Revisiting Short-Wave-Infrared (SWIR) Bands for Atmospheric Correction in Coastal Waters

The shortwave infrared (SWIR) bands on the existing Earth Observing missions like MODIS have been designed to meet land and atmospheric science requirements. The future geostationary and polar-orbiting ocean color missions, however, require highly sensitive SWIR bands (greater than 1550nm) to allow for a precise removal of aerosol contributions. This will allow for reasonable retrievals of the remote sensing reflectance (R(sub rs)) using standard NASA atmospheric corrections over turbid coastal waters. Design, fabrication, and maintaining high-performance SWIR bands at very low signal levels bear significant costs on dedicated ocean color missions. This study aims at providing a full analysis of the utility of alternative SWIR bands within the 1600nm atmospheric window if the bands within the 2200nm window were to be excluded due to engineering/cost constraints. Following a series of sensitivity analyses for various spectral band configurations as a function of water vapor amount, we chose spectral bands centered at 1565 and 1675nm as suitable alternative bands within the 1600nm window for a future geostationary imager. The sensitivity of this band combination to different aerosol conditions, calibration uncertainties, and extreme water turbidity were studied and compared with that of all band combinations available on existing polar-orbiting missions. The combination of the alternative channels was shown to be as sensitive to test aerosol models as existing near-infrared (NIR) band combinations (e.g., 748 and 869nm) over clear open ocean waters. It was further demonstrated that while in extremely turbid waters the 1565/1675 band pair yields R(sub rs) retrievals as good as those derived from all other existing SWIR band pairs (greater than 1550nm), their total calibration uncertainties must be less than 1% to meet current science requirements for ocean color retrievals (i.e., delta R(sub rs) (443) less than 5%). We further show that the aerosol removal using the NIR and SWIR bands (available on the existing polar-orbiting missions) can be very sensitive to calibration uncertainties. This requires the need for monitoring the calibration of these bands to ensure consistent multi-mission ocean color products in coastal/inland waters.

atmospheric correction↗

Analysis of the on-orbit Response-Versus-Scan-angle for the MODIS SWIR Bands Derived from Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Terra and Aqua platforms is a multi-spectral, whiskbroom scanning radiometer with 36 spectral bands covering wavelengths from 0:4 - 14:2 μm. Among these bands, the 20 reflective solar bands (RSB, 0:4 - 2:1 μm) use an on-board solar difuser (SD) and SD stability monitor (SDSM) to track the detector gain changes on orbit. In addition to this, lunar and Earth-view (EV) observations are used in order to characterize the scan-mirror response versus scan angle (RVS), which improves the Earth-view retrieval over the full width of each scan. For the short-wave infrared bands (SWIR, 1:2 - 2:1 μm), the prelaunch RVS has been used for both Aqua and Terra MODIS throughout each mission. While these bands are not expected to have a significant change in the RVS on-orbit, issues such as electronic crosstalk and an out-of-band optical leak have prevented the use of the Moon for deriving the on-orbit RVS for validation. However, recent improvements to the MODIS lunar calibration for the SWIR bands allow us to mitigate the electronic crosstalk impact and derive the RVS for the SWIR bands. In this work, we will assess the impact of this newly derived RVS on the EV data compared to MODIS Collection 6.1. By comparing to EV data obtained from pseudo-invariant calibration sites at different angles-of-incidence on the scan mirror, we can assess the effectiveness of the newly derived RVS from the Moon. We find that while the change in the RVS on-orbit for the SWIR bands is relatively small, applying a correction to the RVS based on the Moon and SD data can provide an improvement for some bands.

