Search NASA⌕ Search

SEARCH · Search NASA

Results for “system description”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Galilei invariant technique for quantum system description

Problems with quantum systems models, violating Galilei invariance are examined. The method for arbitrary non-relativistic quantum system Galilei invariant wave function construction, applying a modified basis where center-of-mass excitations have been removed before Hamiltonian matrix diagonalization, is developed. For identical fermion system, the Galilei invariant wave function can be obtained while applying conventional antisymmetrization methods of wave functions, dependent on single particle spatial variables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Natural Gas Fugitive Leak Detection Using an Unmanned Aerial Vehicle: Measurement System Description and Mass Balance Approach

Natural gas is an abundant resource across the United States, of which methane (CH4) is the main component. About 2% of extracted CH4 is lost through leaks. The Remote Methane Leak Detector (RMLD)-Unmanned Aerial Vehicle (UAV) system was developed to investigate natural gas fugitive leaks in this study. The system is composed of three major technologies: miniaturized RMLD (mini-RMLD) based on Backscatter Tunable Diode Laser Absorption Spectroscopy (TDLAS), an autonomous quadrotor UAV and simplified quantification and localization algorithms. With a miniaturized, downward-facing RMLD on a small UAV, the system measures the column-integrated CH4 mixing ratio and can semi-autonomously monitor CH4 leakage from sites associated with natural gas production, providing an advanced capability in detecting leaks at hard-to-access sites compared to traditional manual methods. Automated leak characterization algorithms combined with a wireless data link implement real-time leak quantification and reporting. This study placed particular emphasis on the RMLD-UAV system description and the quantification algorithm development based on a mass balance approach. Early data were gathered to test the prototype system and to evaluate the algorithm performance. The quantification algorithm derived in this study tended to underestimate the gas leak rates and yielded unreliable estimations in detecting leaks under 7 × 10 − 6 m3/s (~1 Standard Cubic Feet per Hour (SCFH)). Zero-leak cases can be ascertained via a skewness indicator, which is unique and promising. The influence of the systematic error was investigated by introducing simulated noises, of which Global Positioning System (GPS) noise presented the greatest impact on leak rate errors. The correlation between estimated leak rates and wind conditions were investigated, and steady winds with higher wind speeds were preferred to get better leak rate estimations, which was accurate to approximately 50% during several field trials. High precision coordinate information from the GPS, accurate wind measurements and preferred wind conditions, appropriate flight strategy and the relative steady survey height of the system are the crucial factors to optimize the leak rate estimations.

03 NATURAL GAS↗

Software-controlled, highly automated intrafraction prostate motion correction with intrafraction stereographic targeting: System description and clinical results

Purpose: A new system for software-controlled, highly automated correction of intrafraction prostate motion,'' intrafraction stereographic targeting'' (iSGT), is described and evaluated. Methods: At our institute, daily prostate positioning is routinely performed at the start of treatment beam using stereographic targeting (SGT). iSGT was implemented by extension of the SGT software to facilitate fast and accurate intrafraction motion corrections with minimal user interaction. iSGT entails megavoltage (MV) image acquisitions with the first segment of selected IMRT beams, automatic registration of implanted markers, followed by remote couch repositioning to correct for intrafraction motion above a predefined threshold, prior to delivery of the remaining segments. For a group of 120 patients, iSGT with corrections for two nearly lateral beams was evaluated in terms of workload and impact on effective intrafraction displacements in the sagittal plane. Results: SDs of systematic ({Sigma}) and random ({sigma}) displacements relative to the planning CT measured directly after initial SGT setup correction were <0.5 and <0.8 mm, respectively. Without iSGT corrections, effective {Sigma} and {sigma} for the 11-min treatments would increase to {Sigma}{sub eff} < 1.1 mm and {sigma}{sub eff} < 1.2 mm. With the iSGT procedure with an action level of 4 mm, effective positioning errors were reduced to {Sigma}{sub eff} < 0.8 mm and {sigma}{sub eff} < 1.0 mm, with 23.1% of all fractions requiring a correction. Computer simulations demonstrated that with an action level of 2 mm, the errors would have been reduced to {Sigma}{sub eff} < 0.6 mm and {sigma}{sub eff} < 0.7 mm, requiring corrections in 82.4% of the fractions. Because iSGT is highly automated, the extra time added by iSGT is <30 s if a correction is required. Conclusions: Without increasing imaging dose, iSGT successfully reduces intrafraction prostate motion with minimal workload and increase in fraction time. An action level of 2 mm is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SPRUCE Enclosure Corral and Sump System: Description, Operation, and Calibration

