Search NASA⌕ Search

SEARCH · Search NASA

Results for “std”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mil-Std-464C and Mil-Std-464D Electromagnetic Radiation Environment Evaluation

Many systems derive their electromagnetic radiation (EMR) environments from Mil-Std-464C or Mil-Std-464D, Electromagnetic Environmental Effects Requirements for Systems. This standard defines several EMR environments based on the type of system and expected application. Many nuclear weapon (NW) systems reference the ordnance environments as the starting point for their functional EMR requirements, since any item intended to go into Department of Defense (DOD) custody is expected to be certified hazards of electromagnetic radiation to ordnance (HERO) safe when exposed to the environments listed in Mil-Std-464 Table 9. This environment is defined as the envelope of all sources any system in DOD custody may ever encounter, however, and may include sources that are not relevant for a particular system. This document is intended to provide additional clarity on the Mil-Std-464C and Mil-Std-464D EMR environments, specifically the driving sources for the maximum ordnance levels. This supplementary information may be used to guide tailoring of relevant environments or application to different systems with the additional consideration of any shielding that may reduce the external environments defined in the military standard.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

DER Inverter Control Fault Ride Through Model in Accordance with IEEE 1547-2018 Std

Distributed Energy Resources (DER) with smart inverters are becoming more prevalent as the need for renewable energy and grid stability increases. An important challenge arises when considering that inverterbased generation methods contribute less current during faults, rendering traditional overcurrent protection unsatisfactory. DERs have fault ride-through requirements when operating in high or low voltage, outlined by IEEE Std. 1547-2018. Faults cause the voltage to reach abnormal steady state magnitudes, depending on the fault resistance and fault type. There are several high voltage and low voltage ride-through zones defined by IEEE Std. 1547-2018. Each zone’s ride through duration decreases as the applicable voltage measurement, i.e., the phase RMS voltage, deviates from its nominal value. This presentation demonstrates the implementation of IEEE Std. 1547-2018 high and low voltage ridethrough grid support functions using a preexisting RSCAD model, discussing the challenges presented during this process. The implemented controls monitor the filtered phase voltages to have a more accurate reading of the applicable voltages. The controls sense the duration that the applicable voltage remains in a specific zone. The breaker trips and ceases energization to the grid when the duration is exceeded. The standard allows the operator to adjust the ride-through times and voltage zones from the default settings. These ranges are implemented into the runtime, which acts as the operator’s SCADA. The results show the accuracy of the voltage measurements, which remain within the IEEE Std. 1547-2018 for all cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources: Preprint

This study addresses the compliance of Inverter-based Resources (IBRs) with the IEEE Std 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a comprehensive controller development framework. This framework caters to maintaining ride-trhough operation or implementing strategic disconnections in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller frame-work is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Technical Basis for Proposed Changes to DOE-STD-1194-2019, Nuclear Material Attractiveness Determination and Categorization

The Department of Energy (DOE)’s Technical Standard DOE-STD-1194-2019 (dated September 2019), Nuclear Materials Control and Accountability, provides key guidance for the determination of Special Nuclear Material (SNM) attractiveness levels. Attractiveness levels are a key component in the security categorization of SNM processed, used, and stored at DOE facilities. Upon review, the writing team identified specific components relating to the determination of attractiveness levels that could be modified to improve clarity, reduce burden on sites, and/or better align with the graded safeguards principle that is central to the DOE’s nuclear security program. The report outlines the original verbiage, issues with implementation of that verbiage, proposed new verbiage, and the expected benefits thus serving as the technical basis for the proposed changes.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Studying the Impact of Momentary Cessation of IBRs Compliant With IEEE Std. 2800-2022 on Transmission Line Protection Elements

