The incipience of flow oscillations in forced- flow subcooled boiling.
Flow oscillation incipience when subcooled liquid undergoes phase change under forced flow conditions in single-tube boiler
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Flow oscillation incipience when subcooled liquid undergoes phase change under forced flow conditions in single-tube boiler
Onset of flow oscillations of subcooled liquid in forced flow conditions in single tube boiler
Onset of flow oscillations when subcooled liquid undergoes phase change under forced flow in single tube boiler
This study investigates critical heat flux (CHF) for subcooled flow boiling of n-Perfluorohexane based on results of pre-launch Earth-gravity Mission Sequence Tests (MSTs) of the Flow Boiling and Condensation Experiment (FBCE), which was launched to the International Space Station (ISS) in August 2021. CHF measurements were made in a rectangular channel having a 2.5 mm by 5 mm cross-section and a 114.6-mm long heated segment. Both single-sided and double-sided heating were tested in vertical upflow in Earth gravity for a variety of inlet conditions. The inlet subcooling was varied in the range of 0.4 – 32.0°C and encompassed both near-saturated and highly subcooled conditions. Experimental trends and high-speed video records were investigated to better understand the mechanism of CHF. Overall trends show CHF increases as flow rate and/or inlet subcooling are increased. Flow features from the events around CHF justify the applicability of the Interfacial Lift-off Model and the determination of limiting criteria for its application. The present experimental data are combined with prior databases for various flow orientations with respect to Earth gravity and microgravity data collected on parabolic flights. Predictions are made using the Interfacial Lift-off Model for this consolidated subcooled-inlet FBCE-CHF database. A heat utility ratio was included in the model to capture the effects of subcooling and corresponding thermodynamic non-equilibrium. An overall mean absolute error of 19.04% indicates good predictive capability of the model for both heating configurations, different gravity environments, and a wide range of inlet subcooling.
Subcooled flow boiling combines complex processes governed by a strong coupling of heat and mass transfer, hydrodynamics, and liquid-vapor transitions. The gravitational body force plays an important role in these processes. By exploiting the latent heat of vaporization, subcooled flow boiling can transfer up to several orders-of-magnitude more heat compared to forced liquid flow. It is widely used in Earth-based thermal equipment to reduce the cost, size, and power required to move heat. Subcooled flow boiling is now considered a promising technology for space applications since it offers a means to control the motion of bubbles near the heated surface and thereby enhance nucleate boiling. However, a lack of data and predictive models on the role that gravity plays in these phenomena hinders the use of flow boiling in a microgravity environment. We will present results of experiments on transients in nucleate boiling that were carried out in the Flow Boiling Module (FBM) on the International Space Station (ISS). The unique ISS FBM ability is to couple large heat loads with flow visualization in testing flow boiling under strict control of experimental conditions in long-duration microgravity. Comparison of results of microgravity experiments with data obtained in a similar setup on the NASA GRC demonstrates the role of gravity in nucleate boiling. The work is supported by the NASA Flight Opportunities program (grant 80NSSC21K0501) and NSF/CASIS program (NSF CBET grants 1832260, 2126461, 2126462).
This study is part of the Flow Boiling and Condensation Experiment (FBCE), a collaborative effort between the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and the NASA Glenn Research Center. The FBCE fitted with the Flow Boiling Module (FBM) was launched to the International Space Station (ISS) in August 2021 and experiments were successfully performed from February to July 2022 to amass a large microgravity-flow-boiling database. This study is focused on heat transfer and flow visualization of microgravity flow boiling of n-Perfluorohexane in a rectangular channel of 5.0 mm height, 2.5 mm width (heated), and 114.6 mm length, with subcooled inlet conditions. High-speed-video photography is utilized to present flow patterns and temporal interfacial behavior. Heat transfer results are presented in the form of flow boiling curves and both parametric curves and streamwise profiles of wall temperature and heat transfer coefficient. Firstly, the parametric effects of mass velocity (199.4 – 3200.0 kg/m 2 s), inlet subcooling (0.2 – 46.0°C), and inlet pressure (124.2 – 176.7 kPa), on the aforementioned aspects are assessed for double-sided heating to establish them for a microgravity environment. Of these three parameters, mass velocity and inlet subcooling mostly determine the microgravity flow boiling behavior, while inlet pressure plays an insignificant role. Flow patterns for double-sided heating are more complex than those for single-sided heating due to interaction between the two vapor layers. Vapor interaction is minimized at high subcoolings and high mass velocities due to strong condensation offered by the subcooled bulk liquid layer separating them. Despite the different flow patterns, both single- and double-sided heating generally result in similar parametric trends and local heat transfer coefficients for similar operating conditions. Flow instabilities manifest as temporal flow anomalies and temperature oscillations, and their severity increases with increasing boiling number. Secondly, the effects of heating configuration are analyzed by comparing and contrasting several aspects of single- and double-sided heating data. The heat fluxes at which onset of nucleate boiling degradation (ONBD) and critical heat flux (CHF) occur are distinctly different for single- and double-sided heating. There exists a threshold inlet subcooling demarcating the dominance of flow acceleration and condensation effects in vapor removal from the near-wall region and replenishment of fresh liquid for boiling. Above the threshold, condensation from the near-wall region is dominant and single-sided heating yields higher heat fluxes, and below it, acceleration is dominant and double-sided yields higher heat fluxes. At mass velocity in the range of 200 – 2400 kg/m 2 s, the threshold inlet subcooling lies in the approximate range of 20 – 30°C (corresponding inlet quality of roughly -0.40 – -0.20).
Experiments were performed to examine the effects of body force on flow boiling critical heat flux (CHF). FC-72 was boiled along one wall of a transparent rectangular flow channel that permitted photographic study of the vapor-liquid interface just prior to CHF. High-speed video imaging techniques were used to identify dominant CHF mechanisms corresponding to different flow orientations and liquid velocities. Six different CHF regimes were identified: Wavy Vapor Layer, Pool Boiling, Stratification, Vapor Counterflow, Vapor Stagnation, and Separated Concurrent Vapor Flow. CHF showed significant sensitivity to orientation for flow velocities below 0.2 m/s, where extremely low CHF values where measured, especially with downward-facing heated wall and downflow orientations. High flow velocities dampened the effects of orientation considerably. The CHF data were used to assess the suitability of previous CHF models and correlations. It is shown the Interfacial Lift-off Model is very effective at predicting CHF for high velocities at all orientations. The flooding limit, on the other hand, is useful at estimating CHF at low velocities and for downflow orientations. A new method consisting of three dimensionless criteria is developed for determining the minimum flow velocity required to overcome body force effects on near-saturated flow boiling CHF. Vertical upflow boiling experiments were performed in pursuit of identifying the trigger mechanism for subcooled flow boiling CHF. While virtually all prior studies on flow boiling CHF concern the prediction or measurement of conditions that lead to CHF, this study was focused on events that take place during the CHF transient. High-speed video imaging and photomicrographic techniques were used to record the transient behavior of interfacial features from the last steady-state power level before CHF until the moment of power cut-off following CHF. The video records show the development of a wavy vapor layer which propagates along the heated wall, permitting cooling prior to CHF only in wetting fronts corresponding to the wave troughs. Image analysis software was developed to estimate void fraction from the individual video images. The void fraction records for subcooled flow boiling show the CHF transient is accompanied by gradual lift-off of wetting fronts culminating in some maximum vapor layer mean thickness, following which the vapor layer begins to thin down as the transition to film boiling ensues. This study proves the Interfacial Lift-off Model, which has been validated for near-saturated flow boiling CHF, is equally valid for subcooled conditions.
An experimental study was made of subcooled flow boiling with LOX; data were obtained with thermocouples attached to the walls of an electrically heated tube through which the LOX flowed. Pressure levels in the tube ranged from 200 psia to supercritical values, and the cooling level varied from the saturated condition to 50 F. Reynolds numbers ranged from 1.5 x 10 to 3.5 x 10 to the 5th. Results show that an increase in either pressure, subcooling level, or Reynolds number produces an increase in the film boiling heat transfer coefficient. Data for this range of parameters were found to correlate in terms of the Stanton number vs (T sub w - T sub s)/(T sub s - T sub b), where T is temperature, w is the wall, s is the saturated condition, and b is the bulk.
