At least 19 records

Colorado Potential Geothermal Pathways

This layer contains the weakened basement rocks. Isostatic gravity was utilized to identify structural basin areas, characterized by gravity low values reflecting weakened basement rocks. Together interpreted regional fault zones and basin outlines define geothermal "exploration fairways", where the potential exists for deep, superheated fluid flow in the absence of Pliocene or younger volcanic units.

15 GEOTHERMAL ENERGY↗

Working fluid selection for organic Rankine cycle power generation using hot produced supercritical CO 2 from a geothermal reservoir

Geothermal heat mining simulations using supercritical CO 2 (sCO 2 ) were performed in this research. Working fluid selection criteria for power generation using sCO 2 from a geothermal reservoir are then presented for subcritical, superheated and supercritical organic Rankine cycles (ORCs). Meanwhile, method of working fluid classification for ORC is proposed. To get the most feasible ORC design, this study introduces the concept of “turning point” for isentropic and dry working fluids, as well as minimum turbine inlet temperature for wet working fluids. A thermodynamic model was developed with capabilities to obtain the optimal working fluid mass flow rate, evaporation temperature, superheated temperature, and supercritical pressure, to evaluate the thermal performance of the three ORC approaches using hot produced sCO 2 . With this model, thirty potential working fluids with critical temperatures in the range from 50 to 225 °C were screened for utilizing hot produced sCO 2 considering physical properties, environmental and safety impacts, and thermodynamic performances. Finally, the thermodynamic results were compared for all possible working fluids.

15 GEOTHERMAL ENERGY↗

Numerical Simulation of V-shaped Segregation in Continuous Casting Blooms Based on a Microsegregation Model

This study establishes a volume-averaged model for transport phenomena to study V-shaped segregation in continuous casting blooms with different superheating and cooling rates by coupling fluid flow, macro-scale heat transfer, and solute transport. The results demonstrate that the modified Won–Thomas model considering back diffusion in the solid phase corresponds well with the measured carbon segregation. V-shaped segregation decreases with decreasing superheating and increases slightly with decreases in the cooling rate. The results of original position statistical distribution analysis correspond well with the simulation results. This phenomenon can be exploited to improve the quality of bloom.

42 ENGINEERING↗

Analysis of nanoscale two-phase flow of argon using molecular dynamics

Two phase flows through micro and nanochannels have attracted a lot of attention because of their immense applicability to many advanced fields such as MEMS/NEMS, electronic cooling, bioengineering etc. In this work, a molecular dynamics simulation method is employed to study the condensation process of superheated argon vapor force driven flow through a nanochannel combining fluid flow and heat transfer. A simple and effective particle insertion method is proposed to model phase change of argon based on non-periodic boundary conditions in the simulation domain. Starting from a crystalline solid wall of channel, the condensation process evolves from a transient unsteady state where we study the influence of different wall temperatures and fluid wall interactions on interfacial and heat transport properties of two phase flows. Subsequently, we analyzed transient temperature, density and velocity fields across the channel and their dependency on varying wall temperature and fluid wall interaction, after a dynamic equilibrium is achieved in phase transition. Quasi-steady nonequilibrium temperature profile, heat flux and interfacial thermal resistance were analyzed. The results demonstrate that the molecular dynamics method, with the proposed particle insertion method, effectively solves unsteady nonequilibrium two phase flows at nanoscale resolutions whose interphase between liquid and vapor phase is typically of the order of a few molecular diameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Power Generation Cycle with RELAP-7

Balance of plant of a High-Temperature gas-cooled Reactor – Pebble bed Module (HTR-PM) is modeled using RELAP-7. The model includes the primary helium loop where the heat produced by the core is transferred to a helical-coil steam generator and the secondary loop where super-heated steam is fed to a turbine to extract power. The steam is then condensed to subcooled water and pumped back into the steam generator. Results demonstrate that RELAP-7 has the capability to model different regimes encountered in two-phase flow with wall boiling, superheated steam, subcooled liquid and condensation. RELAP-7 also has the capability of modeling different fluids with their own specific models in a very flexible way, without any code change. This also demonstrates the capability of modeling the transfer of fission power into electrical power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a mechanistic model for sliding bubbles growth prediction in subcooled boiling flow

