Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface bonding effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Contamination and Surface Preparation Effects on Composite Bonding

Results presented here demonstrate the effect of several prebond surface contaminants (hydrocarbon, machining fluid, latex, silicone, peel ply residue, release film) on bond quality, as measured by fracture toughness and failure modes of carbon fiber reinforced epoxy substrates bonded in secondary and co-bond configurations with paste and film adhesives. Additionally, the capability of various prebond surface property measurement tools to detect contaminants and potentially predict subsequent bond performance of three different adhesives is also shown. Surface measurement methods included water contact angle, Dyne solution wettability, optically stimulated electron emission spectroscopy, surface free energy, inverse gas chromatography, and Fourier transform infrared spectroscopy with chemometrics analysis. Information will also be provided on the effectiveness of mechanical and energetic surface treatments to recover a bondable surface after contamination. The benefits and drawbacks of the various surface analysis tools to detect contaminants and evaluate prebond surfaces after surface treatment were assessed as well as their ability to correlate to bond performance. Surface analysis tools were also evaluated for their potential use as in-line quality control of adhesive bonding parameters in the manufacturing environment.

Kutscha, Eileen O.↗

Effectiveness of Surface Treatment Techniques for Composite Bonding with Different Contamination Levels

Various surface treatment techniques have been developed to promote adhesive bond performance for composite structural components in aerospace applications. The condition of the pre-bond surface is critical to achieving desirable bond quality. Contamination on bonding surfaces is well recognized as a major threat to ultimate bond performance. Variation in contamination level has brought additional challenges into manufacturing process control. High fidelity surface treatment techniques are required for effective removal of contaminants over a wide range of contamination levels. In this study, a common contaminant, i.e. silicone mold release, was introduced to pre-bond composite surfaces with different concentrations. Plasma and laser surface treatment techniques were performed and their effectiveness in restoring and enhancing desirable bond quality was investigated. Surface characterization techniques, including water contact angle goniometry, Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy, were conducted to assess the condition of contaminated surfaces and the improvement induced by plasma and laser surface treatments. Failure modes from a customized double cantilever beam test were investigated before and after surface treatments. Fundamental mechanisms of plasma and laser surface treatments on the composite bonding surfaces were also investigated.

Fang, Xiaomei↗

Surface Monitoring of CFRP Structures for Adhesive Bonding

Adhesive bonding of composite materials requires reliable monitoring and detection of surface contaminants to assure robust and durable bonded structures. Surface treatment and effective monitoring prior to bonding is essential in order to obtain a surface free from contaminants that may degrade structural performance. Two techniques which monitor the effectiveness of the laser surface treatment of carbon fiber reinforced polymer (CFRP) materials are being investigated: laser induced breakdown spectroscopy (LIBS) and optically stimulated electron emission (OSEE). The applicability of LIBS to detect silicone contaminants on CFRP composites is studied using ~35 ns Nd:YAG laser pulses at 355 nm with a pulse energy of 45 mJ. The LIBS regime in which pulse energies are < 100 mJ is referred to as mLIBS. CFRP surfaces were contaminated with polydimethylsiloxane (PDMS), a major component of silicone based mold release agents. The presence of PDMS is found by inspecting the Si I emission line at 288.2 nm. Untreated CFRP samples and CFRP contaminated with PDMS were tested. The PDMS areal density ranged from 0.36 Â+/- 0.04 to 0.51 Â+/- 0.16 mg/cm2. The results demonstrate the successful detection of PDMS on CFRP using mLIBS. In addition, OSEE was used to measure CFRP surface cleanliness pre- and post-treatment by laser ablation on specimens contaminated with PDMS coatings from 8 nm to 1311 nm in thickness. The results showed a significant increase in the OSEE photocurrent after laser surface treatment.

Ledesma, Rodolfo↗

Surface Characterization of Carbon Fiber Reinforced Polymers by Picosecond Laser Induced Breakdown Spectroscopy

Adhesive bonding of composite materials requires reliable monitoring and detection of surface contaminants as part of a vigorous quality control process to assure robust and durable bonded structures. Surface treatment and effective monitoring prior to bonding are essential in order to obtain a surface which is free from contaminants that may lead to inferior bond quality. In this study, the focus is to advance the laser induced breakdown spectroscopy (LIBS) technique by using pulse energies below 100 μJ (μLIBS) for the detection of low levels of silicone contaminants in carbon fiber reinforced polymer (CFRP) composites. Various CFRP surface conditions were investigated by LIBS using ∼10 ps, 355 nm laser pulses with pulse energies below 30 μJ. Time-resolved analysis was conducted to optimize the gate delay and gate width for the detection of the C I emission line at 247.9 nm to monitor the epoxy resin matrix of CFRP composites and the Si I emission line at 288.2 nm for detection of silicone contaminants in CFRP. To study the surface sensitivity to silicone contamination, CFRP surfaces were coated with polydimethylsiloxane (PDMS), the active ingredient in many mold release agents. The presence of PDMS was studied by inspecting the Si I emission lines at 251.6 nm and 288.2 nm. The measured PDMS areal densities ranged from 0.15 to 2 μg/cm(sup 2). LIBS measurements were performed before and after laser surface ablation. The results demonstrate the successful detection of PDMS thin layers on CFRP using picosecond μLIBS.

Rodolfo Ledesma↗

Enhancement of peptide bond formation by polyribonucleotides on clay surfaces in fluctuating environments

The selective effects of polyribonucleotides on the formation of glycine peptide bonds in glycine on clay surfaces are investigated as a model for a template mechanism for the effects of polynucleotides on peptide bond formation. Free oligoglycine yields were determined for the cycling reaction of glycine in the presence and absence of clay and polyribonucleotides or polydeoxyribonucleotides. The polyribonucleotides are observed to lead to increases of up to fourfold increases in oligoglycine formed, with greater enhancements for poly-G nucleotides than for poly-A, poly-U and poly-C, indicating a codonic bias. Polydeoxyribonucleotides are found to provide no enhancement in peptide formation rates, and yields were also greatly reduced in the absence of clay. A mechanism for peptide synthesis is proposed which involves the activation of glycine on the clay surface, followed by the formation of esters between glycine and the 2-prime OH groups of the polyribonucleotide and peptide bonds between adjacent amino acyl esters. It is pointed out that if this mechanism is correct, it may provide a basis for a direct template translation process, which would produce a singlet genetic code.

White, D. H.↗

Mechanical Tests For Monitoring Aging Of Composites

Experimental study addresses related topics of thermo-oxidative aging of PMR-15 (polyimide matrix/graphite-fiber composite materials) strengths of interfacial bonds, effects of various surface treatments, and relative merits of mechanical tests yielding measures of strengths of materials.

Bowles, Kenneth J.↗

Electrostatic bonding of thin (approximately 3 mil) 7070 cover glass to Ta2O5 AR-coated thin (approximately 2 mil) silicon wafers and solar cells

Electrostatic bonding (ESB) of thin (3 mil) Corning 7070 cover glasses to Ta2O5 AR-coated thin (2 mil) silicon wafers and solar cells is investigated. An experimental program was conducted to establish the effects of variations in pressure, voltage, temperature, time, Ta2O5 thickness, and various prebond glass treatments. Flat wafers without contact grids were used to study the basic effects for bonding to semiconductor surfaces typical of solar cells. Solar cells with three different grid patterns were used to determine additional requirements caused by the raised metallic contacts.

Egelkrout, D. W.↗

Adhesion, friction and micromechanical properties of ceramics

The adhesion, friction, and micromechanical properties of ceramics, both in monolithic and coating form, are reviewed. Ceramics are examined in contact with themselves, other harder materials, and metals. For the simplicity of discussion, the tribological properties of concern in the processes are separated into two parts. The first part discusses the pull-off force (adhesion) and the shear force required to break the interfacial junctions between contacting surfaces. The role of chemical bonding in adhesion and friction, and the effects of surface contaminant films and temperature on tribological response with respect to adhesion and friction are discussed. The second part deals with abrasion of ceramics. Elastic, plastic, and fracture behavior of ceramics in solid state contact is discussed. The scratch technique of determining the critical load needed to fracture interfacial adhesive bonds of ceramic deposited on substrates is also addressed.

