Search NASA⌕ Search

SEARCH · Search NASA

Results for “subcritical multiplication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wing analysis using a transonic potential flow computational method

The ability of the method to compute wing transonic performance was determined by comparing computed results with both experimental data and results computed by other theoretical procedures. Both pressure distributions and aerodynamic forces were evaluated. Comparisons indicated that the method is a significant improvement in transonic wing analysis capability. In particular, the computational method generally calculated the correct development of three-dimensional pressure distributions from subcritical to transonic conditions. Complicated, multiple shocked flows observed experimentally were reproduced computationally. The ability to identify the effects of design modifications was demonstrated both in terms of pressure distributions and shock drag characteristics.

Henne, P. A.↗

Multiple Equilibria Associated with Response of the ITCZ to Seasonal SST Forcing

Supported by numerical experiment results, the abrupt change of the location of the intertropical convergence zone (ITCZ), from the equatorial trough flow regime to the monsoon trough flow regime is interpreted as a subcritical instability. The existence of these multiple quasi-equilibria is due to the balance of two "forces" on the ITCZ: one toward the equator, due to the earth's rotation, has a nonlinear latitudinal dependence; and the other toward the latitude of the sea surface (or ground) temperature peak has a relatively linear latitudinal dependence. This work pivots on the finding that the ITCZ and Hadley circulation can still exist without the pole-to-equator gradient of radiative-convective equilibrium temperature.

Chao, Winston C.↗

Theory of time-dependent rupture in the Earth

Fracture mechanics is used to develop a theory of earthquake mechanism which includes the phenomenon of subcritical crack growth. The following phenomena are predicted: slow earthquakes, multiple events, delayed multiple events (doublets), postseismic rupture growth and afterslip, foreshocks, and aftershocks. The theory predicts a nucleation stage prior to an earthquake, and suggests a physical mechanism by which one earthquake may 'trigger' another.

Das, S.↗

Strouhal number influence on flight effects on jet noise radiated from convecting quadrupoles

The paper reports a complementary extension of previous work to include the high-frequency features reflected in the discussion of the higher Strouhal number influence on flight effects. It is found that, in addition to the usual features of flight effects on noise from ordinary flows, the high Strouhal number flows exhibit some more interesting features which are uniquely characteristic to them. The additional features are as follows: (1) Flight effects are more favorable to hot jets than to cold jets; (2) the higher the Strouhal number of the jet flow, the lesser the forward arc amplification due to flight; (3) as the Strouhal number increases, the peak amplification angle in the forward quadrant and the peak suppression angle in the aft quadrant move toward 90 deg and get closer, thus reducing the amplification exposure to a constricted angular region; (4) the silence zone is disturbed and displaced from its normal position parallel to the jet flow to give rise to multiple crossings of flight curves with the static line; and (5) the occurrence of multiple crossings is a strange phenomenon solely characteristic of high Strouhal number with high subcritical jet flows in flight.

