Search NASA⌕ Search

SEARCH · Search NASA

Results for “sprays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hydrogen no-vent fill testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗

Hydrogen no-vent testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗

Spray applicator for spraying coatings and other fluids in space

A self contained spray application is developed for one handed operation in a zero gravity vacuum environment by a free flying astronaut not attached to any spacecraft. This spray applicator eliminates contamination of the operator by back spray. This applicator includes a rigid accumulator containment of a fluid within a flexible bladder the fluid being urged out of the accumulator under pressure through a spray gun. The spray gun includes a spring loaded lockable trigger which controls a valve. When in an open position, the fluid passes through the valve into the ambient environment in the form of a spray. A spray shield is provided which directs the flow of the spray from the applicator by trapping errant particles of spray yet allowing the passage of escaping gases through its material.

Kuminecz, J. F.↗

Representation of the vaporization behavior of turbulent polydisperse sprays by equivalent monodisperse sprays

The concept of using an equivalent monodisperse spray to represent the vaporization behavior of polydisperse sprays has been examined by numerically solving two turbulent vaporizing sprays. One involves the injection of Freon-11 in a still environment, whereas the other is a methanol spray in a still but hot environment. The use of three different mean sizes, namely, Sauter mean diameter, volume median diameter, and surface-area mean diameter, has been investigated. Results indicate a good degree of correlation between the polydisperse spray and its equivalent monodisperse sprays represented by the volume median diameter and the Sauter mean diameter, the former giving slightly better results. The surface-area mean diameter does not provide as good a correlation as the other two mean diameters.

Aggarwal, S. K.↗

Representation of the vaporization behavior of turbulent polydisperse sprays by 'equivalent' monodisperse sprays

The concept of using an equivalent monodisperse spray to represent the vaporization behavior of polydisperse sprays has been examined by numerically solving two turbulent vaporizing sprays. One involves the injection of Freon-11 in a still environment, whereas the other is a methanol spray in a still but hot environment. The use of three different mean sizes, namely, Sauter mean diameter, volume median diameter, and surface-area mean diameter, has been investigated. Results indicate a good degree of correlation between the polydisperse spray and its equivalent monodisperse sprays represented by the volume median diameter and the Sauter mean diameter, the former giving slightly better results. The surface-area mean diameter does not provide as good a correlation as the other two mean diameters.

Aggarwal, S. K.↗

Effects of Nose Shape and Spray Control Strips on Emergence and Planing Spray of Hydro-ski Models

The emergence and planing-spray characteristics of flat-bottom surfaces representative of hydro-skis with various bow shapes and deflectors were investigated for trims of 12° and 20° and a speed of 30 feet per second. The emergence-spray characteristics of the models with various bow shapes were investigated for depths of submersion of the bow from 0.50 inch to -0.50 inch. The planing-spray characteristics of the models with the various deflectors were determined for a draft corresponding to a length-beam ratio of 4 . The emergence- and planing-spray patterns are shown in the photographs taken from forward of and above the models and from the side of the models. The most favorable emergence spray was obtained with a bow of triangular plan form and sharp profile. The greatest improvement in planing spray was obtained with vertical chine strips and a transverse barrier strip located forward of the wetted planing area.

John R McGehee↗

Characterization and durability testing of plasma-sprayed zirconia-yttria and hafnia-yttria thermal barrier coatings. Part 1: Effect of spray parameters on the performance of several lots of partially stabilized zirconia-yttria powder

