Search NASA⌕ Search

SEARCH · Search NASA

Results for “sweat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A wearable patch for continuous analysis of thermoregulatory sweat at rest

The body naturally and continuously secretes sweat for thermoregulation during sedentary and routine activities at rates that can reflect underlying health conditions, including nerve damage, autonomic and metabolic disorders, and chronic stress. However, low secretion rates and evaporation pose challenges for collecting resting thermoregulatory sweat for non-invasive analysis of body physiology. Here we present wearable patches for continuous sweat monitoring at rest, using microfluidics to combat evaporation and enable selective monitoring of secretion rate. We integrate hydrophilic fillers for rapid sweat uptake into the sensing channel, reducing required sweat accumulation time towards real-time measurement. Along with sweat rate sensors, we integrate electrochemical sensors for pH, Cl - , and levodopa monitoring. We demonstrate patch functionality for dynamic sweat analysis related to routine activities, stress events, hypoglycemia-induced sweating, and Parkinson’s disease. By enabling sweat analysis compatible with sedentary, routine, and daily activities, these patches enable continuous, autonomous monitoring of body physiology at rest.

47 OTHER INSTRUMENTATION↗

Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities

Electrodermal activity has long been used for mental activity monitoring by measuring skin conductance at specific locations, such as fingertips, with high sweat gland density. However, electrodermal activity has not been considered useful for physical activity monitoring, where large sweat volumes are generated, resulting in the accumulation of sweat at the skin–electrode interface and, thus, preventing further dynamic response to sweating events. Here we show that electrodermal activity can be used as a proxy for sweat loss measurement under both low and high physical activity levels. We use wearable sweat sensors that consist of water-permeable electrodes and microfluidic-based sweat analysers, and show that skin conductance is proportional to the instantaneous sweat loss. We demonstrate that sweat loss during exercise can be estimated by integrating skin conductance over time, which can be applied to assess the body hydration status of exercisers. From multisite measurements of skin conductance, we show that the wrist, forearm and upper arm are reflective of physical activity levels, whereas the finger is indicative of mental activity. Simultaneous measurement of two different sites selectively decouples mental and physical activities.

Biomedical engineering↗

Glove-based sensors for multimodal monitoring of natural sweat

Sweat sensors targeting exercise or chemically induced sweat have shown promise for noninvasive health monitoring. Natural thermoregulatory sweat is an attractive alternative as it can be accessed during routine and sedentary activity without impeding user lifestyles and potentially preserves correlations between sweat and blood biomarkers. We present simple glove-based sensors to accumulate natural sweat with minimal evaporation, capitalizing on high sweat gland densities to collect hundreds of microliters in just 30 min without active sweat stimulation. Sensing electrodes are patterned on nitrile gloves and finger cots for in situ detection of diverse biomarkers, including electrolytes and xenobiotics, and multiple gloves or cots are worn in sequence to track overarching analyte dynamics. Direct integration of sensors into gloves represents a simple and low-overhead scheme for natural sweat analysis, enabling sweat-based physiological monitoring to become practical and routine without requiring highly complex or miniaturized components for analyte collection and signal transduction.

42 ENGINEERING↗

Integrated cooling (i-Cool) textile of heat conduction and sweat transportation for personal perspiration management

Perspiration evaporation plays an indispensable role in human body heat dissipation. However, conventional textiles tend to focus on sweat removal and pay little attention to the basic thermoregulation function of sweat, showing limited evaporation ability and cooling efficiency in moderate/profuse perspiration scenarios. Here, we propose an integrated cooling (i-Cool) textile with unique functional structure design for personal perspiration management. By integrating heat conductive pathways and water transport channels decently, i-Cool exhibits enhanced evaporation ability and high sweat evaporative cooling efficiency, not merely liquid sweat wicking function. In the steady-state evaporation test, compared to cotton, up to over 100% reduction in water mass gain ratio, and 3 times higher skin power density increment for every unit of sweat evaporation are demonstrated. Besides, i-Cool shows about 3 °C cooling effect with greatly reduced sweat consumption than cotton in the artificial sweating skin test. The practical application feasibility of i-Cool design principles is well validated based on commercial fabrics. Owing to its exceptional personal perspiration management performance, we expect the i-Cool concept can provide promising design guidelines for next-generation perspiration management textiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nicotine Monitoring with a Wearable Sweat Band

