Validation of Printed Strain Gauges at Moderate Temperatures (up to 300°C)

Strain gauges in material test reactors serve to generate critical mechanical property data for qualifying the performance of reactor components. Resistance based strain gauge technologies are both well established and commercially available; however, they present limitations in terms of reactor experiment conditions, especially in areas where physical space is a challenge. In this work, an additively manufactured capacitance-based strain gauge was printed on a stainless-steel specimen and tested at up to the prototypic pressurized-water reactor operating temperature of 300°C. In addition, a high-temperature resistive strain gauge (RSG) was used to better understand how the RSGs operate, and to provide baseline measurements for comparison against the printed strain gauges. Future development of printed strain gauges will focus on expanding their temperature limits to 500°C and enabling applications currently beyond the capabilities of commercial RSGs.

36 MATERIALS SCIENCE↗

Effects of Coatings on Water Intrusion and Strain Gauge Durability in Submerged Fatigue Conditions: Preprint

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand the combined effects of moisture intrusion and mechanical fatigue on marine energy structures, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Measuring strain is critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions was not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure, strains, and strain gauge failure modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite fatigue testing↗

M3AS-25IN1002073: Analysis of data from irradiation testing of printed strain gauges in prototypic nuclear environments

Advancement in additively manufactured strain gauges help address critical technology gaps to accurately monitor real-time materials behavior in reactor experiments. This is critical as it provides data to inform predictive models and simulations that enhance the development of reactors and fuel cycle systems. In this report, additively manufactured strain gauges are exposed to a neutron irradiation environment at the Ohio State University Research Reactor. This report goes over a 2-week campaign for neutron irradiating printed resistive strain gauges and capacitive strain gauges. These results complement the prior separate effects (i.e., mechanical strain, temperature, etc.) testing that were performed on these additive manufactured sensors and presented in prior milestone reports. These results also help progress our understanding of their usage in harsh environment applications. The outcome of developing advanced sensing and instrumentation capabilities plays an important role in increasing the safety, reliability, and energy efficiency of both next-generation and existing nuclear reactors.

36 - MATERIALS SCIENCE↗

Effects of Strain Gauge Coatings on Water Intrusion in Submerged Composite Coupon Testing

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand their combined effects, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Strain measurements are critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions is not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure (SGF), strains, and SGF modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The coatings did not have significant effects on composite fatigue life or strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite materials↗

Printed Strain Gauges for High Temperature Applications (>300°C)

The real-time understanding of strain and deformation of materials provides prognostic health monitoring of components of current operational reactors and valuable data that shortens the timeline for the development of new nuclear-relevant materials in test reactor experiments. This report discusses the current development and testing of additively manufactured strain gauges. This has potential to improve the sensor design and manufacturing techniques to meet the requirements of the current and advanced nuclear reactors (i.e., in terms of environment conditions, sample geometry, and materials compatibility). The developmental additively manufactured strain gauges are exposed to separate effects testing (i.e., mechanical strain, high temperature) to determine environmental factors that affect the strain gauge. In addition, sensor qualification methodologies are further developed for determining the reliability and robustness at the interface of the AM strain gauge materials.

36 MATERIALS SCIENCE↗

Application of printed strain gauges in prototypical nuclear reactor conditions

This report discusses the current development and testing of additively manufactured temperature sensors and resistive/ capacitive strain gauges. This has potential to improve the sensor design and manufacturing techniques to meet the requirements of in-pile monitoring of mechanical properties and structural health of materials and specimens in current and advanced nuclear test reactors (i.e., in terms of environment conditions, sample geometry, and materials compatibility). The developmental additively manufactured strain gauges are exposed to separate effects testing (i.e., mechanical strain (up to 1000 µe), high temperature (up to 700 °C)) to determine environmental factors that affect the performance of the strain gauge. The robustness and integrity of a printed strain gauge layer exposed to a molten salt environment for up to 500 hours was evaluated, with the goal of assessing material compatibility of printed strain sensors for instrumented surveillance test articles in molten salt reactors. In addition, sensor qualification methodologies are further developed for determining the reliability and robustness at the interface of the additively manufactured strain gauge materials.

36 - MATERIALS SCIENCE↗

Aerosol jet printed capacitive strain gauge for soft structural materials

Soft structural textiles, or softgoods, are used within the space industry for inflatable habitats, parachutes and decelerator systems. Evaluating the safety and structural integrity of these systems occurs through structural health monitoring systems (SHM), which integrate non-invasive/non-destructive testing methods to detect, diagnose, and locate damage. Strain/load monitoring of these systems is limited while utilizing traditional strain gauges as these gauges are typically stiff, operate at low temperatures, and fail when subjected to high strain that is a result of high loading classifying them as unsuitable for SHM of soft structural textiles. For this work, a capacitance based strain gauge (CSG) was fabricated via aerosol jet printing (AJP) using silver nanoparticle ink on a flexible polymer substrate. Printed strain gauges were then compared to a commercially available high elongation resistance-based strain gauge (HE-RSG) for their ability to monitor strained Kevlar straps having a 26.7?kN (6?klbf) load. Dynamic, static and cyclic loads were used to characterize both types of strain monitoring devices. Printed CSGs demonstrated superior performance for high elongation strain measurements when compared to commonly used HE-RSGs, and were observed to operate with a gauge factor of 5.2 when the electrode arrangement was perpendicular to the direction of strain.

