At least 19 records

A redundant regulator control with low standby losses

Shunt regulator circuit for outer-planet-spacecraft radiosotope thermoelectric generator minimizes power-conditioning losses. Unit consists of bank of duplicate regulator control amplifiers and their associated shunt transistors connecter across power supply line. Its high-gain circuitry arranged in redundant configuration in very reliable and is characterized by low standby loss. Circuit can be used on other power-supply applications where size, weight, and reliability are important.

Andryczyk, R. W.↗

Dampers for Natural Draft Heaters: Technical Report

Energy required for water heating accounts for approximately 40percent of national residential natural gas consumption in California. With water heating contributing such a substantial portion of natural gas consumption, it is important to pay attention to water heater efficiencies. This paper reports on an investigation of a patented, buoyancy-operated flue damper. It is an add-on design to a standard atmospherically vented natural-draft gas-fired storage water heater. The flue damper was expected to reduce off-cycle standby losses, which would lead to improvements in the efficiency of the water heater. The test results showed that the Energy Factor of the baseline water heater was 0.576. The recovery efficiency was 0.768. The standby heat loss coefficient was 10.619 (BTU/hr-oF). After the damper was installed, the test results show an Energy Factor for the baseline water heater of 0.605. The recovery efficiency was 0.786. The standby heat loss coefficient was 9.135 (BTU/hr-oF). The recovery efficiency increased 2.3percent and the standby heat loss coefficient decreased 14percent. When the burner was on, the baseline water heater caused 28.0 CFM of air to flow from the room. During standby, the flow was 12.4 CFM. The addition of the damper reduced the flow when the burner was on to 23.5 CFM. During standby, flow with the damper was reduced to 11.1 CFM. The flue damper reduced off-cycle standby losses, and improved the efficiency of the water heater. The flue damper also improved the recovery efficiency of the water heater by restricting on-cycle air flows through the flue.With or without the flue damper, off-cycle air flow upthe stack is nearly half the air flow rate as when the burner is firing.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Sensorless Coil Detection Scheme based on Dead-Time Effect in Dynamic Wireless Power Transfer Systems

The detection of electric vehicles in dynamic wireless power transfer (DWPT) systems is important to reduce the standby losses and comply with the electromagnetic-field emission guidelines recommended by the International Commission for Non-Ionizing Radiation Protection. This paper discusses a novel sensorless coil detection scheme, which exploits the phenomenon of voltage-polarity reversal/notches caused by the dead-time effect in the full-bridge inverter. The variations in the system impedance and dead-time effects are collectively exploited to detect the receiver coil in the DWPT system. The proposed coil detection scheme is accomplished at low excitation voltage, which reduces the inverter standby losses. The theoretical analysis of the notch occurrence and open-loop simulation results are presented using a DWPT model developed in the piecewise linear electrical circuit simulation software.

Kavimandan, Utkarsh↗

A Development Path to the Efficient and Cost-Effective Bulk Storage of Electrical Energy