In this paper, a new mechanistic model for predicting the growth of sliding bubbles in subcooled boiling flow has been developed. The basis of this model is the assumption that the fundamental heat transfer mechanisms acting on a stagnant bubble growing at a nucleation site can also be applied to the growth of sliding bubbles. The physical assumptions of the existing bubble growth models were modified to reflect the intrinsic physics associated with the sliding bubble growth. The heat transfer mechanisms considered are microlayer evaporation, evaporation of superheated liquid, and condensation. The present model has been successfully validated against a broad set of subcooled flow boiling data, generated by three separate research groups using different working fluids and different heater surfaces. The model successfully reproduced the sliding bubble growth dependencies on mass flux, wall superheat, and liquid subcooling level as observed in the experiments. Finally, on the other hand, in a few cases where the bubble growth inertia was substantially involved in the sliding bubble growth, the predictive ability was limited.

42 ENGINEERING↗

Multidimensional mechanistic modeling of interfacial heat and mass transfer

A combined theoretical and computational study in modeling multidimensional, diabatic vapor/liquid flows is presented. Models have been developed governing kinematic aspects of multiphase flow as well as interfacial mass and heat transfer for flows of condensable gas (vapor) and liquids. The modeling formulation is based on the Reynolds averaged Navier-Stokes (RANS) type multi-field approach which utilizes a complete set of conservation equations for each fluid component 1. The modeled interfacial interactions include energy, mass, and momentum transfer. Emphasis in the model development work has been placed on the mechanisms governing coupled interfacial heat and mass transfer between the liquid and vapor fields (condensation and/or boiling). A method for tracking changes in bubble size is presented and tested. Locally based models of multidimensional effects have been analyzed, including distributions of fluid temperatures and volume fractions. The overall model accounts for both kinematic and thermodynamic nonequilibrium between the component fluids including superheated vapor. The model has been implemented in the NPHASE-CMFD computer code. Results from the kinematic model are compared to experimental data and good agreement is demonstrated. The heat and mass transfer model is parametrically tested to show the multidimensional effects on the rate of heat and mass transfer. These effects are explained in terms of local characteristics of the two-phase flow. The model is applied to a scenario of saturated vapor injected into a subcooled flow through a heated, porous wall. This provides a reasonable approximation to subcooled boiling. The results are found to be dependent on the partitioning of the wall heat flux between direct liquid heating and vapor generation. However, the observed dependencies are explained and the modeling is considered consistent. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Pressure Drop-Flow Rate Curves for Single Phase Steam in Steam Generator U-tubes During Severe Accidents

Thermally induced steam generator tube rupture (TI-SGTR) can occur in pressurized water reactors (PWRs) with U-tube steam generators (SGs) during high pressure severe accident sequences resulting in containment bypass. Robust natural circulation patterns including in-vessel natural circulation and countercurrent flow to and from the SGs of superheated steam and other hot gases heats cooler structures in the reactor coolant system (RCS). The buoyancy driven flows return cooler and denser gases back to the core slowing the progression of some core degradation phenomena and failure of the lower head. As much as 50 percent of the decay energy and energy produced from core degradation oxidation reactions can be transported from the core to SGs resulting in the heat up and thermal creep of RCS pressure boundary components including hot leg nozzles, pressurizer surge line, and the SG tubes, many of which contain flaws. The creep failure of an individual tube is dependent on the transitory heating of the tube, a function of the mass flow rate through the tube and local temperature history of steam entering the tube. Buoyancy driven natural circulation flow rates are determined by changes in gravitational head, a combination of changes in fluid density due to heat transfer and change in elevation, and irreversible pressure drops resulting primarily from friction loss in the flow paths and other form losses. The nonuniform flow distribution in U-tubes of varying lengths and heights during single-phase liquid and two-phase natural circulation has been extensively studied in scaled test facilities and verified numerically in previous works. We hypothesize the countercurrent natural circulation of single-phase superheated steam in U-tube SGs is governed by the same characteristic pressure drop-flow rates curves of single-phase liquid and two-phase natural circulations in U-tubes connected to common plena derived in. Secondly, we propose flow distribution is a function of U-tube geometry - height, length, hydraulic diameter, etc., and the larger SGs of Combustion Engineering (CE) style 2 x 4 PWRs, which are the focus of this study, will show greater nonuniformity in tube by tube flow rates and ratio of forward flowing tubes to reverse flowing tubes. This work derives characteristic pressure drop-flow rate curves for single-phase superheated steam in CE-type SGs during a high pressure station blackout (SBO) sequence with failed auxiliary feedwater (AFW) and dry secondary side which is closely related to the TI-SGTR event. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a Mechanistic Model for Predicting Sliding Vapor Bubble Growth

