Swab Tensile Testing Results and Procedures - PA11 Rev. 10 Swabs

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. All swabs were provided by HP and were the PA11 material and Rev 10 design. All of the swabs were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the “Aged” swabs. For the “Aged” swabs, the tensile tests were performed 7 days after the Autoclave pre -treatment. The “Aged” swabs that were not pre-treated using the Autoclave, were tested 7 days after those that were not “Aged.”

36 MATERIALS SCIENCE↗

Swab Testing Results

1. All 3D printed swabs bend to at least 90° without breaking. 2. All 3D printed swabs are at least as strong under tensile testing as their commercial counterparts. a. The Abiogenix FAST Spiral NP and EnvisionTEC swabs retain their tensile strength after sterilization and after 7 days of aging. b. For the Formlabs swabs, steam sterilization significantly reduces their tensile strength, which mostly recovers after 7 days of aging. However, the swabs are stronger than commercial ones at all times. c. The Resolution Medical Lattice swabs retain their tensile strength after 5 days of aging. Five different swab types were tested: 1. Abiogenix FAST Spiral NP Swab; 2. Formlabs NP Swab; 3. EnvisionTEC NP Swab; 4. Resolution Medical Lattice Swab; and 5. Fosun Pharma NP Swab The Abiogenix FAST Spiral NP, EnvisionTEC NP, Resolution Medical Lattice, and Fosun Pharma NP swabs were provided by their respective suppliers. The Formlabs NP swabs were printed at LLNL using the Form 3B Printer and Formlabs Surgical Guide resin

59 BASIC BIOLOGICAL SCIENCES↗

Performance of three-dimensional printed nasopharyngeal swabs for COVID-19 testing

At the start of the COVID-19 pandemic, the US faced nationwide shortages of nasopharyngeal swabs due to both overwhelmed supply chains and an increase in demand. To address this shortfall, multiple 3D printed swabs were ultimately produced and sold for COVID-19 testing. In this work, we present a framework for mechanical and functional bench-testing of nasopharyngeal swabs using standard and widely available material testing equipment. Using this framework, we offer a comprehensive, quantitative comparison of the 3D printed swabs to benchmark their performance against traditional flocked swabs. The test protocols were designed to emulate the clinical use of the nasopharyngeal swabs and to evaluate potential failure modes. Overall, the 3D printed swabs performed comparably to, or outperformed, the traditional swabs in all mechanical tests. While traditional swabs outperformed some of the new 3D printed swabs in terms of sample uptake and retention, similar amounts of RNA were recovered from both 3D printed and traditional swabs.

3D printing↗

Swab Tensile Testing Results and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the “Aged” swabs. For the “Aged” swabs, the tensile tests were performed 7 days after the Autoclave pre -treatment. All swabs were provided by HP.

36 MATERIALS SCIENCE↗

Swab Tensile Testing and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, unless otherwise noted. The FormLabs-USF and FormLabs-Northwell were printed at LLNL using FormLabs Surgical Grade V1 Resin on a Form 3B Printer. Results Summary: All FormLabs design and treatment variations (e.g. autoclaving and “aging”) had higher tensile strength compared commercial swabs. Autoclaving degraded the tensile strength. “Aging” after autoclaving improved the tensile strength. “Aging” without autoclaving degraded the tensile strength. No differences were observed in tensile strength with different autoclaving protocols. No significant differences were observed in tensile strength for different batches.

59 BASIC BIOLOGICAL SCIENCES↗

Swab Tensile Testing Results and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the Injection Molded samples. For the Injection Molded samples, the tensile tests were performed within 24 hours of the completion of the Autoclave pre-treatment. The FormLabs-USF and FormLabs-Northwell were printed at LLNL using FormLabs Surgical Grade V1 Resin on a Form 3B Printer. All other samples were provided by HP.

