Search NASA⌕ Search

SEARCH · Search NASA

Results for “submicrometer spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spectroscopic setup for submicrometer-resolution mapping of low-signal absorption and luminescence using photothermal heterodyne imaging and photon-counting techniques

A spectroscopic setup that enables one to map the absorption and photoluminescence with submicrometer spatial resolution and high sensitivity is described. Here a photothermal heterodyne imaging pump/probe technique is employed for absorption mapping, and low-signal, spatially resolved photoluminescence is recorded using photon counting. High-spatial-resolution mapping is accomplished by using high-numerical-aperture microscope objective focusing laser beams (pump and probe) into a submicrometer spot and raster-scanning sample mounted on the nanopositioning translation stage. Performance of the setup is illustrated by mapping absorption and luminescence of the hafnium oxide film with embedded hafnium nanoparticles and multilayer dielectric grating. In both cases submicrometer spatial resolution is demonstrated and possible physical mechanisms leading to image contrast on a submicrometer scale is discussed

47 OTHER INSTRUMENTATION↗

Sub-micrometer resolution proximity X-ray microscope with digital image registration

A compact laboratory proximity soft X-ray microscope providing submicrometer spatial resolution and digital image registration is described. The microscope consists of a laser-plasma soft X-ray radiation source, a Schwarzschild objective to illuminate the test sample, and a two-coordinate detector for image registration. Radiation, which passes through the sample under study, generates an absorption image on the front surface of the detector. Optical ceramic YAG:Ce was used to convert the X-rays into visible light. An image was transferred from the scintillator to a charge-coupled device camera with a Mitutoyo Plan Apo series lens. The detector’s design allows the use of lenses with numerical apertures of NA = 0.14, 0.28, and 0.55 without changing the dimensions and arrangement of the elements of the device. This design allows one to change the magnification, spatial resolution, and field of view of the X-ray microscope. A spatial resolution better than 0.7 μm and an energy conversion efficiency of the X-ray radiation with a wavelength of 13.5 nm into visible light collected by the detector of 7.2% were achieved with the largest aperture lens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring nanoscale thermal gradients in suspended MoS2 with STEM-EELS

Transition metal dichalcogenides such as molybdenum disulfide (MoS2) may see service in the heart of next-generation nanoelectronic devices, where highly localized power dissipation can produce nontrivial temperature gradients over nanometer-scale distances. Here, we demonstrate that MoS2 is a promising target for plasmon energy expansion thermometry (PEET), a high-spatial resolution temperature mapping technique employed in a scanning transmission electron microscope (STEM) equipped with electron energy loss spectroscopy (EELS). We first use a calibrated, commercial MEMS-style TEM sample heater chip to measure the temperature dependence of the MoS2 bulk plasmon. We corroborate the chip's temperature calibration with Raman thermometry and determine the bulk thermal expansion coefficient (TEC) of MoS2 in the temperature range of 300–1100 K. Applying this TEC value to PEET measurements on a suspended MoS2 flake, we map 70–90 K/μm temperature gradients with a submicrometer spatial resolution.

