Search NASA⌕ Search

SEARCH · Search NASA

Results for “stability assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Robust Power System Stability Assessment Against Adversarial Machine Learning-Based Cyberattacks via Online Purification

The increasing complexity associated with renewable generation brings more challenges to power system stability assessment (SA). Data-driven approaches based on machine learning (ML) techniques for stability assessment have received significant research interest and shown their promising performance. However, ML-based models are recognized to be vulnerable to adversarial disturbances, where a slight perturbation to power system measurements could lead to unacceptable errors. To address this issue, this paper develops a novel lightweight mitigation strategy, i.e., robust online stability assessment (ROSA), to enhance the ML-based assessment model against both white-box and the black-box adversarial disturbances (i.e., purification) in the online implementation. The ROSA involves a supervised learning-based module for the primary stability assessment and a self-supervised learning-based module. Further, the two modules are trained jointly with different objective (loss) functions and implemented in sequence. A suitable purification objective and various time-series data augmentation methods are designed for SA applications to tackle adversarial disturbances adaptively. Case studies are performed, and the comparative results have clearly illustrated the competitive, robust accuracy against various adversarial scenarios and verified the effectiveness of the proposed online purification strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Learning Based Frequency Stability Assessment in Power Grid with High Renewables

Frequency stability assessment is one critical aspect of power system security assessment. Traditional N-1 screening method is based on the simulations of a few typical daily and seasonal operation scenarios. However, the increasing integration of inverter-based renewables and the retirement of conventional synchronous generators result in decreasing system inertia and growing complexity of system operating conditions. Selecting a few typical operation scenarios cannot cover all operating conditions, and the time-domain simulation of all operation conditions requires tremendous time. This paper proposes a more efficient frequency stability assessment method based on deep learning. The affinity propagation clustering algorithm is used to divide the dataset into different clusters, so the selected dataset for training can cover the diversified operating conditions as much as possible. Also, feature normalization is applied to both the training dataset and testing dataset in order to remove any unnecessary bias. Especially, trained model based on full dataset normalization has bounded error in the prediction. The case study on the reduced 240-bus WECC system demonstrates that the proposed method can predict accurate frequency nadir with limited training dataset. The deep learning model using the revised feature normalization can predict more accurate frequency nadir than that using the traditional feature normalization and has very small maximum prediction error.

affinity propagation↗

AI-Based Faster-Than-Real-Time Stability Assessment of Large Power Systems with Applications on WECC System

Achieving clean energy goals will require significant advances in regard to addressing the computational needs for next-generation renewable-dominated power grids. One critical obstacle that lies in the way of transitioning today’s power grid to a renewable-dominated power grid is the lack of a faster-than-real-time stability assessment technology for operating a fast-changing power grid. This paper proposes an artificial intelligence (AI) -based method that predicts the system’s stability margin information (e.g., the frequency nadir in the frequency stability assessment and the critical clearing time (CCT) value in the transient stability assessment) directly from the system operating conditions without performing the conventional time-consuming time-domain simulations over detailed dynamic models. Since the AI method shifts the majority of the computational burden to offline training, the online evaluation is extremely fast. This paper has tested the AI-based stability assessment method using multiple dispatch cases that are converted and tuned from actual dispatch cases of the Western Electricity Coordinating Council (WECC) system model with more than 20,000 buses. The results show that the AI-based method could accurately predict the stability margin of such a large power system in less than 0.2 milliseconds using the offline-trained AI agent. Therefore, the proposed method has great potential to achieve faster-than-real-time stability assessment for practical large power systems while preserving sufficient accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ML-Based Power System Stability Assessment Considering Network Topology Changes: WECC 20,000+ Bus System Case Study

Modern power grids are fast-changing and thus require real-time monitoring and online stability assessment. With the rapid development of machine learning (ML) techniques, using data-driven models to provide fast and accurate estimations of power system stability marginal information, such as frequency nadir for frequency stability and critical clearing time (CCT) for transient stability, have become possible. However, despite the numerous research on ML-based methods for frequency nadir and CCT prediction, there is limited work on the impact of different network topology changes. Furthermore, most previous studies only focused on small or synthetic systems, and there is a lack of research on actual large power system models. In this paper, the above issues are addressed by studying the actual U.S. Western Electricity Coordinating Council (WECC) system model with more than 20,000 buses. Massive simulations are conducted in PowerWorld Simulator to study the impact of various topology change scenarios on both frequency stability and transient stability. System operating information is extracted from the success dispatch cases of various network topologies to generate a comprehensive dataset for ML-based models. Two ML methods, random forest (RF) and multilayer perceptron (MLP) neural network, are trained and tested for both frequency nadir prediction and CCT prediction. Test results have proven the models are capable of online stability assessment for large power networks such as the WECC system with sufficient accuracy.

