Search NASASearch

SEARCH · Search NASA

Results for “stroboscopic sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Stroboscopic x-ray diffraction microscopy of dynamic strain in diamond thin-film bulk acoustic resonators for quantum control of nitrogen-vacancy centers

Bulk-mode acoustic waves in a crystalline material exert lattice strain through the thickness of the sample, which couples to the spin Hamiltonian of defect-based qubits such as the nitrogen-vacancy (N-V) center defect in diamond. This mechanism has previously been harnessed for unconventional quantum spin control, spin decoherence protection, and quantum sensing. Bulk-mode acoustic wave devices are also important in the microelectronics industry as microwave filters. A key challenge in both applications is a lack of appropriate operando microscopy tools for quantifying and visualizing gigahertz-frequency dynamic strain. Here, in this work, we directly image acoustic strain within N-V center-coupled diamond thin-film bulk acoustic wave resonators using stroboscopic scanning hard x-ray diffraction microscopy at the Advanced Photon Source. The far-field scattering patterns of the nanofocused x-ray diffraction encode strain information entirely through the illuminated thickness of the resonator. These patterns have a real-space spatial variation that is consistent with the bulk strain’s expected modal distribution and a momentum-space angular variation from which the strain amplitude can be quantitatively deduced. We also perform optical measurements of strain-driven Rabi precession of of the N-V center spin ensemble, providing an additional quantitative measurement of the strain amplitude. As a result, we directly measure one of the six N-V spin-stress coupling parameters, 𝑏 =2.73⁢(2) MHz/GPa, by correlating these measurements at the same spatial position and applied microwave power. Our results demonstrate a unique technique for directly imaging ac lattice strain in micromechanical structures and provide a direct measurement of a fundamental constant for the N-V center defect spin Hamiltonian.

acoustic techniques

Extreme Longitudinal Compression of Optimized Beams for MEV Ultrafast Electron Diffraction (Final Technical Report)

We worked out the design of a high repetition rate MeV energy ultrafast electron diffraction instrument based on the existing Cornell photoinjector, which can readily be applied to the presented findings. This example is a blueprint of other similarly arranged UED setups. Using particle tracking simulations in conjunction with multiobjective genetic algorithm optimization, we explored the smallest bunch lengths, emittance, and probe spot sizes achievable. As two limits, we defined stroboscopic conditions (with single electrons per pulse) and operation with 10 5 electrons per bunch which may be suitable for single-shot diffraction images. In the stroboscopic case, the flexibility provided by the many cavity bunching and acceleration allows for longitudinal phase space linearization without a higher harmonic field, providing sub-fs bunch lengths at the sample. Given low emittance photoemission conditions, these small bunch lengths can be maintained with probe transverse sizes at the single micron (1 μm) scale and below. In the case of 10 5 electrons per pulse, we simulated state-of-the-art 5D brightness conditions: rms bunch lengths of 10 fs with 3-nm normalized emittances, while permitting repetition rates as high as 1.3 GHz. We showed that in conjunction with collimating apertures, a novel focusing scheme achieves very high-quality emittance compensation for the central core of the beam composing 40% of particles, for a resulting beam size of 5 μm (rms). Finally, to aid in the design of new SRF-based ultrafast electron diffraction machines, we simulated the trade-off between the number of cavities used and achievable bunch length and emittance. In the longitudinal dimension, we made use of the fact that MeV UED requires much lower energy than the 15-MeV maxi mum energy of Cornell’s CBETA injector, and we may therefore use several of the SRF cavities for bunch length compression. In practice, we used a genetic optimization algorithm to choose the phases and amplitudes of the cavities appropriately for optimal bunching. In the zero space charge case, we found that bunching and acceleration are distributed across the six cavities in a way that produces a linearizing effect. And we showed that the ultimate bunch length can be limited by time-of-flight differences arising from transverse size and transverse momentum spread. The space charge code developed and used for this development is now permanent part of the Bmad accelerator simulation code and has already contributed to other developments, e.g., for the EIC electron cooler design.

43 PARTICLE ACCELERATORS

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Single-shot imaging with randomized structured illumination at a free electron laser

Stroboscopic nanoscale imaging with free electron laser light is revolutionizing our understanding of fast dynamics in heterogeneous systems. The short wavelength of X-ray and extreme ultraviolet radiation makes it possible to achieve nanoscale resolution, while resonance with atomic transitions gives access to electronic and magnetic degrees of freedom. Here, we report on our implementation of a recently developed imaging method, randomized probe imaging, at a free electron laser. The advantage of randomized probe imaging over existing methods is its compatibility with extended and strongly scattering samples. Our implementation delivers robust single-shot reconstructions at up to a full-pitch resolution of 400 nm over a field of view with a 40 µm diameter. We also demonstrate single-shot imaging of magnetic domain structures using circular dichroism at resonance, paving the way to future time-resolved studies of magnetic dynamics, shock physics, and the dynamics of collective electronic phases.

47 OTHER INSTRUMENTATION

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy