Search NASA⌕ Search

SEARCH · Search NASA

Results for “sub meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Deep-learning-based canopy height model generation from sub-meter resolution panchromatic satellite imagery

Canopy height models (CHMs) with sufficient resolution to distinguish individual trees are useful for a variety of applications. However, standard techniques to acquire such data, such as airborne lidar surveying, are often prohibitively expensive. Deep learning techniques for generating CHMs from high-resolution imagery are an attractive option to reduce costs. To date, success with these methods has been demonstrated using multichannel aerial photography and specialized satellite data products derived from multiple sensors, neither of which is commonly available at temporal resolutions finer than one year. Here we demonstrate a method to generate sub-meter resolution CHMs in three forests in California using a more abundant data source: sub-meter resolution, panchromatic satellite imagery from a single sensor. We show that phenology and species composition play important roles in model transferability; when trained using imagery from a single conifer forest in autumn, the model performs well on autumn imagery from a second conifer forest several hundred kilometers distant with no re-training. With modest additions to the training dataset, the same model generates minimally biased estimates of canopy height in both conifer and deciduous forests during multiple seasons. Because the model operates on satellite data with global coverage and a relatively short return interval, we propose its suitability to extrapolate tree-level canopy height data to remote regions and conduct high-temporal resolution monitoring of forest structure. We furthermore demonstrate the workflow’s applicability to fire modeling by conducting simulations in forests populated by trees measured using both this approach and airborne lidar surveying. We find minimal differences in fire behavior relative to a baseline case in which only statistical distributions of tree height and crown area are known. This result underscores the value of forest structural information derived from our workflow for improving the fidelity of wildland fire simulations, among other ecological applications.

54 ENVIRONMENTAL SCIENCES↗

The importance of sub-meter-scale snow roughness on conductive heat flux of Arctic sea ice

Abstract The conductive heat flux through the snow and ice is a critical component of the mass and energy budgets in the Arctic sea ice system. We use high horizontal resolution (3–15 cm) measurements of snow topography to explore the impacts of sub-meter-scale snow surface roughness on heat flux as simulated by the Finite Element method. Simulating horizontal heat flux in a variable snow cover modestly increases the total simulated heat flux. With horizontal heat flux, as opposed to simple 1D-vertical heat flux modeling, the simulated heat flux is 10% greater than that for uniform snow with the same mean snow thickness for a 31.5 × 21 m region of sea ice (the largest region we studied). Vertical-only (1D) heat flux simulates just a 6% increase for the same region. However, this is highly dependent on observation resolution. Had we measured the snow cover at 1 m horizontal spacing or greater, simulating horizontal heat flux would not have changed the net heat flux from that simulated with vertical-only heat flux. These findings suggest that measuring and modeling snow roughness at sub-meter horizontal scales may be necessary to accurately represent horizontal heat flux on level Arctic sea ice.

Geology↗

FTR for: Reducing plug-load electricity footprint of residential buildings through low-cost, non-intrusive sub-metering and personalized feedback technology

The project started in October 2016 and ended in December 2022. The project's principal goals and achievements were: (i) Measure real and reactive electric power consumption in ~400 apartments in multifamily settings of varying size and vintage and publish the data; data was published according to New York State's recommended 15x15 rule continuously from Jan 2019 through December 2022 (10 second time resolution); with the combination of large number of apartments, real and reactive power, as well as high time resolution (10-seconds), the dataset is first of its kind worldwide; because the dataset New York City apartment consumption pre, during, and post pandemic, it further offers unique insights into changes in residential electricity consumption during lockdowns and after modified work from home schedules. (ii) Measure effectiveness of different feedback types to prompt residents to lower their electricity consumption; achieved 11% (kWh-weighted) reduction versus baseline consumption; confirmed previous studies that social comparisons elicit above average responses; showed, for the first time, that the so called boomerang effect in power consumption feedback projects can be explained by a previously hypothesized norm-conforming "magnet effect" (rather than a non-conforming defiance effect), thus substantially advancing the research in the field. (iii) Disaggregate apartment-level consumption to appliance level; because the hardware for electricity consumption unexpectedly allowed only for 10-second time resolution (rather than the 1-second resolution we had planned on), the disaggregation algorithms we developed on sample data could not be applied to the actual field data we collected. The project has yielded high visibility, with a total of 17 publications, from peer reviewed journals, published data sets (free access), blog posts, NY Times, National Public Radio, and CNN.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Modified Sequence-to-point HVAC Load Disaggregation Algorithm

