Search NASA⌕ Search

SEARCH · Search NASA

Results for “streetlights”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Kansas City, Missouri, Streetlight Electric Vehicle Charging: Strategies and challenges for site selection of streetlight electric vehicle infrastructure in Kansas City, Missouri (Final Report)

Public streetlight charging, whether on streets in central business districts or residential areas, provides easy charging access for apartment residents and homeowners alike. While most electric vehicle (EV) drivers charge at home, they do so in garages or on driveways they own. For renters and residents of multifamily housing (MFH), however, this may not be an option. EVs have a lower cost of ownership compared to conventional vehicles, and a used EV may be an affordable option for a lower-income household. But without easy access to charging, even a low-cost used EV may not be an option for a prospective buyer. An affordable curbside charging network has the potential to expand EV adoption into neighborhoods that have to date seen minimal interest and uptake of the technology and associated charging infrastructure. Streetlight charging networks can provide an economical, scalable, and effective approach to providing equitable and convenient charging. Metropolitan Energy Center (MEC) is dedicated to the mission of creating resource efficiency, environmental health, and economic vitality in the Kansas City region and beyond. Since 1983, MEC has provided resources, outreach, and training to make alternative fuels and energy efficiency commonplace. MEC led a streetlight charging pilot project that installed limited EV charging infrastructure on the streetlight system in Kansas City, Missouri, to demonstrate and test the benefits of curbside charging for EVs at existing on-street parking locations. The project aimed to cost-effectively expand the charging network in Kansas City to support residential charging and provide infrastructure in one or more charging deserts throughout the city. This pilot evaluates the impact and overall success of streetlight charging based on community feedback, utilization of charging infrastructure, technical feasibility, and cost. The project has pursued a data- and community-driven site selection process designed to identify sites with high demand and high opportunity for EV charging. This project was funded by the U.S. Department of Energy (DOE) and awarded to MEC through a competitive proposal process. The novelty and complexity of this project required an organization that could facilitate collaboration across levels of government, community members, and industry partners. For the past 25 years, through Kansas City Regional Clean Cities, MEC has worked with numerous public and private fleets on a variety of projects to improve the environmental performance and efficiency of the regional vehicle fleet. To advance affordable, efficient, and clean transportation efforts, DOE Clean Cities and Communities coalitions create local networks of public and private sector stakeholders and engage communities. Rooted within their local communities, the coalitions serve as experts and ambassadors, bringing to bear the collective knowledge, experience, and practical know-how of the entire network from within DOE, its national laboratories, and diverse stakeholders in the field. MEC and its project partners made in-kind contributions to leverage federal dollars for the benefit of the Kansas City community. Findings from this project will help determine the best applications for streetlight charging technologies to maximize funding impact and serve community needs. The team evaluated locations based on expected charging demand, technical feasibility, safety considerations, and enhanced charging network siting needs. Throughout the project, the team gathered feedback and evaluated ways to make public charging for EVs available to all community members. The insights will help Kansas City and other communities streamline future efforts to support EV drivers through public charging in the city right-of-way. Furthermore, this project will inform citywide guidance for future installations. MEC is committed to a transparent and publicly accessible approach that encourages the collaborative evaluation of streetlight charging. The project has engaged the community to proactively identify and evaluate the benefits and impacts of streetlight charging. It was a priority for the project to ensure the benefits of this pilot are distributed equitably to all members of the Kansas City community and that new charging opportunities and associated resources are available in diverse neighborhoods across the city. The charging infrastructure supports an affordable curbside charging network that will enable more drivers to choose EVs and provide easy charging access for all community members interested in driving an EV. The community feedback received through this project informed future resources and opportunities to make EVs more accessible to all members of the Kansas City community. MEC worked with several community partners on this project, including Missouri University of Science and Technology (MST), Pennsylvania State University (Penn State), the National Renewable Energy Laboratory (NREL); the city of Kansas City, Missouri; Evergy; Black and McDonald (B&M); LilyPad EV; EVNoire; and Westside Housing Organization (WHO). Project partners contributed to the cost match required for DOE grants through capital expenditures, personnel, and other in-kind contributions. Detailed descriptions of project team organizations can be found in Appendix A. Project Partners. Analysts at NREL and MST/PennState developed site maps based on demand and equity considerations. MEC conducted outreach to community members to garner input on project design and site selection, and received approval from the Missouri Public Service Commission (PSC) for Evergy’s EV charging station ownership. MEC worked with all partners to gather additional siting criteria and developed a site selection evaluation checklist, and partners conducted site visits to proposed installation sites. Next, B&M, Evergy, and the city executed all site agreements, conducted site-specific engineering design, acquired associated permits, and issued notices to proceed site by site or in small batches. Finally, from January to April 2023, the project team installed 23 EV charging stations built on Kansas City’s streetlight system in six council districts. Evergy will own, operate, and monitor the stations for 10 years, sharing charging data with MEC for at least 1 year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Equitable Urban Electric Vehicle Charging: Feasibility and Benefits of Streetlight Charging in Kansas City Right-of-Way

