Search NASA⌕ Search

SEARCH · Search NASA

Results for “stimulation isolation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Utah FORGE 1-2410: Development of a Smart Completion and Stimulation Solution - Workshop Presentation

This is a presentation on the Development of a Smart Completion & Stimulation Solution project by Welltec in collaboration with the University of Oklahoma, presented by Yosafat Esquitin, a Senior Business Development Manager at Welltec. The project's objective was to develop an annular isolation system, a stimulation isolation system, and a multi-open-close flow system for geothermal environments. These systems were developed to enable effective zonal isolation and stimulation, implement downhole Enhanced Geothermal Systems (EGS) in any location, and extend the productive life of the geothermal well. This presentation was featured in the Utah FORGE R&D Annual Workshop on September 7, 2023. The workshop provided a valuable opportunity to explore the progress made in each of the 17 Research and Development projects funded under Solicitation 2020-1 which aim to enhance our understanding of the crucial factors influencing the development EGS reservoirs and resources.

15 GEOTHERMAL ENERGY↗

Utah FORGE 10-3726: Geothermal Multiset Straddle for High Temperature Applications - 2024 Annual Workshop Presentation

This is a presentation on the Geothermal Multiset Straddle (GMS) for High Temperature Applications by Welltec, presented by Ricardo Vasques. This video slide presentation discusses the development of (1) an annular multiset isolation system; (2) a stimulation straddle isolation system; and (3) a multi open-close flow system, for geothermal environments. This is to enable effective zonal isolation and stimulation with multiset capabilities, to implement downhole controlled EGS in any location, and to extend the productive life of the well. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 15, 2024.

15 GEOTHERMAL ENERGY↗

Utah FORGE 1-2410: Development of a Smart Completion and Stimulation Solution - 2024 Annual Workshop Presentation

This is a presentation on the Development of a Smart Completion & Stimulation Solution by Welltec, presented by Ricardo Vasques. This video slide presentation discusses the development of an (1) annular isolation system, (2) a stimulation isolation system, and (3) a multi open-close flow system for geothermal environments. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 15, 2024.

15 GEOTHERMAL ENERGY↗

Utah FORGE 1-2551: Multi-Stage Fracturing System and Well Tractor to Enable Zonal Isolation During Stimulation and EGS Operations in Horizontal Wellbores - Workshop Presentation and Report

Included here are a presentation recording, slides, and report on the Multi-Stage Fracturing System and Well Tractor to Enable Zonal Isolation During Stimulation and EGS Operations in Horizontal Wellbores project by Colorado School of Mines, presented by Dr. William W. Fleckenstein. One goal of the project is to develop and demonstrate the use of low-cost, rapid multistage fracture stimulation technology with cemented casing frac sleeves that eliminates packers used in both conventional stimulation and injection flow control. The second goal is to develop and demonstrate the devices to effectively detect and control the flow of heat-carrier fluid solely from a long-reach injector through the network of induced and existing fractures and produced from an open-hole long-reach well to improve heat recovery. This presentation was featured in the Utah FORGE R&D Annual Workshop on September 7, 2023. The workshop provided a valuable opportunity to explore the progress made in each of the 17 Research and Development projects funded under Solicitation 2020-1 which aim to enhance our understanding of the crucial factors influencing the development of Enhanced Geothermal Systems (EGS) reservoirs and resources.

15 GEOTHERMAL ENERGY↗

Utah FORGE GeoThermOPTIMAL Video

This is a project description video by Dr. William W. Fleckenstein related to their "Development of Multi-Stage Fracturing System and Wellbore Tractor to Enable Zonal Isolation During Stimulation and EGS Operations in Horizontal Wellbores" R&D project at Utah FORGE which is linked bellow.

15 GEOTHERMAL ENERGY↗

The nature of compensatory and restorative processes in the livers of animals irradiated during hypokinesia

The nature of postirradiation repair in the livers of rats irradiated during hypokinesia is investigated. Hepatocyte population counts, mitotic activity, binuclear cell content, and karyometric studies were done to ascertain the effects of combined hypokinesia and radiation. Hypokinesia is shown to change the nature and rate of post-irradiation changes in the liver, the effect varying with the timing of irradiation relative to the length of hypokinesia. It is concluded that the changes in the compensatory and restorative processes are caused by stress developed in response to isolation and restricted mobility. By changing neuroendocrine system activity, the stress stimulates cell and tissue repair mechanisms at a certain stage essential to the body's reaction of subsequent irradiation.

