Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrophasor measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Pattern Mining and Anomaly Detection based on the Power System Synchrophasor Measurements

Real-time monitoring of power system dynamics using phasor measurement units (PMUs) data improves situational awareness and system reliability and potentially can help prevent blackouts due to early anomaly detection. The study presented in the paper is based on the actual PMU measurements of the U.S. western interconnection system. Given the nonlinear and nonstationary PMUs data, we developed a robust anomaly detection framework. Wavelet-based multi-resolution analysis, combined with moving-window-based outlier detection and anomaly scoring, were deployed to identify potential PMU events. The candidate events were evaluated using spatiotemporal correlation analysis, and then classified for a better understanding of the event types. The results demonstrated successful anomaly detection and classification, compared with the recorded real-world events.

Ren, Huiying↗

Synchrophasor measurement method for power systems

A synchrophasor measurement method for a device configured to take synchronized measurements in a power system is provided. The synchrophasor measurement method includes receiving global positioning system (GPS)-synchronized samples of a signal sensed by the device from the power system; determining a level of distortion of the signal; selecting, based on the level of distortion, a computation method, the computation method being one of an improved zero-crossing (IZC) method and an enhanced phase-lock-loop (EPLL) method; performing the selected computation method to determine at least one parameter of the signal at a reporting frequency, which is at least twice a line frequency of the power system; and outputting, at the reporting frequency, the at least one parameter to an operator of the power system to allow the operator to perform at least one of a monitoring and a controlling of at least one element of the power system.

Yao, Wenxuan↗

Ambient Synchrophasor Measurement Based System Inertia Estimation

This paper develops an algorithm to estimate the system inertia value based on ambient synchrophasor measurement. Informative features are extracted from ambient synchrophasor measurements for machine-learning-based inertia estimation. Besides ambient synchrophasor measurements of FNET/GridEye, other available data relevant to inertia (such as weather and system load data) are also used to improve the inertia estimation accuracy. Then a machine learning algorithm to estimate system inertia is developed. A test dataset including ambient synchrophasor data from FNET/GridEye measurements and the WECC system inertia data from NERC is used to evaluate the performance of the developed inertia estimation method. The average and maximum estimation errors of the developed inertia estimation method is lower than 5% and 10%, respectively. This accuracy is higher than reported accuracy values in existing literature.

CUI, YI↗

Data source authentication of synchrophasor measurement devices based on 1D-CNN and GRU

Synchrophasor measurement devices (SMDs) have been widely deployed to support real-time monitoring and control of power systems. In the meantime, data spoofing has emerged in recent years. Therefore, it is of great importance to study data authentication algorithms for detecting and defending the data spoofing effectively. Here, a one-dimensional convolutional neural network (1D-CNN) is utilized to extract temporal signatures hidden in frequency, voltage angle and amplitude data; then the gated recurrent unit (GRU) employs these temporal signatures for data source authentication. In case studies, the performances of different algorithms are tested in large-scale power systems with numerous SMDs for the first time, and comparisons among different algorithms show that the proposed algorithm can achieve a higher accuracy of data source authentication with a shorter time window.

47 OTHER INSTRUMENTATION↗

Power system observability and dynamic state estimation for stability monitoring using synchrophasor measurements

Growing penetration of intermittent resources such as renewable generations increases the risk of instability in a power grid. This paper introduces the concept of observability and its computational algorithms for a power grid monitored by the wide-area measurement system (WAMS) based on synchrophasors, e.g. phasor measurement units (PMUs). The goal is to estimate real-time states of generators, especially for potentially unstable trajectories, the information that is critical for the detection of rotor angle instability of the grid. The paper studies the number and siting of synchrophasors in a power grid so that the state of the system can be accurately estimated in the presence of instability. An unscented Kalman filter (UKF) is adopted as a tool to estimate the dynamic states that are not directly measured by synchrophasors. The theory and its computational algorithms are illustrated in detail by using a 9-bus 3-generator power system model and then tested on a 140-bus 48-generator Northeast Power Coordinating Council power grid model. Case studies on those two systems demonstrate the performance of the proposed approach using a limited number of synchrophasors for dynamic state estimation for stability assessment and its robustness against moderate inaccuracies in model parameters.