With an increasing global emphasis on sustainability, electric vehicles (EVs) play a crucial role in reducing urban pollution and carbon emissions. For EVs to be widely adopted, equitable and convenient access to charging infrastructure is essential. Equity in this paper refers to the proactive engagement with the community to ensure that the benefits of streetlight charging are distributed equitably across diverse neighborhoods in Kansas City, providing fair charging opportunities and resources to all community members. This research explores the potential of utilizing streetlights—ubiquitous elements of urban electrical infrastructure—as low-cost, equitable EV charging solutions. Compared with conventional chargers, streetlight charging offers several notable advantages, including proximity to roadways, potential boosts to the local economy, and easier usage due to city ownership. These chargers also leverage existing power setups to minimize costs and maximize efficiency by reutilizing existing structures. In this manuscript, we introduce a systematic framework to develop, analyze, and evaluate a scalable and cost-effective streetlight charging solution. Initially, we employ a two-tiered site selection framework that accounts for both charging demand and equity considerations to identify optimal locations for streetlight chargers. We then assess the feasibility of these chargers through observational data from 23 units installed in Kansas City, Missouri, comparing their performance with traditional chargers. Here, our evaluation extends to the environmental impact, comparing reduced gasoline consumption and greenhouse gas (GHG) emission reductions between streetlights and regular charging stations. Our findings reveal that streetlight charging stations offer faster charging speeds than conventional stations, validating their viability for EV charging. Additionally, the duration of stay at streetlight chargers tends to be shorter, likely due to parking constraints or associated costs. Furthermore, streetlight-powered chargers demonstrate considerable environmental advantages, achieving 11.94% greater avoided gasoline consumption and 11.24% higher GHG reductions compared with regular charging stations, highlighting their substantial environmental benefits.

42 ENGINEERING↗

Hanover LED Streetlight Conversion

On May 8, 2017, Hanover residents voted overwhelmingly to transition to 100% renewable electricity by 2030 and heating, cooling and transportation by 2050. In so doing, we became the first municipality in the country to make this commitment by popular vote. To accomplish these goal town leaders developed a plan to address first transitioning municipal energy uses to renewable forms of energy, through on-site generation of the municipal electrical load, load reduction through energy efficiency improvements to town facilities and infrastructure. Significant progress has been accomplished in the generation of energy with 90%+ of the 2024 municipal load being offset by generation and through various energy efficiency projects. The utility owned street lighting was identified as a large energy consumer of 165 MWh annually (7% of the annual municipal load) due to old inefficient high-pressure sodium and mercury vapor streetlights with no ability to reduce wattage during periods with low lighting needs. The Hanover LED Streetlight Replacement Project replaced utility owned streetlights with town owned controllable (dimmable and trimmable) LED lights that can be adjusted by location and time of night. Coupled with ownership of the streetlights transfer to the town, the town’s share of the project pay back is 11 months and for the complete project including federal share the payback is approximately 3 years. With the completion of lighting upgrade, the annual streetlighting energy load has dropped by 60% to 67 MWh in the first year of operation (7/1/24 - 6/30/25). This amounts to an approximate $90,000 annual savings or a local 1% tax rate impact. Additionally, over 200,000 pounds of CO2 will be saved annually.