Shen, Lang (ORCID:0000000297554821)↗

Neutron and X-Ray Diffraction Studies of Advanced Materials

The selection of articles in the special topic 'Neutron and X-Ray Studies of Advanced Materials' is based on the materials presented during the TMS 2009 annual meeting in San Francisco, CA, February 15-19, 2009. The development of ultrabrilliant third-generation synchrotron X-ray sources, together with advances in X-ray optics, has created intense X-ray microbeams, which provide the best opportunities for in-depth understanding of mechanical behavior in a broad spectrum of materials. Important applications include ultrasensitive elemental detection by X-ray fluorescence/absorption and microdiffraction to identify phase and strain with submicrometer spatial resolution. X-ray microdiffraction is a particularly exciting application compared with alternative probes of crystalline structure, orientation, and strain. X-ray microdiffraction is nondestructive with good strain resolution, competitive or superior spatial resolution in thick samples, and with the ability to probe below the sample surface. Moreover, the high-energy X-ray diffraction technique provides an effective tool for characterizing the mechanical and functional behavior in various environments (temperature, stress, and magnetic field). At the same time, some neutron diffraction instruments constructed mainly for the purpose of engineering applications can be found at nearly all neutron facilities. The first generation-dedicated instruments designed for studying in-situ mechanical behavior have been commissioned and used, and industrial standards for reliable and repeatable measurements have been developed. Furthermore, higher penetration of neutron beams into most engineering materials provides direct measurements on the distribution of various stresses (i.e., types I, II, and III) beneath the surface up to several millimeters, even tens of millimeters for important industrial components. With X-ray and neutron measurements, it is possible to characterize material behavior at different length scales. It is predicted that the application of these techniques, in combination with theoretical simulations and numerical modeling, will lead to major breakthroughs in materials science in the foreseeable future, which will contribute to the development of materials technology and industrial innovation. Specifically, the use of these techniques provides bulk material properties that further augment new characterization tools including the increased use of atom probe tomography and high-resolution transmission electron microscopy systems. The combination of these techniques greatly assists the material property models that address multi-length-scale mechanisms. Different applications of diffuse scattering for understanding the fundamental materials properties are illustrated in the articles of Welberry et al., Goossens and Welberry, Campbell, Abe et al., Gilles et al., and Zhang et al. Analysis of thin films and two-dimensional structures is described in the articles of Gramlich et al., Brock et al., Vigliante et al., Kuzel et al., and Davydok et al. Recent advances in the line profile analysis are represented by the the articles of Scardi et al., Ungar et al., and Woo et al. Characterization of modern alloys is presented by the articles of Wollmershauser et al., Eidenberger et al., Garlea et al., Jia et al., Soulami et al., Wilson et al., and Wang et al. The collected articles are written by different scientific X-ray and neutron research groups. They represent a general trend in the development and application of diffraction techniques all over the world.

36 MATERIALS SCIENCE↗

Disordered long-range internal stresses in deformed copper and the mechanisms underlying plastic deformation

The strength of wavy glide metals increases dramatically during deformation as dislocations multiply and entangle, forming dense dislocation wall structures. Numerous competing models have been proposed for this process but experimental validation and guidance for further model development require new experimental approaches capable of resolving local stresses within the dislocation microstructure. We use three-dimensional X-ray microscopy combining submicrometer spatial resolution with diffracted-beam masking to make direct measurements of axial elastic strain (and thus stress) in individual dislocation cell walls and their adjacent cell interiors in heavily deformed copper. These spatially resolved measurements show broad, asymmetric distributions of dipolar stresses that directly discriminate between long-standing deformation models and demonstrate that the distribution of local stresses is statistically connected to the global behavior through simple rules.

36 MATERIALS SCIENCE↗

Quantum Imaging of Ferromagnetic van der Waals Magnetic Domain Structures at Ambient Conditions

Recently discovered 2D van der Waals magnetic materials, and specifically iron–germanium–telluride (Fe5GeTe2), have attracted significant attention both from a fundamental perspective and for potential applications. Key open questions concern their domain structure and magnetic phase transition temperature as a function of sample thickness and external field, as well as implications for integration into devices such as magnetic memories and logic. Here we address key questions using a nitrogen-vacancy center based quantum magnetic microscope, enabling direct imaging of the magnetization of Fe5GeTe2 at submicrometer spatial resolution as a function of temperature, magnetic field, and thickness. This quantum imaging technique provides noninvasive, high-sensitivity measurements with high spatial resolution under ambient conditions, making it particularly well suited for probing 2D magnets. We employ spatially resolved measures, including magnetization variance and cross-correlation, and find a significant spread in transition temperature yet with no clear dependence on thickness down to 15 nm. We also identify previously unknown stripe features in the optical as well as magnetic images, which we attribute to modulations of the constituting elements during crystal synthesis and subsequent oxidation. Our results suggest that the magnetic anisotropy in this material does not play a crucial role in their magnetic properties, leading to a magnetic phase transition of Fe5GeTe2 which is largely thickness-independent down to 15 nm. Our findings could be significant in designing future spintronic devices, magnetic memories, and logic with 2D van der Waals magnetic materials.

Bindu, Bindu [Hebrew University of Jerusalem, Isra↗

High-sensitivity strain mapping around epitaxial oxide nanostructures using scanning x-ray nanodiffraction.