Efficient and cost-effective means for storing electrical energy is becoming an increasing need in our electricity-oriented society. For example, for electric utilities an emerging need is for distributed storage systems, that is, energy storage at substations, at solar or wind-power sites, or for load-leveling at the site of major consumers of their electricity. One of the important consequences of distributed storage for the utilities would be the reduction in transmission losses that would result from having a local source of load-leveling power. For applications such as these there are three criteria that must be satisfied by any new system that is developed to meet such needs. These criteria are: (1) high 'turn-around' efficiency, that is, high efficiency of both storing and recovering the stored energy in electrical form, (2) long service life (tens of years), with low maintenance requirements, and, (3) acceptably low capital cost. An additional requirement for these particular applications is that the system should have low enough standby losses to permit operation on a diurnal cycle, that is, storing the energy during a portion of a given day (say during sunlight hours) followed several hours later by its use during night-time hours. One answer to the spectrum of energy storage needs just outlined is the 'electromechanical battery'. The E-M battery, under development for several years at the Laboratory and elsewhere in the world, has the potential to solve the above energy storage problems in a manner superior to the electro-chemical battery in the important attributes of energy recovery efficiency, cycle lifetime, and amortized capital cost. An electromechanical battery is an energy storage module consisting of a high-speed rotor, fabricated from fiber composite, and having an integrally mounted generator/motor. The rotor operates at high speed, in vacuo, inside of a hermetically sealed enclosure, supported by a 'magnetic bearing', that is, a bearing that uses magnetic forces to support the rotor against gravity. Magnetic bearings are a virtual necessity for the E-M battery in order to achieve long service life, and to minimize frictional losses so that the battery does not lose its charge (run down) too rapidly. These considerations mitigate against the use of conventional mechanical bearings in the E-M battery for most applications. The Laboratory has pioneered the development of a new form of magnetic bearing to meet the special requirements of the E-M battery: the 'ambient-temperature passive magnetic bearing'. Simpler, and potentially much less expensive than the existing 'active' magnetic bearings (ones requiring electronic amplifiers and feedback circuits for their operation) development of the ambient-temperature passive magnetic bearing represents a technological breakthrough. Beyond its use in the E-M battery, the ambient-temperature magnetic bearing could have important applications in replacing conventional lubricated mechanical bearings in electrical machinery. Here the gains would be two-fold: reduced frictional losses, leading to higher motor efficiency, and, of equal importance, the elimination of the need for lubricants and for routine replacement of the bearings owing to mechanical wear. Thus an added benefit from a vigorous pursuit of our electromechanical battery concepts could be its impact on many other areas of industry where rotating machinery in need of improved bearings is involved. If perfected, passive magnetic bearings would seem to represent an almost ideal replacement for the mechanical bearings in many types of industrial electrical machinery. Returning to the issued of energy storage, the E-M battery itself has much to contribute in the area of improving the efficiency of stationary energy storage systems. For example, many electrical utilities utilize 'pumped hydro' energy storage systems as a means of improving the utilization of their 'base-load' power plants. That is, electrical energy is stored during off-peak hours for delivery at times of peak usage. These pumped hydro systems employ upper and lower reservoirs, between which water is shuttled to store and recover the energy. Of necessity, pumped hydro storage facilities are located in mountainous areas, usually far, both from the urban centers where power uses are concentrated, and from the sites of the power plants themselves, increasing the transmission line losses that subtract from the useful energy. More importantly, pumped hydro systems themselves only return from 65 to 70 percent of the electrical energy input required to pump the water from the lower reservoir to the upper one. Thus, including the extra transmission losses from distant siting of the facility, of order 40 percent of the input electrical energy is wasted in every cycle of use of the facility.

25 ENERGY STORAGE↗

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards

Water heating is a main consumer of energy in households, especially in temperate and cold climates. In South Africa, where hot water is typically provided by electric resistance storage tank water heaters (geysers), water heating energy consumption exceeds cooking, refrigeration, and lighting to be the most consumptive single electric appliance in the home. A recent analysis for the Department of Trade and Industry (DTI) performed by the authors estimated that standing losses from electric geysers contributed over 1,000 kWh to the annual electricity bill for South African households that used them. In order to reduce this burden, the South African government is currently pursuing a programme of Energy Efficiency Standards and Labelling (EES&L) for electric appliances, including geysers. In addition, Eskom has a history of promoting heat pump water heaters (HPWH) through incentive programs, which can further reduce energy consumption. This paper provides a survey of international electric storage water heater test procedures and efficiency metrics which can serve as a reference for comparison with proposed geyser standards and ratings in South Africa. Additionally it provides a sample of efficiency technologies employed to improve the efficiency of electric storage water heaters, and outlines programs to promote adoption of improved efficiency. Finally, it surveys current programs used to promote HPWH and considers the potential for this technology to address peak demand more effectively than reduction of standby losses alone

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance and Health Test Procedure for Grid Energy Storage Systems

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: round-trip efficiency, standby losses, response time/accuracy, and useable energy/state of charge at different discharge/charge rates over the system's lifetime. The procedures are divided into reference performance tests, which require the system to be put in a test mode and are to be conducted in intervals, and real-time monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modification and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditure. Simulated results based on a detailed system simulation of a prototype system are provided as guideline.

25 ENERGY STORAGE↗

Hierarchical Model-Free Transactional Control of Building Loads to Support Grid Services