The use of flow boiling for thermal energy transport is intended to provide an alternative for accommodating higher heat fluxes in commercial space systems. The objectives are to: (1) examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for a circular coolant channel with either smooth walls, spiral fins, or both spiral fins and a twisted tape; (2) examine the effects of channel diameter and subcooling; and (3) develop an improved reduction analysis and/or suggest possible heat transfer correlation of the present data. Freon-11 is the working fluid. Two-dimensional (circumferential and axial) wall temperature distributions were measured for coolant channels with the above noted internal geometries. The flow regimes which are being studied are: (1) single phase; (2) subcooled flow boiling; and (3) stratified flow boiling. The inside diameter of all test sections is near 1.0 cm. Cicumferentially averaged heat transfer coefficients at several axial locations were obtained for selected coolant channels for a mass velocity of 210 kg/sq m s, an exit pressure of 0.19 MPa (absolute), and an inlet subcooling of 20.8 C. Overall (averaged over the entire channel) heat transfer coefficients were compared for the above channel geometries. This comparison showed that the channel with large pitch spiral fins had higher heat transfer coefficients at all power levels.
Two phase thermal management systems that capitalize on both latent and sensible heats of the working fluid can yield orders of magnitude enhancements in flow boiling and condensation heat transfer coefficients and reduce size and weight of future space systems. Because the understanding of microgravity influences on two-phase flow and heat transfer is quite limited, there is presently an urgent need for a new experimental microgravity facility to enable investigators to perform long-duration flow boiling and condensation experiments in pursuit of reliable databases. This presentation will discuss results from the Flow Boiling and Condensation Experiment (FBCE), a collaborative effort between Purdue University and NASA Glenn Research Center. Experiments have been performed using the final system with the Flow Boiling Module (FBM) in vertical orientation in Earth gravity (Mission Sequence Tests, MST) and in microgravity onboard the International Space Station (ISS). High-speed-video flow visualization, heat transfer, and critical heat flux (CHF) results from the MST are presented for both subcooled liquid and saturated liquid-vapor inlet conditions. CHF predictions made using the Interfacial Lift-off Model are compared with a consolidated database made by compiling FBM datasets obtained in prior years for different orientations in Earth gravity and on parabolic flights. New explicit correlations for CHF and subcooled flow boiling heat transfer coefficient are developed and shown to be excellent in their predictive accuracies against consolidated experimental databases. Computations are performed for flows in microgravity and horizontal flows in Earth gravity, the results of which show a good predictive accuracy for both void fraction and wall temperature. Finally, similar preliminary results from the recent ISS experiments are presented.
An experimental study was conducted in top-heated finned horizontal tubes to study the effect of enhancement devices on flow boiling heat transfer in coolant channels. The objectives are to examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for circular coolant channels with spiral finned walls and/or spiral fins with a twisted tape, and improve the data reduction technique of a previous investigator. The working fluid is freon-11 with an inlet temperature of 22.2 C (approximately 21 C subcooling). The coolant channel's exit pressure and mass velocity are 0.19 M Pa (absolute) and 0.21 Mg/sq. ms, respectively. Two tube configurations were examined; i.e., tubes had either 6.52 (small pitch) or 4.0 (large pitch) fins/cm of the circumferential length (26 and 16 fins, respectively). The large pitch fins were also examined with a twisted tape insert. The inside nominal diameter of the copper channels at the root of the fins was 1.0 cm. The results show that by adding enhancement devices, boiling occurs almost simultaneously at all axial locations. The case of spiral fins with large pitch resulted in larger mean (circumferentially averaged) heat transfer coefficients, h sub m, at all axial locations. Finally, when twisted tape is added to the tube with large-pitched fins, the power required for the onset of boiling is reduced at all axial and circumferential locations.
