Search NASA⌕ Search

SEARCH · Search NASA

Results for “suction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Single-stage evaluation of highly-loaded high-Mach-number compressor stages 5. Data and performance of baseline, corner-blow wall suction and combined corner blow wall suction stator

A single-stage compressor with a rotor tip speed of 1600 ft/sec and a 0.5 hub tip ratio was used to investigate the effects of several stator endwall treatment methods on stage range and performance. These endwall treatment methods consisted of stator corner-blow, annular wall suction upstream of stator leading edge, and combined corner-blow and annular wall suction. The overall stage performance with corner blow was essentially the same as the baseline performance. The performance for the annular wall suction and the combined corner-blow and wall suction showed a reduction in peak efficiency of 2.5 percentage points compared to the baseline data.

Nikkanen, J. P.↗

Experimental study of flow due to an isolated suction hole and a partially plugged suction slot

Details for construction of a model of a partially plugged, laminar flow control, suction slot and an isolated hole are presented. The experimental wind tunnel facility and instrumentation is described. Preliminary boundary layer velocity profiles (without suction model) are presented and shown to be in good agreement with the Blasius laminar profile. Recommendations for the completion of the study are made. An experimental program for study of transition on a rotating disk is described along with preliminary disturbance amplification rate data.

Goglia, G. L.↗

Instabilities orginating from suction holes used for Laminar Flow Control (LFC)

A small-scale wind tunnel previously used for turbulent boundary layer studies has been modified for experiments in laminar flow control. The facility incorporates suction through interchangeable porous test surfaces which are used to stabilize the boundary layer and delay transition to turbulent flow. The thin porous test surfaces are supported by a baffled plenum chamber box which also acts to gather the flow through the surface into tubes which are routed to a high pressure fan. An elliptic leading edge is attached to the assembly to establish a new layer on the test plate. A slot is used to remove the test section flow below the leading edge. The test section was lengthened and fitted with a new ceiling. Substantial modifications were also made to the 3D probe traverse. Detailed studies have been made using isolated holes to explore the underlying instability mechanisms. The suction is perturbed harmonically and data are averaged on the basis of the phase of the disturbance. Conditions corresponding to strong suction and without suction have been studied. In both cases, 3D contour surfaces in the vicinity of the hole show highly three-dimensional T-S waves that fan out away from the hole with streamwise distance. With suction, the perturbations on the centerline are much stronger and decay less rapidly, while the far field is similar to the case without suction. Downstream the contour surfaces of the bow-shaped TS waves develop spanwise irregularities which eventually form into clumps. The contours remain smooth when suction is not applied. Even without suction, the harmonic point source is challenging for CFD; e.g. DNS has been used for streamwise growth. With suction, grid resources are consumed by the hole and this makes DNS even more expensive. Limited DNS results so far indicate that the vortices which emanate from suction holes appear to be stable. The spanwise clumping observed in the experiment is evidence of a secondary instability that could be associated with suction vortices. A typical porous surface for LFC consists of 0.002 inch diameter holes with 0.020 inch grid spacing L, which is too small to resolve disturbances. A 20:1 scale porous test surface has been machined for improved spatial resolution while the L/d is still representative of flight conditions. Designers of porous surfaces use Goldsmith's criterion to minimize crossstream interaction. However nothing is known about the streamwise interactions. Results using two holes, aligned but displaced in the streamwise direction, indicate that partial TS wave cancellation is possible, depending on the hole spacing and disturbance frequency. Using DNS for streamwise interaction studies will be prohibitively expensive if linear superposition cannot be used for the multiple holes.

