Submetering Resources: Commercial Buildings
This fact sheet summarizes resources available to commercial organizations to help them make the business case for and implement energy submetering.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This fact sheet summarizes resources available to commercial organizations to help them make the business case for and implement energy submetering.
Abstract Acoustic telemetry has been used extensively to study the behavior of aquatic animals. The Juvenile Salmon Acoustic Telemetry System (JSATS) is one such system; it was developed for studying juvenile salmonids but has been used to study numerous species. A recent innovation of the JSATS system is an acoustic transmitter that is small enough to be implanted through injection or small incision that doesn’t require sutures. Use of the JSATS system involves deploying cabled acoustic receivers at hydroelectric dams, or other structures, and autonomous acoustic receivers in free-flowing sections of a river. The raw detections from acoustic-tagged fish are processed to remove potential false positives. The clean detections (5,147,996 total) are used to generate detection events and to compute 3-D trajectories (403,900 total), which are used to assign fish to a passage route through a dam. Controlled field testing involving a high-accuracy Global Positioning System receiver is done to validate the submeter accuracy of the trajectories. The JSATS dataset could be reused for expanding the understanding of near-dam fish behavior.
Laboratory and field demonstration of circuit-level electrical submetering technology that utilizes wireless current transformers to monitor circuits within the panel. Report provides a background of the technology and how it works, outlines the testing methodology and presents results on measurement accuracy and ability of the technology to be rapidly integrated into both electrical panels/infrastructure and into an analytics platform. Cost effectiveness results are discussed for the specific field demonstration site.
Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level—split-core current transformers (CTs) and power monitoring meters—have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces (API). NREL evaluated Meazon’s single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.
This is a presentation for the Green Proving Ground (GPG) within GSA for a non-invasive low-cost strap on gas submeter.
Most lidars used for cloud observations have the range resolution of about 10 m, so they are incapable of resolving submeter-scale processes that are crucial to cloud evolution. This article describes a prototype of a ground-based, vertically pointing, time-gated, time-correlated single-photon-counting lidar (referred to as the T2 lidar) developed to explore atmospheric clouds at range resolution two orders of magnitude finer than traditional atmospheric lidars. The T2 lidar emits green-light pulses (532 nm) at a repetition rate of 20.6 kHz and a pulse width of ∼650 ps, which enables the observation of aerosol and cloud layers at heights from a few hundred meters to 7.28 km above the ground level at range resolution down to 10 cm. In addition, a digital delay pulse generator controls the detector to only receive photons for a short period after each laser pulse. This time-gated technique blocks photons arriving from regions outside the target zone, thus significantly reducing the noise level and allowing observation even inside clouds. Initial observations show that the T2 lidar can detect sharp cloud boundaries and fine structures near the cloud base. Such refined measurements of cloud structure could lead to an improved understanding of microphysical processes such as droplet activation, entrainment and mixing, and precipitation.
Orbits for satellites of the Global Positioning System (GPS) were determined with submeter accuracy. Tests used to assess orbital accuracy include orbit comparisons from independent data sets, orbit prediction, ground baseline determination, and formal errors. One satellite tracked 8 hours each day shows rms error below 1 m even when predicted more than 3 days outside of a 1-week data arc. Differential tracking of the GPS satellites in high Earth orbit provides a powerful relative positioning capability, even when a relatively small continental U.S. fiducial tracking network is used with less than one-third of the full GPS constellation. To demonstrate this capability, baselines of up to 2000 km in North America were also determined with the GPS orbits. The 2000 km baselines show rms daily repeatability of 0.3 to 2 parts in 10 to the 8th power and agree with very long base interferometry (VLBI) solutions at the level of 1.5 parts in 10 to the 8th power. This GPS demonstration provides an opportunity to test different techniques for high-accuracy orbit determination for high Earth orbiters. The best GPS orbit strategies included data arcs of at least 1 week, process noise models for tropospheric fluctuations, estimation of GPS solar pressure coefficients, and combine processing of GPS carrier phase and pseudorange data. For data arc of 2 weeks, constrained process noise models for GPS dynamic parameters significantly improved the situation.