Dash, R.↗

Internal strain analysis of ceramics using scanning laser acoustic microscopy

Quantitative studies of material behavior characteristics are essential for predicting the functionality of a material under its operating conditions. A nonintrusive methodology for measuring the in situ strain of small dimeter (to 11 microns) ceramic fibers under uniaxial tensile loading and the local internal strains of ceramics and ceramic composites under flexural loading is introduced. The strain measurements and experimentally observed mechanical behavior are analyzed in terms of the microstructural development and fracture behavior of each test specimen evaluated. Measurement and analysis of Nicalon silicon carbide (SiC) fiber (15 microns diameter) indicate that the mean elastic modulus of the individual fiber is 185.3 GPa. Deviations observed in the experimentally determined elastic modulus values between specimens were attributed to microstructural variations which occur during processing. Corresponding variations in the fracture surface morphology were also observed. The observed local mechanical behavior of a lithium alumino-silicate (LAS) glass ceramic, a LAS/SiC monofilament composite, and a calcium alumino-silicate (CAS)/SiC fully reinforced composite exhibits nonlinearities and apparent hysteresis due to the subcritical mechanical loading. Local hysteresis in the LAS matrices coincided with the occurrence of multiple fracture initiation sites, localized microcracking, and secondary cracking. The observed microcracking phenomenon was attributed to stress relaxation of residual stresses developed during processing, and local interaction of the crack front with the microstructure. The relaxation strain and stress predicted on apparent mechanical hysteresis effects were defined and correlated with the magnitude of the measured fracture stress for each specimen studied. This quantitative correlation indicated a repeatable measure of the stress at which matrix microcracking occurred for stress relief of each material system. Stress relaxation occurred prior to the onset of steady state cracking conditions. The relaxation stress occurred at 18.5 percent of the fracture stress in LAS and 11.0 percent of the yield stress in CAS/SiC. The relaxation stress ratio was dependent upon the dominant fracture mode of the LAS/SiC specimens. Relaxation stress ratios greater than 0.30 were observed for specimens which fractured due to shear at the fiber matrix interface; specimens which fracture due to tensile cracking had relaxation stress ratios less than 0.30. The stress relaxation ratio appeared to be a specific characteristic of the glass ceramic material. The measured stress relaxation for LAS indicated a measure of the inherent residual stresses in the material due to processing and suggested localized toughening mechanisms for brittle material structures.

Kent, Renee M.↗

Multiple-grid acceleration of Lax-Wendroff algorithms

A technique for accelerating the convergence of a one-step Lax-Wendroff method to a steady-state solution is discussed and its applicability extended to the more general class of two-step Lax-Wendroff methods. Several two-step methods which lead to quite efficient multiple grid algorithms are discussed. Computational results are presented using the full two dimensional Euler equations for both subcritical and shocked supercritical flows. Extensions and generalizations are mentioned.

Johnson, G. M.↗

Solutal convection during directional solidification

During directional solidification of a binary alloy at constant velocity, buoyancy-driven fluid flow may occur due to the solute gradients generated by the solidification process. Numerical calculations of the solute and fluid flow fields in the melt have been carried out using finite differences in a two-dimensional, time-dependent model that assumes a planar crystal-melt interface and allows time-dependent gravitational accelerations. The container walls are rigid and perfectly insulating for solute. For constant vertical gravitational accelerations, as the solutal Rayleigh number is varied, multiple steady states and time-dependent states may occur. The bifurcation from the quiescent state may be subcritical or transcritical, depending on the aspect ratio of the container. Calculations have also been performed for a gravitational acceleration that is assumed to be uniform in magnitude with its direction rotating uniformly. Numerical results have been obtained for a Schmidt number of 10 and a gravitational acceleration of 0.0001 G. The maximum variation in the solute concentration at the crystal-melt interface is calculated for various values of the rotation rate of the gravitational acceleration.

Mcfadden, G. B.↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the non-liquid-level-sensing temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode . a known function of the current and temperature . is measured as an indication of its temperature. For the purpose of this measurement, "small electric current" signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired locations along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode a known function of the current and temperature is measured as an indication of its temperature. For the purpose of this measurement, small electric current signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when the diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired location along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Subsonic 3-D surface panel method for rapid analysis of multiple geometry perturbations

For any baseline aircraft configuration, a matrix of partial derivatives of surface velocity potential with respect to geometry coordinates is calculated. Linear extrapolation is then used to analyze the subcritical potential flow corresponding to a series of arbitrary small geometry perturbations. Each perturbation analysis is more than an order of magnitude more efficient than a conventional panel method solution because no influence coefficients are calculated and no large system of linear algebraic equations is solved. Wing and wing-fuselage examples are presented to demonstrate that the predicted pressure distributions are nearly exact for large changes to wing camber, thickness, and leading edge radius.

