Search NASA⌕ Search

SEARCH · Search NASA

Results for “spread spectrum time-domain reflectometry (SSTDR)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A SSTDR Methodology, Implementations, and Challenges

Sequence time-domain reflectometry (STDR) and spread spectrum time-domain reflectometry (SSTDR) detect, locate, and diagnose faults in live (energized) electrical systems. In this paper, we survey the present SSTDR literature for discussions on theory, algorithms used in its analysis, and its more prominent implementations and applications. Our review includes both scientific litera-ture and selected patents. We also discuss future applications of SSTDR.

14 SOLAR ENERGY↗

Capability of Impedance Measurement Using Spread Spectrum Time-Domain Reflectometry

Spread spectrum time-domain reflectometry (SSTDR) has been proposed for measuring electrical impedance on live, energized systems, in electrically noisy environments, or for measuring multiple channels simultaneously. Here we evaluate the capability of SSTDR for impedance measurement from near dc to 96 MHz and find that they agree very well with measurements from a vector network analyzer (VNA). Time gating is used to remove (calibrate out) transmission line effects. We evaluate the frequency ranges over which SSTDR at different modulation frequencies is accurate for the measurement of series resistive–capacitive ( RC ) loads and observe that fusing measurements from multiple modulation frequencies can broaden the effective measurement bandwidth.

14 SOLAR ENERGY↗

Detection and Localization of Disconnections in PV Strings Using Spread-Spectrum Time-Domain Reflectometry

This article describes the novel use of spread-spectrum time-domain reflectometry (SSTDR) for detecting and locating disconnection faults in photovoltaic (PV) power plants. We measure strings of cells and full-sized modules to understand how disconnections affect the reflectometry signature. PV modules correspond to reactive loads and disconnections in a PV string and cause distinguishable and measurable changes in SSTDR responses. Disconnection faults are manually introduced and correctly identified and localized applying the proposed technique. The SSTDR technique can detect and locate disconnects through at least eight 36-cell modules. Using the new technique described in this article, we can both detect and locate the disconnections within a 1-ft resolution, on average.

14 SOLAR ENERGY↗

Spread Spectrum Time-Domain Reflectometry and Frequency Domain Reflectometry to Detect Shielded and Unshielded Cable Moisture Exposure

This work evaluates the feasibility to extend spread spectrum time-domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) electrical cable testing to characterize whether an electrical cable is submerged in water or not and where it may be submerged. Using PNNL’s ARENA cable and motor test bed, shielded and non-shielded electrical cables were evaluated using SSTDR and FDR methods to detect and locate electrical cable exposure to water. Both SSTDR and FDR showed the presence of water with a non-shielded cable. Moisture was only detectable with the shielded cable if the insulation was damaged.

reflectometry cable test, cable moisture detection↗

Postprocessing for Improved Accuracy and Resolution of Spread Spectrum Time-Domain Reflectometry

Reflectometry, which is commonly used for locating faults on electrical wires, produces sampled time domain signatures with peaks that are often missed due to this sampling. Resultant errors in these sampled peaks translate to errors in calculating the impedance and location of the fault. Typical signal processing methods to improve the accuracy of these sampled peaks have complexity on the order of O(N 2 ). For embedded fault location applications, algorithms with lower complexity are desired. In this article, we introduce three algorithms for improving the accuracy of the peak with a complexity of O(N). Finally, we evaluate these algorithms on the practical case of calculating the velocity of propagation and the characteristic impedance of a photovoltaic (PV) cable using spread spectrum time-domain reflectometry.

47 OTHER INSTRUMENTATION↗

Detection and Localization of Damaged Photovoltaic Cells and Modules Using Spread Spectrum Time Domain Reflectometry

The operating efficiency of photovoltaic (PV) plants can be improved if damaged or degraded modules can be detected and identified. Currently, string-level power electronics can detect problems with modules or cabling but not locate them, which would facilitate addressing these issues. Here, we investigate the ability of spread spectrum time domain reflectometry (SSTDR) to both detect and locate/identify damaged cells and modules within a series-connected PV string. We tested the ability of SSTDR to detect and locate single-cell mini-modules and full-sized PV modules, which were intentionally damaged by impacts with a hammer (breaking the glass and damaging the silicon below) or by cutting through some or all busbars. Damage to the glass and silicon of cells was detected and located within a small string of minimodules. Busbar damage was detectable only if an open was created by cutting through all intercell busbars. Furthermore, physical impact damage to the glass and silicon of a full-sized PV module could be detected, but further development of signal processing is needed to achieve localization of such damaged modules within a string.

14 SOLAR ENERGY↗