This paper presents a modified sequence-to-point (S2P) algorithm for disaggregating the heat, ventilation, and air conditioning (HVAC) load from the total building electricity consumption. The original S2P model is convolutional neural network (CNN) based, which uses load profiles as inputs. We propose three modifications. First, the input convolution layer is changed from 1D to 2D so that normalized temperature profiles are also used inputs to the S2P model. Second, a drop-out layer is added to improve adaptability and generalizability so that the model trained in one area can be transferred to other geographical areas without labelled HVAC data. Third, a fine-tuning process is proposed for areas with a small amount of labelled HVAC data so that the pre-trained S2P model can be fine-tuned to achieve higher disaggregation accuracy (i.e., better transferability) in other areas. The model is first trained and tested using smart meter and sub-metered HVAC data collected in Austin, Texas. Then, the trained model is tested on two other areas: Boulder, Colorado and San Diego, California. Simulation results show that the proposed modified S2P algorithm outperforms the original S2P model and the support-vector machine based approach in accuracy, adaptability, and transferability.

Ye, Kai↗

An ICA-Based HVAC Load Disaggregation Method Using Smart Meter Data

This paper presents an independent component analysis (ICA) based unsupervised-learning method for heat, ventilation, and air-conditioning (HVAC) load disaggregation using row-resolution (i.e., 15 minutes) smart meter data. We first demonstrate that the electricity consumption profiles on mild-temperature days can be used to approximate the base load on hot days. A residual load profile can then be calculated by subtracting the mild-day load profile from the hot-day load profile. The residual load profiles are processed using ICA for HVAC load extraction. An optimization-based algorithm is proposed for post-adjustment of the ICA results, considering two bounding factors for enhancing the robustness of the ICA algorithm. First, we use the hourly HVAC energy bounds computed from the relationship between HVAC load and temperature to remove unrealistic HVAC load spikes. Second, we exploit the dependency between the daily nocturnal and diurnal loads extracted from historical meter data to smooth the base load profile. Pecan Street data with sub-metered HVAC data were used to test and verify the proposed methods. Simulation results demonstrated that the proposed method is computationally efficient and robust across multiple customers.

Kim, Hyeonjin↗

Wattile: Probabilistic Deep Learning-based Forecasting of Building Energy Consumption [SWR-20-94]

Accurate energy forecasting is becoming critical due to many reasons: i ) optimal distributed energy resources operations and dispatch, ii) fault detection and diagnostics, and iii) meeting operational energy efficiency targets. Wattile uses deep learning (DL) for the building's short-term load forecasting application. Two specific types of neural networks called, Long Short Term Memory (LSTM) and Sequence-to-Sequence (S2S) models are used to make predictions. Forecasting models are trained using online historical weather and occupancy indicator data streams from the Intelligent Campus Program's data acquisition systems at the National Renewable Energy Laboratory (NREL) for main meters and sub-meters of multiple building types. These models use probabilistic methods to provide quantile-based forecasts in addition to nominal conditional median predictions of electricity consumption.

