Search NASA⌕ Search

SEARCH · Search NASA

Results for “submicron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Laser scattering by submicron droplets formed during the electrical explosion of thin metal wires

Abstract This paper presents the results of studying dispersed media formation during the electrical explosion of thin metal wires in vacuum by using low-current generators (~1–10 kA). Particular attention is paid to the analysis of the composition and structure of the corresponding explosion products as well as to the problem of their visualization using simultaneous laser interferometry and shadow imaging at two wavelengths (1.064 µ m and 0.532 µ m). Our findings indicate the important role in the visualization of the explosion products that belongs to multiple scattering by submicron droplets of dense condensed matter, which are mixed with metal vapor. The hypothesis on the existence of submicron droplets in the products of exploding metal wires correlates with the results obtained by soft x-ray radiography combined with a laser probing technique. Taking into account the multiple scattering by submicron droplets, it is possible to significantly clarify the parameters of the explosion products visualized via laser probing techniques as well as to gain a deeper insight into the physics behind the electrical wire explosion.

Physics↗

Evaluating Model Parameterizations of Submicron Aerosol Scattering and Absorption with in situ Data from ARCTAS 2008

Accurate modeling of the scattering and absorption of ultraviolet and visible radiation by aerosols is essential for accurate simulations of atmospheric chemistry and climate. Closure studies using in situ measurements of aerosol scattering and absorption can be used to evaluate and improve models of aerosol optical properties without interference from model errors in aerosol emissions, transport, chemistry, or deposition rates. Here we evaluate the ability of four externally mixed, fixed size distribution parameterizations used in global models to simulate submicron aerosol scattering and absorption at three wavelengths using in situ data gathered during the 2008 Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) campaign. The four models are the NASA Global Modeling Initiative (GMI) Combo model, GEOS-Chem v9- 02, the baseline configuration of a version of GEOS-Chem with online radiative transfer calculations (called GC-RT), and the Optical Properties of Aerosol and Clouds (OPAC v3.1) package. We also use the ARCTAS data to perform the first evaluation of the ability of the Aerosol Simulation Program (ASP v2.1) to simulate submicron aerosol scattering and absorption when in situ data on the aerosol size distribution are used, and examine the impact of different mixing rules for black carbon (BC) on the results. We find that the GMI model tends to overestimate submicron scattering and absorption at shorter wavelengths by 10-23 percent, and that GMI has smaller absolute mean biases for submicron absorption than OPAC v3.1, GEOS-Chem v9-02, or GC-RT. However, the changes to the density and refractive index of BC in GCRT improve the simulation of submicron aerosol absorption at all wavelengths relative to GEOS-Chem v9-02. Adding a variable size distribution, as in ASP v2.1, improves model performance for scattering but not for absorption, likely due to the assumption in ASP v2.1 that BC is present at a constant mass fraction throughout the aerosol size distribution. Using a core-shell mixing rule in ASP overestimates aerosol absorption, especially for the fresh biomass burning aerosol measured in ARCTAS-B, suggesting the need for modeling the time-varying mixing states of aerosols in future versions of ASP.

Alvarado, Matthew J.↗

Identifying a regional aerosol baseline in the eastern North Atlantic using collocated measurements and a mathematical algorithm to mask high-submicron-number-concentration aerosol events