99 GENERAL AND MISCELLANEOUS↗

The Energy and Operational Impacts of Using 0-10V Control for LED Streetlights

Lighting systems have historically utilized either a proprietary control method, or one of a handful of standardized methods (e.g., 0-10V, DALI, DMX512) aimed at facilitating vendor interoperability. The utility and market success of the standardized methods has been limited for a variety of reasons. Although 0-10V is presently the most commonly available control interface for indoor and outdoor products in North America – even after the emergence of LED products and “connected lighting systems” with more modern network interfaces and luminaire-level sensors and intelligence – the use of 0-10V methods has significant tradeoffs. For instance, it is difficult to predict relative luminaire light output and input power at any particular control voltage, and performance across luminaires is inconsistent. This study characterizes 23 LED streetlights that claimed dimmability via a 0-10V interface, quantifies the performance variation found in market-available LED drivers, and explores the potential impact of the most recent 0-10V voluntary standard (ANSI C137.1-2022). Notably, the tested products were all manufactured prior to the release of this standard, and thus do not make compliance claims. Variation in response to 0-10V control voltages was expected to be more significant across different make/model luminaires than different units of the same make/model; the test population was structured based on this expectation. The 23 tested luminaires comprised 21 unique make/model streetlights from 14 different manufacturers. Three samples of one make/model streetlight were included in the test population to facilitate a limited exploration of unit-to-unit variation. The 21 unique make/model luminaires contained 20 unique make/model LED drivers from eight different driver manufacturers. Luminaire input power and current were measured at 11 control voltages (0.5 V and 1–10 V in 1 V increments).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Energy and Operational Impacts of Using 0-10V Control for LED Streetlights

LED lighting is becoming widely adopted and displacing most traditional lighting technologies. However, the traditional methods used to control light sources have not seen similar displacement. Lighting systems have historically utilized either a proprietary control method, or one of a handful of standardized methods (e.g., 0-10V, DALI, DMX512). The utility and market success of the standardized methods has been limited for a variety of reasons. Analog 0-10V methods have long been popular due to their simplicity and low cost of implementation and are presently the most commonly available control interface for indoor and outdoor LED products in North America. The emergence of “connected lighting systems” with more modern network interfaces and luminaire-level sensors and intelligence was anticipated by many to mark the beginning of the end of analog control. However, 0-10V interfaces continue to be prevalent with these more “digital” systems. The use of 0-10V methods has significant tradeoffs. 0-10V standards have historically not explicitly defined the relationship between the luminaire input control signal and output luminous flux for the full control signal range. As a result, it is difficult to predict relative luminaire light output and input power at any particular control voltage, and in practice the performance across LED drivers and the luminaires power is inconsistent. While this inconsistency has long been acknowledged by experts in the field, it is not accounted for in standard practice deployment, and end-users continue to regularly see unexpected and undesirable performance. It is hoped that the results from this study will help the lighting industry and standards developing organizations better understand and possibly resolve the shortcomings of 0-10V products, and consider what is best for the industry – additional incremental improvements to this fundamentally limited analog technology, or fully moving on to existing digital approaches, such as DALI D4i, that deliver accurate and consistent dimming performance across all luminaires in the system and thus guarantee the delivery of expected light levels, and energy and cost savings. Recommendations consistent with these goals are made to lighting and driver manufacturers, lighting software developers, standard developing organizations, and system designers and specifiers.

0-10V↗

Direct measurement of the contribution of street lighting to satellite observations of nighttime light emissions from urban areas

Nighttime light emissions are increasing in most countries worldwide, but which types of lighting are responsible for the increase remains unknown. Also unknown is what fraction of outdoor light emissions and associated energy use are due to public light sources (i.e. streetlights) or various types of private light sources (e.g. advertising). Here we show that it is possible to measure the contribution of street lighting to nighttime satellite imagery using ‘smart city’ lighting infrastructure. The city of Tucson, USA, intentionally altered its streetlight output over 10 days, and we examined the change in emissions observed by satellite. We find that streetlights operated by the city are responsible for only 13% of the total radiance (in the 500–900 nm band) observed from Tucson from space after midnight (95% confidence interval 10–16%). If Tucson did not dim their streetlights after midnight, the contribution would be 18% (95% confidence interval 15–23%). When streetlights operated by other actors are included, the best estimates rise to 16% and 21%, respectively. Existing energy and lighting policy related to the sustainability of outdoor light use has mainly focused on street lighting. These results suggest an urgent need for consideration of other types of light sources in outdoor lighting policy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Street Lighting: Highland Park Pathways to Power [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "A" related to the city's streetlights. Due to economic collapse, the City of Highland Park negotiated repossession of it's neighborhood streetlights to help pay its debt to its power provider, DTE. Without street lighting on residential streets, public safety was at risk. Local community-based-organization, Soulardarity, began installing off-grid solar street lights to improve visibility for vehicles and pedestrians in Highland Parks neighborhoods. Residents and leaders of the community who served on the Communities LEAP Coalition requested NREL review a financial model Soulardarity proposed to operate a city-wide solar streetlighting program on the City's behalf. The coalition also requested NREL identify examples of similar implemented city-wide solar street lighting programs.