Frank, Stephen↗

Peering into cloud physics using ultra-fine resolution radar and lidar systems

Cloud microphysical processes, such as droplet activation, condensational growth, and collisional growth, play a central role in the evolution of clouds and precipitation. Accurate representations of these processes in numerical models are challenging partially due to incomplete understanding of them at the process-level arising from limited systematic observations. Most surface-based active remote sensors, including today’s operational cloud radars and lidars, have a resolution on the order of tens of meters. This resolution is insufficient to resolve cloud microphysical processes that manifest at finer (meter and sub-meter) scales. A new set of ultra-high-resolution ground-based radar and lidar systems have been developed to address this observational gap. The newly developed 94-GHz cloud radar has a range resolution down to 2.8 m, or a factor of 10 finer than typical radars, using a large bandwidth and quadratic phase coding techniques. The lidar has a range resolution down to 10 cm, or a factor of 100 finer than typical lidars, using a time-gated time-correlated single photon counting technique. Such high-resolution observations were previously only achievable through in situ aircraft measurements. Even then, aircraft measurements do not permit continuous long-term cloud observation as is possible with ground-based remote sensing instruments. In this study, the first-light cloud observations from the new radar and lidar systems are shown to reveal detailed cloud structures that conventional sensors could only perceive in a bulk sense, thus providing new avenues to investigate cloud microphysical processes and their impact on weather and climate.

54 ENVIRONMENTAL SCIENCES↗

Reviews and syntheses: Variable inundation across Earth's terrestrial ecosystems

Abstract. The structure, function, and dynamics of Earth's terrestrial ecosystems are profoundly influenced by how often (frequency) and how long (duration) they are inundated with water. A diverse array of natural and human-engineered systems experience temporally variable inundation whereby they fluctuate between inundated and non-inundated states. Variable inundation spans extreme events to predictable sub-daily cycles. Variably inundated ecosystems (VIEs) include hillslopes, non-perennial streams, wetlands, floodplains, temporary ponds, tidal systems, storm-impacted coastal zones, and human-engineered systems. VIEs are diverse in terms of inundation regimes, water chemistry and flow velocity, soil and sediment properties, vegetation, and many other properties. The spatial and temporal scales of variable inundation are vast, ranging from sub-meter to whole landscapes and from sub-hourly to multi-decadal. The broad range of system types and scales makes it challenging to predict the hydrology, biogeochemistry, ecology, and physical evolution of VIEs. Despite all experiencing the loss and gain of an overlying water column, VIEs are rarely considered together in conceptual, theoretical, modeling, or measurement frameworks and approaches. Studying VIEs together has the potential to generate mechanistic understanding that is transferable across a much broader range of environmental conditions, relative to knowledge generated by studying any one VIE type. We postulate that enhanced transferability will be important for predicting changes in VIE function in response to global change. Here we aim to catalyze cross-VIE science that studies drivers and impacts of variable inundation across Earth's VIEs. To this end, we complement expert mini-reviews of eight major VIE systems with overviews of VIE-relevant methods and challenges associated with scale. We conclude with perspectives on how cross-VIE science can derive transferable understanding via unifying conceptual models in which the impacts of variable inundation are studied across multi-dimensional environmental space.

54 ENVIRONMENTAL SCIENCES↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensor-based phenology from snowmelt experiment gradient, East River, Colorado, 2017 to 2020

The timing of snowmelt is a critical cue for the initiation of growth in mountain meadow ecosystems and can also impact the duration and magnitude of plant production. High frequency observations of species-level phenology are time consuming and require a high degree of expertise, and publicly available remote sensing products lack the necessary temporal resolution to assess fine-scale growing season dynamics. Near-surface sensing methods provide a middle ground with high temporal frequency and tractable spatial scales (from sub-meter to hillslope scale). This data package includes csv files of Normalized Difference Vegetation Index (NDVI) timeseries (SM_NDVI_dailymax.csv) and phenological thresholds (SM_NDVI_summary.csv) for sub-plots (1m2) and Green Chromatic Coordinate (GCC) phenological thresholds (SM_GCC_summary.csv) at the plot scale (10m x 14m). Location IDs associated with this data package are: ER-LM, WG-UM, WG-LS, ER-US, and XX-AL. Related data packages include: “Microclimate observations associated with snowmelt experiment gradient sites, East River, Colorado, 2017 to 2020” and “Colorado Elevation Gradient Snowmelt Manipulation Plant Phenology 2017-2018”.

