Search NASASearch

SEARCH · Search NASA

Results for “strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Preventive Power Outage Estimation Based on a Novel Scenario Clustering Strategy

The increasing occurrence of extreme weather events is challenging power grid operation. For extreme weather events, the system operator is responsible for estimating the power outages and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The outputs of an outage prediction model tool are used to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers repair crews and mobile energy resources (MERs). Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative profiles which the system operator can focus on. Finally, case studies on a distribution system evaluate the damage caused by an extreme weather event and verify the effectiveness of the proposed scenario clustering strategy.

MATHEMATICS AND COMPUTING,POWER TRANSMISSION AND D

Application-level benchmarking of quantum computers using nonlocal game strategies

In a nonlocal game, two noncommunicating players cooperate to convince a referee that they possess a strategy that does not violate the rules of the game. Quantum strategies allow players to optimally win some games by performing joint measurements on a shared entangled state, but computing these strategies can be challenging. We present a variational quantum algorithm to compute quantum strategies for nonlocal games by encoding the rules of a nonlocal game into a Hamiltonian. We show how this algorithm can generate a short-depth optimal quantum strategy for a graph coloring game with a quantum advantage. This quantum strategy is then evaluated on fourteen different quantum hardware platforms to demonstrate its utility as a benchmark. Finally, we discuss potential sources of errors that can explain the observed decreased performance of the executed task and derive an expression for the number of samples required to accurately estimate the win rate in the presence of noise.

nonlocal games

Multi-site Milling Strategy Reveals Significant Variation in Biomass Composition of Switchgrass ( Panicum virgatum ) Grown at Ten Locations

Cell wall composition influences biomass use as a forage and as a feedstock for biofuel and chemical conversion. To examine the influence of environment on composition of switchgrass (Panicum virgatum L.), we utilized a multi-environment experiment consisting of clones of switchgrass genotypes grown at up to ten locations in the continental US. We tested the influence of different milling treatments on biomass composition trait predictions via near-infrared reflectance spectroscopy (NIRS). We found that most compositional trait predictions (29/34) were significantly different (P < 0.05) when a single lot of biomass was subjected to disparate milling treatments, i.e., knife milling vs. knife milling with an additional cyclone milling. Further, depending on the plant material tested, three to eight compositional trait predictions vary (P < 0.05) when identical biomass was knife milled at different sites followed by cyclone milling at a single site, including for traits such as Klason lignin, nitrogen, and carbon. In some cases, variation due to milling site exceeded environmentally induced compositional variation of a single switchgrass genotype grown at different sites. From these observations, we recommend a protocol with two sequential millings that decouples growth environment from a particular mill. Utilizing this approach, we found that 46/46 biomass composition traits from the warm season herbaceous forage and switchgrass bioethanol NIRS equations vary significantly (P < 0.001) in clones of a switchgrass genotype (WBC) grown at ten sites, with the growth site representing the largest average source of variation (41%). This multi-site milling approach can be used to examine environmental and gene-by-environment influences on composition with the goal of optimizing cell wall composition in different environments for biomass utilization.

09 BIOMASS FUELS

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION

Data for Protoplast Fusion as a Strategy to Increase Ploidy in Rhodotorula toruloides for Strain Development

Rhodotorula toruloides is a red oleaginous yeast with growing commercial interest because of its hardiness and exceptional lipid production capacity. Because it is a basidiomycete yeast with a complex life cycle, many of the classical breeding methods used with ascomycetes are unavailable for strain improvement. However, we have been able to construct polyploid yeast by fusing protoplasts of parents with the same mating type. Fusing of Y-6985 (A2) and Y-48190 (A2), which had been transformed with complementary antibiotic markers, led to the recovery of two diploids and one triploid. The stability of the fusion yeasts was tested by plating them on non-selective medium after several growth cycles under antibiotics and then testing five colonies per strain for nuclear DNA contents using flow cytometry and standard cell cycle analysis: the triploid and one diploid were stable. Fusants inherited their mitochondria from a single parent, which was demonstrated using restriction fragment length polymorphism (RFLP) of mitochondrial DNA. The phenotypic properties of the parents and fusants were compared in glucose fed-batch bioreactor studies and cellulosic sugar batch cultures. The final lipid titers for the fed-batch cultures were 24.9–39.7 g/L with Y-6985 and the diploid and triploid performing the best and worst, respectively. The fusants demonstrated intermediate hardiness for growth on hydrolysate prepared with dilute-acid pretreated switchgrass and were outperformed by Y-48190. Unlike one of the haploid parents, the fusants grew in 70% v/v concentrated hydrolysate. However, they did not grow as fast as the other haploid. In this study, a modernized protoplast fusion method is resurrected a useful tool for strain development in this yeast, which is complementary with other available methods.

FOS: Biological sciences

IBPSA Project 2 BOPTEST: An update on the test cases available in the framework for testing advanced control strategies in buildings

Project 2 develops software infrastructure, test cases, and extensions for the Building Optimization Testing Framework (BOPTEST) to address the expanding needs of building and urban energy system controls through open international collaboration. This paper provides an overview of the new test cases available as of BOPTEST version 0.7.1. Each test case is developed using open-source Modelica libraries and Spawn of EnergyPlus, enabling the creation of high-fidelity building models that incorporate envelope dynamics, Heating Ventilation and Air Conditioning (HVAC) systems, and explicit control representations. Currently, eight test cases are available, with five additional cases under development. These test cases cover a wide range of climates, building types, and HVAC systems. This paper compiles and summarizes test case descriptions, cites original manuscripts that developed them for a more detailed description, and reports baseline control performance metrics. Furthermore, two example applications are presented: one illustrating different levels of control, from supervisory to low-level, and another demonstrating how Model Predictive Control (MPC) solutions must be adapted from continuous to integer to control some building actuators.

Zanetti, Ettore

Greenhouse gas emissions reduction strategies that maximize portfolio-wide life cycle cost reduction, resilience, and environmental justice benefits

While strategies to achieve net-zero emissions at an individual site are well understood, new analysis methods are required for organizations seeking to achieve net-zero across multiple facilities, each with concurrent priority goals. At a portfolio level, distinct locations present varied challenges that cannot be addressed through singular solutions, and competing goals can take precedence with the assumption that net-zero emissions strategies deter from energy resilience and cost savings, therefore negatively impacting nearby communities. This study tests these assumptions by analyzing 16 diverse sites (varying in size, climate, and energy use) to identify strategies that reduce emissions and assess the impact these strategies have on life cycle costs, resilience, and communities with environmental justice concerns. Methods were developed to approximate missing information essential to net-zero evaluation. Established methods were augmented to evaluate life cycle costs, resilience, and environmental justice impacts across a set of strategies and accommodate the multi-criteria analyses. Potential benefits from identified strategies were quantified using site characteristics and a set of corresponding metrics. The net-zero analysis found that 11 sites could use on-site strategies to eliminate all but 2% of emissions generated. The remaining emissions can be offset, for instance through sequestration, executed at the portfolio scale. On-site carbon-free energy was found to reduce 51% of emissions across all sites; efficiency reduced 19% of emissions; sequestration 16%; procured carbon-free energy 15%; fuel switching 1.6%; and fleet electrification 1.3%. Building electrification, however, increased emissions by 4.4%. Different strategies also provide cost, resilience, and/or environmental justice benefits—the degree to which varies with individual site conditions. The findings indicate an advantage to considering the strategies as a comprehensive set, which leads to co-benefits, both in the ability to achieve net-zero goals and in advancing other goals. The results present the case for comprehensive advanced planning at the portfolio level to prioritize investments that will balance the minimization of emissions and life cycle cost with the maximization of resilience and environmental justice benefits. The novel methods for evaluation and integration, valuation of benefits, and consideration at the portfolio scale allow organizations to select investments that simultaneously address multiple key priorities.

Net-Zero Emissions

Comparison of wind-farm control strategies under realistic offshore wind conditions: wake quantities of interest