36 MATERIALS SCIENCE↗

Development of a rapid viability RT-PCR (RV-RT-PCR) method to detect infectious SARS-CoV-2 from swabs

Since the rapid onset of the COVID-19 pandemic, its causative virus, Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2), continues to spread and increase the number of fatalities. To expedite studies on understanding potential surface transmission of the virus and to aid environmental epidemiological investigations, here we developed a rapid viability reverse transcriptase PCR (RV-RT-PCR) method that detects viable (infectious) SARS-CoV-2 from swab samples in <1 day compared to several days required by current gold-standard cell-culture-based methods. The method integrates cell-culture-based viral enrichment in a 96-well plate format with gene-specific RT-PCR-based analysis before and after sample incubation to determine the cycle threshold (C T ) difference (ΔC T ). An algorithm based on ΔC T ≥ 6 representing ~ 2-log or more increase in SARS-CoV-2 RNA following enrichment determines the presence of infectious virus. The RV-RT-PCR method with 2-hr viral infection and 9-hr post-infection incubation periods includes ultrafiltration to concentrate virions, resulting in detection of <50 SARS-CoV-2 virions in swab samples in 17 h (for a batch of 12 swabs), compared to days typically required by the cell-culture-based method. The SARS-CoV-2 RV-RT-PCR method may also be useful in clinical sample analysis and antiviral drug testing, and could serve as a model for developing rapid methods for other viruses of concern.

60 APPLIED LIFE SCIENCES↗

Swab Testing Results Summary

Swabs Tested: 1. FAST Spiral NP Swab, designed and supplied by Abiogenix, printed from polyamide 11 (Nylon) using HP Multi Jet Fusion printers. 2. NP Swab designed by USF Health and Northwell Health in collaboration with Formlabs. Printed at LLNL using the Form 3B stereolithography printer in Formlabs Surgical Guide resin.

42 ENGINEERING↗

Rapid, Sensitive, Label-Free Electrical Detection of SARS-CoV-2 in Nasal Swab Samples

Rapid diagnosis of coronavirus disease 2019 (COVID-19) is key for the long-term control of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) amid renewed threats of mutated SARS-CoV-2 around the world. Here, we report on an electrical label-free detection of SARS-CoV-2 in nasopharyngeal swab samples directly collected from outpatients or in saliva-relevant conditions by using a remote floating-gate field-effect transistor (RFGFET) with a 2-dimensional reduced graphene oxide (rGO) sensing membrane. RFGFET sensors demonstrate rapid detection (<5 min), a 90.6% accuracy from 8 nasal swab samples measured by 4 different devices for each sample, and a coefficient of variation (CV) < 6%. Also, RFGFET sensors display a limit of detection (LOD) of pseudo-SARS-CoV-2 that is 10 000-fold lower than enzyme-linked immunosorbent assays, with a comparable LOD to that of reverse transcriptionpolymerase chain reaction (RT-PCR) for patient samples. To achieve this, comprehensive systematic studies were performed regarding interactions between SARS-CoV-2 and spike proteins, neutralizing antibodies, and angiotensin-converting enzyme 2, as either a biomarker (detection target) or a sensing probe (receptor) functionalized on the rGO sensing membrane. Finally, taken together, this work may have an immense effect on positioning FET bioelectronics for rapid SARS-CoV-2 diagnostics.

60 APPLIED LIFE SCIENCES↗

Swab Tensile Testing Results [Slides]

HP PA11 material swabs predominantly broke at the joint between the head and the neck, although there was significant variation in the break locations. HP PA12, Injection Molded, and FormLabs (Surgical Guide V1 Resin) material swabs predominately broke in the neck region.

36 MATERIALS SCIENCE↗

Swab Tensile Testing - HP Rev 10 Summary

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking.

42 ENGINEERING↗

Swab Testing Results- HP PA11 Rev 8 Summary

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking.