Chernov, I. P.↗

Gravitational Study of the Central Nervous System

A series of experiments conducted at 1G are discussed with reference to the role of calcium ions in information processing by the central nervous system. A technique is described which allows thin sections of a mammalian hippocampus to be isolated while maintaining neural activity. Two experiments carried out in hypergravic fields are also addressed; one investigating altered stimulation in the auditory system, the other determining temperature regulation responses in hypergravic fields.

Horowitz, J. M.↗

Simulated weightlessness in fish and neurophysiological studies on memory storage

Simulated weightlessness was used to study the different types of gravity responses in blind fish. It was found that a shift in the direction of low magnitude acceleration in weightlessness causes a rapid 180 deg turn in the blind fish, while a shift in the direction of the applied acceleration in the earth's gravitational field is not significant because of a higher acceleration magnitude threshold than during the zero g condition. This increased responsiveness seems to be explained by a combination of directional sensitivity with a Weber-Fechner relationship of increased receptor sensitivity at diminished levels of background stimulation. Neurophysical studies of the statocyst nerve of the gastropod Mollusc Pleurobranchaea Californica were undertaken in order to understand how complex otolith systems operate. Information storage was investigated on relatively simple neuronal networks in the mollusc Aplysia. Intracellular electrical stimulation of isolated neurons show that a manipulation of autoditonous rhymicity is possible. It was also found that glycolysis and oxidative phosphorylation are involved in inherent rhymicity of Aplysis neurons.

Vonbaumgarten, R. J.↗

ZIPPER: Zonal isolation with plug and perf in enhanced reservoirs (Final Technical Report)

Modern multistage hydraulic stimulation treatments in cased wellbores require an effective method of isolating stages between treatments. A commonly used method in the oil and gas industry, plug and perf, is not currently viable for Enhanced Geothermal Systems (EGS) due to limitations of a critical component of the system – the ball drop (flow through) frac plug. Commercially available ball drop frac plugs do not meet the temperature or wellbore diameter requirements needed for use in EGS stimulations. For example, one particular drillable bridge and frac plug line from a large tool developer is only rated to 175 °C, while another is only available up to casing sizes of 5 ½” and rated up to 204 °C. We developed, prototyped, and field tested an upgraded ball drop frac plug to meet the requirements of EGS stimulations, including high-temperature (225+ °C), differential pressure (6000+ psi), and wellbore diameters ranging from 6 5/8” to 10 5/8”. We focused on designs and materials to optimize drillability, a key cost driver in plug and perf systems. The primary objective was to upgrade a drillable frac plug (currently rated to a temperature of 175°C and a pressure of 10,000 psi in 7” casing) to withstand temperatures of 225+°C. The upgraded frac plug was tested in the laboratory as well as in a field trial at a geothermal field. Engineering design and fabrication of the new plug was completed in 2019. Lab testing, validation, and qualification of the plug was completed in 2020. Ultimately the plug was successfully run during a multistage stimulation treatment in a fully horizontal EGS well in 2022. Prior to this project, a ball-drop, flow-through stimulation plug had never been used in a geothermal well. At the conclusion of this project, three different types of zonal isolation plugs were evaluated under full-scale operating conditions across 16 stimulation treatment stages in a first-of-a-kind EGS project called Project Red. This trial included the newly designed high-temperature, large-diameter plug. The plugs met all of 5 the technical requirements for commercial viability. Project Red has since been fully commissioned and is generating electricity on the Nevada grid - the first EGS project to successfully deliver power to the grid in the US.

15 GEOTHERMAL ENERGY↗

Vestibular Stochastic Resonance as a Method to Improve Balance Function: Optimization of Stimulus Characteristics

