Search NASA⌕ Search

SEARCH · Search NASA

Results for “submillimeter wave imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

A compact submillimeter wave transmission / reflection measurement system has been demonstrated at 560-635 GHz, with electronic tuning over the entire band. Maximum dynamic range measured at a single frequency is 90 dB (60 dB typical), and phase noise is less than +/- 2(deg). By using a frequency steerable lens at the source output and mixer input, the frequency agility of the system can be used to scan the source and receive beams, resulting in near real-time imaging capability using only a single pixel.

submillimeter wave imaging↗

A compact 600 GHz electronically tunable vector measurement system for submillimeter wave imaging

A compact submillimeter wave transmission/reflection measurement system has been demonstrated at 560-635 GHz, with electronic tuning over the entire band. Maximum dynamic range measured at a single frequency is 100 dB (60 dB typical), and typical phase noise is less than +/- 1°. By using a frequency steerable lens at the source output and mixer input, the frequency agility of the system can be used to scan the source and receive beams, resulting in near realtime imaging capability using only a single pixel

Siegel, Peter H.↗

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

The design of a complete vector measurement system being tested over 560-635 GHz is presented. The topics include: 1) Current State-of-the-Art in Vector Measurements; 2) Submillimeter Active Imaging Requirements; 3) 600 GHz Vector Measurement System; 4) 450 MHz IF Signal; 5) 450 MHz IF signal @ 1 kHz Res. BW; 6) 450 MHz IF Signal Mixed with Shifted 450 MHz Reference Signal; 7) Reference Signal Offset Generator; 8) Cavity Bandpass Filter; 9) Miniature Multistage Helical Filter; 10) X36 450 MHz Multiplier; 11) 600 GHz Test Setup; 12) 600 GHz Transmit Module; 13) 600 GHz Receive Module; 14) Performance Tests: Amplitude Stability & Dynamic Range; 15) Performance Tests: Phase Stability; 16) Stability at Imaging Bandwidths; 17) Phase Measurement Verification; and 18) The Next Step: Imaging.

phase measurements↗

High Efficiency Submillimeter-Wave Imaging Array

The period of a focal array is limited by the angular sampling and the f number of the system. This fact will limit the efficiency of imaging array systems to around 50%. Recently it been demonstrated that the use of a dielectric layer on top of an array of apertures can improve this efficiency limit. In this paper, we describe a similar structure that improves the efficiency in imaging applications and that it is easy to manufacture due to its compatibility with planar lithographic techniques.

Llombart, Nuria↗

Imaging front-end systems for millimeter waves and submillimeter waves

Imaging (multi-beam) front-end systems utilize a reflector or a lens, as well as a focal-plane array of receptor elements (beams). To be practical, such systems must utilize focal plane arrays which can be fabricated using hybrid integrated (and eventually monolithic) technology. This paper reviews alternative approaches to focussing elements, auxiliary devices required for local oscillator injection and similar functions, and focal plane arrays. It also discusses general limitations and advantages of these approaches, as well as typical applications to millimeter and submillimeter astronomical instrumentation.

Yngvesson, K. S.↗

Three-Stage InP Submillimeter-Wave MMIC Amplifier

A submillimeter-wave monolithic integrated- circuit (S-MMIC) amplifier has been designed and fabricated using an indium phosphide (InP) 35-nm gate-length high electron mobility transistor (HEMT) device, developed at Northrop Grumman Corporation. The HEMT device employs two fingers each 15 micrometers wide. The HEMT wafers are grown by molecular beam epitaxy (MBE) and make use of a pseudomorphic In0.75Ga0.25As channel, a silicon delta-doping layer as the electron supply, an In0.52Al0.48As buffer layer, and an InP substrate. The three-stage design uses coplanar waveguide topology with a very narrow ground-to-ground spacing of 14 micrometers. Quarter-wave matching transmission lines, on-chip metal-insulator-metal shunt capacitors, series thin-film resistors, and matching stubs were used in the design. Series resistors in the shunt branch arm provide the basic circuit stabilization. The S-MMIC amplifier was measured for S-parameters and found to be centered at 320 GHz with 13-15-dB gain from 300-345 GHz. This chip was developed as part of the DARPA Submillimeter Wave Imaging Focal Plane Technology (SWIFT) program (see figure). Submillimeter-wave amplifiers could enable more sensitive receivers for earth science, planetary remote sensing, and astrophysics telescopes, particularly in radio astronomy, both from the ground and in space. A small atmospheric window at 340 GHz exists and could enable ground-based observations. However, the submillimeter-wave regime (above 300 GHz) is best used for space telescopes as Earth s atmosphere attenuates most of the signal through water and oxygen absorption. Future radio telescopes could make use of S-MMIC amplifiers for wideband, low noise, instantaneous frequency coverage, particularly in the case of heterodyne array receivers.

Pukala, David↗

CoSSIR: A New Instrument for Exploring the Utility of Submillimeter-wave Radiometry for Earth Observation

The Conical Scanning Submillimeter-wave Imaging Radiometer (CoSSIR) has been developed to study the application of submillimeter-wave radiometry for remote sensing of cirrus clouds and humidity sounding. Measurements of the global distribution of ice cloud mass and particle size are important for understanding the Earth s energy budget and for evaluating global climate models. The spatial variability and the wide variety of cloud particle shapes and sizes make ice clouds particularly difficult to measure. Ice clouds are essentially undetectable at microwave frequencies due to the low dielectric of ice and small size of the particles relative to wavelength. However, submillimeter wavelengths demonstrate significant response to the presence of ice clouds thus this frequency regime is applicable to measuring ice clouds. Another potentially viable application for submillimeter-wave radiometry is humidity and temperature sounding. The principle of sounding at submillimeter wavelengths is similar to that at microwavelengths. Submillimeter-wave radiometry has the advantage of achieving finer spatial resolution using a smaller antenna aperture which is an important consideration for spaceborne observatories. Submillimeter-wave radiometry also offers the potential of sounding over land and as a surrogate measurement for precipitation. CoSSIR is a new instrument to explore these applications. The CoSSIR is designed to fly aboard the ER-2 aircraft and its modest size (approximately 100 kg) permits it to be configured for other aircraft. A dual-axes gimbals mechanism provides conical, across-track, and along-track scanning capability. In its present configuration CoSSIR has fifteen channels between 183 GHz and 640 GHz. Three channels are centered about the 183 GHz water vapor absorption line, four channels are centered about the 380 GHz water vapor absorption line, and three dual-polarized channels are centered about the 487 GHz oxygen absorption line. Two channels are located in atmospheric windows at 220 GHz and 640 GHz. All channels are single-linear polarized with the exception of those near 487 GHz. Calibration is achieved by periodically observing two blackbody radiators; one blackbody is heated to approximately 325 K and the other is approximately 250 K during flight. Details of the instrument design as well as measurements from the Cirrus Regional Study of Tropical Anvils and Cirrus Layers - Florida Area Cirrus Experiment will be presented.

Racette, P. E.↗

Geophysical Retrievals and Cloud Analyses from Merged Airborne Radiometer Datasets Covering 10–684 GHz

Airborne microwave radiometers provide insight about numerous aspects of Earth’s atmosphere and yield critical validation datasets for spaceborne radiometers. Three radiometers that are important to NASA’s airborne remote-sensing arsenal include: the Advanced Microwave Precipitation Radiometer (AMPR), covering 10–85 GHz; the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR), covering 50–183 GHz; and the Compact Scanning Submillimeter-wave Imaging Radiometer (CoSSIR), covering 170–684 GHz. The NASA field campaigns of interest to this study include: the Integrated Precipitation and Hydrology Experiment (IPHEx) in 2014, the Olympic Mountains Experiment and Radar Definition Experiment (OLYMPEX/RADEX) in 2015–2016, the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS) in 2020–2023, and the Airborne Lightning Observatory for FEGS and TGFs (ALOFT) in 2023. To provide a more comprehensive perspective on clouds and precipitation observed during these airborne field campaigns, AMPR data were merged spatiotemporally with CoSMIR data for IPHEx, OLYMPEX/RADEX, and IMPACTS (2020 and 2022), while considering differences in instrument characteristics and operations, providing brightness temperature (Tb) values from 10–183 GHz in a common background grid throughout each flight. AMPR and CoSSIR data were similarly merged for IMPACTS (2023) and ALOFT, providing a common background grid with Tb values covering 10–684 GHz throughout each flight. These merged Tb data were employed in geophysical retrievals using the Community Radiative Transfer Model (CRTM), an Eddington radiative transfer model, and a one-dimensional variational (1DVAR) inversion method. Retrievals of cloud liquid water path were of primary interest. This presentation will include an overview of the methods for the radiometer data mergers, the radiative transfer methods, the geophysical retrievals, and detailed results from examining trends in Tb and cloud liquid water path in clouds, precipitation, and cloud-to-precipitation transition zones.

Corey G Amiot↗

Retrieval and Validation of Cirrus Cloud Properties with the Far-Infrared Sensor for Cirrus (FIRSC) During CRYSTAL-FACE

This grant supported the principal investigator's analysis of data obtained during CRYSTAL-FACE by two submillimeter-wave radiometers: the Far-Infrared Sensor for Cirrus (FIRSC) and the Conical Scanning Submillimeter-wave Imaging Radiometer (CoSSIR). The PI led the overall FIRSC investigation, though Co-I Michael Vanek led the instrument component at NASA Langley. The overall CoSSIR investigation was led by James Wang at NASA Goddard, but the cirrus retrieval and validation was performed at the University of Colorado. The goal of this research was to demonstrate the submillimeter-wave cirrus cloud remote sensing technique, provide retrievals of ice water path (IWP) and median mass particle diameter (D(sub me)), and perform validation of the cirrus retrievals using other CRYSTAL-FACE datasets.

Evans, K. Franklin↗

Integrated 222-GHz corner-reflector antennas

A high-gain monolithic millimeter-wave antenna has been designed, fabricated, and tested at 222 GHz. The structure consists of a traveling-wave antenna integrated on a 1.2-micron dielectric membrane and suspended in a longitudinal cavity etched in a silicon wafer. A new traveling-wave antenna design yields a wideband input impedance and a low cross-polarization component in the E- and quasi-H-plane patterns. A directivity of 17.7 dB and a main-beam efficiency of 88.5 percent are calculated from the 222-GHz pattern measurements. The integrated corner-reflector antenna is well suited for millimeter- and submillimeter-wave imaging applications in large f-number systems.

Gearhart, Steven S.↗

A 250 GHz planar low noise Schottky receiver

A planar quasi-optical Schottky receiver based on the quasi-integrated horn antenna has been developed and tested over the 230-280 GHz bandwidth. The receiver consists of a planar GaAs Schottky diode placed at the feed of a dipole-probe suspended on a thin dielectric membrane in an etched-pyramidal horn cavity. The diode has a 1.21 micron anode diameter and a low parasitic capacitance due to the use of an etched surface channel. The antenna-mixer results in a measured DSB conversion loss and noise temperature at 258 GHz of 7.2 dB +/- 0.5 dB and 1310 K +/- 70 K, respectively, at room temperature. The design is compatible with SIS mixers, and the low cost of fabrication and simplicity makes it ideal for submillimeter-wave imaging arrays requiring a 10-20 percent bandwidth.

Ali-Ahmad, Walid Y.↗

Water Vapor Profiling From CoSSIR Radiometric Measurements

Previous millimeter-wave radiometry for water vapor profiling, by either airborne or satellite sensors, has been limited to frequencies less than or equal to 183 GHz. The retrievals are generally limited to an altitude range of 0-10 km. The additional measurements at the frequencies of 380.2 plus or minus 0.8, 380.2 plus or minus 1.8, 380.2 plus or minus 3.3, and 380.2 plus or minus 6.2 GHz provided by the new airborne Compact Scanning Submillimeter-wave Imaging Radiometer (CoSSIR) can extend this profiling capability up to an altitude of about 15 km. Furthermore, the retrievals can be performed over both land and water surfaces in the tropics without much difficulty. These properties are demonstrated by recent CoSSIR measurements on board the NASA WB-57 aircraft during CR-AVE in January 2006. Retrievals of water vapor mixing ratio were performed at eight altitude levels of 1, 3, 5, 7, 9, 11, 13, and 15 km from CoSSIR data sets acquired at observational angles of 0 and 53.4 degrees, and the results were compared with other available measurements from the same aircraft and near-concurrent satellites. A comparison of the variations of mixing ratios retrieved from CoSSIR and those derived from the Meteorological Measurement System (MMS) in the aircraft vicinity, along the path of the transit flight on January 14, 2006, appears to show some connection, although the measurements were referring to different altitudes. A very good agreement was found between the collocated values of total precipitable water derived from the CoSSIR-retrieved water vapor profiles and those estimated from TMI (TRMM Microwave Imager)