MODIS↗

Evaluation of SWIR Crop Residue Bands for the Landsat Next Mission

This research reports the findings of a Landsat Next expert review panel that evaluated the use of narrow shortwave infrared (SWIR) reflectance bands to measure ligno-cellulose absorption features centered near 2100 and 2300 nm, with the objective of measuring and mapping non-photosynthetic vegetation (NPV), crop residue cover, and the adoption of conservation tillage practices within agricultural landscapes. Results could also apply to detection of NPV in pasture, grazing lands, and non-agricultural settings. Currently, there are no satellite data sources that provide narrowband or hyperspectral SWIR imagery at sufficient volume to map NPV at a regional scale. The Landsat Next mission, currently under design and expected to launch in the late 2020’s, provides the opportunity for achieving increased SWIR sampling and spectral resolution with the adoption of new sensor technology. This study employed hyperspectral data collected from 916 agricultural field locations with varying fractional NPV, fractional green vegetation, and surface moisture contents. These spectra were processed to generate narrow bands with centers at 2040, 2100, 2210, 2260, and 2230 nm, at various bandwidths, that were subsequently used to derive 13 NPV spectral indices from each spectrum. For crop residues with minimal green vegetation cover, two-band indices derived from 2210 and 2260 nm bands were top performers for measuring NPV (R^(2) = 0.81, RMSE = 0.13) using bandwidths of 30 to 50 nm, and the addition of a third band at 2100 nm increased resistance to atmospheric correction residuals and improved mission continuity with Landsat 8 Operational Land Imager Band 7. For prediction of NPV over a full range of green vegetation cover, the Cellulose Absorption Index, derived from 2040, 2100, and 2210 nm bands, was top performer (R^(2) = 0.77, RMSE = 0.17), but required a narrow (≤20 nm) bandwidth at 2040 nm to avoid interference from atmospheric carbon dioxide absorption. In comparison, broadband NPV indices utilizing Landsat 8 bands centered at 1610 and 2200 nm performed poorly in measuring fractional NPV (R^(2) = 0.44), with significantly increased interference from green vegetation

Wells Dean Hively↗

MLA instruments and SWIR focal-plane technology

It is pointed out that next-generation sensors for earth observation will utilize Multispectral Linear Array (MLA) technology wherein linear detector arrays will scan the earth in pushbroom fashion. MLA instruments will permit a dramatic increase in detector dwell time, which can be utilized to improve spatial, spectral, and radiometric resolution. In connection with the considered applications for MLA sensors, the employed detector arrays should cover the visible, near-infrared, and shortwave infrared (SWIR) spectral bands. The present paper is mainly concerned with the development of mercury-cadmium-telluride focal-plane arrays for the SWIR spectral regime (1-2.5 microns). Attention is given to the requirements, design details regarding the detector array, the employed multiplexer technique, the hybrid concept, packaging, and the program status.

Brown, F. G.↗

An evaluation of short-wave-infrared (SWIR) data from the AVIRIS and GEOSCAN instruments for mineralogical mapping at Cuprite, Nevada

An evaluation was performed on SWIR (2000-2400 nm) data from two airborne remote sensing systems for discriminating and identifying alteration minerals at Cuprite, Nevada. The data were acquired by the NASA Airborne Visible/InfraRed Imaging Spectrometer (AVIRIS) and the GEOSCAN Mk II multispectral scanner. The evaluation involved comparison of processed imagery and image-derived spectra with existing alteration maps and laboratory spectra of rock samples from Cuprite. Results indicate that both the AVIRIS and GEOSCAN data permit the discrimination of areas of alunite, buddingtonite, kaolinite, and silicification using color composite images formed from three SWIR bands processed with either the decorrelation stretch or a log residual algorithm. The laboratory spectral features alunite, kaolinite and buddingtonite could be seen clearly only in the log residual processed AVIRIS data. However, this does not preclude their identification with the GEOSCAN data.

