Search NASA⌕ Search

SEARCH · Search NASA

Results for “strain imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Subclinical Cardiac Dysfunction Detected by Strain Imaging During Breast Irradiation With Persistent Changes 6 Weeks After Treatment

Purpose: To evaluate 2-dimensional strain imaging (SI) for the detection of subclinical myocardial dysfunction during and after radiation therapy (RT). Methods and Materials: Forty women with left-sided breast cancer, undergoing only adjuvant RT to the left chest, were prospectively recruited. Standard echocardiography and SI were performed at baseline, during RT, and 6 weeks after RT. Strain (S) and strain rate (Sr) parameters were measured in the longitudinal, circumferential, and radial planes. Correlation of change in global longitudinal strain (GLS % and Δ change) and the volume of heart receiving 30 Gy (V30) and mean heart dose (MHD) were examined. Results: Left ventricular ejection fraction was unchanged; however, longitudinal systolic S and Sr and radial S were significantly reduced during RT and remained reduced at 6 weeks after treatment [longitudinal S (%) −20.44 ± 2.66 baseline vs −18.60 ± 2.70* during RT vs −18.34 ± 2.86* at 6 weeks after RT; longitudinal Sr (s{sup −1}) −1.19 ± 0.21 vs −1.06 ± 0.18* vs −1.06 ± 0.16*; radial S (%) 56.66 ± 18.57 vs 46.93 ± 14.56* vs 49.22 ± 15.81*; *P<.05 vs baseline]. Diastolic Sr were only reduced 6 weeks after RT [longitudinal E Sr (s{sup −1}) 1.47 ± 0.32 vs 1.29 ± 0.27*; longitudinal A Sr (s{sup −1}) 1.19 ± 0.31 vs 1.03 ± 0.24*; *P<.05 vs baseline], whereas circumferential strain was preserved throughout. A modest correlation between S and Sr and V30 and MHD was observed (GLS Δ change and V30 ρ = 0.314, P=.05; GLS % change and V30 ρ = 0.288, P=.076; GLS Δ change and MHD ρ = 0.348, P=.03; GLS % change and MHD ρ = 0.346, P=.031). Conclusions: Subclinical myocardial dysfunction was detected by 2-dimensional SI during RT, with changes persisting 6 weeks after treatment, though long-term effects remain unknown. Additionally, a modest correlation between strain reduction and radiation dose was observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-resolution high-throughput spatiotemporal strain imaging reveals loss mechanisms in a surface acoustic wave device

Surface acoustic wave devices are key components for processing radio frequency signals in wireless communication because these devices offer simultaneously high performance, compact size and low cost. The optimization of the device structure requires a quantitative understanding of energy conversion and loss mechanisms. Here we use stroboscopic full-field diffraction x-ray microscopy to reveal an unanticipated acoustic loss in a prototypical one-port resonator device. A non-uniform acoustic excitation in the active area was responsible for the substantial end and side leakages observed at the design frequency. Quantitative analysis of the strain amplitude using a wave decomposition method allowed the determination of several key device parameters. This high-resolution high-throughput spatiotemporal strain imaging technique is more generally applicable to the study of dynamic strain modulation in nanoscale acoustic, electronic, optical and quantum devices. The high sensitivity allows precise measurement of the strain modulation with picometer-scale amplitude.

Zhou, Tao [ESRF - The European Synchrotron, Grenob↗

Strain Imaging of Nanoscale Semiconductor Heterostructures with X-Ray Bragg Projection Ptychography

We report the imaging of nanoscale distributions of lattice strain and rotation in complementary components of lithographically engineered epitaxial thin film semiconductor heterostructures using synchrotron x-ray Bragg projection ptychography (BPP). We introduce a new analysis method that enables lattice rotation and out-of-plane strain to be determined independently from a single BPP phase reconstruction, and we apply it to two laterally adjacent, multiaxially stressed materials in a prototype channel device. These results quantitatively agree with mechanical modeling and demonstrate the ability of BPP to map out-of-plane lattice dilatation, a parameter critical to the performance of electronic materials.