The U.S. General Services Administration (GSA) is interested in installing internet-connected, gas submeters to better understand gas consumption in its portfolio of buildings. The GSA in partnership with the National Renewable Energy Laboratory conducted a demonstration to assess a specific submeter technology. This technology was implemented at two GSA separate facilities located in Dallas, Texas. This demonstration evaluated hardware and software installations and integrations, data integrity and accuracy, and included an economic analysis. This demonstration evaluated a gas submeter technology provided by the vendor Vata Verks, who produces a non-invasive strap-on submeter. The company was founded with a mission to conserve water (and eventually gas) cheaply and simply, as explained on its website. The product intends to streamline submeter deployments for gas and water by eliminating most hardware costs while allowing for easy integration of submetered data into other systems such as the Building Automation System and removing tenant and building disruption This demonstration evaluated the product features when used on a gas utility meter.
The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.
Charging data are collected from one of three sources, each with varying levels of additional information. These sources, in approximate order from most to least additional information, are: • The electric vehicle supply equipment (charger) • Onboard the vehicle itself • From a utility submeter. Many chargers provide software that allows for the collection and reporting of charging session data. If unavailable, data may be recorded by the charging vehicle’s onboard systems. If neither of these options is available, data can be acquired from utility submeters that simply track the energy flowing to one or more chargers. Data collected directly from the electric vehicle supply equipment (EVSE) are typically the most accurate and highest frequency. However, it is not always possible to discern which exact vehicle is being charged during any one session. EVSE-side data can be identified where a single charger ID but a range of vehicle IDs are present (e.g., CH001, EV001-EV005). Data collected from the vehicle’s onboard systems usually does not provide information on which exact charger is being used. Vehicle-side data can be identified where a single Vehicle ID but a range of Charger IDs are present (e.g., EV001, CH001-CH005). Data collected from utility submeters provide no information on which specific vehicle is charging or which specific charger is in use. Submeter data can be identified where multiple Vehicle IDs and multiple Charger IDs are present, but only a single Fleet ID is present (e.g., EV001-EV005, CH001-CH005, Fleet01). The **Charge Data Daily/Session Dictionaries** contains definitions for each available parameter collected as part of an individual charging session, aggregated at either a daily or session level. The parameters available will vary between vehicles and chargers. The **Charger Attributes** table contains specific charger characteristics, coded to at least one anonymous Charger ID and linked to either a single or a range of Vehicle IDs. Vehicle ID can be used as a key between charging data and vehicle attribute tables. The **Charger Attributes Data Dictionary** contains definitions for each available parameter collected on the physical and operational characteristics of the charging hardware itself. The **Vehicle Attributes Data Dictionary** contains definitions for each available parameter associated with a vehicle’s physical and functional attributes and fleet context. The **Vehicle Attributes** table contains specific vehicle characteristics, coded to an anonymous Vehicle ID. This Vehicle ID can be used as a key between vehicle data and vehicle attribute tables, and in cases where charging data are supplied, links a vehicle with the charger(s) that supplied it power. The **Charging Data** tables contain the data from each charger’s operations, coded to at least one anonymous Charger ID and linked to either a single or a range of Vehicle IDs. Vehicle ID can be used as a key between charging data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.
Submeter-scale geologic heterogeneity greatly affects CO 2 plume migration and retention. In this work, we present meter-scale laboratory experiments that can capture the impact of realistic submeter-scale geologic heterogeneity on multiphase flow and trapping. We produce realistic sedimentary formations consisting of ripple deposits with varying grain size contrast and wettability in a meter-scale slab chamber. Then, we conduct multiphase flow experiments with analog fluids through these structures and measure the saturation patterns, capillary heterogeneity trapping (CHT), and overall trapping performance. When we alter the ripple bedform architecture, variations in trapped saturation and CHT (10–20%) increment are exhibited. Similar growth in trapping performance is also observed when grain size contrast increases. Finally, wettability changes (water- to oil-wet) can increase nonwetting saturation and CHT up to 5% and 10–20%, respectively. These results emphasize the importance of correctly characterizing the impact of small-scale heterogeneities and wettability changes. We believe this is the first time that multiphase flow experiments were conducted in meter-scale domains with realistic ripple bedforms and heterogeneous wettability to investigate plume migration and trapping.
