Search NASA⌕ Search

SEARCH · Search NASA

Results for “squids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Spread-Spectrum SQUID Multiplexer

The transition-edge sensor (TES) is a mature, high-resolution x-ray spectrometer technology that provides a much higher efficiency than dispersive spectrometers such as gratings and crystal spectrometers. As larger arrays are developed, time-division multiplexing schemes operating at MHz frequencies are being replaced by microwave SQUID multiplexers using frequency-division multiplexing at GHz frequencies. However, the multiplexing factor achievable with microwave SQUIDs is limited by the high slew rate on the leading edge of x-ray pulses. In this paper, we propose a new multiplexing scheme for high-slew-rate TES x-ray calorimeters: the spread-spectrum SQUID multiplexer, which has the potential to enable higher multiplexing factors, especially in applications with lower photon-arrival rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flux-coherent series SQUID array magnetometers operating above 77 K with superior white flux noise than single-SQUIDs at 4.2 K

A very promising direction to improve the sensitivity of magnetometers based on superconducting quantum interference devices (SQUIDs) is to build a series-array of N non-interacting SQUIDs operating flux-coherently, because in this case their voltage modulation depth, ΔV, linearly scales with N whereas the white flux noise S{sub Φ}{sup 1/2} decreases as 1/N{sup 1/2}. Here, we report the realization of both these improvements in an advanced layout of very large SQUID arrays made of YBa{sub 2}Cu{sub 3}O{sub 7}. Specially designed with large area narrow flux focusers for increased field sensitivity and improved flux-coherency, our arrays have extremely low values for S{sub Φ}{sup 1/2} between (0.25 and 0.44) μΦ{sub 0}/Hz{sup 1/2} for temperatures in the range (77–83) K. In this respect, they outperform niobium/aluminium trilayer technology-based single-SQUIDs operating at 4.2 K. Moreover, with values for ΔV and transimpedance in the range of (10–17) mV and (0.3–2.5) kΩ, respectively, a direct connection to a low-noise room temperature amplifier is allowed, while matching for such readout is simplified and the available bandwidth is greatly increased. These landmark performances suggest such series SQUID arrays are ideal candidates to replace single-SQUIDs operating at 4.2 K in many applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A nanoscale SQUID operating at high magnetic fields

A washer-free Nb nanoSQUID has been developed for measuring magnetization changes from nanoscale objects. The SQUID loop is etched into a 250 nm wide Au/Nb bilayer track and the diameter of the SQUID hole is ~ 70 nm. In the presence of a magnetic field perpendicular to the plane of the SQUID, vortex penetration into the 250 nm wide track can be observed via the critical current–applied field characteristic and the value at which vortex first penetrates is consistent with the theoretical prediction. Upon removing the applied field, the penetrated vortices escape the track and the critical current at zero field is restored.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simple correction for the sample shape and radial offset effects on SQUID magnetometers: Magnetic measurements on Ln{sub 2}O{sub 3} (Ln=Gd, Dy, Er) standards

An increased focus on magnetic measurements of oriented single crystals, thin films, and magnetically dilute systems has led to a demand for the measurement of weak magnetic moments. This level of sensitivity and precision can be achieved on SQUID magnetometers by decreasing the size of the detection coils. However, the smaller detection coils can amplify two errors in the magnitude of the measured moment, the sample shape and radial offset effects, which were small and typically unaccounted for on previous magnetometers. We report a simple method to determine the radial offset of a sample by taking advantage of the two basic scan modes, DC and lock-in, typically used on magnetometers. This technique allows for the correction of the sample shape and radial offset effects in order to obtain the true moment of a sample. To show the efficacy of this technique, we report the magnetic properties of Ln{sub 2}O{sub 3} (Ln=Gd, Dy, Er). - Graphical abstract: Correction for the sample shape and radial offset effects on SQUID magnetometers using a combination of DC and VSM scan data. - Highlights: • Sample shape and radial offset effects alter the moment measured by magnetometers. • We present a simple method to correct for these sample effects on magnetometers. • We measure magnetic susceptibilities of Ln{sub 2}O{sub 3} to show the efficacy of this method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Antiferromagnetic and nematic phase transitions in BaF e 2 ( A s 1 - x P x ) 2 studied by ac microcalorimetry and SQUID magnetometry