This paper examines the impact of inverter-based resource (IBR) momentary cessation timing on transmission system protection relays. IEEE Std. 2800 mandates voltage ride-through, requiring IBRs to remain online during voltage disturbances. However, for severe voltage dips (|V| = 0.1 p.u.), the standard permits current blocking. In practice, vendors implement momentary cessation with varying delays, potentially affecting relay operation if IBRs cease too early. This article studies the impact of the time IBRs enter momentary cessation on transmission line protective relays. Using an electromagnetic transient (EMT) simulation, this study models IBR momentary cessation with tunable delays in a realistic transmission network. COMTRADE files generated from EMT simulations are analyzed in MATLAB using detailed protective relay models. Results indicate that IBRs must sustain operation for at least one cycle to ensure proper relay response; otherwise, relays may fail to oper- ate. These findings guide IBR vendors in optimizing momentary cessation settings to enhance transmission line protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

grid↗

A Generic FSC Wind Park EMT Model with IEEE Std 2800-Compliant Fault Ride-Through Capability

The modern power grid is seeing more and more electricity come from renewable sources like wind farms, which use sophisticated power electronics instead of traditional spinning generators. To keep everything running smoothly and meet industry standards such as IEEE 2800, these systems need smart control strategies. In our work, we built a flexible computer model of a full-scale wind farm converter that can handle grid disturbances without shutting down. When a fault or storm hits, the model’s built-in logic automatically adjusts the currents it sends to the grid and protects its internal energy storage, ensuring the wind farm stays connected and doesn’t damage its own equipment. Once the disturbance clears, the model restores normal operation seamlessly, so there’s no long interruption in power delivery. At the same time, it carefully regulates the voltage where the wind farm ties into the larger grid, helping to maintain safe voltage levels across the network. Our simulations show that this control setup not only meets all the requirements of IEEE Standard 2800 but also allows the wind farm to recover quickly and predictably, keeping the lights on no matter what happens on the grid.

17 WIND ENERGY↗

Transient Stability Study of IEEE 2800-2022 Standard Negative-Sequence-Current Compliant GFM IBRs

The primary function of grid-forming (GFM) inverter-based resources (IBRs) is to maintain voltage and fre- quency/phase angle stability; however, during unbalanced grid faults, IEEE Std. 2800-2022 requires IBRs to inject both positive- and negative-sequence reactive current. Enforcing compliance with this standard could compromise the stability of GFM IBRs under such fault conditions. This paper presents a preliminary transient stability study focused on the power angle stability of GFM IBRs operating in compliance with IEEE Std. 2800 during unbalanced faults. The goal is to assess potential stability issues associated with the standard's current injection requirements under fault ride-through conditions. The results show that injecting positive-sequence current with d-axis priority during unbalanced faults better preserves the power angle stability than the q-axis priority while still enabling negative-sequence current injection. These findings suggest that, to ensure stability, GFM IBRs might need to partially comply with IEEE Std. 2800 by prioritizing positive-sequence current injection along the d-axis.

14 SOLAR ENERGY↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of the Lawrence Livermore Nuclear Accident Dosimeter 1980s-present

A Nuclear Accident Dosimetry program is a federal requirement for all facilities that have the potential to have a criticality accident. Personnel Nuclear Accident Dosimeter (PNAD) theory and analytical procedures are driven by various scientific needs and interacting regulations. A brief history of the status of USA Department of Energy (DOE) nuclear accident dosimetry regulations, recommendations, and performance testing criteria are given. Then, the history of the Lawrence Livermore National Laboratory (LLNL) PNAD is explored, including changes in the physical dosimeter and adjustments of the analysis method through the last four decades. Finally, the performance of LLNL’s PNAD at criticality accident intercomparison training exercises since 2009 is explored. In general, reported neutron doses have been within or close to DOE-STD-1098 performance criteria while reported gamma doses have been outside of DOE-STD-1098 performance criteria. Reported total absorbed doses have varied in meeting ANSI/HPS N13.3 and ANSI/HPS N13.3 (R2019) performance criteria. Dosimetry staff retirement and turnover have left historical knowledge gaps, yet provided opportunities within the NAD program at LLNL. This review paper serves as an overview of the history and status of the NAD program. Brief technical, procedural and programmatic recommendations to improve LLNL’s NAD program are given. Technical recommendations include investigating orientation factors through modeling or empirical experimentation, investigating gamma dosimetry methods for high-dose scenarios, and exploring other dosimetric methods for simpler, quicker NAD analysis. Procedural recommendations include better documentation of conversion factor (activity-to-fluence and fluence-to-dose) derivations and spectrum uses, and updated analysis spreadsheets or simple Graphic User Interfaces for dose calculations. In conclusion, programmatic recommendations include formalized training for NAD analysts, and having multiple SMEs trained on the NAD program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity of the Shallow‐To‐Deep Convective Transition to Moisture and Wind Shear in the Amazon

Deep convection is the primary influence on weather and climate in tropical regions. However, understanding and simulating the shallow‐to‐deep (STD) convective transition has long been challenging. Here, we conduct high‐resolution numerical simulations to assess the environmental controls on the evolution of isolated convection in the Amazon during the wet season. The large‐scale forcing derived through a constrained variational analysis approach for the GoAmazon2014/5 Experiment is used in the simulations. Through sensitivity experiments, we examine the relative importance of moisture and wind shear in controlling the shallow‐to‐deep convective transition for isolated convective events. Convection exhibits the greatest sensitivity to humidity within the lowest 1.5 km, where a 4 mm reduction in column water vapor nearly suppresses ice water formation on deep convective days. In contrast, a reduction in column water vapor in the free troposphere by a factor of two or more is necessary to produce a comparable impact on convection. Increasing low‐level wind speed from 6 to 9 m s -1 enhances afternoon deep convection, raising the cloud ice mixing ratio by approximately 25%. Conversely, upper‐level wind shear reveals the weakest correlation with daytime convection in our simulations. Our results help characterize the role of moisture and wind shear on the STD transition and our understanding of the underlying mechanisms.

environmental controls↗

Bioaccumulation Factor for Radium in Rio Grande Biota

The Los Alamos National Laboratory (LANL or Laboratory) Environmental Protection and Compliance Division’s Environmental Stewardship Group (EPC-ES) performs the radiological analysis portion of biota dose assessments using the computer program RESRAD-Biota (DOE 2004, DOE 2020). RESRAD-Biota uses a default bioaccumulation factor, B iv , for radium in aquatic animals. This bioaccumulation factor, also listed in Department of Energy (DOE) Standard, DOE-STD-1153-2019, is the ratio of a radionuclide concentration in fresh weight biota to the environment in which it resides, which for aquatic animals is water. DOE-STD-1153-2019 offers conservative values for these ratios that are specific to the radiological contaminant, the biota, and the environment. The B iv in RESRAD-Biota can be used for general screening (Level 1 screening). If the factor proves to be too conservative, then a site-specific B iv may be used. The biota dose assessment of fish from the northern New Mexico region of the Rio Grande fail the general screen, which indicates that further analysis is necessary. Level 2 analysis is site-specific but still has conservative limitations. Level 3 analysis is a more realistic and representative, sitespecific analysis. The purpose of this paper is to use data specific to the Rio Grande to calculate a new aquatic animal radium B iv . This B iv can then be used for Level 3 analysis of aquatic animals specifically in the northern New Mexico region of the Rio Grande. The calculated radium B iv is a useful value for performing detailed, accurate biota dose assessments and calculating dose to fish using RESRAD-Biota when only sediment data are available.

54 ENVIRONMENTAL SCIENCES↗

Triple oxygen and hydrogen stable isotope composition of water in Murchison carbonaceous chondrite accessed by thermogravimetry-enabled laser spectroscopy