Watmuff, Jonathan H.↗

Reduction of acoustic disturbances in the test section of supersonic wind tunnels by laminarizing their nozzle and test section wall boundary layers by means of suction

The feasibility of quiet, suction laminarized, high Reynolds number (Re) supersonic wind tunnel nozzles was studied. According to nozzle wall boundary layer development and stability studies, relatively weak area suction can prevent amplified nozzle wall TS (Tollmien-Schlichting) boundary layer oscillations. Stronger suction is needed in and shortly upstream of the supersonic concave curvature nozzle area to avoid transition due to amplified TG (Taylor-Goertler) vortices. To control TG instability, moderately rapid and slow expansion nozzles require smaller total suction rates than rapid expansion nozzles, at the cost of larger nozzle length Re and increased TS disturbances. Test section mean flow irregularities can be minimized with suction through longitudinal or highly swept slots (swept behind local Mach cone) as well as finely perforated surfaces. Longitudinal slot suction is optimized when the suction-induced crossflow velocity increases linearly with surface distance from the slot attachment line toward the slot (through suitable slot geometry). Suction in supersonic blowdown tunnels may be operated by one or several individual vacuum spheres.

Pfenninger, W.↗

An Approximate Method for Calculation of the Laminar Boundary Layer with Suction for Bodies of Arbitrary Shape

Various ways were tried recently to decrease the friction drag of a body in a flow; they all employ influencing the boundary layer. One of them consists in keeping the boundary layer Laminar by suction; promising tests have been carried out. Since for large Reynolds numbers the friction drag of the laminar boundary layer is much lower than that of the turbulent boundary layer, a considerable saving in drag results from keeping the boundary layer laminar, even with the blower power required for suction taken into account. The boundary layer is kept laminar by suction in two ways: first, by reduction of the thickness of the boundary layer and second, by the fact that the suction changes the form of the velocity distribution so that it becomes more stable, in a manner similar to the change by a pressure drop. There by the critical Reynolds number of the boundary layer (USigma*/V) (sub crit) becomes considerably higher than for the case without suction. This latter circumstance takes full effect only if continuous suction is applied which one might visualize realized through a porous wall. Thus the suction quantities required for keeping the boundary layer laminar become so small that the suction must be regarded as a very promising auxiliary means for drag reduction.

Schlichting, H.↗

Performance of a short annular dump diffuser using suction-stabilized vortices at inlet Mach numbers to 0.41

A short, annular dump diffuser was designed to use suction to establish stabilized vortices on both walls for improved flow expansion in the region of an abrupt area change. The diffuser was tested at near ambient inlet pressure and temperature. The overall diffuser area ratio was 4.0. The inlet height was 2.54 cm and the exit pitot-static rakes were located at a distance from the vortex fence equal to two or six times the inlet height. Performance data were taken at near ambient temperature and pressure for nominal inlet Mach numbers of 0.18 to 0.41 with suction rates of 0 to 18 percent of the total inlet airflow. The exit velocity profile could be shifted toward either wall by adjusting the inner- or outer-wall suction rate. Symmetrical exit velocity profiles were unstable, with a tendency to shift back to hub- or tip-weighted profile. Diffuser effectiveness was increased from about 47 percent without suction to over 85 percent at a total suction rate of about 14 percent. The diffuser total pressure losses at inlet Mach numbers of 0.18 and 0.41 decreased from 1.1 and 5.6 percent without suction to 0.48 and 5.2 percent at total suction rates of 14.4 and 5.6 percent, respectively.

Smith, J. M.↗

Recent sidewall boundary-layer investigations with suction in the Langley 0.3-m Transonic Cryogenic Tunnel

An experimental and theoretical study of the Langley 0.3-m Transonic Cryogenic Tunnel (TCT) sidewall boundary-layer with and without suction, has been made. Without suction, the boundary-layer displacement thickness at a station ahead of the model varied from about 1.6 mm to 1.3 mm over a Reynolds number range of 20 million to 200 million per m at Mach numbers from 0.30 to 0.76. Measured velocity profiles were correlated using the defect law of Hama. The boundary-layer displacement thickness decreased when suction was applied; however, after suction of about 2 percent of test section mass flow, the change in the thickness was small. A comparison of the measured suction effectiveness with finite difference and integral methods of boundary-layer calculation showed that both methods predicted the right trend over the range of suction velocities (up to a suction to free-stream velocity ratio of -0.02).