Wang, J. R.↗

600-GHz Electronically Tunable Vector Measurement System

A compact, high-dynamic-range, electronically tunable vector measurement system that operates in the frequency range from approximately 560 to approximately 635 GHz has been developed as a prototype of vector measurement systems that would be suitable for use in nearly-real-time active submillimeter-wave imaging. As used here, 'vector measurement system" signifies an instrumentation system that applies a radio-frequency (RF) excitation to an object of interest and measures the resulting amplitude and phase response, relative to either the applied excitatory signal or another reference signal related in a known way to applied excitatory signal.

Dengler, Robert↗

Demonstration of a Submillimeter-Wave HEMT Oscillator Module at 330 GHz

In this work, radial transitions have been successfully mated with a HEMT-based MMIC (high-electron-mobility-transistor-based monolithic microwave integrated circuit) oscillator circuit. The chip has been assembled into a WR2.2 waveguide module for the basic implementation with radial E-plane probe transitions to convert the waveguide mode to the MMIC coplanar waveguide mode. The E-plane transitions have been directly integrated onto the InP substrate to couple the submillimeter-wave energy directly to the waveguides, thus avoiding wire-bonds in the RF path. The oscillator demonstrates a measured 1.7 percent DC-RF efficiency at the module level. The oscillator chip uses 35-nm-gate-length HEMT devices, which enable the high frequency of oscillation, creating the first demonstration of a packaged waveguide oscillator that operates over 300 GHz and is based on InP HEMT technology. The oscillator chip is extremely compact, with dimensions of only 1.085 x 320 sq mm for a total die size of 0.35 sq mm. This fully integrated, waveguide oscillator module, with an output power of 0.27 mW at 330 GHz, can provide low-mass, low DC-power-consumption alternatives to existing local oscillator schemes, which require high DC power consumption and large mass. This oscillator module can be easily integrated with mixers, multipliers, and amplifiers for building high-frequency transmit and receive systems at submillimeter wave frequencies. Because it requires only a DC bias to enable submillimeter wave output power, it is a simple and reliable technique for generating power at these frequencies. Future work will be directed to further improving the applicability of HEMT transistors to submillimeter wave and terahertz applications. Commercial applications include submillimeter-wave imaging systems for hidden weapons detection, airport security, homeland security, and portable low-mass, low-power imaging systems

Radisic, Vesna↗

NASA Tech Briefs, January 2001

The topics include: 1) A "Model" of Interactive Engineering; 2) Feature Section: Communications Technology; 3) lnReview; 4) Application Briefs; 5) Submillimeter-Wave Image Sensor; 6) Ultrasonic/Sonic Drill/Corers With Integrated Sensors; 7) Normally Closed, Piezoelectrically Actuated Microvalve; 8) Magnetostrictively Actuated Valves for Cryosurgical Probes; 9) Remote Sensing of Electric Fields in Clouds; 10) Wireless-Communication Headset Subsystem To Enhance Signaling; 11) Power Amplifier With 9 to 13 dB of Gain From 65 to 146 GHz; 12) Humidity Interlock for Protecting a Cooled Laser Crystal; 13) A Lightweight Ambulatory Physiological Monitoring System; 14) Improvements in a Lightning-Measuring Instrument; 15) Broad-Band, Noninvasive Radio-Frequency Current Probe; 16) Web-Based Technology Distributes Lean Models; 17) Software Guides Aeroelastic-Systems Design; and 18) Postprocessing Software for Micromechanics Analysis Code. A Photonics West 2001 Preview Tech Brief supplement to this January 2001 issue is also included.