critical clearing time↗

Avoidance of disruptions on KSTAR due to vertical displacement events via novel real-time stability assessment

Disruption avoidance via the DECAF approach has been achieved on KSTAR using a novel real-time vertical stability assessment and a multiactuator feedback control strategy. The development of disruption avoidance strategies with reactor-relevant reliability is an urgent activity, enabling future fusion power plants. The stability metric employed is based on a new formulation of a vertical force gradient balance metric evaluated across the poloidal cross section of the plasma, with parameters tuned using historical data. Evaluation of this metric on a validation set of 400 recent KSTAR shots indicates >82% of Vertical displacement events can be avoided via feedback control. Essential to its calculation is the two-dimensional toroidal current density distribution in the plasma. Measurement of this profile faster than fully-converged equilibrium reconstructions can deliver is found to improve forecaster performance and is achieved with a surrogate model that takes as input magnetic diagnostic measurements and outputs the current profile on a basis comprising the top principal components of historical current profiles (from past equilibrium reconstructions). This method solves the non-uniqueness problem typically faced when reconstructing current profiles directly from diagnostics, while improving computational time and accuracy. On average, profiles produced by this model reach coefficients of determination of >0.99 with respect to those from equilibrium reconstructions. The avoidance actuators employed include poloidal field coils and an electron cyclotron current drive system. The multiactuator approach, as shown in this first demonstration, allows disruption avoidance while minimizing impact to operational performance. This ability, along with its flexibility and speed, makes this new approach an attractive option for avoiding these types of disruptions in reactors.

Tobin, Matthew [Columbia Univ., New York, NY (Unit↗

Explainable Bayesian Neural Network for Probabilistic Transient Stability Analysis Considering Wind Energy

While several data-driven models have been developed for transient stability assessment, how to consider the uncertainties from load and renewable generations and provide interpretation of data-driven assessment results are still open. This paper proposes an explainable Bayesian Neural Network (BNN) for probabilistic transient stability assessment (TSA). By extracting the uncertainties from loads and wind farms, the BNN model can make a reliable prediction and quantify the prediction uncertainties. We also develop the Gradient Shap algorithm to make the global and local explanations for the probabilistic TSA model, a significant advantage over existing black-box data-driven methods. Numerical results on the modified IEEE 39-bus system show that the proposed method outperforms the existing methods in terms of prediction accuracy and uncertainty quantification capabilities. The explainability of the proposed method allows system operators to design preventive controls for enhancing system stability.

Bayesian Neural Network↗

Common Electric Power Transmission System Model JSON Schema Specification

The Common Electric Power Transmission System Model (CTM) is an intuitive, extensible, language-agnostic, and error-resistant specification of electric power network components parameter names and units, and relation between components, intended for use by the research community developing new computational methods for power systems operations and simulation. Power system datasets following the CTM specification can be read as dictionaries and manipulated in that form in most programming languages (e.g., Python, Julia, C++). This standard data structure in CTM makes it easy to work in multiple power systems domains (e.g., economic operation, reliability assessment, electricity markets, stability assessment, etc.) without requiring conversions between use-case-specific file formats with information loss in the process. This repository specifies CTM as a JSON Schema, provides documentation, derivate (code-generated) implementations of CTM, and example data and usage of the schema for important use cases.

Aravena Solis, Ignacio↗

Extended real-time voltage instability identification method based on synchronized phasor measurements

This paper presents an extended adaptive approach designed to accurately estimate the Thévenin equivalent parameters using phasor measurements at a given bus for measurements lying in any of four quadrants of the PQ-plane. The improvement is achieved by using a new condition to properly update the estimated parameters after an initial guess. Based on an adaptive philosophy, the proposed approach can correctly account for the intrinsic nonlinearities of a power system, can provide a real-time estimation of Thévenin parameters, and does not require network topology knowledge. The method is validated using the Kundur 2-area system, showing estimation improvements compared to the current adaptive approach and the classical recursive least-squares method. The proposed approach is able to estimate both sides of the system with respect to the measurement bus. In addition, a data-driven voltage stability index is developed. To illustrate the performance of the proposed approach in a larger power system, a voltage stability assessment is carried out on the IEEE 39-bus system, considering the action of overexcitation limiters of generators and nonlinear loads. The proposed approach is suitable for applications that require an accurate Thévenin equivalent estimation in real-time, such as for voltage stability assessment. The new approach provides a reliable tool for the system operators to make proper and timely decisions.