Hook, Simon J.↗

Impact of MODIS SWIR Band Calibration Improvements on Level-3 Atmospheric Products

The spectral reflectance measured by the MODIS reflective solar bands (RSB) is used for retrieving many atmospheric science products. The accuracy of these products depends on the accuracy of the calibration of the RSB. To this end, the RSB of the MODIS instruments are primarily calibrated on-orbit using regular solar diffuser (SD) observations. For lambda < 0.94 microns the SDs on-orbit bi-directional reflectance factor (BRF) change is tracked using solar diffuser stability monitor (SDSM) observations. For lambda > 0.94 microns, the MODIS Characterization Support Team (MCST) developed, in MODIS Collection 6 (C6), a time-dependent correction using observations from pseudo-invariant earth-scene targets. This correction has been implemented in C6 for the Terra MODIS 1.24 micron band over the entire mission, and for the 1.375 micron band in the forward processing. As the instruments continue to operate beyond their design lifetime of six years, a similar correction is planned for other short-wave infrared (SWIR) bands as well. MODIS SWIR bands are used in deriving atmosphere products, including aerosol optical thickness, atmospheric total column water vapor, cloud fraction and cloud optical depth. The SD degradation correction in Terra bands 5 and 26 impact the spectral radiance and therefore the retrieval of these atmosphere products. Here, we describe the corrections to Bands 5 (1.24 microns) and 26 (1.375 microns), and produce three sets (B5, B26 correction on/on, on/off, and off/off) of Terra-MODIS Level 1B (calibrated radiance product) data. By comparing products derived from these corrected and uncorrected Terra MODIS Level 1B (L1B) calibrations, dozens of L3 atmosphere products are surveyed for changes caused by the corrections, and representative results are presented. Aerosol and water vapor products show only small local changes, while some cloud products can change locally by > 10%, which is a large change.

Calibration↗

SWIR Star Tracking

This work investigates the use of a star tracker that senses star light in the short wave infra-red wavelengths, specifically at the photometric H-band. The number of stars available for tracking and the corresponding photometric H-band magnitude is presented using information derived from the Two Micron All Sky Survey (2MASS) catalog. The probability of observing at least four stars in the star tracker’s field of view (FOV) at a given H-band magnitude or brighter is also presented. Finally, a notional short wave infra-red (SWIR) star tracker design is presented using the parameters calculated for the expected number of stars observed at the corresponding magnitudes in the photometric H-band. The results for the SWIR star tracker indicate the potential for a reduced FOV as compared to the visible wavelengths and relaxed star magnitude sensing requirements.

star tracking↗

Subsample Difference Correction for Terra MODIS SWIR Bands 5-7 Using Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the key instruments on board the Terra (EOS (Earth Observing Satellite) AM-1) spacecraft. MODIS has 36 spectral bands ranging in wavelength between 0.4 and 14.2 microns, at three spatial resolutions of 250 meters (bands 1-2), 500 meters (bands 3-7), and 1 kilometer (bands 8-36). For each 1-km sample, the 250-m and 500-m bands use 4 and 2 detectors with each acquiring 4 and 2 subsamples respectively in order to maintain consistent along-scan and along-track resolutions at nadir. The SWIR (Short-Wave Infrared) bands, 57 and 26, share the same focal-plane array as the 1-km thermal emissive bands, 20-25. During one of the two 500-m subsamples for bands 57, sampling of the 1-km bands introduces increased electronic crosstalk contamination, resulting in a subsample difference for both Earth-view and on-board calibrator observations. For this work, we use data from lunar and on-board blackbody observations, which occur at different signal levels for bands 20-25, to derive a correction to the contamination. This correction can be applied to reduce the subsample differences in the MODIS Earth-view data over a wide range of scenes. The impact of this correction on the sensor calibration and Earth-view data will be assessed.

SWIR↗

A relative radiometric correction method for airborne SWIR hyperspectral image using the side-slither technique

Stripe noise still remains in airborne short-wave infrared (SWIR) hyperspectral (HS) images after laboratory calibration due to the stray light of HS imager, nonlinear response of infrared focal plane array, and the distinct difference of equivalent color temperature between the integrating sphere and the sun. It is difficult to get a sun-like radiation source, and we apply the side-slither technique for relative radiometric correction of HS images. The calibration data corresponding to different irradiance were obtained by the side-slither technique of imager. Then, the two-point multi-section method is used for relative radiometric correction of HS images. This paper presents the principle, the experimental results, and the analysis of the proposed method. To validate the effectiveness of this method, it was compared with other methods and evaluated by quantitative quality indices. The results reveal that this method has a good performance in relative radiometric correction of HS image and is superior to the laboratory calibration based on integrating sphere. Consequently, the proposed method can successfully eliminate the adverse effect caused by the difference of equivalent color temperature between radiation sources, and also can improve the accuracy of HS applications such as absolute radiation correction and target recognition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlation of SWIR imaging with LPBF 304L stainless steel part properties