For this work, we have developed the capability to measure 17 O/ 16 O in H 2 O and OH - of hydrous minerals by a technique using thermogravimetric analysis coupled with isotope ratio infrared spectroscopy (TGA-IRIS) on a suite of liquid water standards, terrestrial mineral standards, multi-mineral synthetic mixtures of terrestrial samples, and Murchison carbonaceous chondrite. This 17 O/ 16 O analytical capability is combined with the previously developed TGA-IRIS capability of 18 O/ 16 O, which enables us to calculate Δ `17 O values. Additionally, we have made 2 H/ 1 H measurements by TGA-IRIS on the suite of materials. Analyses of 328 standard water samples sealed into silver tubes (0.25 μL, 174 VSMOW and 154 GISP) analyzed over the course of three years yielded δ 18 O values by TGA-IRIS with precision of ±0.30 ‰, δ 17 O of ±0.24 ‰, Δ `17 O of ±0.126 ‰, and δ 2 H ± 7.5 ‰ (± 1 Std. Dev.). TGA-IRIS analyses of a suite of hydrous minerals (oxy-hydroxide, mica, serpentines, sulfide, phyllosillicates) yields similar precision. TGA-IRIS analyses of the CM2 carbonaceous chondrite Murchison resulted in δ 18 O, δ 17 O, Δ `17 O, and δ 2 H values of the H 2 O and/or OH - from its hydrous minerals. Δ `17 O values of Murchison H 2 O range from 1.034 ‰ at 350 °C, to -0.368 ‰ at 650 °C, to -1.75 ‰ at 850 °C. TGA-IRIS can generate Δ `17 O values of H 2 O and/or OH - in hydrous materials that are well within the precision needed for the analysis of meteoritic samples, as well as samples returned from asteroids, such as Ryugu and Bennu.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Implementation of McMurchie–Davidson Algorithm for Gaussian AO Integrals Suited for SIMD Processors

We report an implementation of the McMurchie− Davidson evaluation scheme for 1- and 2-particle Gaussian AO integrals designed for processors with Single Instruction Multiple Data (SIMD) instruction sets. Like in our recent MD implementation for graphical processing units (GPUs) [Asadchev, A.; Valeev, E. F.. J. Chem. Phys. 2024, 160, 244109.], variable-sized batches of shellsets of integrals are evaluated at a time. By optimizing for the floating point instruction throughput rather than minimizing the number of operations, this approach achieves up to 50% of the theoretical hardware peak FP64 performance for many common SIMD-equipped platforms (AVX2, AVX512, NEON), which translates to speedups of up to 30 over the state-of-the-art one-shellset-at-a-time implementation of Obara−Saika-type schemes in Libint for a variety of primitive and contracted integrals. As with our previous work, we rely on the standard C++ programming language such as the std::simd standard library feature to be included in the 2026 ISO C++ standard without any explicit code generation to keep the code base small and portable. The implementation is part of the open source LibintX library freely available at https://github.com/ValeevGroup/libintx.

Basis sets↗

Characterization of spent nuclear fuel canister surface roughness using surface replicating molds

In this study we present a replication method to determine surface roughness and to identify surface features when a sample cannot be directly analyzed by conventional techniques. As a demonstration, this method was applied to an unused spent nuclear fuel dry storage canister to determine variation across different surface features. In this study, an initial material down-selection was performed to determine the best molding agent and determined that non-modified Polytek PlatSil23-75 provided the most accurate representation of the surface while providing good usability. Other materials that were considered include Polygel Brush-On 35 polyurethane rubber (with and without Pol-ease 2300 release agent), Polytek PlatSil73-25 silicone rubber (with and without PlatThix thickening agent and Pol-ease 2300 release agent), and Express STD vinylpolysiloxane impression putty. The ability of PlatSil73-25 to create an accurate surface replica was evaluated by creating surface molds of several locations on surface roughness standards representing ISO grade surfaces N 3 , N 5 , N 7 , and N 8 . Overall, the molds were able to accurately reproduce the expected roughness average (R a ) values, but systematically over-estimated the peak-valley maximum roughness (R z ) values. Using a 3D printed sample cell, several locations across the stainless steel spent nuclear fuel canister were sampled to determine the surface roughness. These measurements provided information regarding variability in normal surface roughness across the canister as well as a detailed evaluation on specific surface features (e.g., welds, grind marks, etc.). The results of these measurements can support development of dry storage canister ageing management programs, as surface roughness is an important factor for surface dust deposition and accumulation. This method can be applied more broadly to different surfaces beyond stainless steel to provide rapid, accurate surface replications for analytical evaluation by profilometry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