14 SOLAR ENERGY↗

A User-Facing Metric to Quantify the Quality of Mobility (CRADA Final Report)

The leading urban mobility data analytics firm StreetLight Data, Inc. partnered with the National Renewable Energy Laboratory to explore a commercial version of the Mobility Energy Productivity (MEP) metric. The commercialization effort was aimed to expand the adoption of the metric to key stakeholders in the urban planning space. Research comprised industry analysis, stakeholder feedback and conducting transportation practitioner focus groups. StreetLight concluded that commercialization of MEP is not feasible in the current market because users need a dynamic MEP tool that enables scenario planning. It should be able to calculate a MEP score dynamically (near instantaneous) when different inputs are changed.

33 ADVANCED PROPULSION SYSTEMS↗

Outdoor Lighting Challenges and Solution Pathways

This document describes outdoor lighting solutions that municipalities are adopting to help create a safe environment for residents and business owners. The report describes the accelerated market adoption of LED streetlights.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial Results of Accelerated Stress Testing on Single-Channel and Multichannel Drivers: Solid-State Lighting Technology Area

This report is the first in a series of studies on accelerated stress testing (AST) of drivers used for SSL luminaires, such as downlights, troffers, and streetlights. A representative group of two-stage commercial driver products was exposed to an AST environment consisting of 75°C and 75% relative humidity (7575). These drivers were a mix of single-channel drivers (i.e., a single output current for one LED primary) and multichannel drivers (i.e., separate output currents for multiple LED primaries). This AST environment was chosen because previous testing on downlights with integrated drivers demonstrated that 38% of the sample population failed in less than 2,500 hours of testing using this method. In addition to AST test results, the performance of an SSL downlight product incorporating an integrated, multichannel driver during extended room temperature operational life (RTOL) testing is also reported. A battery of measurements was used to evaluate these products during accelerated testing, including full electrical characterization (i.e., power consumption, PF, total harmonic distortion [THD], and inrush current) and photometric characterization of external LED loads attached to the drivers (i.e., flicker performance and lumen maintenance).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wyandotte Integrated Renewable Energy Strategy (WIRES 2) (Final Technical Report)

Wyandotte Municipal Services (WMS), a Michigan Municipal Utility offering electric generation, transmission & distribution, water filtration & distribution and Broadband/Video sought to deploy a set of renewable energy projects for their Electric Utility that contributed to reducing the City’s environmental and energy impact, provided examples that would encourage businesses and citizens to adopt cleaner energy practices and help WMS meet the required renewable energy standards of the State of Michigan (10% in 2015, 15% in 2021). WMS generates and delivers roughly 280,000 megawatt hours (MWh) of electricity annually to more than 10,000 homes and 1,000 businesses within the City of Wyandotte. The Wyandotte Integrated Renewable Energy Strategy – WIRES 2 resulted in deployment of a set of community-scale micro-wind turbines, evaluation and installation of energy-efficient and low-maintenance light-emitting diode (LED) street lights and park lights in highly visible locations in the City and expansion of the geothermal heating and cooling district that already included residential geothermal systems, to include larger scale business/institutional systems at the Utility’s largest electric customer and at the City Library. Finally, WMS identified the need for job training in energy efficiency and renewable energy technologies to further develop a local skilled workforce in these areas. Partially funded by the grant, the wind turbine project provides a benchmark for WMS, local businesses and residents in the evaluation of utility-scale wind v. micro-wind in an urban environment as a renewable energy strategy. Also partially funded by the grant, the LED project benefited the City of Wyandotte by reducing load on the electric system for the public utility but also reduced City costs for streetlighting, parking lot lighting and park lighting without a compromise in security. The project also resulted in a visual success that has led to additional approvals for non-Grant related LED lighting installations resulting in further reduction in the electric load in the City. Commercial Geothermal installations resulted in the Utility being able to eliminate steam customers who formerly utilized the byproduct of steam from WMS electric production. Due to the reduction in natural gas prices and the overall reduction in market purchased power, it was no longer feasible for WMS to operate its Power Plant as a base load plant and to only operate on a market dispatch philosophy when market prices dictated that WMS could produce electricity cheaper than the market purchase price. This has resulted in fewer operating days for the WMS Power Plant, resulting in less environmental impact. WMS has now completely exited the steam business and the ability to offer a geothermal option to two (2) former steam customers (BASF-Wyandotte and the Bacon Memorial Library) allowed for that. In addition, peak loads have been shaved for these two (2) large customers due to the consistent temperature offered by geothermal heating and cooling, reducing the swings associated with thermostat changes caused by outside temperature changes during extreme high and low temperatures. Finally, energy efficiency and renewable energy college-level classes at Wayne County Community College allowed a group of interested students to pursue studies in those technologies through grant provided tuition, books and course materials. This effort provided a foundation of potential future employees not only for WMS but other energy efficiency/renewable energy employers such as Franklin Energy, a partner with WMS in energy optimization efforts with Wyandotte businesses.

