Search NASASearch

SEARCH · Search NASA

Results for “stack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design and assembly considerations for Redox cells and stacks

Individual redox flow cells are arranged electrically in series and hydraulically in parallel to form a single assembly called a stack. The hardware currently being tested in the laboratory has an active electrode area of either 310 sq cm or 929 sq cm. Four 310 sq cm stacks, each consisting of 39 active cells, were incorporated into a 1.0 kW preprototype system. The physical design of the stack is very critical to the performance and efficiency of the redox storage sytem. This report will discuss the mechanical aspects of the cell and stack design for the current Redox hardware, with regard to sealing the stack internally as well as externally, minimizing shunt currents and minimizing the electrical resistance of the stack.

Stalnaker, D. K.

Exhaust-stack nozzle area and shape for individual cylinder exhaust-gas jet-propulsion system

This report presents the results of an investigation conducted on the effect of exhaust-stack nozzle area, shape, and length on engine power, jet thrust, and gain in net thrust (engine propeller plus jet). Single-cylinder engine data were obtained using three straight stacks 25, 44, and 108 inches in length; an S-shaped stack, a 90 degree bend, a 180 degree bend, and a short straight stack having a closed branch faired into it. Each stack was fitted with nozzles varying in exit area from 0.91 square inch to the unrestricted area of the stack of 4.20 square inches. The engine was generally operated over a range of engine speeds from 1300 to 2100 r.p.m, inlet-manifold pressures from 22 to 30 inches of mercury absolute, and a fuel-air ratio of 0.08. The loss in engine power, the jet thrust, and the gain in net thrust are correlated in terms of several simple parameters. An example is given for determining the optimum nozzle area and the overall net thrust.

Pinkel, Benjamin

The measurement of the stacking fault energy in copper, nickel and copper-nickel alloys

The relationship of hydrogen solubility and the hydrogen embrittlement of high strength, high performance face centered cubic alloys to the stacking fault energy of the alloys was investigated. The stacking fault energy is inversely related to the distance between the two partial dislocations which are formed by the dissociation of a perfect dislocation. The two partial dislocations define a stacking fault in the crystal which offers a region for hydrogen segregation. The distance between the partial dislocations is measured by weak beam, dark field transmission electron microscopy. The stacking fault energy is calculated. Pure copper, pure nickel and copper-nickel single crystals are used to determine the stacking fault energy.

Leighly, H. P., Jr.

Adjustable cutting guide aligns and positions stacks of material

Adjustable guide tool aligns and positions stacks of material for cutting at various angles. The device adapts its shape to stacks of any corner angle, adjusts to any cutting angle, and quickly aligns the stacks for repeated cutting. With this device, an operator need not place his hands under the knife during alignment.

Thiel, A. M.

Calibration of a laboratory spectrophotometer for specular light by means of stacked glass plates.

Stacked glass plates have been used to calibrate a laboratory spectrophotometer, over the spectral range 0.5-2.5 microns, for specular light. The uncalibrated instrument was characterized by systematic errors when used to measure the reflectance and transmittance of stacked glass plates. Calibration included first, a determination of the reflectance of a standard composed of barium sulfate paint deposited on an aluminum plate; second, the approximation of the reflectance and transmittance residuals between observed and computed values by means of cubic equations; and, finally, the removal of the systematic errors by a computer. The instrument, after calibration, was accurate to 1% when used to measure the reflectance and transmittance of stacked glass plates.

Allen, W. A.

Remote fire stack igniter

An igniter is described mounted on a vent stack with an upper, flame cage near the top of the stack to ignite emissions from the stack. The igniter is a tube with a lower, open, flared end having a spark plug near the lower end and a solenoid-controlled valve which supplies propane fuel from a supply tank. Propane from the tank is supplied at the top under control of a second, solenoid-controlled valve. The valve controlling the lower supply is closed after ignition at the flame cage. The igniter is economical, practical, and highly reliable.

Ray, W. L.