Bristow, D. R.↗

Iterative optimal subcritical aerodynamic design code including profile drag

A subcritical aerodynamic design computer code has been developed, which uses linearized aerodynamics along with sweep theory and airfoil data to obtain minimum total drag preliminary designs for multiple planform configurations. These optimum designs consist of incidence distributions yielding minimum total drag at design values of Mach number and lift and pitching moment coefficients. Linear lofting is used between airfoil stations. Solutions for isolated transport wings have shown that the solution is unique, and that including profile drag effects decreases tip loading and incidence relative to values obtained for minimum induced drag solutions. Further, including effects of variation of profile drag with Reynolds number can cause appreciable changes in the optimal design for tapered wings. Example solutions are also discussed for multiple planform configurations.

Kuhlman, J. M.↗

Stabilization of a Swept-Wing Boundary Layer by Discrete Roughness Elements at High Reynolds Numbers

Direct numerical simulations (DNS) are performed to study potential stabilizing ef- fect of spanwise periodic discrete roughness elements (DREs) on cross ow instabilities in a spatially developing three-dimensional boundary layer over an in nite-swept natural- laminar- ow wing at a freestream Mach number of 0:75 and a chord Reynolds number of approximately 25 million. In the DNS, both the spanwise periodic DREs and distributed roughness in the leading-edge region are implemented to simulate a typical experimen- tal scenario in which multiple steady cross ow modes including the most unstable mode (i.e., the \target" mode) emerge because of the presence of naturally distributed surface roughness in the leading edge region and spanwise periodic control cylinders of subcritical wavelength are used to force small-wavelength disturbances (i.e., the control mode) for damping the target mode. The DNS results show that the e ectiveness of DRE control is sensitive to roughness diameter, height, and chordwise placement. For the DRE parame- ters considered in this study, the stabilizing e ect on the target mode is small within the computational domain that ended at about 35% of the chord.

Nicholson, Gary↗

The effects of participatory mode and task workload on the detection of dynamic system failures

The ability of operators to detect step changes in the dynamics of control systems is investigated as a joint function of, (1) participatory mode: whether subjects are actively controlling those dynamics or are monitoring an autopilot controlling them, and (2) concurrent task workload. A theoretical analysis of detection in the two modes identifies factors that will favor detection in either mode. Three subjects detected system failures in either an autopilot or manual controlling mode, under single-task conditions and concurrently with a subcritical tracking task. Latency and accuracy of detection were assessed and related through a speed accuracy tradeoff representation. It was concluded that failure detection performance was better during manual control than during autopilot control, and that the extent of this superiority was enhanced as dual-task load increased. Ensemble averaging and multiple regression techniques were then employed to investigate the cues utilized by the subjects in making their detection decisions.

Wickens, C. D.↗

Optimization of Polycyclic Aromatic Hydrocarbon (PAH) Extraction Efficiency Parameters for Sub- and Supercritical Water Extraction (SCWE) Instrument

Polycyclic aromatic hydrocarbons are a class of molecules composed of multiple, bonded benzene rings. As PAHS are believed to be present on Mars, positive confirmation of their presence on Mars is highly desirable. To extract PAHS, which have low volatility, a fluid extraction method is ideal, and one that does not utilize organic solvents is especially ideal for in situ instrumental analysis. The use of water as a solvent, which at subcritical pressures and temperatures is relatively non-Polar, has significant potential. As SCWE instruments have not yet been commercialized, all instruments are individually-built research prototypes: thus, initial efforts were intended to determine if extraction efficiencies on the JPL-built laboratory-scale SCWE instrument are comparable to differing designs built elsewhere. Samples of soil with certified reference concentrations of PAHs were extracted using SCWE as well as conventional Soxhlet extraction. Continuation of the work would involve extractions on JPL'S newer, portable SCWE instrument prototype to determine its efficiency in extracting PAHs.

Okada, Asahi A.↗

An initial investigation into methods of computing transonic aerodynamic sensitivity coefficients

Continuing studies associated with the development of the quasi-analytical (QA) sensitivity method for three dimensional transonic flow about wings are presented. Furthermore, initial results using the quasi-analytical approach were obtained and compared to those computed using the finite difference (FD) approach. The basic goals achieved were: (1) carrying out various debugging operations pertaining to the quasi-analytical method; (2) addition of section design variables to the sensitivity equation in the form of multiple right hand sides; (3) reconfiguring the analysis/sensitivity package in order to facilitate the execution of analysis/FD/QA test cases; and (4) enhancing the display of output data to allow careful examination of the results and to permit various comparisons of sensitivity derivatives obtained using the FC/QA methods to be conducted easily and quickly. In addition to discussing the above goals, the results of executing subcritical and supercritical test cases are presented.