Wind-farm control strategies aim to increase the efficiency, and therefore lower the levelized cost of energy, of wind farms. This is done by using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the wake that negatively affects downstream turbines in the farm. Two inherently different wind-farm control methods have been identified in the literature: wake steering (WS) and active wake mixing (AWM). As one of two companion papers focused on understanding practical aspects of these two wind-farm control strategies using large-eddy simulation (LES), we below analyze the wake quantities of interest for a single wind turbine performing WS and AWM, while the companion article (Frederik et al., 2025) focuses on turbine quantities of interest including power and structural loads for the same computational setup and also includes two-turbine arrays with full and partial wake overlap. The simulations, which are based in the LES solver AMR-Wind, are tailored to have inflow conditions representative of measurements from a site off the East Coast of the US, including with strong veer and low turbulence. The turbine, which is modeled in OpenFAST and coupled to the LES, is the IEA 15 MW, an open-source offshore design. After presenting an overview of the wake recovery for the different wake-control cases, the analysis probes the fluid-dynamic causes for the different performance of the arrays reported in the companion article by examining control volumes around the wakes and the budget of the mean-flow kinetic energy (MKE) within these volumes. In the high veer environment considered, the MKE recovery is dominated by mean convection, and this is shown to especially benefit the WS strategy when a neighboring turbine is directly downstream: there is ≈65 % more available power for a downstream turbine than in the baseline case, and this power is gained primarily through mean convection on the left-tip and top-tip faces of the control volume. However, the case with imperfect knowledge of the exact wind direction favors the pulse-type AWM strategy, largely because of ≈9 % increased turbulent entrainment from aloft versus the baseline that could be related to an apparent resistance to skewing in the pulsed wake. The general reduced effectiveness of helix-type and other individual-pitch-based AWM strategies for inflow with high veer and low turbulence as reported in the companion paper is due, in part, to low magnitudes of phase-averaged turbulent entrainment. Two main findings of this study are thus that veer has a significant impact on the effectiveness of different wake-control strategies and that pulse-type AWM may be a useful strategy when the objective is power maximization in realistic, offshore flow environments with imperfect knowledge of the exact wake overlap position on the downstream turbine.

17 WIND ENERGY

An analysis of alcohol compression ignition strategies on different engine platforms

Strategies that enable ignition of the low cetane alcohol fuels (methanol and ethanol) include intake heating (direct or via hot residual trapping), increased compression ratio (CR), multi-injection strategies, ignition enhancers, and active prechambers. The literature consistently shows alcohol compression ignition (CI) is more efficient than diesel at high loads irrespective of ignition strategy but shows contradictory results at low loads. To understand this, this work combines data from four different engine platforms ranging from a displaced volume of 0.4 to 2.1 L/cyl. using different alcohol CI ignition strategies. Using modeling to support experimental analysis, alcohol-specific efficiency penalties are highlighted to inform alcohol combustion system development. The alcohols’ lower energy density means more fuel must be injected near top dead center to achieve a given load, increasing the relative penalty of sensible/latent heating. Pilot injections help reduce this penalty. Intake heating incurs both a heat transfer penalty and a thermodynamic penalty due to a reduced ratio of specific heats during compression. A strategy that combines elevated CR, large pilot injections, and ignition enhancers can avoid this penalty. Alternatively, a prechamber strategy can achieve this without changing the CR, nor needing ignition enhancers in the fuel. At low loads, diesel burns in a partially premixed mode characterized by high burn rates and low heat losses, reducing alcohol-specific combustion benefits. Alcohol CI on the light-duty platform showed abnormally high heat transfer over diesel compared to other platforms, favoring a more premixed/partially premixed strategy despite a combustion efficiency tradeoff.

33 ADVANCED PROPULSION SYSTEMS

Strategies to mitigate urban heat: Effects on overheating and cloud formation

This study evaluates the effectiveness of various urban heat island (UHI) overheating mitigation strategies and their associated impacts on urban cloud dynamics and thermal processes. This study shows cloud-resolving and urban-resolving modeling results estimating the impact of Houston-Galveston heat mitigation scenarios and other resilient strategies contemplated in the Climate Adaptation Plan and Resilient Houston reports. The simulated scenarios include high intensity green rooftops, rooftop photovoltaic solar panels, enhanced urban irrigation, white/cool roofs and roads, and street trees. We contrast the adaptation scenarios against a present baseline case, a no city scenario and a larger and denser city as projected by the Houston-Galveston Area Council for 2045. During the daytime, cooling strategies such as cool roofs, cool roads, and green roofs exhibit superior performance in mitigating urban overheating. At night, enhanced urban irrigation emerges as the most effective cooling intervention. Cooling strategies significantly reduce sensible heat flux partitioning during the day, a process that reduces the uplift of air, suppressing the formation of urban shallow cumulus clouds. The extent of urban cloud mixing ratio is reduced in proportion to the decrease in sensible heating. Under the BEP-Tree scenario, which includes wind effects and evapotranspiration driven by a stomatal conductance model, urban trees demonstrated negligible environmental cooling effects and minimal urban cloud modifications. In contrast, the scenarios with more urban cooling and higher latent heat fluxes led to suppressed urban clouds. The net cooling effect achieved by the heat mitigation strategies is influenced by a combination of indirect processes, including the reduction of downwelling longwave radiation flux, due to reduced cloud presence, while some warming is attributed to a modest increase in shortwave radiation that offsets the cooling benefit. Additionally, reduced heat dissipation, weakened thermal gradients, and diminished vertical mixing over urban areas further moderate the cooling potential. These findings highlight the pivotal role of clouds and moist atmospheric processes in shaping the UHI effect and offer insights for designing more effective urban cooling strategies.