Energy Conservation Alternatives Study (ECAS): Conceptual Design and Implementation Assessment of a Utility Steam Plant with Conventional Furnace and Wet Lime Stack Gas Scrubbers

A study was performed to estimate the technical/economic characteristics of a steam power plant (3500 pounds per square inch gauge, 1000 degrees Fahrenheit / 1000 degrees Fahrenheit) with a coal-burning radiant furnace and a wet lime stack gas scrubber to control sulfur emissions. Particulate emissions were controlled by an electrostatic precipitator operating at 300 degrees Fahrenheit. The stack gas from the scrubber was reheated from 125 degrees Fahrenheit to 250 degrees Fahrenheit as a base case, and from 125 degrees Fahrenheit to 175 degrees Fahrenheit as an alternate case. The study was performed on a basis consistent with the General Electric ECAS Phase II evaluation of advanced energy conversion systems for electric utility baseload applications using coal or coal-derived fuels. A conceptual design of the power plant was developed, including the on-site calcination of limestone to lime and the provision of sludge ponds to store the products of flue gas scrubbing. From this design, estimates were derived for power plant efficiency, capital cost, environmental intrusion characteristics, natural resource requirements, and cost of electricity at an assumed capacity factor of 65 percent. An implementation assessment was performed where factors affecting applicability of the conceptual design power plant in electric utility generation systems were appraised. At 250 degrees Fahrenheit and 175 degrees Fahrenheit stack gas temperatures respectively, the plants showed a cost of electricity of 39.8 and 37.0 mills per kilowatt-hours and overall plant efficiencies of 32 percent and 34 percent.

Brown, Dale H.

Comparison of stack plume properties obtained from aircraft and spacecraft measurements

Landsat II imagery data and aircraft nephelometer measurements were analyzed to determine the quantitative properties of a stack plume emitted from a moderate-sized pulpmill. Aircraft measurements were obtained at several heights across the plume at 1.0, 3.0, and 6.5 km downwind from the stack, and for comparative purposes, the Landsat data were also analyzed at these same three locations and at 0.5 and 10.0 km. Overlapping, consecutive-day MSS data provided plume/no-plume radiances upwelling from the stack site. Imagery data from a 10- by 10 km region in the vicinity of the mill were normalized to correct for atmospheric, solar, and viewing angle differences for the 2 observation days, and cloud-shadow data were used to evaluate sky radiance. Particle concentrations, vertical and lateral dispersions, and plume heights determined from both the aircraft and spacecraft measurement techniques are in good agreement.

Staylor, W. F.

Detection of S02 and N02 in Stack Plume by Raman Scattering and Fluorescence

We have been studying laser-Raman radar which can be used as the remote detector of sulfur dioxide concentration in the stack plume of boiler exhaust gas, and some results have been published. In this paper, we report the interference of nitrogen dioxide fluorescence against sulfur dioxide Raman scattering and the measuring method of sulfur dioxide and nitrogen dioxide concentration. In a stack plume, high density dust and high concentration carbon dioxide are included, therefore very strong Mie back-scattering and carbon dioxide Raman scattering are observed. The separation of these scattering signals from sulfur dioxide Raman signal was the first problem for the laser-Raman radar. But, this problem was solved by using the filter which have high resolving power. It is well known that nitrogen dioxide can be excited to emit fluorescence of broad spectrum by blue-green light. The light source of the laser-Raman radar is SH of Nd:YAG laser, and boiler exhaust gas includes several tens ppm of nitrogen dioxide, then the interference of nitrogen dioxide fluorescence brings the error to sulfur dioxide measurement. 'rhe rejection of the interference can be achieved by the subtraction of the nitrogen dioxide fluorescence contribution from detected signal at sulfur dioxide Raman scattering wavelength. The nitrogen dioxide fluorescence contribution can be measured by two methods. The first is to convert the nitrogen dioxide fluorescence intensity which is measured at a different wavelength from sulfur dioxide Raman line into the one at sulfur dioxide Raman line. The second is to convert the detected signal intensity, which is obtained when the range gate is set just behind the plume, into the one obtained at the range of the plume using the difference of the time dependence between sulfur dioxide Raman scattering and nitrogen dioxide fluorescence. Nitrogen dioxide fluorescence has lifetime of about 300nS, while Raman scattering has none. By either of the two methods, the contribution of nitrogen dioxide fluorescence is determined. Then, we can measure the nitrogen dioxide and sulfur dioxide concentration.The minimum detectable concentration and the experimental results of the remote sensing of sulfur dioxide and nitrogen dioxide in stack plume will be discussed in detail.

Nakahara, S.