In this work, we study the antiferromagnetic (AFM) and structural phase transitions in single-crystal BaF e 2 ( A s 1 – x P x ) 2 ( x = 0 , 0.3 ) at temperatures T N and T S , respectively, by high-resolution ac microcalorimetry and SQUID magnetometry. The specific heat measurements of both as-grown and annealed BaF e 2 A s 2 display a sharp peak at the AFM-structural transitions. A kink in the entropy of annealed BaF e 2 A s 2 gives evidence for splitting of the two transitions by approximately 0.5 K. No additional features could be identified in the specific heat of both BaF e 2 A s 2 and BaF e 2 ( A s 0.7 P 0.3 ) 2 in the temperature regions around T * > T S where torque measurements had revealed the “true” nematic phase transition, even though the Ginzburg-Landau model used to fit the magnetic torque data indicates that the expected thermal anomaly should be easily observable with our experimental resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences↗

Quantum interference of currents in an atomtronic SQUID

Quantum interference of currents is the most important and well known quantum phenomenon in a conventional superconducting quantum interference device (SQUID). Here, we report the observation of quantum interference of currents in an atomtronic SQUID. Analogous to a conventional SQUID, currents flowing through two junctions in an atomtronic SQUID interfere due to the phase difference from rotation. This interference results in modulation of critical currents. This modulation was observed for three different radii with clear modulation periods which were measured to be consistent with fundamental rotation rates. This observation shows the possibility of studying various interesting SQUID physics with an atomtronic SQUID and especially, macroscopic quantum phenomena with currents may be realized with an atomtronic SQUID toward the goal of quantum metrology of rotation sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise limits for dc SQUID readout of high- Q resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m 3 axion search, which uses dc SQUIDs in this frequency range.

Bosons↗

A Scalable Readout for Microwave SQUID Multiplexing of Transition-Edge Sensors

The readout requirements for instruments based on transition-edge sensors (TESs) have dramatically increased over the last decade as demand for systems with larger arrays and faster sensors has grown. Emerging systems are expected to contain many thousands of sensors and/or sensors with time constants as short as 100 ms. These requirements must be satisfied while maintaining low noise, high dynamic range, and low crosstalk. A promising readout candidate for future TES arrays is the microwave SQUID multiplexer, which offers several gigahertz of readout bandwidth per pair of coaxial cables. In microwave SQUID multiplexing, sensor signals are coupled to RF-SQUIDs embedded in superconducting microwave resonators, which are probed via a common microwave feedline and read out using gigahertz signals. This form of SQUID multiplexing moves complexity from the cryogenic stages to room temperature hardware and digital signal processing firmware which must synthesize the microwave tones and process the information contained within them. To demultiplex signals from the microwave SQUID multiplexer, we have implemented an FPGA-based firmware architecture that is flexible enough to read out a variety of differently optimized TESs. A gamma-ray spectrometer targeted at nuclear materials accounting applications, known as SLEDGEHAMMER, is an early adopter of microwave SQUID multiplexing and is driving our current firmware development effort. This instrument utilizes 300 kHz full-width half-maximum resonators with 256 channels in a one gigahertz wide band. We have recently demonstrated undegraded readout of 128 channels using two ROACH2s on a single pair of coaxial cables. This manuscript describes the firmware implementation for the readout electronics of these early array-scale demonstrations.

42 ENGINEERING↗

Coupled Serial and Parallel Non-uniform SQUIDs

In this work we numerical model series and parallel non-uniform superconducting quantum interference device (SQUID) array. Previous work has shown that series SQUID array constructed with a random distribution of loop sizes, (i.e. different areas for each SQUID loop) there exists a unique 'anti-peak' at the zero magnetic field for the voltage versus applied magnetic field (V-B). Similar results extend to a parallel SQUID array where the difference lies in the arrangement of the Josephson junctions. Other system parameter such as bias current, the number of loops, and mutual inductances are varied to demonstrate the change in dynamic range and linearity of the V-B response. Application of the SQUID array as a low noise amplifier (LNA) would increase link margins and affect the entire communication system. For unmanned aerial vehicles (UAVs), size, weight and power are limited, the SQUID array would allow use of practical 'electrically small' antennas that provide acceptable gain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of DC SQUID Damping Effects on Superconducting Resonant Circuits

Here, we present experimental measurements of SQUID-induced damping effects on strongly coupled, lumped-element resonators in the 500kHz–1 MHz frequency range. While dc SQUIDs are commonly used for sensitive readout of electromagnetic signals such as in lumped-element axion dark matter searches, coupling a dc SQUID to a resonant circuit modifies the circuit's resonance frequency, quality factor, noise, and impedance. These parameters have a direct impact on the science reach of axion dark matter detectors, making it important to understand SQUID damping contributions. We describe a helium dip probe and two-stage SQUID readout scheme used to probe SQUID damping effects. Measurements from this setup inform the design and operation of both future test platforms as well as next-generation dark-matter experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bulk-SQUID effect in a discrete superconductor as a consequence of generation frequency locking in constituent josephson junctions