albedo changes

Comparison of wind farm control strategies under realistic offshore wind conditions: turbine quantities of interest

Abstract. Wind farm flow control is a strategy to increase the efficiency and therefore lower the levelized cost of energy of a wind farm. This is done using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the flow behind the turbine, affecting downstream turbines in the farm. Two inherently different wind farm flow control methods have been identified in the literature: wake steering and wake mixing. This paper focuses on comparing the turbine quantities of interest between these methods for a simple two-turbine wind farm setup, while a companion article (Brown et al., 2025) focuses on the wake quantities of interest for a single wind turbine setup. Both papers use the same set of wind farm simulations based on high-fidelity large-eddy simulations (LESs) coupled with OpenFAST turbine models. First, precursor simulations are executed in order to match wind conditions measured with lidars in an offshore wind farm off the east coast of the USA. These measurements show general wind conditions that exhibit substantially higher vertical wind shear and veer than any of the LES studies performed with wind farm flow control strategies currently available in the literature. The precursors are used to evaluate the effectiveness of the control methods. In the LES, the wind veer leads to highly skewed wakes, which have considerable influence on the power uplift of wind farm flow control strategies. In addition to a baseline controller, four different control strategies, each of which uses either pitch or yaw control, are performed on the upstream turbine of a simple two-turbine wind farm. Assuming that the wind direction is known and constant over time, the simulations show that wake steering is generally the superior wind farm flow control strategy, considering both wind farm power production and turbine damage equivalent loads when substantial wind veer is present. This result is consistent over different wind speeds and wind directions. On the other hand, for similar wind conditions with lower veer, wake mixing was found to yield the highest power production, although at the expense of generally higher loads. This leads us to conclude that the effect of wind veer, which has so far not usually been considered, can not be neglected when determining the optimal wind farm flow control strategy.

17 WIND ENERGY

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun

Development of Emergency Vehicle Preemption Strategies on Smart Corridors in a Digital Twin Environment

Emergency Response Vehicles (ERVs), such as firetrucks, ambulances, etc. operate with the purpose of saving lives and mitigating property damage. As such, ERV travel-time reductions may result in significant benefits to the community. A common strategy to improve travel times is Emergency Vehicle Preemption (EVP). EVP seeks to reduce ERV delays by providing the right-of-way to ERVs as they approach an intersection. This study proposes a new Dynamic Preemption strategy that determines the need for preemption prior to the ERV reaching the vicinity of the intersection, utilizing real-time data streams. This paper evaluates the effectiveness of some existing and proposed preempt control strategies using a digital twin testbed consisting of a series of signalized intersections on an urban arterial in Georgia. The best EVP strategy maximizes the improvement in ERV travel time while minimizing the adverse effect of preemption on the traffic in conflicting directions. Therefore, this study evaluates both the positive impact of EVP on the ERV as well as the adverse impact on the cross-street traffic. The study found that the potential exists for significant improvements in ERV travel time with the proposed Dynamic Preemption strategy, with minimal impact to the conflicting traffic. For the simulation corridor there was a 20% reduction in the ERV travel times with the implementation of the Dynamic Preemption strategy, compared to traditional EVP practices.

Roy, Somdut [Georgia Institute of Technology]

Studies of the influence of heat pipe model and coupling strategy in heat pipe microreactor simulations using Sockeye

This work demonstrates various modeling approaches for thermally coupling heat pipes to a graphite monolithic block in a microreactor context, accounting for the presence of a gap. We show that heat pipe model selection has a significant impact on the transient behavior of a three-dimensional coupled microreactor assembly problem by comparing results obtained using different heat pipe models from the heat pipe code Sockeye. Additionally, we show that the choice of coupling strategy has significant consequences for both accuracy and performance. Furthermore, we found that our heat flux transfer strategy exhibited greater accuracy than our temperature transfer strategy, even when comparing a loose coupling of the heat flux transfer strategy to a tight coupling of the temperature transfer strategy. Although this research uses only theoretical test problems, it provides important insights in modeling thermal fluids phenomena in heat pipe microreactors.