Abstract. High-time-resolution measurements of in situ aerosol and cloud properties provide the ability to study regional atmospheric processes that occur on timescales of minutes to hours. However, one limitation to this approach is that continuous measurements often include periods when the data collected are not representative of the regional aerosol. Even at remote locations, submicron aerosols are pervasive in the ambient atmosphere with many sources. Therefore, periods dominated by local aerosol should be identified before conducting subsequent analyses to understand aerosol regional processes and aerosol–cloud interactions. Here, we present a novel method to validate the identification of regional baseline aerosol data by applying a mathematical algorithm to the data collected at the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) user facility in the eastern North Atlantic (ENA). The ENA central facility (C1) includes an aerosol observing system (AOS) for the measurement of aerosol physical, optical, and chemical properties at time resolutions from seconds to minutes. A second temporary supplementary facility (S1), located ∼0.75 km from C1, was deployed for ∼1 year during the Aerosol and Cloud Experiments (ACE-ENA) campaign in 2017. First, we investigate the local aerosol at both locations. We associate periods of high submicron number concentration (Ntot) in the fine-mode condensation particle counter (CPC) and size distributions from the Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) as a function of wind direction using a meteorology sensor with local sources. Elevated concentrations of Aitken-mode (< 100 nm diameter) particles were observed in correspondence with the wind directions associated with airport operations. At ENA, the Graciosa Airport and its associated activities were found to be the main sources of high-concentration aerosol events at ENA, causing peaks in 1 min Ntot that exceeded 8000 and 10 000 cm−3 at C1, in summer and winter, respectively, and 5000 cm−3 at S1 in summer. Periods with high Ntot not associated with these wind directions were also observed. As a result, the diverse local sources at ENA yielded a poor relationship between Ntot measurements collected at C1 and S1 (R2=0.03 with a slope =0.05±0.001). As a first approach to mask these events, the time periods when the wind direction was associated with the airport operations (west to northwest and southeast to south at C1 and east to south at S1) were applied. The meteorological masks removed 38.9 % of the data at C1 and 43.4 % at S1, and they did not significantly improve the relationship between the two sites (R2=0.18 with a slope =0.06±0.001). Due to the complexity of high-Ntot events observed at ENA, we develop and validate a mathematical ENA Aerosol Mask (ENA-AM) to identify high-Ntot events using 1 min resolution data from the AOS CPC at C1 and S1. After its parameterization and application, ENA-AM generated a high correlation between Ntot in the summer at C1 and S1 (R2=0.87 with a slope =0.84±0.001). We identified the regional baseline at ENA to be 428±228 cm−3 in the summer and 346±223 cm−3 in the winter. Lastly, we compared masked measurements from the AOS with the ARM Aerial Facility (AAF) during flights over C1 in the summer to understand submicron aerosol vertical mixing over C1. The high correlation (R2=0.71 with a slope of 1.04±0.01) observed between C1 and the AAF Ntot collected within an area of 10 km surrounding ENA and at altitudes < 500 m indicated that the submicron aerosol at ENA was well mixed within the first 500 m of the marine boundary layer during the month of July during ACE-ENA. Our novel method for determining a regional aerosol baseline at ENA can be applied to other time periods and at other locations with validation by a secondary site or additional collocated measurements.

54 ENVIRONMENTAL SCIENCES↗

Investigation of the enhanced spatial density of submicron lunar ejecta between L values 1.2 and 3.0 in the earth's magnetosphere: Theory

Initial results from the measurement conducted by the dust particle experiment on the lunar orbiting satellite Lunar Explorer 35 (LE 35) were reported with the data interpreted as indicating that the moon is a significant source of micrometeroids. Primary sporadic and stream meteoroids impacting the surface of the moon at hypervelocity was proposed as the source of micron and submicron particles that leave the lunar craters with velocities sufficient to escape the moon's gravitational sphere of influence. No enhanced flux of lunar ejecta with masses greater than a nanogram was detected by LE 35 or the Lunar Orbiters. Hypervelocity meteoroid simulation experiments concentrating on ejecta production combined with extensive analyses of the orbital dynamics of micron and submicron lunar ejecta in selenocentric, cislunar, and geocentric space have shown that a pulse of these lunar ejecta, with a time correlation relative to the position of the moon relative to the earth, intercepts the earth's magnetopause surface (EMPs). As shown, a strong reason exists for expecting a significant enhancement of submicron dust particles in the region of the magnetosphere between L values of 1.2 and 3.0. This is the basis for the proposal of a series of experiments to investigate the enhancement or even trapping of submicron lunar ejecta in this region. The subsequent interaction of this mass with the upper-lower atmosphere of the earth and possible geophysical effects can then be studied.

Alexander, W. M.↗

Extensive urban air pollution footprint evidenced by submicron organic aerosols molecular composition

Transport and transformation of urban air pollutants are among the major factors driving the changes in the atmospheric composition in the downwind rural/remote areas of a megacity. Here, we assess the impacts of urban air pollution in a subtropical forest through characterization of the organic markers in submicron aerosol particles. The aerosol samples were collected and analyzed using TD-PTR-ToF-MS, where 163 ions were detected. The concentration of these extracted ions accounts for 83% of the mass of submicron organic aerosols, which are accordingly characterized by a median formula of C 7 H 10 O 2 . Molecular speciation indicates that urban and biomass burning pollution contributed substantially to the budget of organic aerosols, which were enhanced particularly by the liquid water content and acidity of the aerosols. Our results evidence that the footprint of urban air pollution was extended to its downwind forested areas and caused changes in the concentration and composition of submicron aerosols.