A new mechanistic model for predicting the growth of sliding vapor bubble in subcooled boiling flows has been developed. This model employs a physical base that the fundamental mechanisms applied to the bubble growth at a nucleation site can also be applied to the growth of sliding bubble. The heat transfer mechanisms considered are microlayer evaporation, evaporation of superheated liquid, and condensation. Modifications were made to the physical assumptions/reasoning applied to the existing growth models to reflect the intrinsic physics associated with the growth of sliding bubble. The present model has been successfully validated against a broad set of subcooled flow boiling data generated by three separate research groups using different working fluids and heater surfaces. The physical dependency of bubble growth during sliding on the relevant flow boiling parameters (i.e., mass flux, wall superheat, and subcooling level) observed in these experiments was well reproduced by the present model.

42 ENGINEERING↗

Hydrodynamic behavior of wrapped coil water heater tank

In this work, a numerical investigation using computational fluid dynamics (CFD) has been carried out to analyze the thermal behavior of a water tank integrated to a heat pump water heating system (HPWH). The heat pump condenser is a long coil wrapped around the water tank and insulated from outside from which heat is transferred from the heat pump cycle into the water stored inside the tank. The simulated water tank has a capacity of about 170 L with the charging inlet located at the bottom segment of the tank and the discharging outlet located at the top segment of the tank like commercially available water heaters. The tank was simulated during charging/discharging process with isothermal boundary condition at the tank wall to represent the majority of the process for refrigerant condensation inside the heat pump condenser (excluding superheated and sub-cooled section). Three flow rates were selected to represent low, medium and high flow pattern. Both mean and turbulent flow properties were calculated and analyzed. Heat transfer mechanisms inside the tank are quantified by calculating Richardson and Péclet numbers to show the relative contribution of driving forces. The calculations show that advection is dominant over diffusion. Mixing factor is calculated and presented. It is found that the rate of increase of mixing is nonlinear with the increase in flow rate. Mixing increased by a factor of four when the flow rate increased by a factor of two.

stratification↗

Partial Oxidation Gas Turbine for Power and Hydrogen Co-Production from Coal-Derived Fuel in Industrial Applications