Stochastic resonance (SR) is a mechanism by which noise can assist and enhance the response of neural systems to relevant sensory signals. Application of imperceptible SR noise coupled with sensory input through the proprioceptive, visual, or vestibular sensory systems has been shown to improve motor function. Specifically, studies have shown that that vestibular electrical stimulation by imperceptible stochastic noise, when applied to normal young and elderly subjects, significantly improved their ocular stabilization reflexes in response to whole-body tilt as well as balance performance during postural disturbances. The goal of this study was to optimize the characteristics of the stochastic vestibular signals for balance performance during standing on an unstable surface. Subjects performed a standardized balance task of standing on a block of 10 cm thick medium density foam with their eyes closed for a total of 40 seconds. Stochastic electrical stimulation was applied to the vestibular system through electrodes placed over the mastoid process behind the ears during the last 20 seconds of the test period. A custom built constant current stimulator with subject isolation delivered the stimulus. Stimulation signals were generated with frequencies in the bandwidth of 1-2 Hz and 0.01-30 Hz. Amplitude of the signals were varied in the range of 0- +/-700 micro amperes with the RMS of the signal increased by 30 micro amperes for each 100 micro amperes increase in the current range. Balance performance was measured using a force plate under the foam block and inertial motion sensors placed on the torso and head segments. Preliminary results indicate that balance performance is improved in the range of 10-25% compared to no stimulation conditions. Subjects improved their performance consistently across the blocks of stimulation. Further the signal amplitude at which the performance was maximized was different in the two frequency ranges. Optimization of the frequency and amplitude of the signal characteristics of the stochastic noise signals on maximizing balance performance will have a significant impact in its development as a unique system to aid recovery of function in astronauts after long duration space flight or for people with balance disorders.

Mulavara, Ajitkumar↗

NASA Tech Briefs, June 2011

Topics covered include: Wind and Temperature Spectrometry of the Upper Atmosphere in Low-Earth Orbit; Health Monitor for Multitasking, Safety-Critical, Real-Time Software; Stereo Imaging Miniature Endoscope; Early Oscillation Detection Technique for Hybrid DC/DC Converters; Parallel Wavefront Analysis for a 4D Interferometer; Schottky Heterodyne Receivers With Full Waveguide Bandwidth; Carbon Nanofiber-Based, High-Frequency, High-Q, Miniaturized Mechanical Resonators; Ultracapacitor-Based Uninterrupted Power Supply System; Coaxial Cables for Martian Extreme Temperature Environments; Using Spare Logic Resources To Create Dynamic Test Points; Autonomous Coordination of Science Observations Using Multiple Spacecraft; Autonomous Phase Retrieval Calibration; EOS MLS Level 1B Data Processing Software, Version 3; Cassini Tour Atlas Automated Generation; Software Development Standard Processes (SDSP); Graphite Composite Panel Polishing Fixture; Material Gradients in Oxygen System Components Improve Safety; Ridge Waveguide Structures in Magnesium-Doped Lithium Niobate; Modifying Matrix Materials to Increase Wetting and Adhesion; Lightweight Magnetic Cooler With a Reversible Circulator; The Invasive Species Forecasting System; Method for Cleanly and Precisely Breaking Off a Rock Core Using a Radial Compressive Force; Praying Mantis Bending Core Breakoff and Retention Mechanism; Scoring Dawg Core Breakoff and Retention Mechanism; Rolling-Tooth Core Breakoff and Retention Mechanism; Vibration Isolation and Stabilization System for Spacecraft Exercise Treadmill Devices; Microgravity-Enhanced Stem Cell Selection; Diagnosis and Treatment of Neurological Disorders by Millimeter-Wave Stimulation; Passive Vaporizing Heat Sink; Remote Sensing and Quantization of Analog Sensors; Phase Retrieval for Radio Telescope and Antenna Control; Helium-Cooled Black Shroud for Subscale Cryogenic Testing; Receive Mode Analysis and Design of Microstrip Reflectarrays; and Chance-Constrained Guidance With Non-Convex Constraints.

Source record↗

High Frequency Design Considerations for the Large Detector Number and Small Form Factor Dual Electron Spectrometer of the Fast Plasma Investigation on NASA's Magnetospheric Multiscale Mission

Each half of the Dual Electron Spectrometer (DES) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission utilizes a microchannel plate Chevron stack feeding 16 separate detection channels each with a dedicated anode and amplifier/discriminator chip. The desire to detect events on a single channel with a temporal spacing of 100 ns and a fixed dead-time drove our decision to use an amplifier/discriminator with a very fast (GHz class) front end. Since the inherent frequency response of each pulse in the output of the DES microchannel plate system also has frequency components above a GHz, this produced a number of design constraints not normally expected in electronic systems operating at peak speeds of 10 MHz. Additional constraints are imposed by the geometry of the instrument requiring all 16 channels along with each anode and amplifier/discriminator to be packaged in a relatively small space. We developed an electrical model for board level interactions between the detector channels to allow us to design a board topology which gave us the best detection sensitivity and lowest channel to channel crosstalk. The amplifier/discriminator output was designed to prevent the outputs from one channel from producing triggers on the inputs of other channels. A number of Radio Frequency design techniques were then applied to prevent signals from other subsystems (e.g. the high voltage power supply, command and data handling board, and Ultraviolet stimulation for the MCP) from generating false events. These techniques enabled us to operate the board at its highest sensitivity when operated in isolation and at very high sensitivity when placed into the overall system.

