Search NASA⌕ Search

SEARCH · Search NASA

Results for “subcritical experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Morgana Overview – NCERC Support for Dynamic Subcritical Experiments

The LANL Subcritical Experiments Program (SCE) recently executed the Morgana Subcritical Experiment at the NNSS. This was the first subcritical experiment executed by LANL for several years (since 2021). It was also notably the first that required SCE personnel to have FMH qualifications for a portion of the work conducted under nuclear criticality safety limits.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Additionally, key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Fidelity Dynamic Neutron Imaging and Radiography for Subcritical Experiments and Other Applications (Final Report)

This project aims to advance neutron technologies that support subcritical experiments (SCEs) and other dynamic material applications. In previous years, there were three main thrusts for this project. The first and main effort focused on imaging the source of neutrons on a dense plasma focus (DPF). The second portion focused on improving the neutron yield from a DPF. The source developed on the Nevada National Security Site (NNSS) Gemini DPF yielded ~8 × 10 11 deuterium-deuterium (DD) neutrons/pulse in relatively short pulse widths of approximately 100 ns FWHM.

47 OTHER INSTRUMENTATION↗

Delayed Critical and Subcritical Experiments with Polyethylene Moderated Unreflected Thin 15 in. Diameter HEU Metal Plates

The thin ~15 in. diameter highly enriched uranium (HEU) metal plates were assembled to delayed criticality at the Oak Ridge Critical Experiments Facility (ORCEF) in 1969 with various thicknesses of polyethylene (varying from 1/16 to 2$\frac{3}{8}$ inches) between uranium metal plates. The average 235 U enrichment was 93.27 wt. %. These unreflected critical configurations contained 4$\frac{2}{3}$ to 20$\frac{5}{6}$ thin 15 in. diameter HEU metal plates (on loan from Los Alamos National Laboratory [LANL] and shipped to Oak Ridge National Laboratory [ORNL] on June 3, 1969). Depending on the thickness of polyethylene, the enriched uranium masses varying from 28,053 to 135,148 grams. Fractional plate sections consisted of the appropriate number of 60° pie sections. In addition to the measurement at delayed criticality, subcritical measurements were also performed by the inverse kinetic rod drop method. Prompt neutron decay constant measurements were also performed by the Rossi alpha and randomly pulsed neutron method using a time-tagged spontaneous fission californium neutron source; these are briefly reported here. At the time of these measurements in 1969, the thin HEU metal plates were in near-pristine condition with extremely little oxidation, allowing better descriptions of the uranium plates than the use of these plates in a heavily oxidized and deteriorated condition in recent reflected benchmark experiments at the LANL facility at the Nevada Test Site with these same thin highly enriched uranium metal plates. This report documents the experimental information for the measurements performed so that later researchers can perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Evaluation Program (ICSBEP) or a Nuclear Energy Agency (NEA) benchmark. Data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program once the uncertainty analysis on the measured neutron multiplication factors is completed. Additional data—such as the dimensional inspection reports, uranium isotopic information, and other relevant particulars—should be retrieved from the Y-12 Plant or LANL and incorporated in the final ICSBEP benchmark. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in $k_{eff}$ could be as low as ± 0.0002 for some configurations. Other experiments with smaller-diameter than 15 in. diameter HEU metal plates have been benchmarked in HEU-METFAST-001. The prompt neutron time decay measurements could be the basis for an International Reactor Physics Benchmark Program. Preparation of the present report is part of an effort at ORNL to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities using more than 500 operational days of critical facility time. This work for this report publication was supported by the Nuclear Criticality, Radiation Transport and Safety NCSP Program at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-518: Data Analysis for High Multiplication Subcritical Experiments [Slides]

This presentation begins with a discussion of goals & motivation. This lecture then covers: experimental configurations, computational models, experimental measurements and simulations. Finally, this presentation concludes with data analysis & results plus a conclusion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