In the Laser Powder Bed Fusion (LPBF) process, the local thermal history can vary significantly over a part as the heat transfer characteristics and the laser scan path are geometry dependent. The variations introduce the potential for defects that lead to part failure, some of which are difficult to identify non-destructively with common ex-situ evaluation techniques. These defects include significant microstructural and mechanical property differences in the part interiors. In this paper, thermal features are extracted from in-situ Short-Wave Infrared (SWIR) imaging measurements to compile voxel based part representations and understand how the complexities in the thermal history affect part performance. The deviations in thermal features due to different laser processing parameters and complex scan pathing are explored. Empirical correlations are developed to map thermal features with the engineering properties (bulk yield strength, area percentage porosity, and local state) of 304L stainless steel parts manufactured by LPBF. Processing modes (insufficient melting and keyholing) are determined by mapping part property measurements with multiple thermal features. Generating the relationships between thermographic measurements and resulting SLM part properties lays the foundation for in-situ part qualification.

36 MATERIALS SCIENCE↗

Bias corrections of GOSAT SWIR XCO 2 and XCH 4 with TCCON data and their evaluation using aircraft measurement data

We describe a method for removing systematic biases of column-averaged dry air mole fractions of CO 2 (XCO 2 ) and CH 4 (XCH 4 ) derived from short-wavelength infrared (SWIR) spectra of the Greenhouse gases Observing SATellite (GOSAT). We conduct correlation analyses between the GOSAT biases and simultaneously retrieved auxiliary parameters. We use these correlations to bias correct the GOSAT data, removing these spurious correlations. Data from the Total Carbon Column Observing Network (TCCON) were used as reference values for this regression analysis. To evaluate the effectiveness of this correction method, the uncorrected/corrected GOSAT data were compared to independent XCO 2 and XCH 4 data derived from aircraft measurements taken for the Comprehensive Observation Network for TRace gases by AIrLiner (CONTRAIL) project, the National Oceanic and Atmospheric Administration (NOAA), the US Department of Energy (DOE), the National Institute for Environmental Studies (NIES), the Japan Meteorological Agency (JMA), the HIAPER Pole-to-Pole observations (HIPPO) program, and the GOSAT validation aircraft observation campaign over Japan. These comparisons demonstrate that the empirically derived bias correction improves the agreement between GOSAT XCO 2 /XCH 4 and the aircraft data. Finally, we present spatial distributions and temporal variations of the derived GOSAT biases.

54 ENVIRONMENTAL SCIENCES↗

Nanoengineered Materials for SWIR HOT Detectors

Heavy metal Selenide has been investigated for more than half century for high operating temperature (HOT) mid wave infrared (MWIR) applications. Most of the efforts have been devoted to make detector arrays on high-resistivity Si substrates for operating wavelengths in the 1.5 to 5.0 m region using physical vapor transport grown poly crystalline materials. For most of the biological spectral and imaging applications, short wave infrared (SWIR) detectors have shown better performance. Recent growth materials have shown variation in morphology with slight change in growth conditions and hence variation in performance parameters such as bandgap, mobility and resistivity from sample to sample. We have performed growth and optical characterization of pure and doped PbS and PbSe and have determined bandgap using available theoretical models for different morphologies.