Holt, Martin V.↗

Three-dimensional strain imaging of irradiated chromium using multi-reflection Bragg coherent diffraction

Abstract Radiation-induced materials degradation is a key concern in limiting the performance of nuclear materials. The formation of nanoscale void and gas bubble superlattices in metals and alloys under radiation environments can effectively mitigate radiation-induced damage, such as swelling and aid the development of next generation radiation tolerant materials. To effectively manage radiation-induced damage via superlattice formation, it is critical to understand the microstructural changes and strain induced by such superlattices. We utilize multi-reflection Bragg coherent diffraction imaging to quantify the full strain tensor induced by void superlattices in iron irradiated chromium substrate. Our approach provides a quantitative estimation of radiation-induced three-dimensional (3D) strain generated at the microscopic level and predicts the number density of defects with a high degree of sensitivity. Such quantitative evaluation of 3D strain in nuclear materials can have a major impact on predicting materials behavior in radiation environments and can revolutionize design of radiation tolerant materials.

36 MATERIALS SCIENCE↗

Deterministic nanoscale quantum spin-defect implantation and diffraction strain imaging

Abstract Local crystallographic features negatively affect quantum spin defects by changing the local electrostatic environment, often resulting in degraded or varied qubit optical and coherence properties. Few tools exist that enable the deterministic synthesis and study of such intricate systems on the nano-scale, making defect-to-defect strain environment quantification difficult. In this paper, we highlight state-of-the-art capabilities from the U.S. Department of Energy’s Nanoscale Science Research Centers that directly address these shortcomings. Specifically, we demonstrate how complementary capabilities of nano-implantation and nano-diffraction can be used to demonstrate the quantum relevant, spatially deterministic creation of neutral divacancy centers in 4H silicon carbide, while investigating and characterizing these systems on the ≤ 25 nm scale with strain sensitivities on the order of 1 × 10 − 6 , relevant to defect formation dynamics. This work lays the foundation for ongoing studies into the dynamics and deterministic formation of low strain homogeneous quantum relevant spin defects in the solid state.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Acquisition, Sharing and Processing of Large Datasets for Strain Imaging: an Example of an Indented Ni3Al/Mo Composite

The local effects of stress from a mechanical indentation have been studied on a Ni3 Al single crystal containing submicron inclusions of molybdenum fibers. Polychromatic X ray Microscopy (PXM) was used to measure elastic and plastic deformations near the indents. Analysis of freshly acquired massive sets of PXM data has been carried out over the Science Studio network using parallel processing software FOXMAS. This network and the FOXMAS software have greatly improved the efficiency of the data processing task.. The analysis was successfully applied to study lattice orientation distribution and strain tensor components for both the Ni3 Al and the Mo phases, particularly around 8 indents patterned at the longitudinal section of the alloy.

data processing↗

Potential pitfalls of strain rate imaging: angle dependency

Strain Rate Imaging (SRI) is a new echocardiographic technique that allows for the real-time determination of myocardial SR, which may be used for the early and accurate detection of coronary artery disease. We sought to study whether SR is affected by scan line alignment in a computer simulation and an in vivo experiment. Through the computer simulation and the in vivo experiment we generated and validated safe scanning sectors within the ultrasound scan sector and showed that while SRI will be an extremely valuable tool in detecting coronary artery disease there are potential pitfalls for the unwary clinician. Only after accounting for these affects due to angle dependency, can clinicians utilize SRI's potential as a valuable tool in detecting coronary artery disease.

NASA Discipline Cardiopulmonary↗

Electrochemically Induced Strain Evolution in Pt–Ni Alloy Nanoparticles Observed by Bragg Coherent Diffraction Imaging

Strain is known to enhance the activity of the oxygen reduction reaction in catalytic platinum alloy nanoparticles, whose inactivity is the primary impediment to efficient fuel cells and metal–air batteries. Here, Bragg coherent diffraction imaging (BCDI) was employed to reveal the strain evolution during the voltammetric cycling in Pt–Ni alloy nanoparticles composed of Pt 2 Ni 3 , Pt 1 Ni 1 , and Pt 3 Ni 2 . Analysis of the 3D strain images using a core–shell model shows that the strain as large as 5% is induced on Pt-rich shells due to Ni dissolution. The composition dependency of the strain on the shells is in excellent agreement with that of the catalytic activity. The present study demonstrates that BCDI enables quantitative determination of the strain on alloy nanoparticles during electrochemical reactions, which provides a means to exploit surface strain to design a wide range of electrocatalysts.