54 ENVIRONMENTAL SCIENCES↗

High-resolution mapping of spatial heterogeneity in ice wedge polygon geomorphology near Prudhoe Bay, Alaska

It is well known that microtopography associated with ice wedge polygons drives pronounced, meter-scale spatial gradients in hydrologic and ecological processes on the tundra. However, highresolution maps of polygonal geomorphology are rarely available, due to the complexity and subtlety of ice wedge polygon relief at landscape scales. Here we present a sub-meter resolution map of >106 discrete ice wedge polygons across a ~1200 km2 landscape, delineated within a lidar-derived digital elevation model. The delineation procedure relies on a convolutional neural network paired with a set of common image processing operations and permits explicit measurement of relative elevation at the center of each ice wedge polygon. The resulting map visualizes meter- to kilometer-scale spatial gradients in polygonal geomorphology across an extensive landscape with unprecedented detail. This high-resolution inventory of polygonal geomorphology provides rich spatial context for extrapolating observations of environmental processes across the landscape. The map also represents an extensive baseline dataset for quantifying contemporary land surface deformation (i.e., thermokarst) at the survey area, through future topographic surveys.

54 ENVIRONMENTAL SCIENCES↗

Dataset of U.S. School Bus Depots

A large body of public health literature describes how undesirable or dangerous facilities, such as truck depots and industrial plants, located in or near communities can lead to health harms. Research also describes the high levels of traffic-related air and noise pollution that is linked to health harms and may be disproportionately distributed near many schools. Therefore, a primary use case for this dataset is to analyze the location of school bus depots and to create an evidence base that would better enable the work of community members, advocates, and other stakeholders toward improving air quality and public health. Other possible uses for this school bus depot dataset include electricity grid planning and reliability, given recent momentum toward school bus electrification. This dataset was created using an object-based approach with remote sensing data. The primary source of aerial imagery was the National Agriculture Imagery Program (NAIP) dataset. NAIP imagery was analyzed to locate individual school buses based on their color and size, and then classified clusters of school buses as potential depots, which were then verified visually. The resulting dataset contains 11,309 depots across the 48 contiguous U.S. states and Washington, D.C. Fifty-one percent (5,730 depots) are at schools, defined as being 350 meters or less from the nearest school. The accuracy of the dataset was assessed by comparing it with independent reference datasets containing 506 depots from the records of two school transportation companies. We found good agreement, with an omission error rate of 15.2% (77 depots). This dataset represents one of the only remote sensing projects to conduct object detection using data at the sub-meter to 1-meter resolution for a continental-scale application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive Solar Energy and Power Storage Platform for Multimetered Properties

Veritel Energy LLC has successfully demonstrated the feasibility of its innovative adaptive solar energy and power storage platform designed for multimetered properties in Phase I of its DOE SBIR grant. The project centered around the development and initial deployment of proprietary hardware and software system that manages and distributes site-generated renewable energy to multiple tenants efficiently. This system integrates seamlessly with existing building infrastructure and utility systems, making it a viable solution for aging multifamily properties often located in at-risk communities. The pilot system was installed in a multifamily building with a single master-meter, and functioned as a pilot to demonstrate a scalable model for renewable energy system adoption across similar properties. This installation not only showed potential for significant reductions in greenhouse gas emissions but also improved the economic viability of renewable installations by allowing property owners to recoup investments through increased energy savings and tenant billing. The Phase I project set the groundwork for further enhancements and testing in Phase II which will aim to apply the technology to projects with dozens of sub-meters, further contributing to the decarbonization of the built environment.