Murthy, A. V.↗

Effect of wall suction on the stability of compressible subsonic flows over smooth two-dimensional backward-facing steps

The effect of suction on the stability of compressible flows over backward-facing steps is investigated. Mach numbers up to 0.8 are considered. The results show that continuous suction stabilizes the flow outside the separation bubble, but it destabilizes the flow inside it. Nevertheless, the overall N factor decreases as the suction level increases due to the considerable reduction of the separation bubble. For the same suction flow rate, properly distributed suction strips stabilize the flow more than continuous suction. The size of the separation bubble, and hence its effect on the instability can be considerably reduced by placing strips with high suction velocities in the separation region.

Al-Maaitah, Ayman A.↗

Supersonic boundary layer stability analysis with and without suction on aircraft wings

An analysis of the boundary layer and its stability with and without suction on a supersonic cruise fighter wing having biconvex 5 percent thick airfoils is conducted for a free-stream Mach number of 2.0 and an angle of attack of 4.0 deg. It is found that the largest amplification is due to the highly oblique traveling cross flow type waves, oriented approximately 80 deg without suction, and 87.5 deg with suction, from the local external velocity vector. It is concluded that with the biconvex airfoil section on the thin swept wing, this type of instability would be the likely cause of transition. The approximate values of the frequency, wave orientation angle, and wavelength/chord ratio for the most amplified disturbance are given for the cases of suction and no suction. The largest amplifications are found for highly oblique traveling crossflow type waves oriented at approximately 80 deg without suction and 87.5 deg with suction, measured from the local external velocity vector.

Agrawal, Shreekant↗

Design and experimental performance of short curved wall diffusers with axial symmetry utilizing slot suction

The feasibility of designing short curved wall axially symmetrical subsonic diffusers utilizing suction through slots in the diffuser walls to prevent flow separation was investigated. A potential flow analysis was made, and a digital computer program was written for determining the diffuser wall contour for prescribed boundary conditions. The flow field included branch flow so that the suction slot geometry could be a part of the diffuser design. One bell shaped diffuser and three annular diffusers with area ratios of either 2.5:1 or 3:1 were designed, fabricated, and tested. Minimum suction requirements of metastable operation ranged from 6.3 percent to 12 percent when operating with inlet air velocities in the 1000 to 250 ft/sec (30 to 76 m/sec) range. For stable operation suction rates from 10 percent to 22 percent were required. In all cases the diffuser effectiveness was above 95 percent based on the conventional definition, and from 81 percent to 94 percent when the suction loss was accounted for. The exit velocity profiles were virtually flat with no more than + or - 9% variation over 95 percent of the exit area when operated with sufficient suction to prevent flow separation.

Yang, T.↗

Performance of a short annular dump diffuser using wall trailing-edge suction

A short annular dump (abrupt flow area change) diffuser was tested with suction through wall trailing-edge slots at inlet Mach numbers of 0.19 and 0.27 and at near ambient inlet temperature and pressure, with suction flow varied from zero to 10 percent of the inlet air mass-flow rate. The overall ratio of diffuser exit area to inlet area was 4.0, and the ratio of length to inlet height was 2.0. By applying suction flow separately on either wall or to both walls simultaneously, the original annular jet profile could be altered to either a hub- or tip-biased profile. Diffuser effectiveness was increased from about 25 percent with no suction to 50 percent at 6 percent outer-wall suction and to 52 percent at a combined suction rate on both walls of 10.25 percent. At the same time, diffuser total pressure loss was reduced by one-fourth.

Juhasz, A. J.↗

Method for maintaining precise suction strip porosities

This invention relates to a masking method generally and, more particularly to a method of masking perforated titanium sheets having laminar control suction strips. As illustrated in the drawings, a nonaerodynamic surface of a perforated sheet has alternating suction strip areas and bonding land areas. Suction strip tapes overlie the bonding land areas during application of a masking material to an upper surface of the suction strip tapes. Prior to bonding the perforated sheet to a composite structure, the bonding land tapes are removed. The entire opposite aerodynamic surface is masked with tape before bonding. This invention provides a precise control of suction strip porosities by ensuring that no chemicals penetrate the suction strip areas during bonding.

