Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron X-ray microbeam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Strain partition and rupture analysis of notched tensile multilayered steel specimens

Highlights: • In situ SEM tensile experiments were performed to investigate the fracture processes. • In situ synchrotron x-ray diffraction were carried out to study the microscopic deformation in MLS steel. • The changing trends of the strain in the austenite layer and martensitic layer have been revealed. - Abstract: Multilayered steel composites consisting of alternating martensitic and austenite layers were successfully fabricated with a combination of high strength and ductility. In situ SEM tensile experiments were performed to investigate the fracture processes. Results indicated that the martensitic layer distributed between two ductile austenite layers has better deformation ability, and the dimple fracture mode dominated the fracture of the whole specimen. In situ synchrotron microbeam X-ray diffraction experiments were carried out to study the microscopic deformation in austenitic layer and martensitic layer ahead of notch root under incremental tensile loading. Results indicated that for austenite layer, the maximum strain is located in the middle of the layer at the lower applied load. When at the higher applied load, larger strain is concentrated on the notch root. For martensitic layer, uniform strain is distributed at the region at the lower applied load, with increasing the applied load, small strain appears in the middle of martensitic layer. However, the variation in the strain in the martensitic layer is relatively smaller, which is actually affected by both the notch and the ferrite content in the martensitic layer. The changing trends of the strain in the austenite layer and martensitic layer can still show the better combination of brittle martensitic phase and ductile austenite phase.

36 MATERIALS SCIENCE↗

Intragranular twinning, detwinning, and twinning-like lattice reorientation in magnesium alloys

We present that deformation twinning plays a critical role on improving metals or alloys ductility, especially for hexagonal close-packed materials with low symmetry crystal structure. A rolled Mg alloy was selected as a model system to investigate the extension twinning behaviors and characteristics of parent-twin interactions by nondestructive in situ 3D synchrotron X-ray microbeam diffraction. Besides twinning- detwinning process, the twinning-like lattice reorientation process was captured within an individual grain inside a bulk material during the strain reversal. The distributions of parent, twin, and reorientated grains and sub-micron level strain variation across the twin boundary are revealed. A theoretical calculation of the lattice strain confirms that the internal strain distribution in parent and twinned grains correlates with the experimental setup, grain orientation of parent, twin, and surrounding grains, as well as the strain path changes. In conclusion, the study suggests a novel deformation mechanism within the hexagonal close-packed structure that cannot be determined from surface-based characterization methods.

36 MATERIALS SCIENCE↗

Gas-mediated trace element incorporation into rhyolite-hosted topaz: A synchrotron microbeam XAS study

Magmatic gas exsolving during late-stage cooling of shallow magmas has been considered an important facilitator of low-pressure alteration and metal transport. However, the chemical properties of such gas, particularly its metal transport mechanisms and capacity, remain elusive. Trace elements in minerals produced by gas-mediated surface reaction or precipitation from gas capture details of gas composition and reaction pathways. However, interpretation of mineral trace element contents is dependent on understanding crystallographic controls on gas/mineral partitioning. Here, this work investigates the structural accommodation of As, Mn, Ga, Ge, Fe, and Ti in vapor-deposited topaz of vesicular topaz rhyolite from the Thomas Range, Utah, through single-crystal synchrotron microbeam X-ray techniques on picogram quantities of those trace elements. X-ray absorption near edge structure (XANES) data indicates that these elements are incorporated into topaz as As 5+ , Fe 3+ , Mn 3+ , Ti 4+ , Ga 3+ , and Ge 4+ . Extended X-ray absorption fine structure (EXAFS) analysis for these trace elements, compared to EXAFS of structural Al and Si, reveals that As 5+ and Ge 4+ are incorporated directly into the tetrahedral site of the topaz structure, with the octahedral site accommodating Mn 3+ , Fe 3+ , Ga 3+ , and Ti 4+ . For As 5+ and Fe 3+ , the structural impact of substitution extends to at least second neighbors (other elements were only resolvable to first neighbors). Further interpretation of the EXAFS results suggests that the substitution of Ti 4+ results in increased distortion of the octahedral site, while the other trace elements induce more uniform expansion correlating in magnitude to their ionic radius. Comparison of quantified X-ray fluorescence (XRF) data for two topaz crystals from this rhyolite reveals variable trace element concentrations for As 5+ , Fe 3+ , Ga 3+ , and Ti 4+ , reflective of a source gas undersaturated in these trace elements changing in concentration over the period of topaz deposition. The identical Ge 4+ content of the two topaz crystals suggests that Ge 4+ in the gas was buffered by the growth of another Ge 4+ -bearing phase, such as quartz. The very low Mn 3+ content in the topaz crystals does not reflect the abundance of Mn 3+ in the gas (saturation of Mn is evidenced by coexisting bixbyite). Instead, it suggests a strong Jahn-Teller inhibitory effect to the substitution of Mn 3+ for Al 3+ in the distorted octahedral site of topaz. It is proposed that exsolution of an HF-enriched gas from cooling rhyolitic magma led to local scouring of Al, Si, and trace metals from the magma. Once topaz crystals nucleated, self-catalyzed reactions that recycle HF led to continued growth of topaz.

