Search NASA⌕ Search

SEARCH · Search NASA

Results for “stationary batteries”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A framework for integrating supply chain, environmental, and social justice factors during early stationary battery research

The transition to a decarbonized economy will drive dramatically higher demand for energy storage, along with technological diversification. To avoid mistakes of the past, the supply chain implications and environmental and social justice (ESJ) impacts of new battery technologies should be considered early during technological development. We propose herein a systematic framework for analyzing these impacts for new stationary battery technologies and illustrate the framework with a case study. The goal is to promote future development of technologies with secure supply chains and favorable ESJ profiles to avoid expensive corrective actions after substantial resources have been invested. This framework should be a useful tool for public and private researchers and sponsors who want to ensure that supply chain and ESJ concerns are considered and integrated as part of decision making throughout the research and development process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low-Cost All-Temperature Zinc-Pulp Battery for Stationary Storage

WH-Power Final Technical Report — Low-Cost All-Temperature Zinc-Pulp Battery This is the final scientific/technical report for ARPA-E CREATE program award DE-AR0001796, covering work from September 2023 through September 2025. The WHP–UMD–Yale team set out to develop a safe, low-cost, wide-temperature zinc battery for grid-scale stationary storage. What was built: A zinc-pulp (Zn/CNF) battery system pairing an aqueous high-entropy electrolyte (HEE) with a cellulose-derived ion-conducting membrane.

25 ENERGY STORAGE↗

Development of High Performance and Sustainable Na-ion Batteries for Stationary Electrical Energy Storage

This report describes the status of advanced sodium-ion battery research being performed at Pacific Northwest National Laboratory for the U.S. Department of Energy’s Energy Storage Systems Program. The program will demonstrate a novel sodium-ion battery pouch cell with at least 50 mAh capacity capable of achieving $100/kWh projected materials cost at an energy retention > 80% over 250 cycles.

25 ENERGY STORAGE↗

Battery Control Using Stochastic Model Predictive Control

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-of-Use and Demand Charge Battery Controller Using Stochastic Model Predictive Control

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-of-Use and Demand Charge Battery Controller Using Stochastic Model Predictive Control: Preprint

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Levelized cost of charging of extreme fast charging with stationary LMO/LTO batteries

Extreme DC fast charging for electric vehicles (EVs) could be competitive with the internal combustion engine refueling experience and enable longer-distance travel, which could help with EV adoption and decarbonization, but these systems have high capital costs and extremely variable high-power demands. Behind-the-meter systems (BTMS) could support extreme-fast-charging (XFC) stations to increase nationwide adoption of EVs. Here, this study examines the optimal break-even levelized cost of charging (LCOC) across 96 BTMS scenarios to enable low-wait XFC stations providing 200 miles of charge in 10 min. This research simulates LCOC via synthetic XFC-capable EV loads, machine-learned battery life models from testing data, and nonlinear optimal controls, co-minimizing complex utility costs and battery replacements. An aggregate optimal BTMS design treating each EV load as equal likely gives an optimal LCOC per utility rate, the average of which is $\$$0.59/kWh. In addition, the sensitivity of optimal and off-optimal design factors, the long-life LMO/LTO chemistry, and optimized controls are analyzed. The battery control model, based on battery stressors to compare chemistries, optimizes LMO/LTO resting state of charge and cycle depth without compromising cost reduction, which enables greater flexibility in operation. The LCOC savings due to replacement reduction are small, up to $\$$0.035/kWh (6%), with an average of $\$$0.02/kWh (3.5%). Compared with gasoline stations, the aggregate XFC station design achieves comparable speed, experience of service, and cost at $\$$3.81/gal gasoline, showing that EVs can replace gasoline vehicles even for longer-distance travel.

25 ENERGY STORAGE↗

A control oriented comprehensive degradation model for battery energy storage system life prediction

In order to ensure that stationary battery energy storage systems (BESSs) provide reliable energy buffering, both for power quality and economic purposes, the degradation must be considered. Cell degradation involves various side reactions and is highly dependent on its operating conditions. To accurately track cell degradation and predict its impact on battery behavior, a comprehensive physics-based degradation model based on an electrolyte phase-enhanced single particle (SP) model is developed. Key degradation physics, namely solid electrolyte interphase (SEI) layer formation and growth, Li plating on the graphite anode, and Mn dissolution on cathode of nickel-cobalt-manganese oxide (NMC622) are considered. The model is validated against experimental capacity data. The results reveal that the deposition rate of both SEI layer and Li metal increase as the charge voltage increases. At the cathode side, the solvent oxidation rate determines the Mn dissolution rate. As a result, the volume fraction of NMC622 in the cathode continually decreases at a gradually increasing rate.

25 ENERGY STORAGE↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

Improving the Power Outage Resilience of Buildings with Solar PV through the Use of Battery Systems and EV Energy Storage

Buildings with solar photovoltaic (PV) generation and a stationary battery energy storage system (BESS) may self-sustain an uninterrupted full-level electricity supply during power outages. The duration of off-grid operation is dependent on the time of the power fault and the capabilities of the home energy management system (HEMS). In this paper, building resilience is quantified by analyzing the self-sustainment duration for all possible power outages throughout an entire year. An evaluation method is proposed and exercised on a reference house in California climate zone 9 for which the detailed electricity usage is simulated using the EnergyPlus software. The influence of factors such as energy use behavioral patterns, energy storage capacity from the BESS, and an electric vehicle (EV) battery on the building resilience is evaluated. Varying combinations of energy storage and controllable loads are studied for optimally improved resilience based on user preferences. It is shown that for the target home and region with a solar PV system of 7.2 kW, a BESS with a capacity of 11 kWh, and an EV with a battery of 80 kWh permanently connected to the home, off-grid self-sustained full operation is guaranteed for at least 72 h.

