Search NASA⌕ Search

SEARCH · Search NASA

Results for “sub-wavelength apertures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Potential Challenges in Near-Field Scanning Optical Microscopy for Space Applications

Near-field scanning optical microscopy (NSOM) also called scanning near-field optical microscopy (SNOM) is now well accepted as a powerful tool for sub-wavelength (nanoscale in the optical region) spatial resolution microscopy and a large number of related tasks. The importance lies in the fact of strategic advantages of standard microscopy but with significantly enhanced resolution. Since many modern optical diagnostic techniques have found useful applications in space, it is logical to consider the future role of NSOM in such situations. For example, protein crystal growth study under microgravity conditions is a valid candidate. If applied successfully, processes at molecular level can be studied during the growth. NSOM has already been demonstrated to be useful for the study of such crystals here on earth. The basic principle of NSOM can be illustrated. The illumination-collection mode is shown although several other possible approaches exist. In this, the sample is illuminated and the light from the sample is collected through the same tiny aperture opening. A tapered optical fiber is scanned near the sample surface. The tip is coated generally with a metal with a sub-wavelength aperture opening. The tip-sample distance is maintained constant while scanning. Thus, the optical signal available for collection is generally a function of the optical properties of the sample surface. Since the aperture is sub-wavelength in diameter and the tip is held very close (again in the sub-wavelength domain) to the surface, the lateral resolution in the sub-wavelength domain is obtained. Thus, the typical wavelength- order resolution of ordinary microscopy can be significantly enhanced while maintaining the strategic advantages (no need of sample in vacuum chamber, electron beams, etc). Commercial NSOM systems play a key role in the success and widespread acceptance of the tool. These commercial systems work fairly well in laboratory conditions on earth. However, they may not be deployed on a space mission as such with comparable outcome. In this communication we discuss several potential problems and some possible solutions.

Vikram, Chandra S.↗

OCCAMS: Optically Controlled and Corrected Active Meta-Material Space Structures

Telescopes require sub-wavelength figure (shape) error in order to achieve acceptable Strehl ratios. Traditional methods of achieving this require rigid and therefore heavy mirrors and reaction structures as well as proportionally heavy and expensive spacecraft busses and launch vehicles. This effectively limits the diameter and therefore resolution and collecting area of space optics. Large diameter telescopes must either be heavy or actively controlled. Space telescopes of the size proposed for missions such as TPF (Terrestrial Planet Finder), TPI (Terrestrial Planet Imager), etc. will likely require large active primaries and structures and corrective optics to implement downstream wavefront control. We propose a novel viable enabling technology. High resolution space imaging requires the production of lightweight large aperture optics subject to design tradespace constraints based on nanometer physical tolerances, low system aerial density, high control authority, suitable thermal and mechanical properties, deployment capability, launch vehicle volume constraints, as well as production cost and schedule risk mitigation. Segmented systems impose additional requirements on segment alignment, wavefront phasing, and telescope mass with increased edge diffraction. Photons weigh nothing. Why must even small space telescopes "weigh" tons? Our team is working to demonstrate that they do not, by leveraging 15 years of effort and a novel advanced concept.The ultimate research goal is to refine technology to produce a mission capable ultra-lightweight membrane optic whose shape can be remotely controlled using a laser beam. Using our novel optically-controlled molecular actuators allows substitution of optically-induced control for rigidity and mirror mass. In analogy with noise-canceling headphones, this technique also potentially provides a way to excite vibratory modes to couple with and damp out normal modes of oscillation induced by slewing, other motion and thermal changes, thus allowing a robust response to repointing of a large aperture.

Astronomy↗

Investigation of Space Interferometer Control Using Imaging Sensor Output Feedback

Numerous space interferometry missions are planned for the next decade to verify different enabling technologies towards very-long-baseline interferometry to achieve high-resolution imaging and high-precision measurements. These objectives will require coordinated formations of spacecraft separately carrying optical elements comprising the interferometer. High-precision sensing and control of the spacecraft and the interferometer-component payloads are necessary to deliver sub-wavelength accuracy to achieve the scientific objectives. For these missions, the primary scientific product of interferometer measurements may be the only source of data available at the precision required to maintain the spacecraft and interferometer-component formation. A concept is studied for detecting the interferometer's optical configuration errors based on information extracted from the interferometer sensor output. It enables precision control of the optical components, and, in cases of space interferometers requiring formation flight of spacecraft that comprise the elements of a distributed instrument, it enables the control of the formation flying vehicles because independent navigation or ranging sensors cannot deliver the high-precision metrology over the entire required geometry. Since the concept can act on the quality of the interferometer output directly, it can detect errors outside the capability of traditional metrology instruments, and provide the means needed to augment the traditional instrumentation to enable enhanced performance. Specific analyses performed in this study include the application of signal-processing and image-processing techniques to solve the problems of interferometer aperture baseline control, interferometer pointing, and orientation of multiple interferometer aperture pairs.

Cheng, Victore H. L.↗

Investigation of Space Interferometer Control Using Imaging Sensor Output Feedback

Numerous space interferometry missions are planned for the next decade to verify different enabling technologies towards very-long-baseline interferometry to achieve high-resolution imaging and high-precision measurements. These objectives will require coordinated formations of spacecraft separately carrying optical elements comprising the interferometer. High-precision sensing and control of the spacecraft and the interferometer-component payloads are necessary to deliver sub-wavelength accuracy to achieve the scientific objectives. For these missions, the primary scientific product of interferometer measurements may be the only source of data available at the precision required to maintain the spacecraft and interferometer-component formation. A concept is studied for detecting the interferometer's optical configuration errors based on information extracted from the interferometer sensor output. It enables precision control of the optical components, and, in cases of space interferometers requiring formation flight of spacecraft that comprise the elements of a distributed instrument, it enables the control of the formation-flying vehicles because independent navigation or ranging sensors cannot deliver the high-precision metrology over the entire required geometry. Since the concept can act on the quality of the interferometer output directly, it can detect errors outside the capability of traditional metrology instruments, and provide the means needed to augment the traditional instrumentation to enable enhanced performance. Specific analyses performed in this study include the application of signal-processing and image-processing techniques to solve the problems of interferometer aperture baseline control, interferometer pointing, and orientation of multiple interferometer aperture pairs.

Leitner, Jesse A.↗