54 ENVIRONMENTAL SCIENCES↗

Retrieval of the sea spray aerosol mode from submicron particle size distributions and supermicron scattering during LASIC

Abstract. Improved quantification of sea spray aerosol concentration and size is important for determining aerosol effects on clouds and the climate, though attempts to accurately capture the size distribution of the sea spray mode remain limited by the availability of supermicron size distributions. In this work, we introduce a new approach to retrieving lognormal mode fit parameters for a sea spray aerosol mode by combining submicron size distributions with supermicron scattering measurements using a Mie inversion. Submicron size distributions were measured by an ultra-high-sensitivity aerosol spectrometer (UHSAS), and supermicron scattering was taken as the difference between <10 µm and <1 µm three-wavelength integrating nephelometer measurements (NEPH). This UHSAS-NEPH method was applied during background marine periods of the Department of Energy Atmospheric Radiation Measurement Layered Atlantic Smoke Interactions with Clouds (LASIC) campaign on Ascension Island (November 2016–May 2017), when the contribution of sea spray aerosol was expected to represent a large fraction of the aerosol mass and total scattering. Lognormal sea spray modal parameters were retrieved from comparisons between nephelometer measurements and a lookup table of Mie theory-simulated scattering coefficients for low-error solutions that minimized the 0.4–1 µm residual in the UHSAS size distribution. We evaluated the UHSAS-NEPH method with a set of clean marine measurements in the North Atlantic that included supermicron size and chemical measurements, showing that measured supermicron size distributions are needed to constrain the sea spray number concentration but that mass concentration was reasonably characterized using supermicron scattering. For LASIC, the UHSAS-NEPH method retrieved sea spray mode properties for approximately 88 % of the background marine times when the scattering variability and total particle concentration were low (<± 5 Mm−1 and <400 cm−3, respectively), with mass mean diameter ranging from 0.6 to 1.9 µm (1.47 ± 0.17 µm), modal width ranging from 1.1 to 3.97 (2.4±0.3), and mass concentration ranging from 0.18 to 23.0 µg m−3 (8.37. ± 4.1 µg m−3). The measured nephelometer scattering at three wavelengths was found to constrain the mode width marginally at the largest particle sizes in the absence of additional size and chemical measurements for defining parameters for the Mie solutions. Comparing UHSAS-NEPH retrievals to those of a fitting algorithm applied only to the submicron UHSAS number size distribution showed that correlations between retrieved mass concentration and the available mass-based sea spray tracers (coarse scattering, wind speed, and chloride) are low when supermicron measurements are not considered. This work demonstrates the added value of supermicron scattering measurements for retrieving reasonable sea spray mass concentrations, providing the best-available observationally constrained estimate of the sea spray mode properties when supermicron size distribution measurements are not available.

54 ENVIRONMENTAL SCIENCES↗

Nanoscopic Plugs Block Hydrogen Crossover in Submicron Thick Proton-Conducting SiO 2 Membranes for Water Electrolysis

Zero-gap electrolyzers based on submicron thick proton-conducting oxide membranes (POMs) represent a promising approach to increasing the efficiency of H 2 production from water electrolysis while moving away from conventional perfluorosulfonic acid (PFSA) membranes. A critical barrier to the commercialization of such electrolyzers is that the ultrathin nature of POMs, which is necessary to achieve low cell resistance, makes them more susceptible to defects that can lead to unacceptably high rates of H 2 crossover. Herein, we demonstrate an approach to mitigate this problem through selective deposition of carbon-containing silicon oxide (SiO x C y ) “nanoplugs” into the defects of submicron thick SiO 2 membranes using a facile electrochemically mediated deposition process. Selective deposition of nanoplugs within the defects was verified by multiple characterization techniques, while scanning electrochemical microscopy (SECM) was used to confirm selective plugging of H 2 -crossover hotspots associated with defects at identical locations. Thanks to the use of nanoplugs, the H 2 permeance of 250 nm thick SiO 2 membranes was reduced by 5 to 6 orders of magnitude compared to the unmodified atomic layer deposition (ALD) SiO 2 membranes while having negligible impact on the ionic resistance of the membrane. These plug-modified membranes also enabled safe and stable operation of a zero-gap full cell electrolysis cell, in contrast to cells lacking nanoplugs that produced anode effluent streams having H 2 concentrations near or exceeding the lower flammability limit (LFL) of H 2 . Furthermore, beyond water electrolysis, this defect-sealing strategy has the potential to be broadly implemented in other applications, such as fuel cells and flow batteries, offering a versatile solution to mitigate crossover-related performance losses.