Initial experiments conducted on thermal barrier coatings prepared in the newly upgraded research plasma spray facility and the burner rig test facilities are discussed. Part 1 discusses experiments which establish the spray parameters for three baseline zirconia-yttria coatings. The quality of five similar coating lots was judged primarily by their response to burner rig exposure supplemented by data from other sources such as specimen characterizations and thermal diffusivity measurements. After allowing for burner rig variability, although there appears to be an optimum density (i.e., optimum microstructure) for maximum burner rig life, the distribution tends to be rather broad about the maximum. In Part 2, new hafnia-yttria-based coatings were evaluated against both baseline and alternate zirconia-yttria coatings. The hafnia-yttria coatings and the zirconia-yttria coatings that were prepared by an alternate powder vendor were very sensitive to plasma spray parameters, in that high-quality coatings were only obtained when certain parameters were employed. The reasons for this important observation are not understood. Also not understood is that the first of two replicate specimens sprayed for Part 1 consistently performed better than the second specimen. Subsequent experiments did not display this spray order affect, possibly because a chiller was installed in the torch cooling water circuit. Also, large changes in coating density were observed after switching to a new lot of electrodes. Analyses of these findings were made possible, in part, because of the development of a sensitive density measurement technique described herein in detail. The measured thermal diffusivities did not display the expected strong relationship with porosity. This surprising result was believed to have been caused by increased microcracking of the denser coatings on the stainless steel substrates.

Miller, Robert A.↗

Spray characterization and turbulence properties in an isothermal spray with swirl

In the present experimental study of the effects of swirl on the dynamic behavior of drops and on the velocity and turbulence fields of an isothermal spray, using a two-component phase Doppler particle analyzer, mean velocity and turbulence properties were obtained for the gas phase. Large differences are noted in the spatial distribution of the drops over the spray's size, velocity, and number density, when the spray in coflowing air is compared with the atomizer spraying into the swirling flow field with the same axial velocity. The turbulence properties of the swirling flow exhibit significant influence on the dynamic behavior of the drops.

Brena De La Rosa, A.↗

Spray nozzle investigation for the Improved Helicopter Icing Spray System (IHISS)

A contract has been awarded by the U.S. Army to design, fabricate and test a replacement for the existing Helicopter Icing Spray System. Data are shown for extensive bench and icing tunnel test programs used to select and modify an improved spray nozzle. The IHISS, capable of deployment from any CH-47 helicopter, will include new icing spray nozzles and pneumatic pressure source, and a significantly larger water tank and spray boom. The resulting system will provide a significantly larger icing cloud with droplet characteristics closely matching natural icing conditions.

Peterson, Andrew A.↗

Automated Plasma Spray (APS) process feasibility study: Plasma spray process development and evaluation

An automated plasma spray (APS) process was developed to apply two layer (NiCrAlY and ZrO2-12Y2O3) thermal-barrier coatings to aircraft gas turbine engine blade airfoils. The APS process hardware consists of four subsystems: a mechanical blade positioner incorporating two interlaced six-degree-of-freedom assemblies; a noncoherent optical metrology subsystem; a microprocessor-based adaptive system controller; and commercial plasma spray equipment. Over fifty JT9D first stage turbine blades specimens were coated with the APS process in preliminary checkout and evaluation studies. The best of the preliminary specimens achieved an overall coating thickness uniformity of + or - 53 micrometers, much better than is achievable manually. Factors limiting this performance were identified and process modifications were initiated accordingly. Comparative evaluations of coating thickness uniformity for manually sprayed and APS coated specimens were initiated. One of the preliminary evaluation specimens was subjected to a torch test and metallographic evaluation.

Fetheroff, C. W.↗

Detailed investigation of a vaporising fuel spray. Part 1: Experimental investigation of time averaged spray

A laser tomographic light scattering technique provides rapid and accurate high resolution measurements of droplet sizes, concentrations, and vaporization. Measurements using a computer interfaced thermocouple are presented and it is found that the potential exists for separating gas and liquid temperature measurements and diagnosing local spray density by in situ analysis of the response characteristics of the thermocouple. The thermocouple technique provides a convenient means for measuring mean gas velocity in both hot and cold two phase flows. The experimental spray is axisymmetric and has carefully controlled initial and boundary conditions. The flow is designed to give relatively insignificant transfer of momentum and mass from spray to air flow. The effects of (1) size-dependent droplet dispersion by the turbulence, (2) the initial spatial segregation of droplet sizes during atomization, and (3) the interaction between droplets and coherent large eddies are diagnosed.