36 MATERIALS SCIENCE↗

Basis for the Bauschinger effect in copper single crystals: changes in the long-range internal stress with reverse deformation

In this study, the long-range internal stresses (LRIS) associated with the Bauschinger effect were investigated using synchrotron X-ray microbeam diffraction and reversed deformation experiments. [100]-oriented Cu single crystals were deformed in compression to approximately -0.3 true strain, followed by tension to a strain of approximately +0.02. Two conclusions are arrived at from this work: First, the LRIS are confirmed in this work to be small relative to the applied stress both before and after reversal. Second, the LRIS persist after 2% reversed strain despite a significant drop in the overall dislocation density by dynamic recovery. This appears to satisfy the necessary condition for LRIS to significantly contribute to a Bauschinger effect in materials. Lastly, the pronounced Bauschinger effect in Cu is probably best rationalized by a combination of both the LRIS and the Orowan–Sleeswyk model that relies on a non-uniform distribution of dislocation obstacles without a substantial LRIS.

36 MATERIALS SCIENCE↗

Interaction between Al and atomic layer deposited (ALD) ZrN under high-energy heavy ion irradiation

Uranium-molybdenum (U-Mo) particles dispersed in an aluminum matrix is the most promising candidate fuel to convert high-power research and test reactors in Europe from using high-enriched to using low-enriched fuel. However, chemical interaction between the U-Mo and the Al matrix leads to undesirable fuel behavior. Zirconium nitride (ZrN) is used as a diffusion barrier between the U-Mo fuel particles and the Al matrix. To understand the potential microstructural evolution of ZrN during irradiation, a high-energy heavy ion (84 MeV Xe) irradiation experiment was performed on atomic layer deposited (ALD) nanocrystalline ZrN deposited on an Al plate. A fluence of 1.86 x 10 17 ions/cm 2 , or 90.3 dpa was reached during this experiment. Both analytic transmission electron microscopy (TEM) and synchrotron microbeam X-ray diffraction (ARD) techniques were utilized to investigate the kinetics of radiation-induced grain growth of ZrN at various radiation doses based on the Williamson-Hall analyses. The grain growth kinetics can be described by a power law expression, D n - D$n\atop{0}$ = K phi, with n = 5.1. The Al-ZrN interaction products (Al 3 Zr and AIN) created by radiation-induced ballistic mixing/radiation-enhanced diffusion and their corresponding formation mechanism were determined from electron diffraction and elemental composition analysis. These experimental results were confirmed by first principle thermodynamic density functional theory (DFT) calculations. The results from this ion irradiation study were also compared to in-pile irradiation data from physical vapor deposited (PVD) ZrN samples for a comprehensive evaluation of the interaction between Al and ZrN and its influence on diffusion barrier performance.

36 MATERIALS SCIENCE↗

High-throughput investigation of crystal-to-glass transformation of Ti–Ni–Cu ternary alloy

A high-throughput investigation of metallic glass formation via solid-state reaction was reported in this paper. Combinatorial multilayered thin-film chips covering the entire Ti-Ni-Cu ternary system were prepared using ion beam sputtering technique. Microbeam synchrotron X-ray diffraction (XRD) and X-ray fluorescence (XRF) measurements were conducted, with 1,325 data points collected from each chip, to map out the composition and the phase constitution before and after annealing at 373 K for 110 hours. The composition dependence of the crystal-to-glass transition by solid-state reaction was surveyed using this approach. The resulting composition-phase map is consistent with previously reported results. Time-of-flight secondary ion mass spectroscopy (ToF-SIMS) was performed on the representative compositions to determine the inter-diffusion between layers, the result shows that the diffusion of Ti is the key factor for the crystal-to-glass transition. In addition, both layer thickness and layer sequence play important roles as well. This work demonstrates that combinatorial chip technique is an efficient way for systematic and rapid study of crystal-to-glass transition for multi-component alloy systems.