ALD SiO2↗

Estimating Submicron Aerosol Mixing State at the Global Scale With Machine Learning and Earth System Modeling

Abstract This study integrates machine learning and particle‐resolved aerosol simulations to develop emulators that predict submicron aerosol mixing state indices from the Earth system model (ESM) simulations. The emulators predict aerosol mixing state using only quantities that are predicted by the ESM, including bulk aerosol species concentrations, which do not by themselves carry mixing state information. We used PartMC‐MOSAIC as the particle‐resolved model and NCAR's CESM as the ESM. We trained emulators for three different mixing state indices for submicron aerosol in terms of chemical species abundance ( χ a ), the mixing of optically absorbing and nonabsorbing species ( χ o ), and the mixing of hygroscopic and nonhygroscopic species ( χ h ). Our global mixing state maps show considerable spatial and seasonal variability unique to each mixing state index. Seasonal averages varied spatially between 13% and 94% for χ a , between 38% and 94% for χ o , and between 20% and 87% for χ h with global annual averages of 67%, 68%, and 56%, respectively. High values in one index can be consistent with low values in another index depending on the grouping of species and their relative abundance, meaning that each mixing state index captures different aspects of the population mixing state. Although a direct validation with observational data has not been possible yet, our results are consistent with mixing state index values derived from ambient observations. This work is a prototypical example of using machine learning emulators to add information to ESM simulations.

54 ENVIRONMENTAL SCIENCES↗

Efficiency cliff in scaling InGaN light-emitting diodes down to submicron

The top-down submicron fabrication of blue-emitting light-emitting diodes on Qromis Substrate Technology substrates is reported. Light-emitting diodes with mesa sizes as small as 250 × 250 nm 2 show ideal forward voltage and low leakage current density. It is observed that sidewall treatment and passivation methods used in micro-light-emitting diodes (2–20 μ m) do not lead to the same level of sidewall recombination suppression for submicron ones (< 1 μ m), as evidenced by a ∼70% decrease in peak external quantum efficiencies when mesa sizes are scaled from 2 μ m down to 250 nm. This is attributed to the lateral carrier diffusion being comparable to the mesa size, regardless of the sidewall passivation and recovery. The results call for rethinking the impact of sidewalls in emerging top-down fabricated (sub)micrometer-light-emitting diodes.

42 ENGINEERING↗

Exploring the origins of the indentation size effect at submicron scales

Significance Downscaling material structure into ever-decreasing levels for modern technological advancements demands small-scale mechanical characterizations of materials, such as nanoindentation. Thus, a comprehensive understanding of indentation size effect (ISE) has a far-reaching impact, but such understanding remains incomplete at the submicron scale despite a decades-long quest since the 1980s. Here, we explored the origins of this effect experimentally by linking dislocation behavior evolution with nanoindentation mechanical data at various depths. Importantly, the dislocation behavior is found to be strongly depth dependent and gives rise to subgrain formation progressively. Aided by subgrain boundaries, the ISE mechanism transitions from dislocation source starvation to dislocation interaction as indentation depth increases. The critical mechanism transition elucidates the distinctive ISE behavior at the submicron scale.

36 MATERIALS SCIENCE↗

The effect of submicron grain size on thermal stability and mechanical properties of high-entropy carbide ceramics

(Hf 0.2 Zr 0.2 Ta 0.2 Nb 0.2 Ti 0.2 )C high-entropy ceramics (HEC) with a submicron grain size of 400 to 600 nm were fabricated by spark plasma sintering using a two-step sintering process. Both X-ray and neutron diffractions confirmed the formation of single-phase with rock salt structure in the as-fabricated (Hf 0.2 Zr 0.2 Ta 0.2 Nb 0.2 Ti 0.2 )C samples. The effect of submicron grain size on the thermal stability and mechanical properties of HEC was investigated. The grain growth kinetics in the fine-grained HEC was small at 1300 and 1600°C, suggesting high thermal stability that was possibly related to the compositional complexity and sluggish diffusion in HEC. Compared to the coarse-grain HEC with a grain size of 16.5 µm, the bending strength and fracture toughness of fine-grained HEC were 25% and 20% higher respectively. The improvement of mechanical properties in fine-grained HEC may be attributed to micromechanistic mechanisms such as crack deflection.

