Search NASA⌕ Search

SEARCH · Search NASA

Results for “subter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

SubTER ZTEM (Z-Axis Tipper Electromagnetic) Survey Results, Mineral Mountains Area, Utah

This data was acquired as part of the Subsurface Science, Technology and Engineering Research, and Development (SubTER) Crosscut which is a collaboration across the Department of Energy offices involved in research activities in energy production/extraction, subsurface storage, and environmental remediation. The contents of this zip contains the ZTEM survey measured and processed results for the Mineral Mountains area, Utah. The data were acquired through subcontract to Geotech Inc of Aurora, ON, Canada and their narrative report is included. There are also two readme.txt file included that further describe the data.

15 GEOTHERMAL ENERGY↗

Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018

Ground-based transient electromagnetic (TEM) data were acquired in selected locations around Belle Creek, Montana to define the resistivity structure of the near surface. Data were acquired using the ABEM WalkTEM system (Guideline Geo Ab, Sundbyberg, Sweden). TEM data were processed and numerically inverted to derive one-dimensional resistivity structure using SPIA (Aarhus Geosoftware, Aarhus, Denmark). This release includes raw and processed TEM data and resistivity models for each data location using the following structure: Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018.xml SBC_TEM_2019_SoundingLocationsModels.gdb.zip - file geodatabase with all models and plots attached. This is a mirror of the contents of the model directory. Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018.zip Data SBC_USF - raw data USF_format_description.pdf - manual describing the USF file format SBC_SoundingID-USF_lookup.csv - table describing the USF file naming convention and channel mapping *.usf files - raw, unprocessed data files SBC_TEM - processed data AarhusInv_manual.pdf - manual describing the TEM file format *.tem files - processed data files Models SBC_Model_Plots - plots of the data and the models for each sounding location TEM_model_data_dictionary.csv - data dictionary describing tabulated models SBC_TEM_models.csv - tabulated models

geophysical surveying↗

Geothermal Fault Zone and Fluid Imaging through Joint Airborne ZTEM and Ground MT Data Inversion Analysis

This project has aimed to achieve detailed electrical resistivity resolution at geothermal reservoir scales by combining airborne natural electromagnetic (EM) field surveying (ZTEM) with ground magnetotelluric (MT) measurements to approximate an airborne MT geophysical method. MT alone is relatively expensive and may have permitting challenges in sensitive areas. Airborne ZTEM field data contains only the magnetic field, requires a background assumption, and has been limited to relatively high frequencies, thus suffering uniqueness problems. Based on proto-type 2D simulations, ZTEM ambiguities may be reduced through formal incorporation with possibly sparse ground MT soundings, which we pursued in full 3D for this project. The methodology was tested at the high-temperature Roosevelt Hot Springs geothermal system, Utah, which was considered advantageous given the near total exposure of crystalline reservoir rocks across the project area. ZTEM and ground MT survey data were acquired in 2017, subcontracted to outside parties with which we have worked in the past. These included 80 remote-referenced tensor MT soundings over the Mineral Mountains and adjacent Roosevelt Hot Spring producing geothermal system. These MT stations abut later coverage of a similar number of MT stations taken for the Utah FORGE project providing excellent total data aperture to re-solve structure beneath both project areas better than either set alone. The airborne ZTEM survey covered 704 line kilometers in E-W flight lines with a 250 m line spacing. Although this survey was timed during a maintenance-related shutdown of power production at the Roosevelt Hot Springs, other noise sources difficult to identify but including two high-voltage state-scale transmission lines compromised the ZTEM survey badly leading to unusable responses. Thus, with DOE management concurrence, the project proceeded to emphasize inversion and interpretation of the joint SubTER-FORGE MT data sets with regard to the Roosevelt Hot Springs reservoir recharge and to deep heat sources for both it and the Utah FORGE EGS project area. We also investigated the joint ZTEM-MT sampling concept with data sets from the Eleven Mile Canyon prospect area donated by the U.S. Navy (A. Sabin, PoC). Inversion of the SubTER-FORGE MT data using the HexMT 3D finite element algorithm reveals a large, low-resistivity anomaly extending sub-vertically through the depth range of the crust beneath the western Mineral Mountains. The steep conductive zone connects in the lower crust to a more tabular conductor characteristic of much of the Great Basin that generally is ascribed to current mafic magmatic underplating, hybridization and fluid release. The location of the resolved anomaly relative to the recent (0.5-0.8 Ma) eruptive centers of the Mineral Mountains implicates it as remnants of the magma body which fed these centers. This structure appears to be currently feeding heat and fluids upward into the Roosevelt Hot Springs hydrothermal system, as well as heat laterally to the FORGE project area. Separate and joint inversion models were carried out for the donated Eleven Mile Canyon MT-ZTEM data set to demonstrate concept. ZTEM only inversion showed two main alteration zones in the western portion of the project area known from geological mapping. Joint inversion including an E-W profile of MT soundings sharpened these features considerably. It also resolved in much greater detail the graben related normal faulting structure of the central project area which lies at depths exceeding the sensitivity of ZTEM alone. The sparse number of MT da-ta relative to the ZTEM required upweighting the former by a factor of several, but an exact procedure awaits future research. Our final impression is that sparse MT data can improve resolution of the subsurface over that of ZTEM alone. However, well sampled MT data are to be preferred and offer the simplicity of interpreting just one data type, and possess the superior resolution capability coming with the electric field everywhere, and from their high bandwidth.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Southwestern Utah Magnetotelluric (MT) Data