The report presents a feasibility study of a new type of gas turbine. A partial oxidation gas turbine (POGT) shows potential for really high efficiency power generation and ultra low emissions. There are two main features that distinguish a POGT from a conventional gas turbine. These are associated with the design arrangement and the thermodynamic processes used in operation. A primary design difference of the POGT is utilization of a non?catalytic partial oxidation reactor (POR) in place of a conventional combustor. Another important distinction is that a much smaller compressor is required, one that typically supplies less than half of the air flow required in a conventional gas turbine. From an operational and thermodynamic point of view a key distinguishing feature is that the working fluid, fuel gas provided by the OR, has a much higher specific heat than lean combustion products and more energy per unit mass of fluid can be extracted by the POGT expander than in the conventional systems. The POGT exhaust stream contains unreacted fuel that can be combusted in different bottoming ycle or used as syngas for hydrogen or other chemicals production. POGT studies include feasibility design for conversion a conventional turbine to POGT duty, and system analyses of POGT based units for production of power solely, and combined production of power and yngas/hydrogen for different applications. Retrofit design study was completed for three engines, SGT 800, SGT 400, and SGT 100, and includes: replacing the combustor with the POR, compressor downsizing for about 50% design flow rate, generator replacement with 60 90% ower output increase, and overall unit integration, and extensive testing. POGT performances for four turbines with power output up to 350 MW in POGT mode were calculated. With a POGT as the topping cycle for power generation systems, the power output from the POGT ould be increased up to 90% compared to conventional engine keeping hot section temperatures, pressures, and volumetric flows practically identical. In POGT mode, the turbine specific power (turbine net power per lb mass flow from expander exhaust) is twice the value of the onventional turbine. POGT based IGCC plant conceptual design was developed and major components have been identified. Fuel flexible fluid bed gasifier, and novel POGT unit are the key components of the 100 MW IGCC plant for co producing electricity, hydrogen and/or yngas. Plant performances were calculated for bituminous coal and oxygen blown versions. Various POGT based, natural gas fueled systems for production of electricity only, coproduction of electricity and hydrogen, and co production of electricity and syngas for gas to liquid and hemical processes were developed and evaluated. Performance calculations for several versions of these systems were conducted. 64.6 % LHV efficiency for fuel to electricity in combined cycle was achieved. Such a high efficiency arise from using of syngas from POGT exhaust s a fuel that can provide required temperature level for superheated steam generation in HRSG, as well as combustion air preheating. Studies of POGT materials and combustion instabilities in POR were conducted and results reported. Preliminary market assessment was performed, and recommendations for POGT systems applications in oil industry were defined. POGT technology is ready to proceed to the engineering prototype stage, which is recommended.

01 COAL, LIGNITE, AND PEAT↗

Modeling of internal and near-nozzle flow for a GDI fuel injector

A numerical study of two-phase flow inside the nozzle holes and the issuing spray jets for a multi-hole direct injection gasoline injector has been presented in this work. The injector geometry is representative of the Spray G nozzle, an eight-hole counterbore injector, from the Engine Combustion Network (ECN). Simulations have been carried out for a fixed needle lift. Effects of turbulence, compressibility and non-condensable gases have been considered in this work. Standard k -ε turbulence model has been used to model the turbulence. Homogeneous Relaxation Model (HRM) coupled with Volume of Fluid (VOF) approach has been utilized to capture the phase change phenomena inside and outside the injector nozzle. Three different boundary conditions for the outlet domain have been imposed to examine non-flashing and evaporative, non-flashing and non-evaporative and flashing conditions. Noticeable hole-to-hole variations have been observed in terms of mass flow rates for all the holes under all the operating conditions considered in this study. Inside the nozzle holes mild cavitation-like and in the near-nozzle region flash boiling phenomena have been predicted when liquid fuel is subjected to superheated ambiance. Under favorable conditions considerable flashing has been observed in the near-nozzle regions. An enormous volume is occupied by the gasoline vapor, stantial computational cost. Volume-averaging instead of mass-averaging is observed to be more effective, especially for finer mesh resolutions.

42 ENGINEERING↗

Simulations of Heat Transfer Using Tight-Fitting Twisted Tape Inserts for First Wall Cooling in Molten Salt Breeder Blankets