A transition from generation on demand to consumption on demand is one of the solutions to overcome the many limitations associated with the higher penetration of renewable energy sources. Such a transition, however, requires a considerable amount of load flexibility in the demand side. Demand response (DR) programs can reveal and utilize this demand flexibility by enabling the participation of a large number of grid-interactive efficient buildings (GEB). Existing approaches on DR require significant modelling or training efforts, are computationally expensive, and do not guarantee the satisfaction of end users. To address the aforementioned limitations, this software code considers a scalable hierarchical model-free transactional control approach that incorporates elements of virtual battery, game theory, and model-free control (MFC) mechanisms. The developed approach separates the control mechanism into upper and lower levels. The MFC modulates the flexible GEB in the lower level with guaranteed thermal comfort of end users in response to the optimal pricing and power signals determined in the upper layer using a Stackelberg game integrated with aggregate virtual battery constraints. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable even on small, embedded devices. This software code enables the use of residential and small-size commercial buildings to offer a potentially substantial source of ancillary grid services that are currently underutilized. A hierarchical, model-free transactive building control provides a smooth interface between the grid service requests of utilities and the reliable control required by participating buildings. Model-free control, which supports distributed control architecture, will be a more scalable solution that can be deployed in neighborhood-size systems as well as individual buildings. The proposed approach contributes to the body of knowledge on two main aspects. First, it couples the MFC with the game-theoretic control and proposes a scalable model-free transactive control approach. MFC does not require any modeling effort or model training for the various building loads. This is very beneficial since deriving an accurate model for every single unit participating in DR programs and obtaining all the parameters about the units (e.g., thermal coefficients, standby losses) are infeasible. Also, MFC is computationally efficient, easily deployable even on small, embedded devices, and can be implemented in real time. Second, it integrates the concept of virtual battery into DR via the Stackelberg game. The concept of virtual battery enables efficient coordination and aggregation of a large number of flexible GEB with guaranteed thermal comfort of end users.

Olama, Mohammed [Oak Ridge National Lab. (ORNL), O↗

Development of an Accurate Feed-Forward Temperature Control Tankless Water Heater

The following document is the final report for DE-FC26-05NT42327: Development of an Accurate Feed-Forward Temperature Control Tankless Water Heater. This work was carried out under a cooperative agreement from the Department of Energy's National Energy Technology Laboratory, with additional funding from Keltech, Inc. The objective of the project was to improve the temperature control performance of an electric tankless water heater (TWH). The reason for doing this is to minimize or eliminate one of the barriers to wider adoption of the TWH. TWH use less energy than typical (storage) water heaters because of the elimination of standby losses, so wider adoption will lead to reduced energy consumption. The project was carried out by Building Solutions, Inc. (BSI), a small business based in Omaha, Nebraska. BSI partnered with Keltech, Inc., a manufacturer of electric tankless water heaters based in Delton, Michigan. Additional work was carried out by the University of Nebraska and Mike Coward. A background study revealed several advantages and disadvantages to TWH. Besides using less energy than storage heaters, TWH provide an endless supply of hot water, have a longer life, use less floor space, can be used at point-of-use, and are suitable as boosters to enable alternative water heating technologies, such as solar or heat-pump water heaters. Their disadvantages are their higher cost, large instantaneous power requirement, and poor temperature control. A test method was developed to quantify performance under a representative range of disturbances to flow rate and inlet temperature. A device capable of conducting this test was designed and built. Some heaters currently on the market were tested, and were found to perform quite poorly. A new controller was designed using model predictive control (MPC). This control method required an accurate dynamic model to be created and required significant tuning to the controller before good control was achieved. The MPC design was then implemented on a prototype heater that was being developed simultaneously with the controller development. (The prototype's geometry and components are based on a currently marketed heater, but several improvements have been made.) The MPC's temperature control performance was a vast improvement over the existing controller. With a benchmark for superior control performance established, five additional control methods were tested. One problem with MPC control is that it was found to be extremely difficult to implement in a TWH, so that it is unlikely to be widely adopted by manufacturers. Therefore the five additional control methods were selected based on their simplicity; each could be implemented by a typical manufacturer. It was found that one of these methods performed as well as MPC, or even better under many circumstances. This method uses a Feedback-Compensated Feed-Forward algorithm that was developed for this project. Due to its simplicity and excellent performance this method was selected as the controller of choice. A final higher-capacity prototype heater that uses Feedback-Compensated Feed-Forward control was constructed. This prototype has many improvements over the currently marketed heaters: (1) excellent control; (2) a modular design that allows for different capacity heaters to be built easily; (3) built-in fault detection and diagnosis; (4) a secondary remote user-interface; and (5) a TRIAC switching algorithm that will minimize 'flicker factor'. The design and engineering of this prototype unit will allow it to be built without an increase in cost, compared with the currently marketed heater. A design rendering of the new product is shown below. It will be launched with a new marketing campaign by Keltech in early 2009.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar hot water system installed at Day's Inn Motel, Dallas, Texas (Valley View)

The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.

Source record↗

Solar hot water system installed at Days Inn Motel, Jacksonville, Florida

The solar system was designed to provide 65 percent of the hot water demand. Water in the liquid flat plate collector (900 square feet) system automatically drains into the 1000 gallon lined and vented steel storage tank when the pump is not running. Heat is transferred from storage to Domestic Hot Water (DHW) tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up DHW standby losses. All pumps are controlled by differential temperature.