Gallimore, Frank H.↗

Navier-Stokes simulations of the effects of suction holes on a flat plate boundary layer

Direct numerical simulations (DNS) of the Navier-Stokes equations are employed to explore the effects of suction holes on transition in a laminar flat plate boundary layer. The Navier-Stokes equations are cast in vorticity-velocity form. Periodicity is imposed in spanwise direction; all other spatial derivatives are discretized with fourth order compact differences. An explicit fourth order Runge-Kutta scheme is employed for the time-integration of the vorticity transport equations. Suction is applied through a row of holes aligned in spanwise direction. For low suction strengths, each hole generates a pair of stable streamwise vortices. When the suction strength exceeds a critical value, the vortices become unstable. For high suction strengths, vortex shedding occurs right at the suction holes. Our numerical findings agree well with experimental observations.

Meitz, Hubert L.↗

Optimum Suction Distribution for Transition Control

The optimum suction distribution which gives the longest laminar region for a given total suction is computed. The goal here is to provide the designer with a method to find the best suction distribution subject to some overall constraint applied to the suction. We formulate the problem using the Lagrangian multiplier method with constraints. The resulting non-linear system of equations is solved using the Newton-Raphson technique. The computations are performed for a Blasius boundary layer on a flat-plate and crossflow cases. For the Blasius boundary layer, the optimum suction distribution peaks upstream of the maximum growth rate region and remains flat in the middle before it decreases to zero at the end of the transition point. For the stationary and travelling crossflow instability, the optimum suction peaks upstream of the maximum growth rate region and decreases gradually to zero.

Balakumar, P.↗

Control of Supersonic Boundary Layers Using Steady Suction

Control of supersonic boundary layers using steady suction through a series of very small two-dimensional strips is numerically investigated at a free stream Mach number of 1.8. The mean flow induced by rows of suction holes is also computed. Both the steady and unsteady solutions are obtained by solving the full Navier-Stokes equations using the 5th-order accurate weighted essentially non-oscillatory (WENO) scheme for space discretization and using third-order total-variationdiminishing (TVD) Runge-Kutta scheme for time integration. Computations for the two-dimensional cases are performed at suction coefficients 0.001 and 0.002 to investigate the stabilizing effects of suction. The simulation showed that a series of shock waves are generated at the slots. The stability results showed that the total amplification is reduced up to the end of the computational domain. However, the growth rates become larger at downstream distances away from the suction region. The computations for the suction holes showed the generation of Mach waves from each hole and the formation of longitudinal vortices.

Balakumar, P.↗

Heat-transfer and pressure distributions for laminar separated flows downstream of rearward-facing steps with and without mass suction

Heat-transfer and pressure distributions were measured for laminar separated flows downstream of rearward-facing steps with and without mass suction. The flow conditions were such that the boundary-layer thickness was comparable to or larger than the step height. For both suction and no-suction cases, an increase in the step height resulted in a sharp decrease in the initial heat-transfer rates behind the step. Downstream, however, the heat transfer gradually recovered back to less than or near attached-flow values. Mass suction from the step base area increased the local heat-transfer rates; however, this effect was relatively weak for the laminar flows considered. Even removal of the entire approaching boundary layer raised the post-step heat-transfer rates only about 10 percent above the flatplate values. Post-step pressure distributions were found to depend on the entrainment conditions at separation. In the case of the solid-faced step, a sharp pressure drop behind the step was followed by a very short plateau and relatively fast recompression. For the slotted-step connected to a large plenum but without suction, the pressure drop at the base was much smaller and the downstream recompression more gradual than that for solid-faced step.

Brown, R. D.↗