Miyoshi, Kazuhisa↗

Adhesion, friction and micromechanical properties of ceramics

The adhesion, friction, and micromechanical properties of ceramics, both in monolithic and coating form, are reviewed. Ceramics are examined in contact with themselves, other harder materials, and metals. For the simplicity of discussion, the tribological properties of concern in the processes are separated into two parts. The first part discusses the pull-off force (adhesion) and the shear force required to break the interfacial junctions between contacting surfaces. The role of chemical bonding in adhesion and friction, and the effects of surface contaminant films and temperature on tribological response with respect to adhesion and friction are discussed. The second part deals with abrasion of ceramics. Elastic, plastic, and fracture behavior of ceramics in solid state contact is discussed. The scratch technique of determining the critical load needed to fracture interfacial adhesive bonds of ceramic deposited on substrates is also addressed.

Miyoshi, Kazuhisa↗

Effect of electronic structure of the diamond surface on the strength of the diamond-metal interface

A diamond surface undergoes a transformation in its electronic structure by a vacuum anneal at approximately 900 C. The polished surface has no electronic states in the band gap, whereas the annealed surface has both occupied and unoccupied states in the and gap and exhibits some electrical conductivity. The effect of this transformation on the strength of the diamond metal interface was investigated by measuring the static friction force of an atomically clean meta sphere on a diamond flat in ultrahigh vacuum. It was found that low friction (weak bonding) is associated with the diamond surface devoid of gap states whereas high friction (strong bonding) is associated with the diamond surface with gap states. Exposure of the annealed surface to excited hydrogen also leads to weak bonding. The interfacial bond is discussed in terms of interaction of the metal conduction band electrons with the band gap states on the diamond surface. Effects of surface electrical conductivity on the interfacial bond are also be considered.

Pepper, S. V.↗

Speedy Acquisition of Surface-Contamination Samples

Biological contamination of large-area surfaces can be determined quickly, inexpensively, and accurately with the aid of a polyester bonded cloth. Cloth is highly effective in removing microbes from a surface and releasing them for biological assay. In releasing contaminants, polyester bonded cloth was found to be superior to other commercial cleanroom cloths, including spun-bound polyamid cloths and cellulose cloths.

Puleo, J. R.↗

Quick-set temporary bonding clamps

Method of bonding materials to a flat surface eliminates the use of bolts to hold the pieces together. Two adhesives are used, the primary or permanent bonding material and a quick setting adhesive. No permanent after effects are left on the surfaces to which the materials are bonded.

Baker, C. D.↗

Evaluation of the interfacial bond properties between carbon phenolic and glass phenolic composites

The effects of moisture and surface finish on the mechanical and physical properties of the interfacial bond between carbon/phenolic (C/P) and glass/phenolic (G/P) composite materials have been studied. Test results indicate that moisture substantially degrades the integrity of the interfacial bond between C/P and G/P materials. The apparent effect of the autoclave curing of the C/P material reduces the ultimate interlaminar shear length of the C/P material by 20 percent compared to the hydroclave curing of the C/P material. The variation in applied surface finishes is found to have no appreciable effect on the ultimate interlaminar shear strength of the interface in the wet laminate.

Jordan, K.↗

Nylon and teflon scribe effect on NBR to Chemlok 233 and NBR to NBR bond interfaces

A study was requested by Manufacturing Engineering to determine what effects marking with nylon (6/6) and Teflon scribes may have on subsequent bonding. Witness panel bond specimens were fabricated by the development lab to test both acrylonitrile butadiene rubber (NBR) to Chemlok and NBR to NBR after controlled exposure. The nylon rod used as a scribe tool demonstrates virtually no bond deterioration when used to scribe lines on either the Chemlok to NBR surfaces or the NBR to NBR interface. Lab test results indicate that the nylon rod-exposed samples produce tensile and peel values very similar to the control samples and the Teflon exposed samples produce tensile and peel values much lower than the control samples. Visual observation of the failure surfaces of the tested samples shows that Teflon scribing produces an obvious contamination to the surface and the nylon produces no effect. Photographs of test samples are provided. It is concluded that Teflon stock used as a scribe tool on a Chemlok 233 to NBR surface or an NBR to NBR surface has a detrimental effect on the bond integrity on either of these bond interfaces. Therefore, it is recommended that the nylon rod continue to be used where a scribe line is required in the redesigned solid rocket motor segment insulation layup operations. The use of Teflon scribes should not be considered.

Jensen, S. K.↗