14 SOLAR ENERGY↗

Multiscale model predictive control of battery systems for frequency regulation markets using physics-based models

In this work, we propose a multiscale model predictive control (MPC) framework for stationary battery systems that exploits high-fidelity models to trade-off short-term economic incentives provided by energy and frequency regulation (FR) markets and long-term degradation effects. We find that the MPC framework can drastically reduce long-term degradation while properly responding to FR and energy market signals (compared to MPC formulations that use low-fidelity models). Our results also provide evidence that sophisticated battery models can be embedded within closed-loop MPC simulations by using modern nonlinear programming solvers (we provide an efficient and easy-to-use implementation in Julia). We use insights obtained with our simulations to design a low-complexity MPC formulation that matches the behavior obtained with high-fidelity models. This is done by designing a suitable terminal penalty term that implicitly captures long-term degradation. The results suggest that complex degradation behavior can be accounted for in low-complexity MPC formulations by properly designing the cost function. We believe that our proof-of-concept results can be of industrial relevance, as battery vendors are seeking to participate in fast-changing electricity markets while maintaining asset integrity.

42 ENGINEERING↗

U.S. Federal Policy Considerations for the Management of Retired Large-Format Batteries

The global demand for large-format batteries used in electric vehicles (EV) and battery energy storage is expected to continue as governments call for zero emission policies. Total installed large-scale stationary battery energy storage is expected to increase almost 20-fold in the coming years - from 17 GW installed globally in 2020 to 358 GW projected in 2030. Similarly, light duty EVs sales globally are expected to increase more than 8-fold from 2020 to 2030 - from 3 million units to 25 million units. The expected demand for large-format batteries brings supply chain concerns, and economic opportunities. Domestic reuse and recycling is one potential circular economy solution for large-format batteries. This presentation discusses current U.S. law and regulatory landscape for the reuse and recycling of large-format batteries, and how certain policy frameworks impact reuse and end-of-life management decisions for large-format battery materials.

battery↗

Application of Mobile Energy Storage for Enhancing Power Grid Resilience: A Review

Natural disasters can lead to large-scale power outages, affecting critical infrastructure and causing social and economic damages. These events are exacerbated by climate change, which increases their frequency and magnitude. Improving power grid resilience can help mitigate the damages caused by these events. Mobile energy storage systems, classified as truck-mounted or towable battery storage systems, have recently been considered to enhance distribution grid resilience by providing localized support to critical loads during an outage. Compared to stationary batteries and other energy storage systems, their mobility provides operational flexibility to support geographically dispersed loads across an outage area. This paper provides a comprehensive and critical review of academic literature on mobile energy storage for power system resilience enhancement. As mobile energy storage is often coupled with mobile emergency generators or electric buses, those technologies are also considered in the review. Allocation of these resources for power grid resilience enhancement requires modeling of both the transportation system constraints and the power grid operational constraints. These aspects are discussed, along with a discussion on the cost–benefit analysis of mobile energy resources. The paper concludes by presenting research gaps, associated challenges, and potential future directions to address these challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Parallel derivative-free optimization for simulation-based design of behind-the-meter energy systems

In this work, the integrated design and dispatch of behind-the-meter or distributed resources (e.g. stationary battery storage and solar PV generation) is considered. A simulation-based framework is employed, generating high-fidelity results with closed-loop predictive control at a fine resolution, at the expense of high computational cost (several minutes to a few hours per design point). To address this challenge, parallel derivative-free design methods are considered. Four methods are compared, including state-of-the-art surrogate-based methods (Radial-Basis Functions and Gaussian processes) and sampling strategies, an evolutionary-based method, and a simple sequential grid refinement method. As a case study, two types of design problem with increasing complexity are considered, namely, the design of behind-the-meter resources (three design variables) and the inclusion of grid capacity (four design variables). The second yields a constrained design problem for which violations can only be determined after solving the computationally expensive simulation. For the three-dimensional case, all methods present a good performance, achieving a solution within 1% of the optimum after the first iteration, with the sequential grid refinement exhibiting the fastest convergence and achieving the best final objective value. This indicates that the parallel evaluation of multiple sampling points may be more important than the choice of method for small decision spaces. For the four-dimensional constrained case, the Genetic Algorithm presents the best tradeoff between performance and computational effort, while the rough objective function terrain generated by constraint violation penalties reduces the performance of surrogate-based methods. Contour plots with flat regions indicate flexibility in the optimal design and highlight the importance of characterizing the solution space.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage↗

State-Level Employment Projections for Four Clean Energy Technologies in 2025 and 2030

As states and local governments weigh how to spur economic growth, stimulate job creation, and simultaneously adapt to meet climate goals, modern energy codes, and energy demand, this report provides a simple and transparent method to estimate the size of the workforce needed to support modeled deployments for energy efficiency in buildings, stationary battery energy storage (BES), solar photovoltaics (PV), and land-based wind in 2025 and 2030. In addition to a straightforward estimation method, this report includes state-level job estimates for two different deployment scenarios: a business-as-usual scenario and a more accelerated deployment scenario. The scope of the technologies included in this report is limited to four key energy technologies within the power sector that have strong job growth prospects and widespread geographic deployment potential. Although the included technologies are not all-encompassing, they have generated specific interest from state energy offices across the nation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