Source record↗

Solar hot water system installed at Days Inn Motel, Dallas, Texas (Forrest Lane)

The solar system was designed to provide 65 percent of the total Domestic Hot Water (DHW) demand. The liquid flat plate (water) collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank located in the mechanical room when the pump is not running. Heat is transferred from the storage tank to DHW tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and the heat exchanger enables solar heated water to help make DHW tank standby losses. All pumps are controlled by differential temperature.

Source record↗

Performance and Health Test Procedure for Grid Energy Storage Systems: Preprint

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: Round-trip efficiency, Standby losses, Response time/accuracy, and Useable Energy/ State of Charge at different discharge/charge rates over the system's lifetime. The procedures are divided into Reference Performance Tests, which require the system to be put in a test mode and are to be conducted in intervals, and Real-time Monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.

25 ENERGY STORAGE↗

Adaptive Time-Division Multiplexing Driving System for Solid State Lighting with Multiple Tunable Channels

Next generation solid state lighting enables unlimited control of light and serve much broader functions beyond the basic lighting for illuminance. The emerging lighting for productivity, well-being, healthcare, and growth have revolutionized the scope of lighting. To empower this unlimited controllability, a multi-channel tunable power-electronics driver is essential but has not been satisfactorily addressed so far. Existing solutions are lossy, large, and expensive, due to introduction of additional buck power conversion stages. This paper proposes a time-division multiplexing (TDM) LED driving system which eliminates those buck stages. The proposed design can directly pair with off-the-shelf pulse width modulated (PWM) controllers and since it inherits entire feature sets, it can achieve low loss at standby and at dimmed condition. The simple analog implementation avoids usage of expensive DSPs/MCU. GaN’s high switching frequency capability can push up the multiplexing frequency so a GaN-based flyback was built and proved the concept.

Xue, Lincoln↗

Optimizing Hydronic System Performance in Residential Applications

Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US. When operating properly, the combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater is a viable option for high-efficiency residential space heating in cold climates. Based on previous research efforts, however, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency. Furthermore, guidance on proper design and commissioning for heating contractors and energy consultants is hard to find and is not comprehensive. Through modeling and monitoring, CARB sought to determine the optimal combination(s) of components - pumps, high efficiency heat sources, plumbing configurations and controls - that result in the highest overall efficiency for a hydronic system when baseboard convectors are used as the heat emitter. The impact of variable-speed pumps on energy use and system performance was also investigated along with the effects of various control strategies and the introduction of thermal mass.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York (Fact Sheet)

Condensing boiler technology has been around for many years and has proven to be a durable, reliable method of heating. Based on previous research efforts, however, it is apparent that these types of systems are not designed and installed to achieve maximum efficiency. For example, in order to protect their equipment in the field, manufacturers of low-mass condensing boilers typically recommend design strategies and components that ensure steady, high flow rates through the heat exchangers, such as primary-secondary piping, which ultimately result in decreased efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Domestic Hot Water Temperature Maintenance Technology Review

Domestic hot water temperature maintenance (HWTM) is an important topic in facility management, and there are often opportunities to optimize systems to achieve energy, water, and maintenance savings. The main purpose of an HWTM system is to provide reliable hot water temperature at all fixtures with minimal wait time. This is done by replacing the standby heat losses from hot water sitting idle in pipes during periods of low demand. Traditionally, most commercial buildings do this by having water recirculate back to the water heater to be reheated. Other currently available HWTM systems are also discussed in this resource. HWTM systems can help maintain water at appropriate temperatures, minimize heat loss, and minimize delivery times to fixtures to improve the function of a building. This webpage includes a summary of HWTM options along with important considerations regarding occupant safety and comfort, and maintenance strategies for optimal and efficient operations. Domestic hot water (DHW) generation systems are referred to but are not the focus of this resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Hydronic System Performance in Residential Applications

Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US.

AFUE↗

Technology Solutions Case Study: Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York

Condensing boiler technology has been around for many years and has proven to be a durable, reliable method of heating. Based on previous research efforts, however, it is apparent that these types of systems are not designed and installed to achieve maximum efficiency. For example, in order to protect their equipment in the field, manufacturers of low-mass condensing boilers typically recommend design strategies and components that ensure steady, high flow rates through the heat exchangers, such as primary-secondary piping, which ultimately result in decreased efficiency. There is also a significant lack of information for contractors on how to configure these systems to optimize overall efficiency. In response to these findings, researchers from Building America team Consortium for Advanced Residential Buildings worked with industry partners to develop hydronic system designs that would address these issues and result in higher overall system efficiencies and improved response times.

AFUE↗