36 MATERIALS SCIENCE↗

WE-EF-210-06: Ultrasound 2D Strain Measurement of Radiation-Induced Toxicity: Phantom and Ex Vivo Experiments

Purpose: Radiation-induced fibrosis is a common long-term complication affecting many patients following cancer radiotherapy. Standard clinical assessment of subcutaneous fibrosis is subjective and often limited to visual inspection and palpation. Ultrasound strain imaging describes the compressibility (elasticity) of biological tissues. This study’s purpose is to develop a quantitative ultrasound strain imaging that can consistently and accurately characterize radiation-induce fibrosis. Methods: In this study, we propose a 2D strain imaging method based on deformable image registration. A combined affine and B-spline transformation model is used to calculate the displacement of tissue between pre-stress and post-stress B-mode image sequences. The 2D displacement is estimated through a hybrid image similarity measure metric, which is a combination of the normalized mutual information (NMI) and normalized sum-of-squared-differences (NSSD). And 2D strain is obtained from the gradient of the local displacement. We conducted phantom experiments under various compressions and compared the performance of our proposed method with the standard cross-correlation (CC)- based method using the signal-to-noise (SNR) and contrast-to-noise (CNS) ratios. In addition, we conducted ex-vivo beef muscle experiment to further validate the proposed method. Results: For phantom study, the SNR and CNS values of the proposed method were significantly higher than those calculated from the CC-based method under different strains. The SNR and CNR increased by a factor of 1.9 and 2.7 comparing to the CC-based method. For the ex-vivo experiment, the CC-based method failed to work due to large deformation (6.7%), while our proposed method could accurately detect the stiffness change. Conclusion: We have developed a 2D strain imaging technique based on the deformable image registration, validated its accuracy and feasibility with phantom and ex-vivo data. This 2D ultrasound strain imaging technology may be valuable as physicians try to eliminate radiation-induce fibrosis and improve the therapeutic ratio of cancer radiotherapy. This research is supported in part by DOD PCRP Award W81XWH-13-1-0269, and National Cancer Institute (NCI) Grant CA114313.

60 APPLIED LIFE SCIENCES↗

Subclinical Cardiotoxicity Detected by Strain Rate Imaging up to 14 months After Breast Radiation Therapy

Purpose: Strain rate imaging (SRI) is a new echocardiographic modality that enables accurate measurement of regional myocardial function. We investigated the role of SRI and troponin I (TnI) in the detection of subclinical radiation therapy (RT)-induced cardiotoxicity in breast cancer patients. Methods and Materials: This study prospectively included 75 women (51 left-sided and 24 right-sided) receiving adjuvant RT to the breast/chest wall and regional lymph nodes. Sequential echocardiographs with SRI were obtained before RT, immediately after RT, and 8 and 14 months after RT. TnI levels were measured on the first and last day of RT. Results: Mean heart and left ventricle (LV) doses were both 9 ± 4 Gy for the left-sided patients and 4 ± 4 Gy and 1 ± 0.4 Gy, respectively, for the right-sided patients. A decrease in strain was observed at all post-RT time points for left-sided patients (−17.5% ± 1.9% immediately after RT, −16.6% ± 1.4% at 8 months, and −17.7% ± 1.9% at 14 months vs −19.4% ± 2.4% before RT, P<.01) but not for right-sided patients. When we considered left-sided patients only, the highest mean dose was given to the anterior left ventricular (LV) wall (25 ± 14 Gy) and the lowest to the inferior LV wall (3 ± 3 Gy). Strain of the anterior wall was reduced after RT (−16.6% ± 2.3% immediately after RT, −16% ± 2.6% at 8 months, and −16.8% ± 3% at 14 months vs −19% ± 3.5% before RT, P<.05), whereas strain of the inferior wall showed no significant change. No changes were observed with conventional echocardiography. Furthermore, mean TnI levels for the left-sided patients were significantly elevated after RT compared with before RT, whereas TnI levels of the right-sided patients remained unaffected. Conclusions: In contrast to conventional echocardiography, SRI detected a regional, subclinical decline in cardiac function up to 14 months after breast RT. It remains to be determined whether these changes are related to clinical outcome. In the meantime, we encourage the use of radiation techniques that minimize the exposure of the anterior LV wall in left-sided patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Radiation Effects on Cardiac Function Detected by Strain Rate Imaging in Breast Cancer Patients