Carlson, Leland A.↗

Buckling Testing of a Subscale Composite Cylinder

A subscale solid laminate composite cylinder with a 31.5-in. diameter, a 48.2-in. length, and a [23/0/-23]4S layup was designated NDL-1 and was designed to fail in buckling after a series of subcritical tests. NDL-1 was experimentally loaded in axial compression until buckling at 466.3 kips. Visual inspection of the test article after the test revealed that a shallow area of delamination occurred near the buckling initiation site. After a successful first buckling test, there was an opportunity to test NDL-1 in axial compression to failure a second time despite that the test article was not designed or analyzed for multiple buckling tests. During the second test to failure, NDL-1 reached a peak load of 390.4 kips, 16.3% lower than the first test. Buckling did not initiate in the same location during the second test to failure as the first test to failure. The second buckling event caused a large V-shaped crack that penetrated through the thickness of the barrel. Though buckling initiated at different locations, a similar radial deformation pattern was present just prior to buckling during the both tests. In the end, NDL-1 maintained a significant amount of its structural integrity and a similar prebuckling radial displacement pattern, even after the first buckling test.

Test↗

Simulation of preburner sprays, volumes 1 and 2

The present study considered characteristics of sprays under a variety of conditions. Control of these sprays is important as the spray details can control both rocket combustion stability and efficiency. Under the present study Imperial College considered the following: (1) Measurement of the size and rate of spread of the sprays produced by single coaxial airblast nozzles with axial gaseous stream. The local size, velocity, and flux characteristics for a wide range of gas and liquid flowrates were measured, and the results were correlated with the conditions of the spray at the nozzle exit. (2) Examination of the effect of the geometry of single coaxial airblast atomizers on spray characteristics. The gas and liquid tube diameters were varied over a range of values, the liquid tube recess was varied, and the shape of the exit of the gaseous jet was varied from straight to converging. (3) Quantification of the effect of swirl in the gaseous stream on the spray characteristics produced by single coaxial airblast nozzles. (4) Quantification of the effect of reatomization by impingement of the spray on a flat disc positioned around 200 mm from the nozzle exit. This models spray impingement on the turbopump dome during the startup process of the preburner of the SSME. (5) Study of the interaction between multiple sprays without and with swirl in their gaseous stream. The spray characteristics of single nozzles were compared with that of three identical nozzles with their axis at a small distance from each other. This study simulates the sprays in the preburner of the SSME, where there are around 260 elements on the faceplate of the combustion chamber. (6) Design an experimental facility to study the characteristics of sprays at high pressure conditions and at supercritical pressure and temperature for the gas but supercritical pressure and subcritical temperature for the liquid.

Hardalupas, Y.↗

Probability of brittle failure

A methodology was developed for collecting statistically representative data for crack initiation and arrest from small number of test specimens. An epoxy (based on bisphenol A diglycidyl ether and polyglycol extended diglycyl ether and cured with diethylene triamine) is selected as a model material. A compact tension specimen with displacement controlled loading is used to observe multiple crack initiation and arrests. The energy release rate at crack initiation is significantly higher than that at a crack arrest, as has been observed elsewhere. The difference between these energy release rates is found to depend on specimen size (scale effect), and is quantitatively related to the fracture surface morphology. The scale effect, similar to that in statistical strength theory, is usually attributed to the statistics of defects which control the fracture process. Triangular shaped ripples (deltoids) are formed on the fracture surface during the slow subcritical crack growth, prior to the smooth mirror-like surface characteristic of fast cracks. The deltoids are complementary on the two crack faces which excludes any inelastic deformation from consideration. Presence of defects is also suggested by the observed scale effect. However, there are no defects at the deltoid apexes detectable down to the 0.1 micron level.

Kim, A.↗