The generation and presence of strain around nanostructures of oxides is a key to their growth, properties, and functions, but it has been a challenge to experimentally measure its sign, magnitude, and spatial distribution. Combining diffuse scattering with scanning x-ray nanodiffraction, we have mapped the strain distribution in an oxide-on-oxide nanopatterned structure with a high sensitivity (10{sup -4}) and a submicrometer spatial resolution. An edge-induced strain distribution is observed from a sample of CoFe{sub 2}O{sub 4} nanolines epitaxially grown on MgO substrate, which agrees quantitatively with the numerical simulations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-efficiency control of spin-wave propagation in ultra-thin yttrium iron garnet by the spin-orbit torque

We study experimentally with submicrometer spatial resolution the propagation of spin waves in microscopic waveguides based on the nanometer-thick yttrium iron garnet and Pt layers. We demonstrate that by using the spin-orbit torque, the propagation length of the spin waves in such systems can be increased by nearly a factor of 10, which corresponds to the increase in the spin-wave intensity at the output of a 10 μm long transmission line by three orders of magnitude. We also show that, in the regime, where the magnetic damping is completely compensated by the spin-orbit torque, the spin-wave amplification is suppressed by the nonlinear scattering of the coherent spin waves from current-induced excitations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Residual stress analysis of aluminum nitride piezoelectric micromachined ultrasonic transducers using Raman spectroscopy

In this study, the Raman biaxial stress coefficients K II and strain-free phonon frequencies ω 0 have been determined for the E 2 (low), E 2 (high), and A 1 (LO) phonon modes of aluminum nitride, AlN, using both experimental and theoretical approaches. The E 2 (high) mode of AlN is recommended for the residual stress analysis of AlN due to its high sensitivity and the largest signal-to-noise ratio among the studied modes. The E 2 (high) Raman biaxial stress coefficient of ₋3.8 cm₋1/GPa and strain-free phonon frequency of 656.68 cm ₋1 were then applied to perform both macroscopic and microscopic stress mappings. For macroscopic stress evaluation, the spatial variation of residual stress was measured across an AlN-on-Si wafer prepared by sputter deposition. A cross-wafer variation in residual stress of ~150 MPa was observed regardless of the average stress state of the film. Microscopic stress evaluation was performed on AlN piezoelectric micromachined ultrasonic transducers (pMUTs) with submicrometer spatial resolution. These measurements were used to assess the effect of device fabrication on residual stress distribution in an individual pMUT and the effect of residual stress on the resonance frequency. At ~20 μm directly outside the outer edge of the pMUT electrode, a large lateral spatial variation in residual stress of ~100 MPa was measured, highlighting the impact of metallization structures on residual stress in the AlN film.

36 MATERIALS SCIENCE↗

Direct imaging of shock wave splitting in diamond at Mbar pressure

Understanding the behavior of matter at extreme pressures of the order of a megabar (Mbar) is essential to gain insight into various physical phenomena at macroscales—the formation of planets, young stars, and the cores of super-Earths, and at microscales—damage to ceramic materials and high-pressure plastic transformation and phase transitions in solids. Under dynamic compression of solids up to Mbar pressures, even a solid with high strength exhibits plastic properties, causing the induced shock wave to split in two: an elastic precursor and a plastic shock wave. This phenomenon is described by theoretical models based on indirect measurements of material response. The advent of x-ray free-electron lasers (XFELs) has made it possible to use their ultrashort pulses for direct observations of the propagation of shock waves in solid materials by the method of phase-contrast radiography. However, there is still a lack of comprehensive data for verification of theoretical models of different solids. Here, we present the results of an experiment in which the evolution of the coupled elastic–plastic wave structure in diamond was directly observed and studied with submicrometer spatial resolution, using the unique capabilities of the x-ray free-electron laser (XFEL). The direct measurements allowed, for the first time, the fitting and validation of the 2D failure model for diamond in the range of several Mbar. Our experimental approach opens new possibilities for the direct verification and construction of equations of state of matter in the ultra-high-stress range, which are relevant to solving a variety of problems in high-energy-density physics.