Purpose: To investigate the occurrence of early radiation-induced changes in regional cardiac function using strain rate imaging (SRI) by tissue Doppler echocardiography. Methods and Materials: We included 20 left-sided and 10 right-sided breast cancer patients receiving radiotherapy (RT) to the breast or chest wall. Standard echocardiography and SRI were performed before RT (baseline), immediately after RT (post-RT), and at 2 months follow-up (FUP) after RT. Regional strain (S) and strain rate (SR) values were obtained from all 18 left ventricular (LV) segments. Data were compared to the regional radiation dose. Results: A reduction in S was observed post-RT and at FUP in left-sided patients (S{sub post-RT}: -17.6 {+-} 1.5%, and S{sub FUP}: -17.4 {+-} 2.3%, vs. S{sub baseline}: -19.5 {+-} 2.1%, p < 0.001) but not in right-sided patients. Within the left-sided patient group, S and SR were significantly reduced after RT in apical LV segments (S{sub post-RT}: -15.3 {+-} 2.5%, and S{sub FUP}: -14.3 {+-} 3.7%, vs. S{sub baseline}: -19.3 {+-} 3.0%, p < 0.01; and SR{sub post-RT}: -1.06 {+-} 0.15 s {sup -1}, and SR{sub FUP}: -1.16 {+-} 0.28 s {sup -1}, vs. SR{sub baseline}: -1.29 {+-} 0.27s {sup -1}, p = 0.01), but not in mid- or basal segments. Furthermore, we observed that segments exposed to more than 3 Gy showed a significant decrease in S after RT (S{sub post-RT}: -16.1 {+-} 1.6%, and S{sub FUP}: -15.8 {+-} 3.4%, vs. S{sub baseline}: -18.9 {+-} 2.6%, p < 0.001). This could not be observed in segments receiving less than 3 Gy. Conclusions: SRI shows a dose-related regional decrease in myocardial function after RT. It might be a useful tool in the evaluation of modern RT techniques, with respect to cardiac toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large Area and Depth-Profiling Dislocation Imaging and Strain Analysis in Si/SiGe/Si Heterostructures

We demonstrate the combined use of large area depth-profiling dislocation imaging and quantitative composition and strain measurement for a strained Si/SiGe/Si sample based on nondestructive techniques of electron beam-induced current (EBIC) and X-ray diffraction reciprocal space mapping (XRD RSM). Depth and improved spatial resolution is achieved for dislocation imaging in EBIC by using different electron beam energies at a low temperature of ~7 K. Images recorded clearly show dislocations distributed in three regions of the sample: deep dislocation networks concentrated in the “strained” SiGe region, shallow misfit dislocations at the top Si/SiGe interface, and threading dislocations connecting the two regions. Dislocation densities at the top of the sample can be measured directly from the EBIC results. XRD RSM reveals separated peaks, allowing a quantitative measurement of composition and strain corresponding to different layers of different composition ratios. High-resolution scanning transmission electron microscopy cross-section analysis clearly shows the individual composition layers and the dislocation lines in the layers, which supports the EBIC and XRD RSM results.

36 MATERIALS SCIENCE↗

In-Situ X-Ray Imaging High Strain Rate Compression of Laminate Al-Graphene Composite and Mechanical Property Characterization

Owing to the opaque nature of the laminated structures, traditional high-speed optical camera cannot be used to detect the dynamic process of sub-surface deformation. In this article, we report a study of using high speed X-ray imaging to study the high strain rate deformation in laminated Al structures. We used a Kolsky bar apparatus to apply dynamic compression and a high-speed synchrotron X-ray phase contrast imaging (PCI) setup to conduct the in situ X-ray imaging study. The in situ X-ray imaging captures the shock wave propagation in the laminated structures. After shock compression, we characterized the microstructures by using transmission electron microscopy (TEM), which demonstrates an increase of dislocation density. In conclusion, the micro-pillar compression tests show that the yield strength at 0.2% offset of laminated Al-graphene composite has a significant increase of 67%, from 30 to 50 MPa, compared to laminate Al after shock loading.

36 MATERIALS SCIENCE↗

Experimental Examination of Additively Manufactured Patterns on Structural Nuclear Materials for Digital Image Correlation Strain Measurements

Abstract Background There are a limited number of commercially available sensors for monitoring the deformation of materials in-situ during harsh environment applications, such as those found in the nuclear and aerospace industries. Such sensing devices, including weldable strain gauges, extensometers, and linear variable differential transformers, can be destructive to material surfaces being investigated and typically require relatively large surface areas to attach (> 10 mm in length). Digital image correlation (DIC) is a viable, non-contact alternative to in-situ strain deformation. However, it often requires implementing artificial patterns using splattering techniques, which are difficult to reproduce. Objective Additive manufacturing capabilities offer consistent patterns using programmable fabrication methods. Methods In this work, a variety of small-scale periodic patterns with different geometries were printed directly on structural nuclear materials (i.e., stainless steel and aluminum tensile specimens) using an aerosol jet printer (AJP). Unlike other additive manufacturing techniques, AJP offers the advantage of materials selection. DIC was used to track and correlate strain to alternative measurement methods during cyclic loading, and tensile tests (up to 1100 µɛ) at room temperature. Results The results confirmed AJP has better control of pattern parameters for small fields of view and facilitate the ability of DIC algorithms to adequately process patterns with periodicity. More specifically, the printed 100 μm spaced dot and 150 μm spaced line patterns provided accurate measurements with a maximum error of less than 2% and 4% on aluminum samples when compared to an extensometer and commercially available strain gauges. Conclusion Our results highlight a new pattern fabrication technique that is form factor friendly for digital image correlation in nuclear applications.