The tobacco epidemic is a public health threat that has taken a heavy toll of lives around the globe each year. Smoking affects both the smokers and those who are exposed to secondhand smoke, and careful tracking of exposure can be key to mitigating the potential hazards. For smokers, the variation of chemical compositions between commercial cigarettes has led to ambiguity in estimating the health risks, both for active smokers and others involuntarily exposed to tobacco smoke and byproducts. In this regard, sweat possesses an attractive opportunity to monitor smoke exposure due to sweat's abundance in biomolecules and its great accessibility. In this paper, we present a wearable sweat band to monitor nicotine, a prominent ingredient in cigarettes, as a viable way to quantitatively assess a wearer's exposure to smoking. Both smokers and normal subjects are tested to demonstrate the use of this device for smoke-related health monitoring. Our results exhibit confirmable and elevated nicotine levels in sweat for subjects inhaling cigarette smoke. This continuous and personalized sweat sensing device is leverage to monitor smoke pollution for a potentially broad population.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An engineered lactate oxidase based electrochemical sensor for continuous detection of biomarker lactic acid in human sweat and serum

Lactate levels in humans reveal intensity and duration of exertion and provide a critical readout for the severity of life-threatening illnesses such as pediatric sepsis. Using the lactate oxidase enzyme (Lox) from Aerococcus viridians, we demonstrated its functionality for lactate electrochemical sensing in physiological fluids in a lab setting. The structure and dynamics of LOx were validated by crystallography, X-ray scattering, and hydroxyl radical protein footprinting. This provided a validated protein template for understanding and designing an enzyme-based electrochemical sensing elements. Using this template, LOx enzyme variants were generated and compared. Comparison of the variants demonstrates that one exhibits effective lactate sensing at significantly reduced operating voltages. Additionally, we demonstrate that the four hexahistidine-tags on each enzyme tetramer are sufficient for immobilization to create a durable, functional sensor, with no need for a covalent attachment, enabling self-immobilization and eliminating the need for additional immobilization steps. The functionality of the LOx enzyme variants was verified at physiological lactate concentrations in both human serum (0–4 mM) and artificial sweat (0–100 mM) using 3-electrode setups for analysis of the three variants in parallel. Accuracy of measurement in both artificial sweat and human serum were high. Employing a microfluidic flow cell, we successfully monitored varying lactate levels in physiological fluids continuously over a 2h period. Overall, this optimized LOx enzyme, which self-immobilizes onto gold sensing electrodes, facilitates efficient and reliable lactate detection and continuous monitoring at reduced operating voltages suitable for further development towards commercial use.

60 APPLIED LIFE SCIENCES↗

Human‐Skin‐Inspired Adaptive Smart Textiles Capable of Amplified Latent Heat Transfer for Thermal Comfort

Thermally adaptive textiles (TATs) enable human subjects to attain thermal comfort without energy consumption, which can lead to enormous energy savings on heating, ventilation, and air conditioning (HVAC) in buildings. Herein, TAT structures which respond to the sweat and generate pores by opening an array of flap‐shaped pores patterned on the fabric surface are proposed. A moisture‐driven self‐actuator for flap opening by constructing a bilayer consisting of a hygroscopic layer using polyethylene glycol and cellulose acetate, and a hydrophobic polymer using a polyester type polymer, is used and successfully demonstrated an essentially instant 4 °C apparent temperature cooling performance within one minute of sweat–humidity‐initiated actuation while wearing TAT using a sweating skin simulated device.