36 MATERIALS SCIENCE↗

Investigations of submicron sized metal particles in glass coatings of lunar breccia 15286

Almost all the submicron metal particles in the glass coating of breccia 15286 are rounded and contain two phases, metal and sulfide (FeS). The Ni content of the metal phase as determined by scanning transmission electron microscope X-ray analysis ranged from 9.4 to 15.5 wt %. The sulfide was nearly stoichiometric troilite containing up to 1.3 wt % Ni. The close chemical and microstructural similarities between the coarse (greater than 1-micron) and the submicron sized metal indicate a common origin probably as meteoritic debris. Metal-silicate melt experiments under controlled oxygen partial pressured indicate that the metal particles may have formed from a fine dispersion of immiscible metal-sulfide droplets into an impact-generated silicate melt.

Mehta, S.↗

Submicron-Particle Generator

Particle generator supplies submicron-size particles to high-pressure airstream. Particles serve as light scatterers in laser velocimeter for ultra-high-speed gas. Advantage of generator: produces cloud of uniform, submicron particles at high ambient pressures and high flow rates.

Morrisette, E.↗

Comets produce submicron particles in the solar system

Observational evidence for the existence of submicron particles issuing from meteor streams and comets is examined. The MTS Explorer 46 carried a meteoroid detector which measured the rate of impact of particles with masses on the order of 10 to the -16th gram. Particle enhancements were observed in association with meteor streams, such as the Taurid and Orionids. The ratio of radiation pressure to gravity is employed to examine the effects of radiation pressure on the particles. When the ratio is higher than one, particles become smaller, unless they are dielectrics. Particles with radii less than 0.1 micron, having a potential of +3.3 V, are projected to have a lifetime of about 3 yr. Several thousands of tons of submicron particles are expected to be produced during a cometary perihelion passage. Launch of a long duration exposure facility with the Shuttle is recommended for studies of the decay of the particles over time.

Singer, S. F.↗

Contact ice nucleation by submicron atmospheric aerosols

An apparatus designed to measure the concentrations of submicron contact ice nuclei is described. Here, natural forces transfer nuclei to supercooled sample drops suspended in an aerosol stream. Experimental measurements of the scavenging rate of the sample drops for several humidities and aerosol sizes are found to be in agreement with theory to within a factor of two. This fact, together with the statistical tests showing a difference between the data and control samples, is seen as indicating that a reliable measurement of the concentrations of submicron contact ice nuclei has been effected. A figure is included showing the ice nucleus concentrations as a function of temperature and assumed aerosol radius. For a 0.01 micron radius, the average is 1/liter at -15 C and 3/liter at -18 C. It is noted that the measurements are in fair agreement with ice crystal concentrations in stable winter clouds measured over Elk Mountain, WY (Vali et al., 1982).

Deshler, T.↗

Online submicron particle sizing by dynamic light scattering using autodilution

Efficient production of a wide range of commercial products based on submicron colloidal dispersions would benefit from instrumentation for online particle sizing, permitting real time monitoring and control of the particle size distribution. Recent advances in the technology of dynamic light scattering (DLS), especially improvements in algorithms for inversion of the intensity autocorrelation function, have made it ideally suited to the measurement of simple particle size distributions in the difficult submicron region. Crucial to the success of an online DSL based instrument is a simple mechanism for automatically sampling and diluting the starting concentrated sample suspension, yielding a final concentration which is optimal for the light scattering measurement. A proprietary method and apparatus was developed for performing this function, designed to be used with a DLS based particle sizing instrument. A PC/AT computer is used as a smart controller for the valves in the sampler diluter, as well as an input-output communicator, video display and data storage device. Quantitative results are presented for a latex suspension and an oil-in-water emulsion.

Nicoli, David F.↗