Singh, N. B.↗

Data Simulation Using VLIDORT and PCRTM and its Use for Radiometric Calibration of Hyperspectral UV-NIR-SWIR Sensors

Using the vector linearized discrete ordinate radiative transfer model (VLIDORT), a multiple-scattering multi-layer discrete ordinate scattering codes, coupled with a fast principal component (PC) radiative transfer model (PCRTM), we can simulate the radiation fields for hyperspectral UV-NIR-SWIR sensors from 250nm to 2500nm with a very high speed. Since the accurate gas absorptions, molecules and aerosol/cloud particle scatterings, and the surface reflectance have been considered in these simulations, these model data can be used for satellite or airborne sensor design, characterization, or end-to-end system level uncertainty assessment. Comparison of the modelled data with measured results has been a general practice for operational satellite sensor calibrations, such as the Ozone Mapping and Profiler Suite (OMPS) onboard on SNPP and NOAA-20. This presentation will give more details of this simulation system and models. Some examples of the generation of simulations data for CLARREO PathFinder (CPF) and the Surface Biology and Geology (SBG), as well as some examples to use these data for CPF and OMPS radiometric calibration will be presented.

Xiaozhen Xiong↗

Counter Unmanned Aerial Systems Testing: Evaluation of VIS SWIR MWIR and LWIR passive imagers.

This report contains analysis of unmanned aerial systems as imaged by visible, short-wave infrared, mid-wave infrared, and long-wave infrared passive devices. Testing was conducted at the Nevada National Security Site (NNSS) during the week of August 15, 2016. Target images in all spectral bands are shown and contrast versus background is reported. Calculations are performed to determine estimated pixels-on-target for detection and assessment levels, and the number of pixels needed to cover a hemisphere for detection or assessment at defined distances. Background clutter challenges are qualitatively discussed for different spectral bands, and low contrast scenarios are highlighted for long-wave infrared imagers.

47 OTHER INSTRUMENTATION↗

A case for inherent geometric and geodetic accuracy in remotely sensed VNIR and SWIR imaging products

Significant aberrations can occur in acquired images which, unless compensated on board the spacecraft, can seriously impair throughput and timeliness for typical Earth observation missions. Conceptual compensations options are advanced to enable acquisition of images with inherent geometric and geodetic accuracy. Research needs are identified which, when implemented, can provide inherently accurate images. Agressive pursuit of these research needs is recommended.

Driver, J. M.↗

High density Schottky barrier IRCCD sensors for SWIR applications at intermediate temperature

Monolithic 32 x 64 and 64 x 1:128 palladium silicide (Pd2Si) interline transfer infrared charge coupled devices (IRCCDs) sensitive in the 1 to 3.5 micron spectral band were developed. This silicon imager exhibits a low response nonuniformity of typically 0.2 to 1.6% rms, and was operated in the temperature range between 40 to 140 K. Spectral response measurements of test Pd2Si p-type Si devices yield quantum efficiencies of 7.9% at 1.25 microns, 5.6% at 1.65 microns 2.2% at 2.22 microns. Improvement in quantum efficiency is expected by optimizing the different structural parameters of the Pd2Si detectors. The spectral response of the Pd2Si detectors fit a modified Fowler emission model. The measured photo-electric barrier height for the Pd2Si detectors is 0.34 eV and the measured quantum efficiency coefficient, C1, is 19%/eV. The dark current level of Pd2Si Schottky barrier focal plane arrays (FPAs) is sufficiently low to enable operation at intermediate temperatures at TV frame rates. Typical dark current level measured at 120 K on the FPA is 2 nA/sq cm. The operating temperature of the Pd2Si FPA is compatible with passive cooler performance. In addition, high density Pd2Si Schottky barrier FPAs are manufactured with high yield and therefore represent an economical approach to short wavelength IR imaging. A Pd2Si Schottky barrier image sensor for push-broom multispectral imaging in the 1.25, 1.65, and 2.22 micron bands is being studied. The sensor will have two line arrays (dual band capability) of 512 detectors each, with 30 micron center-to-center detector spacing. The device will be suitable for chip-to-chip abutment, thus providing the capability to produce large, multiple chip focal planes with contiguous, in-line sensors.

Elabd, H.↗