It was demonstrated that the submeter GPS (Global Positioning System) orbits can be determined using multiday arc solutions with the current GPS constellation subset visible for about 8 h each day from North America. Submeter orbit accuracy was shown through orbit repeatability and orbit prediction. North American baselines of 1000-2000 km length can be estimated simultaneously with the GPS orbits to an accuracy of better than 1.5 parts in 108 (3 cm over 2000 km distance) with a daily precision of two parts in 108 or better. The most reliable baseline solutions are obtained using the same type of receivers and antennas at each end of the baseline. Baselines greater than 1000 km distance from Florida to sites in the Caribbean region have also been determined with daily precision of 1-4 parts in 108. The Caribbean sites are located well outside the fiducial tracking network and the region of optimal GPS common visibility. Thus, these results further demonstrate the robustness of the multiday arc GPS orbit solutions.
We introduce a trilateration scheme that evaluates the 3-dimensional (3-D) relative position between a reference spacecraft and a target spacecraft using raw-range measurements from a distance baseline of known locations, which we call “anchors”. The anchors can be antennas of a ground-based network (e.g., Deep Space Network (DSN) or Near Earth Network (NEN) stations), or satellites of a spacebased network (e.g., global positioning system (GPS) or tracking and data relay satellite (TDRS)). We define raw-range as the range that includes all the systematic errors that occur during range measurements. A unique feature of this approach is that accurate relative position is derived from a “differencing function” of raw-range measurements of the reference spacecraft and target spacecraft, thereby eliminating most of the systematic errors, such as media effects, ephemeris errors, instrument delays, clock bias, etc. There can be an arbitrary number of target spacecraft, and relative positioning of target spacecraft with respect to the reference spacecraft can be done simultaneously. In this paper, we first assume an idealized system in which clocks on the reference and target spacecraft are synchronized, with clocks of the anchors synchronized as well. We develop a novel iterative algorithm that computes the relative position of the target spacecraft with respect to the reference spacecraft. We illustrate the relative positioning method using the scenario of a network of three ground stations (i.e., the anchors) at Goldstone, California, USA, Madrid, Spain, and Marlargue, Argentina tracking two spacecraft at geosynchronous orbit distance. We demonstrate that the algorithm converges to submeter accuracy in estimating the relative position, in the presence of random errors and systematic errors in raw-range measurements, and in the presence of angular errors in estimating the pointing vectors between the anchors and the reference spacecraft. Next, we relax the requirement of perfect time synchronization between spacecraft, and show that by using an additional anchor, one can estimate and remove the clock biases between the reference and target spacecraft. We add a ground station at Kourou to the above example of three ground stations of Goldstone, Madrid, and Marlargue, and demonstrate that the updated algorithm also converges to meter-level accuracy (submeter in some cases) in the presence of clock biases in addition to the random errors, systematic errors, and angular errors as shown in the above case. We compare this scheme with a similar trilateration scheme for relative positioning scheme first proposed by Montenbruck in 2002.
The End-Use Load Profiles for the U.S. Building Stock project uses New ResStock and ComStock models to statistically represent the energy use of U.S. buildings. The project's hybrid approach combines best-available ground truth data, such as submetering studies and statistical disaggregation of whole-building interval meter data, with the reach, cost-effectiveness, and granularity of physics-based and data-driven building stock modeling to deliver a nationally-comprehensive data set at a fraction of the historical cost.