36 MATERIALS SCIENCE↗

Lifetimes and spatio-temporal response of protein crystals in intense X-ray microbeams

Serial synchrotron-based crystallography using intense microfocused X-ray beams, fast-framing detectors and protein microcrystals held at 300 K promises to expand the range of accessible structural targets and to increase overall structure-pipeline throughputs. To explore the nature and consequences of X-ray radiation damage under microbeam illumination, the time-, dose- and temperature-dependent evolution of crystal diffraction have been measured with maximum dose rates of 50 MGy s −1 . At all temperatures and dose rates, the integrated diffraction intensity for a fixed crystal orientation shows non-exponential decays with dose. Non-exponential decays are a consequence of non-uniform illumination and the resulting spatial evolution of diffracted intensity within the illuminated crystal volume. To quantify radiation-damage lifetimes and the damage state of diffracting crystal regions, a revised diffraction-weighted dose (DWD) is defined and it is shown that for Gaussian beams the DWD becomes nearly independent of actual dose at large doses. An apparent delayed onset of radiation damage seen in some intensity–dose curves is in fact a consequence of damage. Intensity fluctuations at high dose rates may arise from the impulsive release of gaseous damage products. Accounting for these effects, data collection at the highest dose rates increases crystal radiation lifetimes near 300 K (but not at 100 K) by a factor of ∼1.5–2 compared with those observed at conventional dose rates. Improved quantification and modeling of the complex spatio-temporal evolution of protein microcrystal diffraction in intense microbeams will enable more efficient data collection, and will be essential in improving the accuracy of structure factors and structural models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synchrotron Microbeam Diffraction Studies on the Alignment within 3D-Printed Smectic-A Liquid Crystal Elastomer Filaments during Extrusion

3D printing of novel and smart materials has received considerable attention due to its applications within biological and medical fields, mostly as they can be used to print complex architectures and particular designs. However, the internal structure during 3D printing can be problematic to resolve. We present here how time-resolved synchrotron microbeam Small-Angle X-ray Diffraction (μ-SAXD) allows us to elucidate the local orientational structure of a liquid crystal elastomer-based printed scaffold. Most reported 3D-printed liquid crystal elastomers are mainly nematic; here, we present a Smectic-A 3D-printed liquid crystal elastomer that has previously been reported to promote cell proliferation and alignment. The data obtained on the 3D-printed filaments will provide insights into the internal structure of the liquid crystal elastomer for the future fabrication of liquid crystal elastomers as responsive and anisotropic 3D cell scaffolds.

36 MATERIALS SCIENCE↗

Micro-imaging of Brain Cancer Radiation Therapy Using Phase-contrast Computed Tomography

Experimental neuroimaging provides a wide range of methods for the visualization of brain anatomic morphology down to subcellular detail. Still, each technique-specific detection mechanism presents compromises among the achievable field-of-view size, spatial resolution, and nervous tissue sensitivity, leading to partial sample coverage, unresolved morphologic structures, or sparse labeling of neuronal populations and often also to obligatory sample dissection or other sample invasive manipulations. X-ray phase-contrast imaging computed tomography (PCI-CT) is an experimental imaging method that simultaneously provides micrometric spatial resolution, high soft-tissue sensitivity, and ex vivo full organ rodent brain coverage without any need for sample dissection, staining or labeling, or contrast agent injection. In the present study, we explored the benefits and limitations of PCI-CT use for in vitro imaging of normal and cancerous brain neuromorphology after in vivo treatment with synchrotron-generated x-ray microbeam radiation therapy (MRT), a spatially fractionated experimental high-dose radiosurgery. The goals were visualization of the MRT effects on nervous tissue and a qualitative comparison of the results to the histologic and high-field magnetic resonance imaging findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cementum structure in Beluga whale teeth

We report that a large fraction of the volume of Beluga whale (Delphinapterus leucas) teeth consists of cementum, a mineralized tissue which grows throughout the life of the animal and to which the periodontal ligaments attach. Annular growth bands or growth layer groups (GLGs) form within Beluga cementum, and this study investigates GLG structure using X-ray fluorescence mapping and X-ray diffraction mapping with microbeams of synchrotron radiation. The Ca and Zn fluorescent intensities and carbonated hydroxyapatite (cAp) diffracted intensities rise and fall together and match the light-dark bands visible in transmitted light micrographs. Within the bands of maximum Ca and Zn intensity, the ratio of Zn to Ca is slightly higher than in the minima bands. Further, the GLG cAp, Ca and Zn modulation is preserved throughout the cementum for durations >25 year.