Microchannel plates high frequency performance↗

Effects of prior exercise on the action of insulin-like growth factor I in skeletal muscle

Prior exercise increases insulin sensitivity for glucose and system A neutral amino acid transport activities in skeletal muscle. Insulin-like growth factor I (IGF-I) also activates these transport processes in resting muscle. It is not known, however, whether prior exercise increases IGF-I action in muscle. Therefore we determined the effect of a single exhausting bout of swim exercise on IGF-I-stimulated glucose transport activity [assessed by 2-deoxy-D-glucose (2-DG) uptake] and system A activity [assessed by alpha-(methylamino)isobutyric acid (MeAIB) uptake] in the isolated rat epitrochlearis muscle. When measured 3.5 h after exercise, the responses to a submaximal concentration (0.2 nM), but not a maximal concentration (13.3 nM), of insulin for activation of 2-DG uptake and MeAIB uptake were enhanced. In contrast, prior exercise increased markedly both the submaximal (5 nM) and maximal (20 nM) responses to IGF-I for activation of 2-DG uptake, whereas only the submaximal response to IGF-I (3 nM) for MeAIB uptake was enhanced after exercise. We conclude that 1) prior exercise significantly enhances the response to a submaximal concentration of IGF-I for activation of the glucose transport and system A neutral amino acid transport systems in skeletal muscle and 2) the enhanced maximal response for IGF-I action after exercise is restricted to the signaling pathway for activation of the glucose transport system.

Non-NASA Center↗

Effect of fluorocarbons on acetylcholinesterase activity and some counter measures

An isolated vagal sympathetic heart system has been successfully used for the study of the effect of fluorocarbons (FCs) on cardiac performance and in situ enzyme activity. Dichlorodifluoromethane sensitizes this preparation to sympathetic stimulation and to exogenous epinephrine challenge. Partial and complete A-V block and even cardiac arrest have been induced by epinephrine challenge in the FC sensitized heart. Potassium chloride alone restores the rhythmicity but not the normal contractility of the heart in such a situation. Addition of glucose will, however, completely restore the normal function of the heart which is sensitized by dichlorodifluoromethane. The ED 50 values of acetylcholinesterase activity which are used as a measure of relative effectiveness of fluorocarbons are compared with the maximum permissible concentration. Kinetic studies indicate that all the fluorocarbons tested so far are noncompetitive.

Young, W.↗

Moving Through Time: The Utility of a Temporal Metric for Vehicular Control

Recent work on time-to-contact (TTC) and time-to-passage (TTP) estimation have revealed conflicting evidence. On the one hand, when tau information is available, observers often fail to use it properly. For instance, absolute size of the object, rotation, and contrast all interfere with estimation accuracy. That is, the visual system often is unable to isolate tau. On the other hand, judgments are remarkably robust when invariant information is no longer available. Observers seem to adjust to many disturbances. This symposium intends to stimulate a discussion of recent findings within visual and auditory TTC paradigms. Alternative concepts that are able to accommodate these findings should be entertained and, if found valid, incorporated into the classic theory of temporal-range estimation.

Kaiser, Mary K.↗

Technology Development to Support Human Health and Performance in Exploration Beyond Low Earth Orbit