42 ENGINEERING↗

Success Using A Granular-Activated Carbon Filtration Swab to Rehabilitate Westbay{sup R} Multi-level Groundwater Monitoring Wells at the INL - 20544

In November 2015, tetrachloroethylene (PCE) was discovered in groundwater samples collected from a Westbay{sup R} multi-level groundwater monitoring well at the Idaho National Laboratory (INL).a Subsequent investigation determined that PCE was not present in the groundwater. The detected PCE was instead due to inadvertent contamination of the internal tubing fluid in the Westbay well-monitoring system, which is isolated from the surrounding groundwater. Further investigation showed that three of the 11 Westbay wells at the INL contained PCE-contaminated tubing fluid at concentrations above the U.S. Environmental Protection Agency's maximum contaminant level for drinking water (5 μg/L). Loose sediment at the bottom of some Westbay wells was also found to contain PCE; the three wells were then identified for rehabilitation as part of the INL well maintenance program. The unique construction of the Westbay wells - i.e., the small diameter (5.72 cm [2.25 in.]) and the depths of the tubing fluid ranging from 144.8 to 419 m (475 to 1,376 ft) below ground surface - posed unique challenges to the rehabilitation. Because the tubing fluid provides structural integrity, the fluid cannot be removed and then replaced without damaging the integrity of the Westbay well. Additionally, the small diameter of the systems and the associated depths limit the availability of equipment that can be used for the rehabilitation. After an evaluation of potential methods, it was determined that the use of an in-well, custom-fabricated, granular-activated-carbon filtration swab deployed via a wire line would provide the safest and most cost-effective method for rehabilitation. Westbay well rehabilitation started at well MIDDLE-2051 in late June 2018 and paused in December 2018 for the season. The PCE concentration in the tubing fluid at MIDDLE-2051 was initially reduced to a maximum concentration of 3.81 μg/L from a maximum of 642 μg/L, while the concentration of PCE in the sediment had been reduced from 5,360 to 2,270 μg/kg. Sampling was performed at MIDDLE-2051 again in August 2019, and the tubing fluid increased to a maximum concentration of 45.4 μg/L, while the concentration in the sediment decreased further to 1,890 μg/kg due to desorption of PCE from the sediment to the tubing fluid. Rehabilitation resumed at well MIDDLE-2050A in late August 2019, and the PCE concentration in the tubing fluid had been reduced to a maximum concentration of 19.0 μg/L. Although the method has been shown to be time-consuming, it has proven to be effective and safe for personnel performing the work and to the integrity of the well. Future sample data results at all wells will help determine an estimated completion of the rehabilitation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tissue replication and mucosal swab detection of Sosuga virus in Syrian hamsters in the absence of overt tissue pathology and clinical disease

Human infection with Sosuga virus (SOSV), a recently discovered pathogenic paramyxovirus, has been reported in one individual to date. No animal models of disease are currently available for SOSV. Here, we describe initial characterization of experimental infection in Syrian hamsters, including kinetics of virus dissemination and replication, and the corresponding clinical parameters, immunological responses, and histopathology. Here, we demonstrate susceptibility of hamsters to infection in the absence of clinical signs or significant histopathologic findings in tissues.

60 APPLIED LIFE SCIENCES↗

Recovery of DNA from fired and unfired cartridge casings: comparison of two DNA collection methods