36 MATERIALS SCIENCE↗

Measuring the Lower Critical Field of Superconductors Using Nitrogen-Vacancy Centers in Diamond Optical Magnetometry

The lower critical magnetic eld, H c1 , of superconductors is measured by using ensembles of NV-centers-in-diamond optical magnetometry. The technique is minimally invasive, and has sub- gauss eld sensitivity and submicrometer spatial resolution, which allow for accurate detection of the vector eld at which the vortices start penetrating the sample from the corners. Aided by the revised calculations of the effective demagnetization factors of actual cuboid - shaped samples, H c1 and the London penetration depth, λ, derived from H c1 can be obtained. We apply this method to three well-studied superconductors: optimally doped Ba(Fe 1-x Co x ) 2 As 2 , stoichiometric CaKFe 4 As 4 , and high-Tc cuprate YBa 2 Cu 3 O 7-δ . Our results are well compared with the values of λ obtained using other techniques, thus adding another non-destructive and sensitive method to measure these important parameters of superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron and X-Ray Studies of Advanced Materials V: CENTENNIAL Symposium

In 2012 the diffraction community will celebrate 100 years since the prediction of X-ray diffraction by M. Laue, and following his suggestion the first beautiful diffraction experiment by W. Friedrich and P. Knipping. The significance of techniques based on the analysis of the diffraction of X-rays, neutrons, electrons and Mossbauer photons discovered later, has continued to increase in the past 100 years. The aim of this symposium is to provide a forum for discussion of using state-of-the-art neutron and X-ray scattering techniques for probing advanced materials. These techniques have been widely used to characterize materials structures across all length scales, from atomic to nano, meso, and macroscopic scales. With the development of sample environments, in-situ experiments, e.g., at temperatures and applied mechanical load, are becoming routine. The development of ultra-brilliant third-generation synchrotron X-ray sources, together with advances in X-ray optics, has created intense X-ray microbeams, which provide the best opportunities for in-depth understanding of mechanical behavior in a broad spectrum of materials. Important applications include ultra-sensitive elemental detection by X-ray fluorescence/absorption and microdiffraction to identify phase and strain with submicrometer spatial resolution. X-ray microdiffraction is a particularly exciting application compared with alternative probes of crystalline structure, orientation and strain. X-ray microdiffraction is non-destructive with good strain resolution, competitive or superior spatial resolution in thick samples, and with the ability to probe below the sample surface. Advances in neutron sources and instrumentation also bring new opportunities in neutron scattering research. In addition to characterizing the structures, neutrons are also a great tool for elucidating the dynamics of materials. Because neutrons are highly penetrating, neutrons have been used to map stress in engineering systems. Neutrons have also played a vital role in our understanding of the magnetism and magnetic properties. Specialized instruments have been built to gain physical insights of the fundamental mechanisms governing phase transformation and mechanical behaviors of materials. The application of those techniques, in combination with theoretical simulations and numerical modeling, will lead to major breakthroughs in materials science in the foreseeable future that will contribute to the development of materials technology and industrial innovation.

36 MATERIALS SCIENCE↗

Polymeric spatial resolution test patterns for mass spectrometry imaging using nano-thermal analysis with atomic force microscopy

As the spatial resolution of mass spectrometry imaging technologies has begun to reach into the nanometer regime, finding readily available or easily made resolution reference materials has become particularly challenging for molecular imaging purposes. This study describes the fabrication, characterization and use of vertical line array polymeric spatial resolution test patterns for nano-thermal analysis/atomic force microscopy/mass spectrometry chemical imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Broadband Fourier-Transform Optical Photothermal Infrared Spectroscopy and Imaging

Infrared (IR) spectroscopy is a powerful method for mapping chemical heterogeneity on the microscale. Synchrotron IR radiation uniquely provides a high brightness and broad bandwidth to further extend the capabilities of IR spectroscopic imaging. However, the diffraction-limited spatial resolution of IR spectroscopy is insufficient for studies requiring submicrometer spatial differentiation. Optical photothermal IR (O-PTIR) microscopy is a powerful, emerging method that overcomes the IR diffraction limit in IR hyperspectral imaging by employing a modulated IR beam and a visible probe laser beam to detect local temperature-induced modulation at the visible diffraction limit. In this work, we extend the spectral range of photothermal infrared measurements by incorporating a synchrotron IR source, demonstrating a combined synchrotron-based O-PTIR modality that enables high spatial resolution far-field chemical imaging spanning the entire mid-IR range. Both optical- and fluorescence-detected photothermal modalities were performed using a step-scan interferometer, demonstrating improved spectral range (541-4000 cm-1) when compared to optical photothermal microscopy with commercial laser sources (800-1800 cm-1 for this particular source) and improved spatial resolution, when compared to synchrotron microspectroscopy measurements. Following these initial validation studies, synchrotron Fourier-transform fluorescence-detected photothermal IR spectroscopy in combination with synchrotron microspectroscopy measurements was used to differentiate cells in mouse brain tissue sections, which requires submicron spatial resolutions beyond those accessible by IR spectroscopy alone.