In the course of defining the level of risks and mitigating the risks for exploration missions beyond low Earth orbit, NASA s Human Research Program (HRP) has identified the need for technology development in several areas. Long duration missions increase the risk of serious medical conditions due to limited options for return to Earth; no resupply; highly limited mass, power, volume; and communication delays. New space flight compatible medical capabilities required include: diagnostic imaging, oxygen concentrator, ventilator, laboratory analysis (saliva, blood, urine), kidney stone diagnosis & treatment, IV solution preparation and delivery. Maintenance of behavioral health in such an isolated, confined and extreme environment requires new sensory stimulation (e.g., virtual reality) technology. Unobtrusive monitoring of behavioral health and treatment methods are also required. Prolonged exposure to weightlessness deconditions bone, muscle, and the cardiovascular system. Novel exercise equipment or artificial gravity are necessary to prevent deconditioning. Monitoring of the degree of deconditioning is required to ensure that countermeasures are effective. New technologies are required in all the habitable volumes (e.g., suit, capsule, habitat, exploration vehicle, lander) to provide an adequate food system, and to meet human environmental standards for air, water, and surface contamination. Communication delays require the crew to be more autonomous. Onboard decision support tools that assist crew with real-time detection and diagnosis of vehicle and habitat operational anomalies will enable greater autonomy. Multi-use shield systems are required to provide shielding from solar particle events. The HRP is pursuing the development of these technologies in laboratories, flight analog environments and the ISS so that the human health and performance risks will be acceptable with the available resources.

Kundrot, C.E.↗

Detection and quantification of proppant for optimized fracture treatment design in in-fill and new wells

A system and method for detecting and quantifying proppant for optimized fracture treatment design in in-fill and new wells. Proppant is isolated from drilling fluids and then analyzed to determine whether a formation within the well has been properly stimulated based on the analysis. Placement of an in-fill well may be based upon the determination of whether the well has been properly stimulated.

04 OIL SHALES AND TAR SANDS↗

Evaluation of Galvanic Vestibular Stimulation System

Microgravity exposure results in an adaptive central reinterpretation of information from multiple sensory sources to produce a sensorimotor state appropriate for motor actions in this unique environment, but this new adaptive state is no longer appropriate for the 1-g gravitational environment on Earth. During these gravitational transitions, astronauts experience deficits in both perceptual and motor functions including impaired postural control, disruption in spatial orientation, impaired control of locomotion that include alterations in muscle activation variability, modified lower limb kinematics, alterations in head-trunk coordination as well as reduced dynamic visual acuity. Post-flight changes in postural and locomotor control might have adverse consequences if a rapid egress was required following a long-duration mission, where support personnel may not be available to aid crewmembers. The act of emergency egress includes, but is not limited to standing, walking, climbing a ladder, jumping down, monitoring displays, actuating discrete controls, operating auxiliary equipment, and communicating with Mission Control and recovery teams while maintaining spatial orientation, mobility and postural stability in order to escape safely. The average time to recover impaired postural control and functional mobility to preflight levels of performance has been shown to be approximately two weeks after long-duration spaceflight. The postflight alterations are due in part to central reinterpretation of vestibular information caused by exposure to microgravity. In this study we will use a commonly used technique of transcutaneous electrical stimulation applied across the vestibular end organs (galvanic vestibular stimulation, GVS) to disrupt vestibular function as a simulation of post-flight disturbances. The goal of this project is an engineering human-in-the-loop evaluation of a device that can degrade performance of functional tasks (e.g. to maintain upright balance) similar to what astronauts experience during transitions to new gravitational environments. Stochastic electrical stimulation can be applied to the vestibular system through electrodes placed over the mastoid process behind the ears in the binaural configuration resulting in stimulation in the mediolateral (side-to-side) plane. An additional electrode can be placed over the bony landmark of the tip of the c7 spinous process for the double monaural configuration, which will cause stimulation in the anteroposterior (forward-backward) plane. A portable constant current bipolar stimulator with subject isolation was designed and built to deliver the stimulus. The unit is powered using a 3.7 V battery pack and designed to produce currents up to 5 mA. The stimulator, controlled by a Raspberry Pi 3 computer, offers several stimulus signal generation options including a standalone mode, which uses onboard signal files stored on the flash memory card. Stochastic stimulation signals will be generated in 0-30 Hz frequency bandwidth. Stimulation amplitude can be increased incrementally to a maximum amplitude of 5.0 mA (e.g., 0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mA). In control trials, subjects will be experiencing vestibular stimulation with 0-mA current applied through the electrodes. The system will be evaluated at various levels of stimulation and in both the binaural and double monaural electrode configurations. One of the objectives is to identify stimulation levels producing effects most comparable to the post-flight disturbances. This is a pilot study that will set the stage for a larger, more comprehensive study that will investigate wider aspects of post-flight sensorimotor dysfunction and set sensorimotor standards for crew health.

Kofman, I. S.↗