For over 10 years, various studies have attempted to increase the recovery of DNA from ammunition by modifying the DNA collection, extraction, purification, and amplification procedures, with varying levels of success. This study focused on the “soaking” method of Montpetit & O’Donnell [1] and the “rinse-and-swab" method of Bille et al. [2]. First, testing for the presence of exogenous DNA, 210 boxed cartridges (brass, steel, and nickel-plated) from nine manufacturers were swabbed and DNA was extracted, concentrated, and quantified. Extracts that quantified > 0 ng/µL (44 of 210) were amplified and genotyped with GlobalFiler™. Of those, only one extract yielded two alleles indicating that the manufacturing and packaging of ammunition was virtually DNA free. Next, to obtain a baseline comparison of two DNA collection methods on a non-metallic substrate and identify a suitable number of cells to spot on cartridges, different DNA input amounts of primary human adult epidermal keratinocytes (HEKa) were tested. Thereafter, 300 brass and 300 nickel-plated, cartridges were spotted with HEKa cells containing ~5 ng of DNA, fired or unfired, and processed with either method. Finally, five methods representing hybrids of the soaking and rinse-and-swab methods were tested to determine if variations of those methods could be used to increase DNA yield and recovery. The results show that the soaking method consistently yielded more DNA than the rinse-and-swab method from a non-metallic substrate. However, the comparison study demonstrated that both methods performed comparably for cartridges. On average, the soaking method recovered 0.25 ng of DNA (5.1% recovery) and the rinse-and-swab method recovered 0.28 ng (5.8% recovery). However, average recoveries were significantly different among three analysts and considerable variation in yields were observed, possibly due to storage time. Furthermore, consistent with prior reports, the DNA recovered from brass casings was only 16% of that recovered from nickel-plated casings and the average yield of DNA from fired casings was reduced to 67% of unfired casings. Moreover, DNA extracts from brass or nickel-plated casings did not appear to contain amplification inhibitors and only 30/596 appeared severely degraded. Finally, both the published rinse-and-swab and soaking methods yielded more DNA than all modifications of the two methods. Overall, both methods yielded equivalent DNA quantities. Additionally, recovery of DNA from any given cartridge casing may be dependent on storage time as well as the skill, proficiency, and experience of the analyst and may reflect stochastic effects, particularly for casings containing low copy and/or degraded DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of sampling techniques on short-term survival and genotyping success of salmonid fry

ABSTRACT Objective Genetics tools have become an integral part of managing and understanding fish populations. Generally, a small tissue sample, such as a fin clip, is taken and then genotyped, with little effect on survival of the fish. However, tissue sampling may have a larger effect on juvenile fish survival compared to their adult counterparts. We evaluated survival and genotyping success of various genetic sampling techniques for Chinook Salmon Oncorhynchus tshawytscha and Rainbow Trout Oncorhynchus mykiss fry. Methods Three sampling treatments were evaluated including control (anesthetized and handled), fin clipping (partial caudal fin clip), and swabbing (OmniSwab was used to collect external mucus). Survival was monitored for 12 d posttreatment, and genotyping success was evaluated. Results Survival was high in all treatment groups (i.e., 0.93–1.00) but, on average, was lower in the swab treatment group. Genotyping was successful in 100% of the fin clip samples and 11–50% of the swab samples. Conclusions Results of this study suggest that sampling caudal-fin tissue does not negatively affect fry short-term survival and the small tissue samples yield highly successful genotyping results. Swabbing did not produce successful genotyping results, and fish sampled with swabs experienced higher mortality than those that received fin clips. Results indicate that fin clips should be used for collection of genetic samples from fry.

McCarrick, Darcy K.↗

Temporal Characterization of Tritium Smear Activities

Tritium collection efficiency varies as a function of smear media. The use of porous smear materials leads to an increase in the measured tritium activity as a function of time when the measurement is performed with liquid scintillation counters. Operational inclusion of the efficiency differences and the time dependence of the tritium smear activity is necessary to preclude inadvertently releasing materials or areas. Thomas Jefferson National Laboratory Radiological Control Department identified a contaminated stainless steel containment vessel that previously housed a target containing more than 37 TBq of tritium. The item was systematically sectioned and surveyed to compare three smear types: water-wetted cotton swabs, water-wetted paper smears, and ethanol-wetted Styrofoam wipes (NUC-Wipes™). The total activity of each section was determined using repeated decontamination. The time dependence of the measured activity was also studied. The measured activity of both paper smears and cotton swabs showed significant time dependence. The cotton swabs also showed significantly reduced collection efficiency. Given the widespread use of both of these media in routine contamination surveys, site operational limits were derived using fitted curves for time dependence and average efficiency results. In conclusion, the use of these more restrictive limits allows for rapid measurement of tritium smears while ensuring regulatory compliance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