Yule, A. J.↗

Fuel spray measurements with an imaging-type spray analyzer

The application of an imaging-type, automated spray analysis system to measurements of fuel sprays requires consideration of a number of significant factors both in its use and in the interpretation of the data. These factors are reviewed and a procedure developed for one such instrument is described. The procedure involves optical scans along the optic axis of the system and an appropriate mathematical inversion scheme for interpretation of the results. The system is nominally capable of yielding the local size distribution function and the total number density at points along the optic axis for droplets from about 10 to 500 microns. No assumptions regarding the form of the size distribution function or the symmetry of the spray are required.

Skifstad, J. G.↗

Characterization and durability testing of plasma-sprayed zirconia-yttria and hafnia-yttria thermal barrier coatings. Part 2: Effect of spray parameters on the performance of several hafnia-yttria and zirconia-yttria coatings

This is the second of two reports which discuss initial experiments on thermal barrier coatings prepared and tested in newly upgraded plasma spray and burner rig test facilities at LeRC. The first report, part 1, describes experiments designed to establish the spray parameters for the baseline zirconia-yttria coating. Coating quality was judged primarily by the response to burner rig exposure, together with a variety of other characterization approaches including thermal diffusivity measurements. That portion of the study showed that the performance of the baseline NASA coating was not strongly sensitive to processing parameters. In this second part of the study, new hafnia-yttria coatings were evaluated with respect to both baseline and alternate zirconia-yttria coatings. The hafnia-yttria and the alternate zirconia-yttria coatings were very sensitive to plasma-spray parameters in that high-quality coatings were obtained only when specific parameters were used. The reasons for this important observation are not understood.

Miller, Robert A.↗

Evaluation of Convergent Spray Technology(TM) Spray Process for Roof Coating Application

The overall goal of this project was to demonstrate the feasibility of(CST) Convergent Spray Technology (Trademark) for the roofing industry. This was accomplished by producing an environmentally compliant coating utilization recycled materials, a CST(Trademark) spray process portable application cart, and hand-held applicator with a CST(Trademark) spray process nozzle. The project culminated with application of this coating to a nine hundred sixty square foot metal for NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama.

COATINGS↗

Vision-aided Monitoring and Control of Thermal Spray, Spray Forming, and Welding Processes

Vision is one of the most powerful forms of non-contact sensing for monitoring and control of manufacturing processes. However, processes involving an arc plasma or flame such as welding or thermal spraying pose particularly challenging problems to conventional vision sensing and processing techniques. The arc or plasma is not typically limited to a single spectral region and thus cannot be easily filtered out optically. This paper presents an innovative vision sensing system that uses intense stroboscopic illumination to overpower the arc light and produce a video image that is free of arc light or glare and dedicated image processing and analysis schemes that can enhance the video images or extract features of interest and produce quantitative process measures which can be used for process monitoring and control. Results of two SBIR programs sponsored by NASA and DOE and focusing on the application of this innovative vision sensing and processing technology to thermal spraying and welding process monitoring and control are discussed.

Agapakis, John E.↗

Development of a Convergent Spray Technologies(tm) Spray Process for a Solventless Sprayable Coating, MCC-1

This paper discusses the application of Convergent Spray Technologies (TM) Spray Process to the development and successful implementation of Marshall Convergent Coating (MCC-1) as a primary Thermal Protection System (TPS) for the Space Shuttle Solid Rocket Boosters (SRBs). This paper discusses the environmental and process benefits of the MCC-1 technology, shows the systematic steps taken in developing the technology, including statistical sensitivity studies of about 35 variables. Based on the process and post-flight successes on the SRB, it will be seen that the technology is "field-proven". Application of this technology to other aerospace and commercial programs is summarized to illustrate the wide range of possibilities.

Patel, Anil K.↗