Kim, Gunwoo↗

Soil properties and biochemical composition of ground-dwelling bee nests in agricultural settings

Soils deliver underrecognized ecosystem services by supplying habitat for ground-dwelling pollinators, such as wild bees and other organisms, that pollinate 80% of insect-pollinated plants and play a critical role in securing resilient pollination provisions. Our objective is to identify soil properties of ground nesting bee nests in agricultural settings of western Oregon, USA. We confirmed ground nesting bee and sand wasp activity in 7 agricultural sites and 1 recreational park. Soils from 17 bee and sand wasp nests were analyzed for pH, particle size distribution, and carbon and nitrogen content. We visually confirmed that 8 of the nesting bees were sweat bees from the Halictidae family and identified a captured bee specimen as Lasioglossum (Dialictus) (Hymenoptera: Halictidae). We located 2 sites with sand wasps where specimens were identified as Cerceris and Bembix (Hymenoptera: Crabronidae). The organic matter composition of three soil samples scraped from the linings of active nests were assessed using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The FTICR-MS results identified unknown lipid compounds in the nest soil samples, which we hypothesize are waterproofing lipids secreted to line cell walls. Bee nests occurred in slightly acidic, bare-ground soils with low rock/vegetation coverage, low organic carbon content (<1%), and exhibited significantly higher silt-plus-clay fractions (>75%) versus data published for bee nests in prior work. Our findings present important implications for textural controls on nest site selection in wet, cool environments and demonstrate the importance of integrating soil properties to improve our understanding of ground-dwelling organisms and associated soil habitats.

59 BASIC BIOLOGICAL SCIENCES↗

Single-atom materials boosting wearable orthogonal uric acid detection

Abstract Uric acid (UA) is a vital biomarker for the diagnosis and management of various health conditions, including cardiovascular diseases, gout, kidney disorders, metabolic syndrome, and wound healing. Despite significant advances in wearable sensor technology, challenges persist in developing wearable sensors that are capable of maintaining high sensitivity, selectivity, and stability. In this study, we present an epidermal sensing platform enhanced with single-atom materials (SAMs) designed for flexible and orthogonal electrochemical detection of UA. We designed and synthesized an SAM with Fe-N 5 active sites to boost the electrochemical sensing signals, integrating it with laser-engraved graphene (LEG) to fabricate a wearable SAM-based UA patch sensor. This design provides superior UA detection performance compared to sensors based on conventional nanomaterials. In addition, we enhanced the detection accuracy and range by using an orthogonal approach that combines direct oxidation through differential pulse voltammetry (DPV) along with parallel biocatalytic amperometric detection. The resulting SAM-based UA orthogonal sensor patch demonstrated exceptional performance in wearable applications through tests measuring sweat UA levels in subjects before and after consuming a purine-rich diet. Graphical Abstract

Ding, Shichao↗

Compromise of Personal Protective Clothing from Liquid Exposure

Following critiques of multiple personal contamination events from entries into the Oak Ridge National Laboratory’s Spallation Neutron Source transfer bay, it was considered that the most likely causes for contamination were personal protective clothing doffing errors or that moisture (sweat) allowed contamination to wick through the protective clothing. To pursue this issue, radiological protection staff looked more closely, however, at the specific area of the clothing where contamination was highest; under enhanced lighting and photochromic manipulation, there appeared to have been some type of moisture in the area. Recognizing the possibility that moisture may have allowed for migration of contamination through the clothing, further experiments were undertaken to determine under which conditions this transport might have occurred. The objective for this work was to identify the susceptibility of different types of personal protective clothing to various liquids encountered in the workplace.Method: Several tests were performed to determine if perspiration had enabled migration of contamination, and to identify what other liquids might have affected contamination transport. Two layers of personal protective clothing were subjected to static conditions and dynamic conditions, to include active rubbing of the materials while wet. Food dye added to each of the liquids tested enabled visual indications of liquid breakthrough. Additional tests were conducted to see if solid contamination could be transported through the materials along with the liquids. As a result, it was found that all but one type of non-rubberized personal protective clothing in use at Oak Ridge National Laboratory were permanently compromised to some extent by the solvents used for decontamination. It was determined that most common cleaning agents immediately and permanently destroyed the hydrophobic nature of several of the splash-resistant protective clothing materials, allowing for radioactive contamination to penetrate through the material to the worker. Work around wet surfaces or performing wet decontamination will only be performed in protective clothing known to prevent transport of the wetting agent.