Razumtcev, Aleksandr↗

Scalable submicrometer additive manufacturing

High-throughput fabrication techniques for generating arbitrarily complex three-dimensional structures with nanoscale features are desirable across a broad range of applications. Two-photon lithography (TPL)–based submicrometer additive manufacturing is a promising candidate to fill this gap. However, the serial point-by-point writing scheme of TPL is too slow for many applications. Attempts at parallelization either do not have submicrometer resolution or cannot pattern complex structures. We overcome these difficulties by spatially and temporally focusing an ultrafast laser to implement a projection-based layer-by-layer parallelization. This increases the throughput up to three orders of magnitude and expands the geometric design space. We demonstrate this by printing, within single-digit millisecond time scales, nanowires with widths smaller than 175 nanometers over an area one million times larger than the cross-sectional area.

36 MATERIALS SCIENCE↗

Improved Ga grading of sequentially produced Cu(In,Ga)Se{sub 2} solar cells studied by high resolution X-ray fluorescence

There is particular interest to investigate compositional inhomogeneity of Cu(In,Ga)Se{sub 2} solar cell absorbers. We introduce an approach in which focused ion beam prepared thin lamellas of complete solar cell devices are scanned with a highly focused synchrotron X-ray beam. Analyzing the resulting fluorescence radiation ensures high resolution compositional analysis combined with high spatial resolution. Thus, we are able to detect subtle variations of the Ga/(Ga + In) ratio down to 0.01 on a submicrometer scale. We observed that for sequentially processed solar cells a higher selenization temperature leads to absorbers with almost homogenous Ga/(Ga + In) ratio, which significantly improved the conversion efficiency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing Photon Reabsorption in Quantum Dot-Polymer Composites for Use as Displacement Sensors

The reabsorption of photoluminescence within a medium, an effect known as the inner filter effect (IFE), has been well studied in solutions, but has garnered less attention in regards to solid-state nanocomposites. Photoluminescence from a quantum dot (QD) can selectively excite larger QDs around it resulting in a net red-shift in the reemitted photon. In CdSe/CdS core/shell QD-polymer nanocomposites, we observe a large spectral red-shift of over a third of the line width of the photoluminescence of the nanocomposites over a distance of 100 μm resulting from the IFE. Unlike fluorescent dyes, which do not show a large IFE red-shift, QDs have a component of inhomogeneous broadening that originates from their size distribution and quantum confinement. By controlling the photoluminescence broadening as well as the sample dispersion and concentration, we show that the magnitude of the IFE within the nanocomposite can be tuned. We further demonstrate that this shift can be exploited in order to spectroscopically monitor the vertical displacement of a nanocomposite in a fluorescence microscope. Large energetic shifts in the measured emission with displacement can be maximized, resulting in a displacement sensor with submicrometer resolution. We further show that the composite can be easily attached to biological samples and is able to measure deformations with high temporal and spatial precision.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Submicrometer-Resolution Mapping of Ultraweak 355-nm Absorption in HfO2 Monolayers Using Photothermal Heterodyne Imaging

Nanosecond-pulse UV-laser-damage initiation in multilayer coatings comprised from metal oxide as a high-index component, and silica oxide as a low-index material, is strongly linked to metal oxide. The nature of the absorbing species and their physical properties remain unknown because of extremely small sizes. Previous experimental evidence provided by high-resolution mapping of damage morphology points to a few-nanometer scale of these absorbers. This work demonstrates submicrometer mapping of 355-nm absorption in HfO2 monolayers using a recently developed photothermal heterodyne imaging technique. Comparison of absorption maps with spatial distribution of UV pulsed-laser–induced damage morphology allows one to better estimate the size and densities of nanoscale absorbing defects in hafnia thin films. Possible defect-formation mechanisms are discussed.

laser-induced damage↗