42 ENGINEERING↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Procedures for Assessing the Stability of Proposed Topological Materials

Here, we investigate the stability of MnPb 2 Bi 2 Te 6 (MPBT), which is predicted to be a magnetic topological insulator (TI), using density functional theory calculations. Our analysis includes various measures such as enthalpies of formation, Helmholtz free energies, defect formation energies, and dynamical stability. Our thermodynamic analysis shows that the phonon contribution to the energy gain from finite temperature is estimated to be less than 10 meV/atom, which may not be sufficient to stabilize MPBT at high temperatures, even with the most favorable reactions starting from binaries. While MPBT is generally robust against the formation of various defects, we find that the anti-site defect formation of MnPb is the most likely to occur, with a corresponding energy less than 60 meV. This can be attributed to the significant energy cost from compressive strain at the PbTe layer. Our findings suggest that MPBT is on the brink of stability in terms of thermodynamics and defect formation, underscoring the importance of conducting systematic analyses of the stability of proposed TIs, including MPBT, for their practical utilization. This study offers valuable insights into the design and synthesis of desirable magnetic TI materials with robust stabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Analytical small-signal stability analysis of low-inertia power system frequency response considering secondary frequency regulation

Modern power systems are increasingly vulnerable to frequency instability as inverter-based resources (IBRs) replace synchronous machines and reduce system rotational inertia. Existing small-signal frequency stability assessment methods are either computationally intensive, relying on simulation-driven approaches, or lack analytical stability regions that explicitly account for secondary frequency response (SFR). This paper introduces new analytical frameworks that enable evaluation small-signal frequency stability while explicitly incorporating tunable IBR and SFR parameters. Using Kharitonov’s theorem with an overbounding approach, explicit small-signal stability criteria are derived. In addition, based on Białas’ criterion and Hurwitz matrix, analytical stability regions are established to reveal feasible design spaces for SFR and IBR parameters tuning. Extensive Matlab/Simulink-based simulations validate the accuracy and computational efficiency of the proposed methods, demonstrating that coordinated tuning of SFR and IBR parameters can substantially enhance system resilience. By bridging analytical rigor with practical tunability, this work provides an analytical framework for assessing small-signal frequency stability in low-inertia grids, supporting the real-time, scalable, and resilient operation of sustainable power systems.

14 SOLAR ENERGY↗

Physics basis for the reference flat-top plasma scenario in the ST–E1 fusion power plant

As part of the U.S. Department of Energy’s Milestone-Based Fusion Energy Development Program, Tokamak Energy has completed the pre-concept design of the ST–E1 fusion power plant. ST–E1 is envisaged to operate in two phases: a pilot plant phase, targeting sustained net power production of 300 - 500 MWe for a duration >1 hr, followed by a commercial power plant phase targeting steady-state operations and a normalised overnight capital cost of ⩽12 000 $\$$/kWe. The design process adopted was highly iterative, integrating all major plant systems and progressing in a phased fidelity approach. At the pre-conceptual stage, the emphasis has been on exploring the design space, identifying the main system-level trade-offs, and making the key decisions that define the overall plant concept, rather than optimising a single operating point. This paper, part of a focused collection detailing the ST–E1 pre-concept design, addresses the development of a series of reference flat-top plasma operating points for the pilot plant phase. A modelling workflow was established to develop and assess candidate plasma design points and explore key dependencies. The workflow includes integrated core plasma modelling, magnetohydrodynamic (MHD) stability assessment, equilibrium generation, scrape-off-layer and exhaust modelling, heating & current drive design and optimisation, and turbulent transport modelling. Using this framework, the impact of several key parameters on the flat-top operating space was investigated, including the density limit, core radiation fraction and divertor power loading, level of external heating and curent drive power and assumed pedestal characteristics. The MHD stability, controllability and micro-stability characteristics of these plasmas were also analysed. These investigations informed the definition of a set of fully non-inductive, flat-top reference operating points that satisfy the high-level ST–E1 mission, including a low and high density case, a case that is stable to resistive wall modes and a case with reduced divertor power loading.

ST–E1↗

Deep Sigma Point Processes-Assisted Chance-Constrained Power System Transient Stability Preventive Control

Here this paper proposes a deep sigma point processes (DSPP)-assisted chance-constrained power system transient stability preventive control method to deal with uncertain renewable energy and loads-induced stability risk. The traditional transient stability-constrained preventive control is reformulated as a chance-constrained optimization problem. To deal with the computational bottleneck of the time-domain simulation-based probabilistic transient stability assessment, the DSPP is developed. DSPP is a parametric Bayesian approach that allows us to predict system transient stability with high computational efficiency while accurately quantifying the confidence intervals of the predictions that can be used to inform system instability risk. To this end, with a given preset confidence probability, we embed DSPP into the primal dual interior point method to help solve the chance-constrained preventive control problem, where the corresponding Jacobian and Hessian matrices are derived. Comparison results with other existing methods show that the proposed method can significantly speed up preventive control while maintaining high accuracy and convergence