manages to improve operational flexibility of the IES with uncertain renewable generations by comprehensively leveraging thermal inertia of buildings and different kinds of auxiliary equipments, which provides a fundamental way for promoting renewable energy consumption.

30 DIRECT ENERGY CONVERSION↗

Optimal operation and sizing of pumped thermal energy storage for net benefits maximization

Abstract Current trends in the modern grid are leading to the development and deployment of energy storage to help integrate increasing variable renewable energy sources into the grid. This paper studies a pumped thermal energy storage (PTES) system for multiple grid services including energy arbitrage, frequency regulation, spinning and non‐spinning reserve, and resource adequacy. Optimal dispatch methods are proposed for individual services as well as value stacking from multiple services to maximize the economic benefits. Assessment results demonstrate the superiority of value stacking. Specifically, the study shows the maximum revenue from an individual grid service with a 30‐MWh PTES system was $522,520, while the value stacking could increase the benefits to $678,477. In addition, sensitivity analyses were conducted to explore the cost‐effectiveness of a PTES system with different combinations of power transfer limits and energy capacity. It was found that the power transfer limit had a greater impact than the energy capacity on the benefits. The proposed method could help determine the optimal duration of a future PTES system.

25 ENERGY STORAGE↗

Fast Frequency Response using Reinforcement Learning-Controlled Wind Turbines

To fulfill the auxiliary grid services such as load regulation, spin and non-spin reserve, and frequency support during emergencies, power system operators often require certain wind farms to operate in de-loaded modes. By leveraging the fast response capability of wind farms, the reserved power in deloaded modes can significantly enhance the stability and reliability of power grids. This paper presents a novel methodology that incorporates wind turbines into reinforcement learning-based solutions for frequency response. The proposed approach employs the state-of-the-art reinforcement learning algorithm, surrogategradient- based evolution strategy (GSES), for continuous control of the wind farm output. Our methodology is tested on a modified IEEE-39 bus system, and simulation outcomes demonstrate that the proposed approach can reliably support the frequency of the power system and prevent unnecessary load shedding.

Gao, Wei↗

Deep Reinforcement Learning Based Control of Wind Turbines for Fast Frequency Response

In order to fulfill vital auxiliary grid services, such as load regulation, spin and non-spin reserve provision, and frequency support during emergencies, there is often a requirement for certain wind farms to operate in de-loaded modes. Leveraging the swift response capabilities of wind farms, this study demonstrates that reserving power in de-loaded modes can significantly enhance power grid stability and reliability during system contingencies. Controlling wind farms optimally for frequency support is intricate due to the nonlinearity of models and controllers and the complexity of wind farm interactions with power systems. Here, to address this challenge, this paper introduces a novel approach that integrates wind turbines into reinforcement learning-based solutions for frequency response. This innovative methodology utilizes the state-of-the-art reinforcement learning algorithm known as the surrogate-gradient-based evolutionary strategy. The proposed learning-based algorithm provides continuous control of wind farm output to rapidly stabilize system frequency and prevent unnecessary trips of under-frequency load shedding relays. To facilitate efficient training, parallel computing techniques are employed. The proposed methodology is evaluated on a modified IEEE-39 bus system, and simulation results reveal its efficacy in reliably supporting power system frequency and preventing the need for unnecessary load shedding.

Gao, Wei [Argonne National Laboratory (ANL), Argon↗

Distributed Wind Controls: A Research Roadmap for Microgrids, Infrastructure Resilience, and Controls Launchpad (MIRACL)

The Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project’s controls research area aims to expand the benefits from distributed wind (DW) generation assets beyond solely providing low cost power directly to consumers. To make distributed wind turbines operate more effectively there is a need for more advanced ways to control them, allowing power companies, businesses, and energy consumers to take advantage of the unique characteristics of wind energy. DW can contribute to the safe and secure operation of grid by providing services such as voltage regulation, frequency regulation, spinning reserves, and even black start capabilities. In the larger DER context where much of the research has focused around solar technologies, the inertia available in wind technologies has generally not been considered. For wind turbines to provide these services in an optimal and expanded way, development and demonstration of control methods and communication interfaces within a grid and microgrid framework are required. In this document, NREL led the literature review in collaboration with SNL, of DER controls-focused integration research to establish a baseline for the controls research under the MIRACL project to identify specific control functions to be focused on throughout this project. This literature review focused primarily on the control functions of variable distributed generation, largely pulling from past solar PV and battery controls works, with a specific focus on applicability for distributed wind energy systems. The goal of this document is to identify a research roadmap based on the open literature and past national laboratory works to inform advanced wind turbine and power electronics control functions for four use cases: 1) distributed wind in isolated systems, 2) grid-connected microgrids (wind-hybrid systems and islanded operation), 3) behind-the-meter distributed wind applications in the power distribution systems, and 4) front-of-the-meter distributed wind applications in the power distribution systems.

17 WIND ENERGY↗