36 MATERIALS SCIENCE↗

In Situ Synchrotron X-ray Micro-Diffraction Investigation of Elastic Strains in Laminated Ti-Al Composites

Spatially resolved elastic strains in the bulk interior of a laminated Ti-Al metal composite were studied during in situ tensile loading at strains up to 1.66% by a synchrotron-based micro-diffraction technique, namely differential aperture X-ray microscopy (DAXM). For both Al and Ti grains, deviatoric elastic strains were estimated based on polychromatic X-ray microbeam diffraction, while lattice strains along the normal direction of the tensile sample were directly measured using monochromatic X-ray microbeam diffraction. The estimated deviatoric strains show large spatial variations, and the mean values are consistent with the external loading conditions, i.e., increasing tensile strain along the tensile direction and increasing compressive strain along the sample normal with increasing loading. The directly measured lattice strains also show large spatial variations, although the magnitude of this variation is smaller than that for the estimated deviatoric strain. The directly measured lattice strains in Ti grains are largely consistent with the external loading, whereas those in Al grains are in contradiction with the external loading. The causes of the experimental results are discussed and related to both the laminated microstructure of the composite material and the limitations of the techniques.

36 MATERIALS SCIENCE↗

Synchrotron X-Ray Diffraction Studies of Olivine from Comet Wild 2

We have analyzed a collection of the Comet Wild 2 coma grains returned by the NASA Stardust Mission, using micro-area Laue diffraction equipment. The purpose of the diffraction experiment is to permit the structure refinement of olivine including site occupancies. In addition to the intrinsic importance of the olivine structures for revealing the thermal history of Wild 2 materials, we wish to test reports that olivine recovered after hypervelocity capture in silica aerogel has undergone a basic structural change due to capture heating [1]. The diffraction equipment placed at beam line BL- 4B1 of PF, KEK was developed with a micropinhole and an imaging plate (Fuji Co. Ltd.) using the Laue method combined with polychromatic X-ray of synchrotron radiation operated at energy of 2.5 GeV. The incident beam is limited to 1.6 m in diameter by a micropinhole set just upstream of the sample [2, 3]. It is essential to apply a microbeam to obtain diffracted intensities with high signal to noise ratios. This equipment has been successfully applied to various extraterrestrial materials, including meteorites and interplanetary dust particles [4]. The Laue pattern of the sample C2067,1,111,4 (Fig. 1) was successfully taken on an imaging plate after a 120 minute exposure (Fig. 2).

Source record↗

Microbeam synchrotron radiation diffraction and fluorescence of oxide layers formed on zirconium alloys at different corrosion temperatures

Autoclave corrosion tests of Zircaloy-4 were performed at temperatures ranging from 274°C to 427 °C to determine how the characteristics of the oxide layer changed with corrosion temperature. Corroded samples were prepared in cross-section and examined at the Advanced Photon Source using x-ray diffraction and fluorescence with sub-micron spatial resolution. These measurements provide high fidelity data for characterization of the oxide layer grown on zirconium alloys over a range of temperatures to better understand the fundamental mechanisms of corrosion. It was found that the size of the monoclinic oxide grains increases with distance from the metal-oxide interface, while the average grain size of the tetragonal oxide phase decreases. This is consistent with the continuous nucleation of a mixture of equiaxed tetragonal and monoclinic grains at the metal-oxide interface, of which only the monoclinic oxide grains that are properly aligned to minimize stresses grow into long columnar oxide grains. The tetragonal phase oxide grains transform to monoclinic oxide once a critical size is reached. While the monoclinic oxide grain size increases with corrosion temperature, the tetragonal phase grain size remains below a maximum value. Evolution of the tetragonal fraction, calculated with the Garvie-Nicholson formula, was observed, with local maxima seen just before transition and local minima seen at oxide locations corresponding to the oxide kinetic transition. No difference was observed in the tetragonal phase fraction in the oxide layers formed at different corrosion temperatures. Detailed fluorescence and diffraction mapping of one sample showed the evolution of the diffraction intensity over a short range in the oxide. In conclusion, this work provides a systematic study revealing fundamental characteristics of the microstructure of Zircaloy-4 oxide layers to further understanding of corrosion resistance of these materials.