This comprehensive magnetotellurics (MT) dataset, which covers southwestern Utah, integrates 600 sites from various surveys, including those from the Utah FORGE, SubTER, and Play Fairway projects, all of which are linked below. The core of this dataset is the use of a 3D finite element (FE) algorithm for inversion imaging, allowing for detailed analysis of the MT data. Provided here are all .edi files, the 3D finite element mesh (with a readme file), graphic slices, node graphics, resistivity graphics, and reports on the acquisition areas and inversion.

15 GEOTHERMAL ENERGY↗

Hydraulic fracturing experiments at 1500 m depth in a deep mine: Highlights from the kISMET project

In support of the U.S. DOE SubTER Crosscut initiative, we established a field test facility in a deep mine and designed and carried out in situ hydraulic fracturing experiments relevant to enhanced geothermal systems (EGS) in crystalline rock to characterize the stress field, understand the effects of rock fabric on fracturing, and gain experience in monitoring using geophysical methods. The project also included pre- and post-fracturing simulation and analysis, and laboratory measurements and experiments. The kISMET (permeability (k) and Induced Seismicity Management for Energy Technologies) site was established in the West Access Drift of the Sanford Underground Research Facility (SURF) 4757 ft (1450 m) below ground (on the 4850 ft level (4850L)) in phyllite of the Precambrian Poorman Formation. We drilled and continuously cored five near-vertical boreholes in a line on 3 m (10 ft) spacing, deviating the two outermost boreholes slightly to create a five-spot pattern around the test borehole centered in the test volume 40 m below the drift invert (floor) at a total depth of ~1490 m (4890 ft). Laboratory measurements of core from the center test borehole showed P-wave velocity heterogeneity along each core indicating strong, fine-scale (~1 cm or smaller) changes in the mechanical properties of the rock. Field measurements of the stress field by hydraulic fracturing showed that the minimum horizontal stress at the kISMET site averages 21.7 MPa (3146 psi) trending approximately N-S (356 degrees azimuth) and plunging slightly NNW at 12°. The vertical and horizontal maximum stresses are similar in magnitude at 42-44 MPa (6090-6380 psi) for the depths of testing, which averaged approximately 1530 m (5030 ft). Hydraulic fractures were remarkably uniform suggesting core-scale and larger rock fabric did not play a role in controlling fracture orientation. Analytical solutions suggest that the fracture radius of the large fracture (stimulation test) was more than 6 m (20 ft), depending on the unknown amount of leak-off.

Oldenburg, C↗

Seismic Survey 2016 Data at Crescent Valley, Nevada

In September 2016, 989 vertical-component seismic instruments were deployed for 75 hours at the Crescent Valley greenfield geothermal play area in Nevada. Data were recorded 12/9/16 - 12/15/16. Data are stored in individual files in one-minute increments in SEGD formats. See the metadata in Crescent Valley Station Locations.sp1, Crescent Valley Observer Logs.xls, and the attached Metadata link for details about the seismic station locations, seismic data logger specifications, instrumentation specifications, descriptions of data, a fracture finding summary, and the final report for the 2016 seismic survey done in Crescent Valley, Nevada. Note that no discrete events were identified, and a 1750m x 2250m x 300m PSET volume of acoustic energy was delivered.

15 GEOTHERMAL ENERGY↗