One dimensional flow model to correlate subcooled boiling pressure drop in circular tubes with constant heat flux
This study is the culmination of a long-term collaborative effort between researchers from the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and the NASA Glenn Research Center to investigate gravitational effects on flow boiling and flow condensation. The science and design concepts for this large-scale effort were initiated in 2011 and included several studies detailing various aspects of two-phase fluid physics in both Earth gravity and microgravity, culminating in construction of the large-scale experimental facility named “Flow Boiling and Condensation Experiment (FBCE)”. The experiment was launched to the International Space Station (ISS) in August 2021. Following the successful installation of FBCE, equipped with the Flow Boiling Module (FBM), onboard the ISS and completion of several safety checks, flow boiling experiments were performed for five months from February 2022 until July 2022. This resulted in a large flow boiling database covering broad ranges of operating parameters and heating configurations spanning several research objectives. This study investigates microgravity flow boiling of n-perfluorohexane with subcooled inlet in a single-side-heated rectangular channel of dimensions 114.6-mm heated length, 2.5-mm heated width, and 5.0-mm height. Key operating parameters investigated are mass velocity (199.90 – 3200.13 kg/m 2 s), inlet subcooling (0.10 – 45.76°C), and inlet pressure (113.30 – 164.29 kPa). Images and image sequences acquired via high-speed-video are presented to elucidate the interfacial flow physics. To analyze and explain the effects of various parameters in microgravity, heat transfer results are presented as flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric trends of local and averaged heat transfer coefficient. Mass velocity and inlet subcooling significantly influenced most of the aforementioned aspects of flow boiling, whereas effects of inlet pressure were comparatively insignificant. Although the data and observed flow physics might be different, the parametric effects and trends in microgravity are similar to vertical upflow in Earth gravity. Some cases, especially low mass velocities, high heat fluxes, and large degrees of inlet subcooling, experienced temporally anomalous flow behaviors caused by two-phase flow instabilities manifesting as flow reversals and resulted in deviations in overall trends. Severe thermodynamic non-equilibrium is observed throughout the channel. Overall, FBCE’s ISS experiments were successful for subcooled inlet with single-sided heating of rectangular channel, and the collected data well established the various effects on flow boiling physics in highly controlled long-term microgravity conditions.
An experimental proceedure for examining flow boiling in low gravity environment is presented. The proceedure involves both ground based and KC-135 flight experiments. Two experimental apparati were employed, one for studying subcooled liquid boiling and another for examining saturated liquid boiling. For the saturated flow experiments, liquid nitrogen was used while freon 113 was used for the subcooled flow experiments. The boiling phenomenon was investigated in both cases using flow visualization techniques as well as tube wall temperature measurements. The flow field in both cases was established by injecting cold liquid in a heated tube whose temperature was set above the saturation values. The tubes were both vertically and horizontally supported with the liquid injected from the lower end of the tube. The results indicate substantial differences in the flow patterns established during boiling between the ground based, (1-g), experiments and the flight experiments, (low-g). These differences in the flow patterns will be discussed and some explanations will be offered.
The high power density of emerging electronic devices is driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which extracts dissipated heat on-site. Two-phase microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel within or between devices. Such coolers must work reliably in all orientations for a variety of applications (e.g., vehicle-based equipment), as well as in microgravity and high-g for aerospace applications, but the lack of acceptable models and correlations for orientation- and gravity-independent operation has limited their use. Reliable criteria for achieving orientation- and gravity-independent flow boiling would enable emerging systems to exploit this thermal management technique and streamline the technology development process. As a first step toward understanding the effect of gravity in two-phase microgap flow and transport, in an earlier effort, the authors studied the effects of evaporator orientation, mass flux, and heat flux on flow boiling of HFE7100 in a 1.01 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. Orientation-independence, defined as achieving similar critical heat fluxes, heat transfer coefficients, and flow regimes across orientations, was achieved for mass fluxes of 400 kg/sq.m-s and greater (corresponding to a Froude number of about 0.8). In the present effort, the authors have studied the effects of gravity, mass flux, and subcooling on flow boiling of HFE7100 in a 0.17 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. The Flow Boiling in Microgap Coolers payload experienced about three minutes of weightlessness and shorter periods of high-g (up to about 5 g) during two recent flights aboard the Blue Origin New Shepard reusable launch vehicle. The results from the flight experiments will be presented and compared with published criteria for achieving gravity-independence.