36 MATERIALS SCIENCE↗

Refinements for Bragg coherent X-ray diffraction imaging: electron backscatter diffraction alignment and strain field computation

Bragg coherent X-ray diffraction imaging (BCDI) allows the 3D measurement of lattice strain along the scattering vector for specific microcrystals. If at least three linearly independent reflections are measured, the 3D variation of the full lattice strain tensor within the microcrystal can be recovered. However, this requires knowledge of the crystal orientation, which is typically attained via estimates based on crystal geometry or synchrotron microbeam Laue diffraction measurements. Presented here is an alternative method to determine the crystal orientation for BCDI measurements using electron backscatter diffraction (EBSD) to align Fe–Ni and Co–Fe alloy microcrystals on three different substrates. The orientation matrix is calculated from EBSD Euler angles and compared with the orientation determined using microbeam Laue diffraction. The average angular mismatch between the orientation matrices is less than ∼6°, which is reasonable for the search for Bragg reflections. The use of an orientation matrix derived from EBSD is demonstrated to align and measure five reflections for a single Fe–Ni microcrystal via multi-reflection BCDI. Using this data set, a refined strain field computation based on the gradient of the complex exponential of the phase is developed. This approach is shown to increase accuracy, especially in the presence of dislocations. The results demonstrate the feasibility of using EBSD to pre-align BCDI samples and the application of more efficient approaches to determine the full lattice strain tensor with greater accuracy.

42 ENGINEERING↗

An instrument for in situ coherent x-ray studies of metal-organic vapor phase epitaxy of III-nitrides

Here, we describe an instrument that exploits the ongoing revolution in synchrotron sources, optics, and detectors to enable in situ studies of metal-organic vapor phase epitaxy (MOVPE) growth of III-nitride materials using coherent x-ray methods. The system includes high-resolution positioning of the sample and detector including full rotations, an x-ray transparent chamber wall for incident and diffracted beam access over a wide angular range, and minimal thermal sample motion, giving the sub-micron positional stability and reproducibility needed for coherent x-ray studies. The instrument enables surface x-ray photon correlation spectroscopy, microbeam diffraction, and coherent diffraction imaging of atomic-scale surface and film structure and dynamics during growth, to provide fundamental understanding of MOVPE processes.

36 MATERIALS SCIENCE↗

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples

In this paper, we describe a detailed procedure for acquiring and processing x-ray microfluorescence (μXRF), and Laue and powder microdiffraction two-dimensional (2D) maps at beamline 12.3.2 of the Advanced Light Source (ALS), Lawrence Berkeley National Laboratory. Measurements can be performed on any sample that is less than 10 cm x 10 cm x 5 cm, with a flat exposed surface. The experimental geometry is calibrated using standard materials (elemental standards for XRF, and crystalline samples such as Si, quartz, or Al 2 O 3 for diffraction). Samples are aligned to the focal point of the x-ray microbeam, and raster scans are performed, where each pixel of a map corresponds to one measurement, e.g. , one XRF spectrum or one diffraction pattern. The data are then processed using the in-house developed software XMAS, which outputs text files, where each row corresponds to a pixel position. Representative data from moissanite and an olive snail shell are presented to demonstrate data quality, collection, and analysis strategies.

36 MATERIALS SCIENCE↗

Bragg Spot Finder (BSF): a new machine-learning-aided approach to deal with spot finding for rapidly filtering diffraction pattern images

Macromolecular crystallography contributes significantly to understanding diseases and, more importantly, how to treat them by providing atomic resolution 3D structures of proteins. This is achieved by collecting X-ray diffraction images of protein crystals from important biological pathways. Spotfinders are used to detect the presence of crystals with usable data, and the spots from such crystals are the primary data used to solve the relevant structures. Having fast and accurate spot finding is essential, but recent advances in synchrotron beamlines used to generate X-ray diffraction images have brought us to the limits of what the best existing spotfinders can do. This bottleneck must be removed so spotfinder software can keep pace with the X-ray beamline hardware improvements and be able to see the weak or diffuse spots required to solve the most challenging problems encountered when working with diffraction images. In this paper, we first present Bragg Spot Detection (BSD), a large benchmark Bragg spot image dataset that contains 304 images with more than 66 000 spots. We then discuss the open source extensible U-Net-based spotfinder Bragg Spot Finder (BSF), with image pre-processing, a U-Net segmentation backbone, and post-processing that includes artifact removal and watershed segmentation. Finally, we perform experiments on the BSD benchmark and obtain results that are (in terms of accuracy) comparable to or better than those obtained with two popular spotfinder software packages ( Dozor and DIALS ), demonstrating that this is an appropriate framework to support future extensions and improvements.

36 MATERIALS SCIENCE↗