61 RADIATION PROTECTION AND DOSIMETRY↗

Freestanding VO 2 membranes on epidermal nanomesh for ultra-sensitive correlated breathable sensors

The interest in highly sensitive sensors is rapidly increasing for detecting very tiny signals for Internet of Things devices. Here, we achieve ultra-sensitive correlated breathable sensors based on freestanding VO 2 membranes. We fabricate the membranes by growing VO 2 films onto sacrificial Sr 3 Al 2 O 6 layer grown on SrTiO 3 , selectively dissolving the Sr 3 Al 2 O 6 in water, and then rendering freestanding VO 2 membrane on nanomesh. The nanomeshes are extremely flexible, sweat permeable, and readily skin-adhesive. The resistance of the VO 2 membranes is reversibly tuned by human’s tiny mechanical stimuli and breath stimuli. The stimuli modulate the Peierls dimerization of one-dimensional V-V chains in the VO 2 lattice which concomitantly controls the electron correlation and hence resistivity. Since our breathable sensors operate based on quantum-mechanical correlation effects, their sensitivity is 1-2 orders of magnitude higher than conventional tactile and respiratory sensors based on other materials. Thus, the freestanding membranes of correlated oxides on epidermal nanomeshes are multifunctional platforms for developing ultra-sensitive correlated breathable sensors.

36 MATERIALS SCIENCE↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supersonic hot jet ablative testing and analysis of boron nitride nanotube hybrid composites

Boron nitride nanotubes (BNNTs) are high-strength, high-modulus nanotubes with high thermal and oxidative stabilities. Two hybrid composites were prepared with satin weave carbon fiber (CF) and resole-type phenolic resin: one with surface layers of BNNTs and one with alternating interlayers of BNNTs. The samples were subjected to hot jet tests that simulate realistic high-pressure-temperature conditions to understand the behavior of BNNTs under high-pressure erosion. Adding BNNTs to CF/phenolic laminates enhanced the ablation resistance by reinforcing the char material and mitigated localized thermal damage. Hybrid laminates exhibited up to 14% lower weight loss, 55% increase in flexural modulus, higher thermal diffusivity, and improved char yield and microstructure compared to CF/phenolic samples. The surface layer hybrid had many surviving nanotubes reinforcing the char and crystalline oxide structures that could mitigate further oxygen diffusion. Further, various characterization methods were used to deduce possible mechanisms and their products, indicating that BNNTs could serve as growth templates for direct crystalline boron oxide formation. Overall, hybrid BNNT/CF/phenolic laminates displayed better ablation resistance and favorable microstructure evolution under high-pressure conditions.

42 ENGINEERING↗

Trace explosives sampling for security applications (TESSA) study: Evaluation of procedures and methodology for contact sampling efficiency

We report the detection of trace amounts of explosive materials is critical to the security at mass transit centers (e.g., airports and railway stations). In a typical screening process, a trap is used to probe a surface of interest to collect and transfer particulate residue to a detector for analysis. The collection of residues from the surface being probed is widely viewed as the limiting step in this process. A multi-institutional study was performed to establish a methodology for the evaluation of sampling media collection efficiencies. Dry deposited residues of 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), C-4 (an RDX-based explosive), and pentaerythritol tetranitrate (PETN) were harvested from acrylonitrile butadiene styrene (ABS) plastic, ballistic nylon (NYL), and uncoated aluminum surfaces using muslin, Texwipe cotton, and stainless-steel mesh traps. Transfer and collection efficiencies of the sample media were calculated based on liquid chromatography-mass spectrometry analysis. Dry transfer efficiencies (DTE%) to all tested surfaces were greater than 75%, with transfer to ABS plastic being the lowest. Collection efficiency (CE%) varied significantly across the traps and the surfaces, yet some conclusions can be drawn; nylon had the lowest CE% for all cases (~10%), and the stainless steel mesh had the lowest CE% for the evaluated traps (~20%). Though the testing parameters have been standardized among the participants to establish a framework for an independent comparison of contact sampling media and surfaces, substantial variations in the DTE% and the CE% were observed, suggesting that other variables can affect contact sampling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