Novich, K. A. (ORCID:0000000204466022)↗

X-ray diffraction imaging of strain fields in a domain-inverted LiTa0{sub 3} crystal.

We investigate lattice orientation and strain fields across ferroelectric domain walls in a single crystal lithium tantalate using x-ray diffraction imaging (topography). The sample is an actual voltage-operated optical switch consisting of a series of triangular polarization-inverted domains formed in an originally poled single crystal. By applying an electric field only about 2% of the coercive field in the forward and reverse directions, we observed asymmetric lattice rotation of about 10{sup -6} rad, and normal strain variation in the order of 10{sup -5} with reference to the zero-field state. Our results confirm that in congruent LiTaO{sub 3} crystals there is unexpectedly large strain field expanding several micrometers across the domain walls, in contrast with the widely accepted theoretical fact that in this material the polarization reversal establishes over only a few lattice constants, resulting in small and localized lattice distortions.

36 MATERIALS SCIENCE↗

Ultrafast Three-Dimensional Integrated Imaging of Strain in Core/Shell Semiconductor/Metal Nanostructures

Visualizing the dynamical response of material heterointerfaces is increasingly important for the design of hybrid materials and structures with tailored properties for use in functional devices. In situ characterization of nanoscale heterointerfaces such as metal-semiconductor interfaces, which exhibit a complex interplay between lattice strain, electric potential, and heat transport at subnanosecond time scales, is particularly challenging. Here in this work, we use a laser pump/X-ray probe form of Bragg coherent diffraction imaging (BCDI) to visualize in three-dimension the deformation of the core of a model core/shell semiconductor-metal (ZnO/Ni) nanorod following laser heating of the shell. We observe a rich interplay of radial, axial, and shear deformation modes acting at different time scales that are induced by the strain from the Ni shell. We construct experimentally informed models by directly importing the reconstructed crystal from the ultrafast experiment into a thermo-electromechanical continuum model. The model elucidates the origin of the deformation modes observed experimentally. Our integrated imaging approach represents an invaluable tool to probe strain dynamics across mixed interfaces under operando conditions.

36 MATERIALS SCIENCE↗

WE-E-9A-01: Ultrasound Elasticity

Principles and techniques of ultrasound-based elasticity imaging will be presented, including quasistatic strain imaging, shear wave elasticity imaging, and their implementations in available systems. Deeper exploration of quasistatic methods, including elastic relaxation, and their applications, advantages, artifacts and limitations will be discussed. Transient elastography based on progressive and standing shear waves will be explained in more depth, along with applications, advantages, artifacts and limitations, as will measurement of complex elastic moduli. Comparisons will be made between ultrasound radiation force techniques, MR elastography, and the simple A mode plus mechanical plunger technique. Progress in efforts, such as that by the Quantitative Imaging Biomarkers Alliance, to reduce the differences in the elastic modulus reported by different commercial systems will be explained. Dr. Hall is on an Advisory Board for Siemens Ultrasound and has a research collaboration with them, including joint funding by R01CA140271 for nonlinear elasticity imaging. Learning Objectives: Be reminded of the long history of palpation of tissue elasticity for critical medical diagnosis and the relatively recent advances to be able to image tissue strain in response to an applied force. Understand the differences between shear wave speed elasticity measurement and imaging and understand the factors affecting measurement and image frame repletion rates. Understand shear wave propagation effects that can affect measurements, such as essentially lack of propagation in fluids and boundary effects, so important in thin layers. Know characteristics of available elasticity imaging phantoms, their uses and limitations. Understand thermal and cavitational limitations affecting radiation force-based shear wave imaging. Have learning and references adequate to for you to use in teaching elasticity imaging to residents and technologists. Be able to explain how elasticity measurement and imaging can contribute to diagnosis of breast and prostate cancer, staging of liver fibrosis, age estimation of deep veinous fhrombosis, confirmation of thermal lesions in the liver after RF ablation.

60 APPLIED LIFE SCIENCES↗