17 WIND ENERGY↗

The Outdoor Lighting Accelerator: Lighting the Way Forward (Final Report)

This final report outlines the work performed by DOE’s Better Buildings Outdoor Lighting Accelerator, through which cities, states, and regional groups explored best practice approaches to improve the way communities apply advanced outdoor lighting technologies in parking lots and highways. It describes the related work of participants, including designing regional bonding authorities or joint purchasing programs, financing streetlight upgrades, and more.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adopting Energy-Efficient Technologies for Street Lighting: Overcoming Challenges for Utilities

This brief discusses energy-efficient street lighting technologies and conversions from the utility’s perspective and identifies various business cases for undertaking street lighting upgrades. Section 1 of the brief reviews the costs and benefits of utility investment in energy efficiency technologies and smart infrastructure for utility-owned streetlights. Section 2 presents lessons learned and best practices for light-emitting diode (LED) conversions for utility-owned street lights. Section 3 discusses street light buyback options from the utility’s perspective. Section 4 reviews success factors for LED conversions. The resources listed at the end of the brief provide more information.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Cybersecurity Threat Profile for a Connected Lighting System

In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement.

97 MATHEMATICS AND COMPUTING↗

A Cybersecurity Threat Profile for a Connected Lighting System

In anticipation of improved energy performance and cost savings, cities and building owners are increasingly considering “smart lighting initiatives” that aim to convert their collection of simple luminaires (i.e., lighting fixtures) into an intelligent connected lighting system (CLS) capable of remotely monitoring energy consumption and fault conditions, and possibly implementing adaptive lighting schemes. The U.S. Department of Energy (DOE) has set an national goal of tripling the energy efficiency and demand flexibility of the buildings sector by 2030, relative to 2020 levels 1. It is forecast that connected lighting systems can contribute to that goal by delivering 125 TWh of annual energy savings by 2035 2, equivalent to the annual output of 50 typical (500 MW) power plants. However, these energy savings and the DOE goal are put at significant risk if connected technologies are not adopted due to real or perceived cybersecurity concerns. Connected IoT devices such as these have historically been rife with vulnerabilities which sometimes put security considerations secondary to functionality and operability. What are the cybersecurity threats that will impact these systems, as formerly banal luminaires transition into intelligent connected devices that collect information about themselves, their surrounding environment, and possibly us? In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement. Fifty-seven threats were identified. Among our key findings: (1) 65% (37/57) of the threats did not involve the luminaires, but rather the other components needed to communicate with and manage them; (2) 63% (36/57) of the threats could have been mitigated through manufacturer-implemented defensive techniques or “controls”; and (3) 23% (13/57) of the threats were dependent on the network configuration. Recommendations based on the results of this work are made to key stakeholder groups. Notably, lighting technology developers are advised to address all threats that can be reasonably controlled with baked-in technology solutions (e.g., encryption or authentication controls), and employ some form of secure supply chain management and tracking where other parts (e.g., sensors, microprocessors) of a luminaire must also be built and manufactured with the proper security controls in place. Developers should also review threats involving assets not developed in-house to understand how connectivity with other devices will affect their product during system operation and determine if a compensating control for a defense-in-depth strategy will be needed. Finally, those interested in deploying CLS should compare the differences between cloud and on-premise models to determine which is more suitable for their needs and the abilities of their security team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