Two-phase thermal management subsystems that take advantage of both the sensible and latent heat of a working fluid can potentially yield significant enhancements in overall performance by adopting heat transfer processes that are based on phase transition like boiling and condensation. Performance of terrestrial two-phase flow systems may be predictable because the hydrodynamic and body forces are understood, however, in microgravity, which is predominant during planetary space travel, forces that are masked by the strong body force on Earth (gravitational or buoyancy force) reappear with different magnitude and influence. The need arose for a facility that provides for two-phase flow with phase transition testing in microgravity. The Flow Boiling and Condensation Experiment (FBCE) is a facility that was launched to the International Space Station in August of 2021 and is in operation since February of 2022. This facility enables investigators to perform two-phase flow and phase transition research in flow boiling and condensation. Along with the test module that is experiment specific, the FBCE system consists of the fluid, avionics, and software subsystems. Currently two test modules, namely, the Flow Boiling Module (FBM) and the Condensation Module for Heat Transfer (CM-HT) are available. A third module, the Transfer Line test Module (TL) is being developed. The fluid subsystem conditions and delivers the fluid at the desired thermodynamic state to the test module. It consists of two fluid modules and a heater module that are connected by flex hoses for fluid circulation and by data and electrical cables for control and data acquisition. Two avionics modules acquire pressure and temperature data from various sensors in the flow loop. For FBM, a high-speed camera is available to acquire images of the boiling process. Experiments are operated autonomously by software and are based on an Experiment Parameters Master Table (EPMT) that is uploaded to ISS and is executed by the FBCE flight software. This presentation briefly introduces the objectives of FBCE and provides a system description of the experiment onboard of the ISS/Fluid Integrated Rack (FIR). Results of the test campaign carried out using the FBM are presented. Specifically, microgravity flow boiling of n-perfluorohexane (test fluid) is discussed with subcooled inlet conditions in a single-side-heated rectangular channel of dimensions 114.6-mm heated length, 2.5-mm heated width, and 5.0-mm height. Key operating parameters investigated are mass velocity (199.90 – 3200.13 kg/m2s), inlet subcooling (0.10 – 45.76°C), and inlet pressure (113.30 – 164.29 kPa). Image sequences acquired via high-speed-video are shown to elucidate the interfacial flow physics. The effects of various parameters on flow boiling heat transfer in microgravity, from the onset of boiling to the critical heat flux are discussed. Heat transfer results are presented in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric trends of local and averaged heat transfer coefficient, and the critical heat flux.
Laminar two-phase boundary layer flow in film boiling, obtaining asymptotic solutions for low and high subcooled liquids
Since 2012, researchers at the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and NASA Glenn Research Center have been collaborating on a long-term effort to study flow boiling and condensation in microgravity. The ultimate goal has been to develop the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS). Based on the findings from prior flow boiling experiments both at different orientations in Earth gravity and onboard parabolic flights simulating short durations of microgravity, a final refined experiment design, construction, and operating procedure have been arrived at for long-duration microgravity flow boiling experiments onboard the ISS. This study investigates flow boiling of n-Perfluorohexane with subcooled inlet in a rectangular channel of dimensions 114.6 mm heated length, 2.5 mm width, and 5 mm height. These pre-launch experiments (Mission Sequence Testing) were conducted in vertical upflow orientation in Earth gravity using the same experimental rig that was launched to the ISS in August 2021. The various operating parameters varied are heating configuration (single- and double-sided), mass velocity (180 – 3200 kg/m2s), inlet subcooling (+0 – 32°C, encompassing both highly subcooled and near-saturated inlet conditions), and inlet pressure (119 – 191 kPa). High-speed video flow visualization images are presented to explain the two-phase interfacial physics within the channel’s heated section. Heat transfer results in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and averaged heat transfer coefficients are analyzed and parametric effects elucidated. Severe temporal thermodynamic equilibrium is observed for near-saturated inlet at very low velocities. Nucleate boiling degradation starts at larger heat fluxes for single-sided heating than double sided at low mass velocities with highly subcooled inlet, and conversely at high mass velocities with near-saturated inlet. Nucleate boiling degradation can be delayed to higher heat fluxes by highly subcooling the inlet and increasing mass velocity. The entire local heat transfer coefficient profiles are degraded at higher heat fluxes for near-saturated inlet, but only the downstream part for highly subcooled inlet. This study also confirmed reliability of the upcoming ISS experimental data for subcooled inlet conditions and the collected Earth-gravity data will be used for comparison against the ISS data.