The theory of the bulk-SQUID effect in discrete superconductors is constructed for the first time. It is shown that the bulk-SQUID effect emerges in the system of 2D intrinsically stochastic multijunction SQUID (i.e., with random values of critical currents of the junctions, injection currents, and the coupling coefficients between the junction) due to generation frequency locking in all junctions. It is demonstrated that the bulk-SQUID effect occurs in a wide range of random parameters of the system. This domain of variation of the system parameters can be divided into three subdomains. The first one is the subdomain of coherent dynamics of phases at the junctions, the second is the subdomain of incoherent dynamics, in which the phases of the junctions are not locked, but the bulk-SQUID effect persists, and the third is the subdomain of transient dynamics, in which coherent dynamics and the bulk-SQUID effect are observed in parts. A simple mathematical model of noninteracting junctions, which correctly describes basic features of the dynamics of the initial system and makes it possible to calculate some of its statistical characteristics, is proposed and analyzed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of Resonances on the Noise Performance of SQUID Susceptometers

Scanning Superconducting Quantum Interference Device (SQUID) Susceptometry simultaneously images the local magnetic fields and susceptibilities above a sample with sub-micron spatial resolution. Further development of this technique requires a thorough understanding of the current, voltage, and flux ( I V Φ ) characteristics of scanning SQUID susceptometers. These sensors often have striking anomalies in their current–voltage characteristics, which we believe to be due to electromagnetic resonances. The effect of these resonances on the performance of these SQUIDs is unknown. To explore the origin and impact of the resonances, we develop a model that qualitatively reproduces the experimentally-determined I V Φ characteristics of our scanning SQUID susceptometers. We use this model to calculate the noise characteristics of SQUIDs of different designs. We find that the calculated ultimate flux noise is better in susceptometers with damping resistors that diminish the resonances than in susceptometers without damping resistors. Such calculations will enable the optimization of the signal-to-noise characteristics of scanning SQUID susceptometers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG

Abstract Objective. Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject’s scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses. Approach. We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding. Main results. OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement. Significance. The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain–computer interfacing.

Iivanainen, Joonas (ORCID:0000000160344604)↗

OpenSQUID: A Flexible Open-Source Software Framework for the Control of SQUID Electronics

We report commercially available computer-controlled SQUID electronics are usually delivered with software providing a basic user interface for adjustment of SQUID tuning parameters, such as bias current, flux offset, and feedback loop settings. However, in a research context it would often be useful to be able to modify this code and/or to have full control over all these parameters from researcher-written software. In the case of the STAR Cryoelectronics PCI/PFL family of SQUID control electronics, the supplied software contains modules for automatic tuning and noise characterization, but does not provide an interface for user code. On the other hand, the Magnicon SQUIDViewer software package includes a public application programming interface (API), but lacks auto-tuning and noise characterization features. To overcome these and other limitations, we are developing an "open-source" framework for controlling SQUID electronics which should provide maximal interoperability with user software, a unified user interface for electronics from different manufacturers, and a flexible platform for the rapid development of customized SQUID auto-tuning and other advanced features. Finally, we have completed a first implementation for the STAR Cryoelectronics hardware and have made the source code for this ongoing project available to the research community on SourceForge (http://opensquid.sourceforge.net) under the GNU public license.

47 OTHER INSTRUMENTATION↗

SQUIDs De-fluxing Using a Decaying AC Magnetic Field

Flux trapping is the Achilles’ heel of all superconductor electronics. The most direct way to avoid flux trapping is a prevention of superconductor circuits from exposure to magnetic fields. Unfortunately this is not feasible if the circuits must be exposed to a strong DC magnetic field even for a short period of time. For example, such unavoidable exposures take place in superparamagnetic relaxation measurements (SPMR) and ultra-low field magnetic resonance imaging (ULF MRI) using unshielded thin-film SQUID-based gradiometers. Unshielded SQUIDs stop working after being exposed to DC magnetic fields of only a few Gauss in strength. In this paper we present experimental results with de-fluxing of planar thin-film LTS SQUID-based gradiometers using a strong decaying AC magnetic field. We used four commercial G136 gradiometers for SPMR measurements with up to a 10 mT magnetizing field. Strong 12.9 kHz decaying magnetic field pulses reliably return SQUIDs to normal operation 50 ms after zeroing the DC magnetizing field. This new AC de-fluxing method was also successfully tested with seven other different types of LTS SQUID sensors and has been shown to dissipate extremely low energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