Observability, Dynamic state estimation, Synchroph↗

Supporting Cyber Security of Power Distribution Systems by Detecting Differences Between Real-time Micro-Synchrophasor Measurements and Cyber-Reported SCADA (Final Report)

As modern power grids tend towards greater levels of automation and communication, the challenges of identifying and mitigating vulnerabilities to cyber-attacks are ones that are increasingly demanding attention. Today’s power system has evolved to form the foundational bedrock of modern society, and an attack on this infrastructure could prove disastrous. In this project we were tasked to investigate the use of distribution synchrophasors as an independent isolated sensor network with which we can corroborate, or flag potentially spoofed,Supervisory Control And Data Acquisition (SCADA) data. We adapted an approach to marry the underlying physical properties of power systems with the network communications used by power systems in order to offer insights unattainable by either data stream isolation. While the concept of intrusion detection systems (IDS) is well understood for monitoring network traffic and traditional IT computing systems, the approach discussed in this report is motivated by several key notions: first, current SCADA communications alone presents an incomplete view of the grid. Second, the power grid, and the equipment controlling it, is grounded by laws of physics. Given this, we leverage high-frequency physical grid measurements to understand the physical condition of the grid, and combine this with SCADA. While high-frequency physical grid measurements and SCADA communication over Internet Protocol (IP) networks are fundamentally disparate information sources, when collectively examined through appropriate lenses, they offer a much more nuanced depiction of the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Anomaly Detection Using Machine Learning and HPC for Power System Synchrophasor Measurements

This paper presents an online early anomaly detection framework for phasor measurement units (PMUs) to monitor the power system dynamics and help prevent blackouts using machine learning approaches. Dynamical machine learning solutions including state space model and Kalman filter are conducted in this study to learn the nonlinear and nonstationary PMU measurements and accurately predict system behaviors in real-time. The anomalies can be detected within seconds by comparing the predicted system behaviors with the real system observations. The method proposed in this framework trains PMU data with a given time window (e.g., 5 seconds) using a dynamic nonlinear model, and then predicts system behaviors during the following time window. High prediction accuracy is achieved by applying the dynamic nonlinear model to the real-world PMU measurements – the anomalies detected are successfully validated given the recorded real-world events. High-performance-computing (HPC) techniques are utilized to further reduce computational time to provide real time power system situational awareness.

Ren, Huiying↗

Synchrophasor Measurement-Based Wind Plant Inertia Estimation: Preprint

The total inertia stored in all rotating masses that are connected to power systems, such as synchronous generations and induction motors, is an essential force that keeps the system stable after disturbances. To ensure bulk power system stability, there is a need to estimate the equivalent inertia available from a renewable generation plant. An equivalent inertia constant analogous to that of conventional rotating machines can be used to provide a readily understandable metric. This paper explores a method that utilizes synchrophasor measurements to estimate the equivalent inertia that a wind plant provides to the system.

17 WIND ENERGY↗

Measurement Accuracy Limitation Analysis on Synchrophasors

This paper analyzes the theoretical accuracy limitation of synchrophasors measurements on phase angle and frequency of the power grid. Factors that cause the measurement error are analyzed, including error sources in the instruments and in the power grid signal. Different scenarios of these factors are evaluated according to the normal operation status of power grid measurement. Based on the evaluation and simulation, the errors of phase angle and frequency caused by each factor are calculated and discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spatial-Temporal Synchrophasor Data Characterization and Analytics in Smart Grid Fault Detection, Identification, and Impact Causal Analysis

An approach of big data characterization for smart grids (SGs) and its applications in fault detection, identification, and causal impact analysis is proposed in this paper, which aims to provide substantial data volume reduction while keeping comprehensive information from synchrophasor measurements in spatial and temporal domains. Especially, based on secondary voltage control (SVC) and local SG observation algorithm, a two-layer dynamic optimal synchrophasor measurement devices selection algorithm (OSMDSA) is proposed to determine SVC zones, their corresponding pilot buses, and the optimal synchrophasor measurement devices. Combining the two-layer dynamic OSMDSA and matching pursuit decomposition, the synchrophasor data is completely characterized in the spatial-temporal domain. To demonstrate the effectiveness of the proposed characterization approach, SG situational awareness is investigated based on hidden Markov model based fault detection and identification using the spatial-temporal characteristics generated from the reduced data. To identify the major impact buses, the weighted Granger causality for SGs is proposed to investigate the causal relationship of buses during system disturbance. The IEEE 39-bus system and IEEE 118-bus system are employed to validate and evaluate the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Measurement Error on Synchrophasor Applications

Phasor measurement units (PMUs), a type of synchrophasor, are powerful diagnostic tools that can help avert catastrophic failures in the power grid. Because of this, PMU measurement errors are particularly worrisome. This report examines the internal and external factors contributing to PMU phase angle and frequency measurement errors and gives a reasonable explanation for them. It also analyzes the impact of those measurement errors on several synchrophasor applications: event location detection, oscillation detection, islanding detection, and dynamic line rating. The primary finding is that dynamic line rating is more likely to be influenced by measurement error. Other findings include the possibility of reporting nonoscillatory activity as an oscillation as the result of error, failing to detect oscillations submerged by error, and the unlikely impact of error on event location and islanding detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