One of the major components in fusion energy systems is the fusion blanket, which has a vacuum vessel to contain the plasma. As part of the fusion blanket/vacuum vessel, the first wall and plasma-facing components require sufficient cooling to prevent material degradation during operation from the superheated plasma. Most fusion blanket concepts involve first wall and divertor coolant channels with heat transfer enhancements (HTEs) that are intended to withstand the incident high heat fluxes of 1 to 5 MW/m 2 . Twisted tape inserts are a proposed HTE that have been investigated previously for first wall cooling and monoblock divertor cooling channels and in other nonfusion heat transfer components. By inserting twisted tapes into straight pipes, the amount of turbulence in the system can be increased at lower Reynolds numbers by swirling the flow. This results in better heat transfer characteristics with marginal increases in frictional pressure losses. In particular, simulations of high-Prandtl-number fluids such as the proposed molten salt FLiBe in twisted tapes, which is prototypic to liquid immersion blankets, have not been previously explored. Here, in this study, we simulate various Prandtl numbers in pipes with twisted tape inserts using large eddy simulations to determine the effects of increasing Prandtl numbers on heat transfer performance. The quantities of particular interest are the Nusselt number and the friction factor, which were recovered using data reduction techniques to determine impacts on heat transfer and pressure losses. This work serves as a starting point for determining the feasibility of twisted tape inserts for liquid immersion blanket concepts.

LES↗

Simulation of an Industrial Tangentially Fired Boiler Firing Metallurgical Gases

In industrial environments, boiler units are widely used to supply heat and electrical power. At an integrated steel mill, industrial boilers combust a variable mixture of metallurgical gases combined with additional fuels to generate high-pressure superheated steam. Most tangentially fired boilers have experienced water wall tube failures in the combustion zone, which are thought to be caused by some deficiency in the combustion process. The challenge faced in this present process is that there are very limited means to observe the boiler operation. In our study, a three-dimensional computational fluid dynamics (CFD) modeling and simulation of an industrial tangentially fired boiler firing metallurgical gases was conducted. Eddy dissipation combustion model was applied on this multiple fuel combustion process. Simulation results obtained from the developed CFD model were validated by industrial experiments. Furthermore, a quick comparison of the flame shape from the simulation to the actual flame in the boiler showed a good agreement. We also analyzed the flow field and temperature distribution inside the tangentially fired boiler under the operation conditions, and a wall water tube overheating problem was observed and directly related to the flow

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SERIIUS-MAGEEP Visiting Scholars Program

Recent studies have assessed closed-loop supercritical carbon dioxide (s-CO 2 ) Brayton cycles to be a higher energy-density system in comparison to equivalent superheated steam Rankine systems. At turbine inlet conditions of 700°C and 20 MPa, a cycle thermal efficiency of ~50% can be achieved. Achieving these high efficiencies will help concentrating solar power (CSP) technologies to become a competitive alternative to current power generation methods. To incorporate an s-CO 2 Brayton power cycle in a solar power tower system, the development of a solar receiver capable of providing an outlet temperature of 700°C (at 20 MPa) is necessary. To satisfy the temperature requirements of an s-CO 2 Brayton cycle with recuperation and recompression, the s-CO 2 must undergo a temperature rise of ~200°C as it flows through the solar receiver. The main objective is to develop an optical-thermal-fluid and structural model to validate a tubular receiver that will receive a heat input ~0.33 MWth from the heliostat field at the National Solar Thermal Test Facility (NSTTF), Albuquerque, NM, USA. We also commenced the development of computational models and testing of air receivers being developed by the Indian Institute of Science (IISc) and the Indian Institute of Technology in Bombay (IIT-B). The helical tubular receiver is expected to counteract the effect of thermal expansion while using a cavity to reduce the radiative and convective losses. Initially, this receiver will be tested for a temperature range of 100-300°C under 1 MPa of pressurized air. The helical air receiver will be exposed to 10kWth to achieve a temperature rise of ~200°C. Preliminary tests to validate the modeling will be performed before the design and construction of a larger scale receiver. Lastly, I focused on the development of a new computational tool that would allow us to perform a nodal creep-fatigue analysis on the receivers and heat exchangers being developed. This tool was developed using MATLAB and is capable of processing the results obtained from ANSYS Fluent and Structural combined, which was limited when using commercial software. The main advantage of this code is that it can be modified to run in parallel making it more affordable and faster compared to commercial codes available. The code is in the process of validation and is currently being compared to nCode Design Life.