Direwolf

Optimal Control Strategy With Efficiency and Reliability Improvement for Offshore DC Microgrids

Offshore microgrids, due to their remote location and lack of external energy support, face significant challenges in wide-range load operation and maintenance. Consequently, efficiency and reliability are critical concerns for converters in offshore dc microgrids. This article presents an optimal control strategy aimed at enhancing both efficiency and reliability. A normalized nonlinear relationship between power loss and thermal stress of a paralleled converter is first established. Based on this, a dual-objective optimization function with an active weight function as well as a system overall performance index is established. The active weight function dynamically adjusts the control priority based on converter efficiency and switching device thermal stress. Then, the optimal power-sharing strategy is derived by the Lagrange multiplier method with the proposed optimal function. Additionally, to accommodate a wide load range, an optimal selection strategy for operating converter combinations is proposed, requiring only low-bandwidth communication. Experiment verification is given to validate the effectiveness of the proposed control strategy. The experiment results demonstrate that the proposed control strategy can improve the overall performance of offshore microgrids by optimizing efficiency and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION

Business Models for Scaling Demand Flexibility Volume II – Customer relationship management strategies, challenges, and lessons learned from U.S. programs

Load growth at the grid edge is driving increased attention to the distribution system and its ability to enable customer technology adoption in an affordable and timely manner. Key industry stakeholders, including electric utilities and regulators, can benefit from strategies to manage and balance customer needs with infrastructure investments, such as demand flexibility. This report focuses on demand flexibility—the ability to reduce, shift, shed, generate, or modulate loads in response to building and grid needs—to reduce the need for costly grid upgrades by deferring investment needs and increase system reliability by shifting electricity usage during periods of high risk. Specifically, we focus on the emerging characteristics of business models for demand flexibility as a framework to understand how demand flexibility programs generate value. In this report, we focus on demand flexibility program customer relationship management strategies, which provide information on value creation and focus on ensuring customers can navigate programs smoothly. This report discusses the role of customer relationship management strategies in demand flexibility programs, characterizes customer relationship management strategies that can be considered during program design and implementation, identifies existing challenges to customer relationship management strategies, and describes lessons learned. This report is part of a series that includes reports on value propositions, stakeholder ecosystem management, and program life cycle.

24 POWER TRANSMISSION AND DISTRIBUTION

Chasing Gamma-Ray Signals from Binary Neutron Star Coalescences with the Cherenkov Telescope Array: Prospects and Observing Strategies

The detection of gravitational waves (GWs) from a binary neutron star (BNS) merger by Advanced LIGO and Advanced Virgo (GW170817), together with its electromagnetic counterpart, the short gamma-ray burst GRB 170817A, heralded the birth of multimessenger astronomy. The detection of TeV emission from GRBs motivates follow-up observations with the Cherenkov Telescope Array Observatory (CTAO), which is ideal for detecting such signals due to its unprecedented sensitivity, rapid response, and wide-field survey capabilities. The aim of this work is to evaluate GeV–TeV GW follow-up strategies for CTAO using a multistep simulation pipeline and to estimate the expected rate of joint GW–GRB detections during observing run O5. Using a simulated sample of BNS systems with corresponding GW detections, gamma-ray emission is simulated through phenomenological prescriptions based on the observed population of short GRBs, including off-axis jet scenarios. CTAO observations are simulated to account for instrument response, sky tiling strategies, integration times, and varying observing conditions. Strategies with variable and constant integration times are investigated. We find that, via an optimized follow-up strategy, about 5% of simulated GW-associated short GRBs produce GeV–TeV radiation detectable by CTAO. Detectability is strongly influenced by the jet opening angle and viewing angle, suggesting that even rough estimates of the viewing angle in GW alerts could enhance targeting. This framework motivates future follow-ups of GW-detectable events, including neutron star–black hole mergers, and further supports the development of advanced strategies incorporating galaxy distributions and synergies with future detectors such as the Einstein Telescope.

Abe, S. [University of Tokyo] (ORCID:0000000172503