14 SOLAR ENERGY↗

A Contextually Supervised Optimization-Based HVAC Load Disaggregation Methodology

This paper presents a novel contextually supervised optimization-based approach for disaggregating heating, ventilation, and air-conditioning (HVAC) loads using smart meter or Supervisory Control and Data Acquisition data. To disaggregate the load into HVAC loads, large and infrequently used loads (LIUL), and base loads, we formulate an optimization problem to minimize a set of five loss terms, consisting of the reconstruction errors of the overall load profile, the ramp rate losses, and three distinct loss functions linked with the HVAC load, base load, and LIUL, respectively. To enhance accuracy, we incorporate two forms of contextual information into the problem formulation. First, we utilize mutual information to estimate HVAC energy consumption. Second, we employ a base load dictionary to constrain HVAC load estimation errors. The obtained HVAC load profiles are fine-tuned by abnormal ramp detection followed by binary hypothesis testing. Here, the proposed method is developed and tested using sub-metered residential and commercial building data. Simulation results show that the proposed method outperforms existing methods across various data resolutions and load aggregation levels, showing excellent transferability and generalizability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-driven evaluation of HVAC operation and savings in commercial buildings

Commercial buildings consumed 36% of electricity, or 1.35 trillion kWh, in the United States in 2017, and almost 30% of this energy was wasted. Much of this loss can be attributed to inefficient heating ventilation and air con­ditioning (HVAC) systems. By improving the operational conditions of HVAC, significant savings can be achieved. However, most buildings and building equipment do not use costly sub-meters to monitor and address performance issues, and on-site auditing can be expensive and insufficient. Alternatively in this study, we propose a data-driven method to identify savings opportunities using only whole building meter data and without setting foot in the building. For this purpose, we introduced two algorithms that virtually quantify the value of a thermostat setpoint setback and HVAC rescheduling. Additionally, we developed novel methods for detecting occupancy patterns and quantifying the baseload of the HVAC operation. Using a clustering algorithm, we identified those buildings for which HVAC savings was significant and further categorized the buildings based on their potential for savings. A population study of over 432 commercial buildings demonstrated a median percentage energy savings of 1.6% from a baseload reduction and 2.1% from HVAC rescheduling. Additionally, results indicate that retail buildings have the highest potential for savings among the building types studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dephasingless laser wakefield acceleration in the bubble regime

Abstract Laser wakefield accelerators (LWFAs) have electric fields that are orders of magnitude larger than those of conventional accelerators, promising an attractive, small-scale alternative for next-generation light sources and lepton colliders. The maximum energy gain in a single-stage LWFA is limited by dephasing, which occurs when the trapped particles outrun the accelerating phase of the wakefield. Here, we demonstrate that a single space–time structured laser pulse can be used for ionization injection and electron acceleration over many dephasing lengths in the bubble regime. Simulations of a dephasingless laser wakefield accelerator driven by a 6.2-J laser pulse show 25 pC of injected charge accelerated over 20 dephasing lengths (1.3 cm) to a maximum energy of 2.1 GeV. The space–time structured laser pulse features an ultrashort, programmable-trajectory focus. Accelerating the focus, reducing the focused spot-size variation, and mitigating unwanted self-focusing stabilize the electron acceleration, which improves beam quality and leads to projected energy gains of 125 GeV in a single, sub-meter stage driven by a 500-J pulse.

43 PARTICLE ACCELERATORS↗

An Optimization-Based HVAC Load and PV Disaggregation Methodology With Contextual Supervision

Here, this letter presents an optimization-based Heating, Ventilation, and Air Conditioning (HVAC) and PV disaggregation approach. This letter builds on the previous works of authors, which discuss HVAC disaggregation strategy for aggregated levels without requiring sub-metered information. This letter expands on previous works to discuss optimization-based HVAC disaggregation by varying PV penetration scenarios with joint disaggregation of HVAC load and PV.

Analytics↗