A four-channel portable solar radiometer for measuring particulate and/or aerosol opacity and concentration of NO2 and SO2 in stack plumes

Solar absorption radiometry has been investigated as a method of measuring stackplume effluents. A simple and inexpensive instrument was constructed for observing the sun at four wavelengths: 800, 600, 400, and 310 nm. Higher wavelength channels measured the effect of the particulates and NO2, and an ultraviolet channel measured the contribution of SO2 to the attenuation. Stack-plume measurements of opacity and concentration of NO2 and SO2 were in basic agreement with in-stack measurements. The major limitation on the use of the radiometer is the requirement for an accessible viewing position which allows the sun-plume-observer relationship to be attained. It was concluded that the solar radiometer offers an inexpensive method for monitoring plume effluents when the viewing position is not restricted.

Exton, R. J.

An ultraviolet video technique for visualization of stack plumes and for measuring sulfur dioxide concentration and effluent velocity

Absorption spectroscopy utilizing a video sensing technique was investigated as a means of visualizing SO2 in power plant stack plumes and for measuring SO2 concentration and effluent velocity in these plumes. The absorption of SO2 is measured in the ultraviolet region by using the sky as a background source. An additional spectral channel is used to correct for particulate scattering encountered in coal fired power plant plumes. The video system also tracks fluctuations in the SO2 concentration which leads to the determination of an eddy convection velocity. Field measurements were performed to show that the eddy convection velocity is proportional to the average in-stack velocity and to empirically determine their relationship. It was concluded that the video absorption technique is an attractive method for remotely determining both SO2 concentration and plume velocity with the same instrument.

Exton, R. J.

Simultaneous stack-gas scrubbing and waste water treatment

Simultaneous treatment of wastewater and S02-laden stack gas make both treatments more efficient and economical. According to results of preliminary tests, solution generated by stack gas scrubbing cycle reduces bacterial content of wastewater. Both processess benefit by sharing concentrations of iron.

Poradek, J. C.

Effect on combined cycle efficiency of stack gas temperature constraints to avoid acid corrosion

To avoid condensation of sulfuric acid in the gas turbine exhaust when burning fuel oils contaning sulfur, the exhaust stack temperature and cold-end heat exchanger surfaces must be kept above the condensation temperature. Raising the exhaust stack temperature, however, results in lower combined cycle efficiency compared to that achievable by a combined cycle burning a sulfur-free fuel. The maximum difference in efficiency between the use of sulfur-free and fuels containing 0.8 percent sulfur is found to be less than one percentage point. The effect of using a ceramic thermal barrier coating (TBC) and a fuel containing sulfur is also evaluated. The combined-cycle efficiency gain using a TBC with a fuel containing sulfur compared to a sulfur-free fuel without TBC is 0.6 to 1.0 percentage points with air-cooled gas turbines and 1.6 to 1.8 percentage points with water-cooled gas turbines.

Nainiger, J. J.

The determination of the stacking fault energy in copper-nickel alloys

Methods for determining the stacking fault energies of a series of nickel-copper alloys to gain an insight into the embrittling effect of hydrogen are evaluated. Plans for employing weak beam dark field electron microscopy to determine stacking fault energies are outlined.

Leighly, H. P., Jr.

NASA Redox cell stack shunt current, pumping power, and cell performance tradeoffs

The NASA Redox energy storage system is under active technology development. The hardware undergoing laboratory testing is either 310 sq. cm. or 929 sq. cm. (0.33 sq. ft. or 1.0 sq. ft. per cell active area with up to 40 individual cells connected to make up a modular cell stack. This size of hardware allows rather accurate projections to be made of the shunt power/pump power tradeoffs. The modeling studies that were completed on the system concept are reviewed along with the approach of mapping the performance of Redox cells over a wide range of flow rates and depths of discharge of the Redox solutions. Methods are outlined for estimating the pumping and shunt current losses for any type of cell and stack combination. These methods are applicable to a variety of pumping options that are present with Redox systems. The results show that a fully developed Redox system has acceptable parasitic losses when using a fixed flow rate adequate to meet the worst conditions of current density and depth of discharge. These losses are reduced by about 65 percent if variable flow schedules are used. The exact value of the overall parasitics will depend on the specific system requirements of current density, voltage limits, charge, discharge time, etc.

Hagedorn, N.

Stacking faults in TiC.

Stacking faults in titanium carbide shown by electron microscopy bounded by partial dislocations

TITANIUM CARBIDE