36 MATERIALS SCIENCE↗

Propagation of Noise Uncertainty Through Virtual Strain Gauge Formulations for 2D Digital Image Correlation

The effect of displacement uncertainty is examined on 2-dimensional strain, calculated using linear surfaces fitted to the displacement field. A classical engineering error propagation method is used to calculate uncertainty in Green-Lagrangian strain calculations. The derived uncertainty is compared to a Monte Carlo simulation and discrepancies under 2% are seen between these two methods. The effect of virtual strain gauge size, displacement uncertainty, and boundaries on the region of interest on the strain uncertainty are considered. Here, an exponential decay relationship is observed between strain uncertainty and virtual strain gauge size, while a linear relationship is seen between strain and displacement uncertainty. For boundaries in the region of interest, strain uncertainty is affected by the reduced number of points available to perform the regression.

42 ENGINEERING↗

Printed Strain Gauges for Anthropomorphic Test Dummies for Vehicle Crash Testing

In Phase 1 of the technical collaboration between Oak Ridge National Laboratory (ORNL) and Humanetics, additive manufacturing was studied as a method to produce high strain – strain gauges that are embedded in an additively manufactured (AM) anthropomorphic crash test dummy (ATD) to provide high fidelity data to significantly improve vehicle safety. In this study commercially available conductive filament was acquired and the mechanical properties were tested for use in this application. The design space of embedded printed strain gauges was explored with multiple configurations printed and tested for performance. The testing resulted in finding that commercially available filament materials were unable to meet the performance requirements. Finally, an extensive literature survey was performed on advanced manufacturing techniques and novel high strain conductive materials to manufacture strain gauges that can be embedded in to the AM ATD. Humanetics have taken the literature survey and have reached out to material suppliers such as Techmer to provide custom blends of materials for testing. Humanetics will continue to build off of the research that was performed and test custom materials for use in AM ATDs.

36 MATERIALS SCIENCE↗

Strain gauge for testing microreactor hexagonal core blocks in the Single Primary Heat Extraction and Removal Emulator

To support the development and deployment of microreactor technologies, experiments that help verify and validate reactor systems and components are performed at non-nuclear test facilities. The Single Primary Heat Extraction Removal Emulator at Idaho National Laboratory is one of these test facilities and was used to monitor a test article that has a prototypic geometry of a heat-pipe cooled microreactor core block. To collect crucial temperature and strain data during testing, temperature and strain sensing fiber optics were embedded to the surface of the test article using an ultrasonic additive manufacturing technique. To support and provide benchmark strain data for the embedded sensors, a commercial resistive strain gauge was attached. This report will discuss the results from the deployment of the commercial strain gauge which includes the setup/attachment strategies, data acquisition, and analysis of the strain data.

36 MATERIALS SCIENCE↗

Strain Gauge Diagnostic Development for use in Vessel Health Monitoring for Hydro-shots

Six-foot vessels are a crucial component to protecting high fidelity equipment at DARHT. Analysis shows these vessels have a limited life span (~10 shots) due to fatigue, ratcheting, and damage accumulation. Vessel health monitoring and diagnostics can help inform decision on a vessel’s fitness for service. Strain gauges are an easy and effective sensor for use in vessel health monitoring. In early March, J-2 executed a qualification shot, uniform blast loading with minimal fragments, with bi-axial strain gauges fielded at four locations around vessel. Several damage features were extracted from the data, and frequency content helps to validate computer modelling of the vessel response. Permanent plastic strain at each location was significant with location one having the most strain at the end state, with 230 micro-strain. However, residual pressure in the vessel could be a major factor in this strain. PEEQ is a measure of total plastic equivalent strain accumulation. The equivalent strain at location one exceeded the plastic strain limit four times and accumulated the most PEEQ with 2036 micro-strain. As expected, this qualification shot did contribute to damage in the vessel, and should be considered in its fitness for service, but not critical enough to pull it from service. Frequency content also gave valuable information on the modal response of the vessel and contributes to the understanding of how the vessel responds to the initial blast load with an expected lower frequency membrane/breathing mode and transitioning to higher frequency bending modes in the vessel wall.

42 ENGINEERING↗

Tunneling Barrier-Integrated Gold Nanofilms for Negative Strain Gauging with Near-Zero Energy Consumption

Wireless strain sensors with minimal power needs are essential for long-term monitoring in energy-limited environments. We present a soft tunneling barrier-integrated gold thin film for negative strain sensing with near-zero energy consumption. The device features a strain-induced transition from an insulating to a metallic state, increasing conductivity by 9 orders of magnitude under a controlled strain. It consists of Au-PDMS-Au nanofilm layers, where the Au structures are near the percolation threshold and the PDMS layer acts as a tunneling barrier. Under strain, thinning due to the Poisson effect lowers the barrier’s potential height, enabling electron tunneling and forming an electrical path. Further, with a standby power consumption of ~10 –5 mW over 10 6 times lower than conventional sensors (~12.5 mW), this device is ideal for real-time, long-term stationary structural monitoring in multiple locations.