B.V. Building commissioning (Cx) is a process for assuring efficient building operations that can be applied to new construction and existing buildings, resulting in energy and non-energy benefits. Quantifying the benefits of commissioning is challenging, but a 2009 study of 643 commercial buildings provided a solid initial data set to which we added 839 additional buildings for a significantly expanded and updated meta-analysis representing 34.7 million square meters (373 million square feet) of floor area. Since 2009 the commissioning industry has continued to grow, driven by building codes, utility programs, and rising awareness of commissioning benefits. In parallel, building controls have become more sophisticated, and analytics software has emerged to assist with commissioning. We find that delivery mechanism and market segment are key determinants of outcomes, although significant and cost-effective savings are found across the spectrum. Median primary energy savings for Cx projects in existing buildings ranged from 5 percent for those conducted under utility programs, 9 percent for monitoring-based commissioning utility programs (i.e., augmented with submetering and diagnostics), and 14 percent for Cx projects outside of utility programs. Across all project types, median savings ranged from 3 percent for the lodging market segment to 16 percent for public order and safety facilities. Outcomes did not vary significantly by building size or by market segment. Energy savings are rarely estimated for new construction commissioning. We found that the median costs of Cx were lower for the 2018 sample than for the 2009 sample—$\$$2.85 per square meter ($\$$0.26 per square foot) for existing buildings (a 33 percent reduction) and $\$$8.78 per square meter ($\$$0.82 per square foot) for new construction (a reduction of almost 50 percent). The median simple payback time for existing buildings was 1.7 years, with a 25th–75th percentile range of 0.8–3.5 years. Overall, this article summarizes these and other key findings, and discusses how the 2018 data reflects shifts in commissioning practice and outcomes.
Abstract Clouds, crucial for understanding climate, begin with droplet formation from aerosols, but observations of this fleeting activation step are lacking in the atmosphere. Here we use a time-gated time-correlated single-photon counting lidar to observe cloud base structures at decimeter scales. Results show that the air–cloud interface is not a perfect boundary but rather a transition zone where the transformation of aerosol particles into cloud droplets occurs. The observed distributions of first-arriving photons within the transition zone reflect vertical development of a cloud, including droplet activation and condensational growth. Further, the highly resolved vertical profile of backscattered photons above the cloud base enables remote estimation of droplet concentration, an elusive but critical property to understanding aerosol–cloud interactions. Our results show the feasibility of remotely monitoring cloud properties at submeter scales, thus providing much-needed insights into the impacts of atmospheric pollution on clouds and aerosol-cloud interactions that influence climate.
We developed a machine learning-based load disaggregation method to estimate the real-time output of individual appliances from the whole-house measurements. We first learn the important features associated with each type of appliances using the ground truth consumption data of individual appliances potentially available for a small set of houses equipped with submeters. The learned features are then be used to estimate the power generation/consumption of the appliances from the whole-house consumption. This developed load disaggregation software includes two steps. The first step is to identify the on/off status of different appliances using a classification method, and the second step is to estimate the appliance output using a regression method.
We report on the Azores Stratocumulus Measurements of Radiation, Turbulence and Aerosols (ACORES) campaign, which took place around Graciosa and Pico Islands/Azores in July 2017. The main objective was to investigate the vertical distribution of aerosol particles, stratocumulus microphysical and radiative properties, and turbulence parameters in the eastern North Atlantic. The vertical exchange of mass, momentum, and energy between the free troposphere (FT) and the cloudy marine boundary layer (MBL) was explored over a range of scales from submeters to kilometers. To cover these spatial scales with appropriate measurements, helicopter-borne observations with unprecedented high resolution were realized using the Airborne Cloud Turbulence Observation System (ACTOS) and Spectral Modular Airborne Radiation Measurement System–Helicopter-Borne Observations (SMART-HELIOS) instrumental payloads. Here, the helicopter-borne observations were combined with ground-based aerosol measurements collected at two continuously running field stations on Pico Mountain (2,225 m above sea level, in the FT), and at the Atmospheric Radiation Measurement (ARM) station on Graciosa (at sea level). First findings from the ACORES observations we are discussing in the paper are as follows: (i) we have observed a high variability of the turbulent cloud-top structure on horizontal scales below 100 m with local temperature gradients of up to 4 K over less than 1 m vertical distance, (ii) we have collected strictly collocated radiation measurements supporting the relevance of small-scale processes by revealing significant inhomogeneities in cloud-top brightness temperature to scales well below 100 m, and (iii) we have concluded that aerosol properties are completely different in the MBL and FT with often-complex stratification and frequently observed burst-like new particle formation.