25 ENERGY STORAGE↗

THREE-DIMENSIONAL THERMAL MODELING ANALYSIS OF CST MEDIA FOR THE SMALL ION EXCHANGE PROJECT

The Small Column Ion Exchange (SCIX) project is designed to accelerate closure of High Level Waste (HLW) tanks at the Savannah River Site (SRS). The SRS tanks store HLW in three forms: sludge, saltcake, and supernate. An in-tank ion exchange process is being designed to treat supernate and dissolved saltcake waste. Through this process, radioactive cesium from the salt solution is adsorbed into Crystalline Silicotitanate (CST) ion exchange media packed within a flow-through column. A packed column loaded with radioactive cesium generates significant heat from radiolytic decay. The waste supernate solution within the ion exchange bed will boil around 120 C. Solution superheating above the boiling point within the column could lead to violent hazardous energy releases. System heating from loaded CST is also of concern in other process modules, such as the waste tank. Due to tank structural integrity concerns, the wall temperature limit for the SRS waste tanks is 100 C. The transfer of cesium-loaded CST to the tank could result in localized hot spots on the tank floor and walls which may exceed this limit. As a result, thermal modeling calculations have been conducted to predict the maximum temperatures achievable both in the column and in the waste tank. As specified in the associated Technical Task Plan, one objective of the present work was to compute temperature distributions within the ion exchange column module under accident scenarios including loss of salt solution flow through the bed and loss of coolant system flow. The column modeling domain and the scope of the calculations in this case were broadened relative to previous two-dimensional calculations to include vertical temperature distributions within the packed bed of ion exchange media as well as the upper column plenum region containing only fluid. The baseline design conditions and in-column modeling domain for the ion-exchange column module are shown in Figure 1. These evaluations assumed the maximum bounding cesium loading considered possible based on current knowledge regarding CST media and the anticipated feed compositions. Since this cesium loading was considerably higher than the nominal loading conditions in SRS waste, cases with lower loading were also evaluated. Modeling parameters were the same as those used previously unless otherwise indicated. The current model does not capture multi-phase cooling mechanisms operative when solution boiling occurs. This feature is conservative in the sense that it does not account for the large cooling effects associated with phase transfer. However, the potential transfer of heat to the plenum region associated with vertical bubble ascension through the column during boiling is also neglected. Thermal modeling calculations were also performed for the entire waste storage tank for the case where loaded and ground CST was transferred to the tank. The modeling domain used for the in-tank calculations is provided in Figure 2. The in-tank domain is based on SRS Tank 41, which is a Type-IIIA tank. Temperature distributions were evaluated for cylindrical, ground CST mounds located on the tank floor. Media grinding is required prior to vitrification processing of the CST in the SRS Defense Waste Processing Facility (DWPF). The location of the heat source region on the tank floor due to the accumulation of CST material was assumed to be just under the grinder. The shape of the CST mound was assumed to be cylindrical. This shape is believed to be most representative of the actual mound shape formed in the tank, given that submersible mixing pumps will be available for media dispersion. Alternative configurations involving other geometrical shapes for the CST mound were evaluated in the previous work. Sensitivity analysis for the in-tank region was performed for different amounts of CST media. As was the case for the in-column model, the in-tank model does not include multi-phase cooling mechanisms operative when solution boiling occurs. The in-column and the in-tank evaluations incorporated recently updated maximum cesium loading levels calculated using the current SCIX feed compositions, which resulted in significantly higher cesium loading than previously calculated. The calculations were conducted to ensure conservative predictions for the maximum temperatures achievable using the current baseline design. The degree of conservatism was reduced for in-column calculations relative to the previous work by using a three-dimensional modeling approach and selecting parameters which were nearer to expected conditions. The degree of conservatism for the in-tank calculations was also reduced by lowering the soil penetration depth below the tank from 150 to 20 feet. The primary goals of the extended thermal modeling effort were to determine whether fluid boiling or superheating are possible within the column module and to determine the maximum floor temperatures within the tank loaded with spent CST.