Source record↗

Observing Ice Phase Clouds and Precipitation with Millimeter- and Submillimeter-wave Radiometry during the IMPACTS field campaign: Algorithm Development for the Emerging Class of Microwave Radiometers

Millimeter- and submillimeter-wave (mmWave, submm) radiometers provide significant information content on atmospheric water in liquid, ice, and vapor phases. Recent sensors, such as the Global Precipitation Measurement (GPM) or the Temporal Experiment for Storms and Tropical Systems Technology – Demonstration (TEMPEST-D), use mmWave bands to improve estimation of ice-phase precipitation, and future missions, such as the Atmosphere Observing System (AOS), will extend to submm to provide additional information on thinner ice clouds, linking clouds and precipitation and therefore elucidating the links between weather, climate, and the water cycle. To support the expanded use of mmWave/submm radiometry and exploit the available information content on condensed water mass, we demonstrate ice and liquid water path retrievals for NASA Goddard Space Flight Center's airborne radiometers the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) and the Configurable Scanning Submillimeter-wave Instrument/Radiometer (CoSSIR, formerly the Compact Scanning Submillimeter Imaging Radiometer). The analysis is based on data collected during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS) field campaign. A simulation study compares and contrasts retrievals for CoSMIR and CoSSIR, with CoSSIR demonstrating higher skill in ice retrievals, particularly for thin clouds, and the CoSMIR frequencies performing better for liquid. Additionally, we look at dual-polarized radiances observed by CoSMIR during the first two IMPACTS deployments to understand the polarization signatures induced by oriented hydrometeors. Results will be presented in the context of upcoming missions and sensors including AOS and the Ice Cloud Imager (ICI). We will describe the objectives for the expected first flight of the newly upgraded CoSSIR during the final IMPACTS deployment, and we will share novel science investigations we plan to undertake with CoSSIR's new capabilities. Popular Summary: Ice in clouds and falling snow is an important component of weather, climate, and water resources. To better use a new class of sensors that provide information on atmospheric ice, we developed an approach to measure ice clouds and falling snow using airborne data taken during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS), a field campaign to study winter storms. We look at the results for two similar instruments to understand how those differences affect these measurements of clouds and snow, and we further investigate the information the sensors can provide on properties of the clouds and snow.

Ian S Adams↗

Observing Ice Phase Clouds and Precipitation with Millimeter- and Submillimeter-wave Radiometry during the IMPACTS field campaign: Algorithm Development for the Emerging Class of Microwave Radiometers

Millimeter- and submillimeter-wave (mmWave, submm) radiometers provide significant information content on atmospheric water in liquid, ice, and vapor phases. Recent sensors, such as the Global Precipitation Measurement (GPM) or the Temporal Experiment for Storms and Tropical Systems Technology – Demonstration (TEMPEST-D), use mmWave bands to improve estimation of ice-phase precipitation, and future missions, such as the Atmosphere Observing System (AOS), will extend to submm to provide additional information on thinner ice clouds, linking clouds and precipitation and therefore elucidating the links between weather, climate, and the water cycle. To support the expanded use of mmWave/submm radiometry and exploit the available information content on condensed water mass, we demonstrate ice and liquid water path retrievals for NASA Goddard Space Flight Center's airborne radiometers the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) and the Configurable Scanning Submillimeter-wave Instrument/Radiometer (CoSSIR, formerly the Compact Scanning Submillimeter Imaging Radiometer). The analysis is based on data collected during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS) field campaign. A simulation study compares and contrasts retrievals for CoSMIR and CoSSIR, with CoSSIR demonstrating higher skill in ice retrievals, particularly for thin clouds, and the CoSMIR frequencies performing better for liquid. Additionally, we look at dual-polarized radiances observed by CoSMIR during the first two IMPACTS deployments to understand the polarization signatures induced by oriented hydrometeors. Results will be presented in the context of upcoming missions and sensors including AOS and the Ice Cloud Imager (ICI). We will describe the objectives for the expected first flight of the newly upgraded CoSSIR during the final IMPACTS deployment, and we will share novel science investigations we plan to undertake with CoSSIR's new capabilities. Popular Summary: Ice in clouds and falling snow is an important component of weather, climate, and water resources. To better use a new class of sensors that provide information on atmospheric ice, we developed an approach to measure ice clouds and falling snow using airborne data taken during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS), a field campaign to study winter storms. We look at the results for two similar instruments to understand how those differences affect these measurements of clouds and snow, and we further investigate the information the sensors can provide on properties of the clouds and snow.

Ian S Adams↗