This document describes the subsurface corral system that has been designed and constructed to measure water flow and allow the collection of water samples from the outflow of each experimental enclosure at the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA. SPRUCE implemented 10 years of whole-ecosystem warming, deep peat heating, and elevated carbon dioxide (CO2) treatments from 2015-2025 to assess the response of northern peatland ecosystems to increases in temperature and exposures to elevated atmospheric CO2 concentrations. This document: 1. Describes belowground corrals, sump systems, and the operation of sump systems, which are used to calculate the volumes of water that naturally drain enclosures and to trigger automatic collection of water samples; 2. Describes the calibration between water level and water volume in the sump system. This relationship is used to calculate near-surface lateral runoff (“outflow” in L/s) from each enclosure by measuring the change in water level over time. The water volume vs. water level relationship must be re-calibrated if water level sensors (or components) are replaced; and 3. Describes the data and data products that are and will be available from outflow measurements.

54 ENVIRONMENTAL SCIENCES↗

An automatic and accurate x-ray tube focal spot/grid alignment system for mobile radiography: System description and alignment accuracy

Purpose: A mobile radiography automatic grid alignment system (AGAS) has been developed by modifying a commercially available mobile unit. The objectives of this article are to describe the modifications and operation and to report on the accuracy with which the focal spot is aligned to the grid and the time required to achieve the alignment. Methods: The modifications include an optical target arm attached to the grid tunnel, a video camera attached to the collimator, a motion control system with six degrees of freedom to position the collimator and x-ray tube, and a computer to control the system. The video camera and computer determine the grid position, and then the motion control system drives the x-ray focal spot to the center of the grid focal axis. The accuracy of the alignment of the focal spot with the grid and the time required to achieve alignment were measured both in laboratory tests and in clinical use. Results: For a typical exam, the modified unit automatically aligns the focal spot with the grid in less than 10 s, with an accuracy of better than 4 mm. The results of the speed and accuracy tests in clinical use were similar to the results in laboratory tests. Comparison patient chest images are presented--one obtained with a standard mobile radiographic unit without a grid and the other obtained with the modified unit and a 15:1 grid. The 15:1 grid images demonstrate a marked improvement in image quality compared to the nongrid images with no increase in patient dose. Conclusions: The mobile radiography AGAS produces images of significantly improved quality compared to nongrid images with alignment times of less than 10 s and no increase in patient dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Overall Reactor System Description of Prototype Gen-IV Sodium Cooled Fast Reactor

A fast reactor system has been recognized as one of the most promising options for transmutation of the radioactive wastes discharged from spent nuclear fuel of light water reactors (LWRs). That is owing to the intrinsic features of a fast reactor, i.e., high neutron energy and abundant excessive neutrons in the core. In this context, the Korea Atomic Energy Commission (KAEC) authorized the R and D action plan for the advanced sodium cooled fast reactor (SFR) connected with the pyro-process to provide a consistent direction to long-term R and D activities in December 2008. The long term plan was updated in November 2011 in order to refine the plan and to consider the available budget for SFR. The revised milestones include the completion of a specific design of a prototype Gen IV sodium cooled fast reactor (PGSFR) by 2017, specific design approval by 2020, and construction by 2028. The R and D activities on SFR had been concentrated on the basic and strategic key technology developments before 2012 and went to engineering project for licensing and construction of PGSFR from 2012. The development of PGSFR is now in the first design phase and will go toward to the second design phase in 2016. All the high level design concepts of systems, structures and components (SSCs) are determined and incorporated into the preliminary safety information document (PSID), which includes basic design requirements and descriptions and the results of safety analysis for the representative accident scenarios. The PSID will be a base material for a pre-review of the PGSFR safety. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The MERRA-2 Aerosol Reanalysis, 1980 Onward. Part I: System Description and Data Assimilation Evaluation

The Modern-Era Retrospective Analysis for Research and Applications, version 2 (MERRA-2), updates NASA’s previous satellite-era (1980 onward) reanalysis system to include additional observations and improvements to the Goddard Earth Observing System, version 5 (GEOS-5), Earth system model. As a major step toward a full Integrated Earth Systems Analysis (IESA), in addition to meteorological observations, MERRA-2 now includes assimilation of aerosol optical depth (AOD) from various ground- and space-based remote sensing platforms. Here, in the first of a pair of studies, the MERRA-2 aerosol assimilation is documented, including a description of the prognostic model (GEOS-5 coupled to the GOCART aerosol module), aerosol emissions, and the quality control of ingested observations. Initial validation and evaluation of the analyzed AOD fields are provided using independent observations from ground, aircraft, and shipborne instruments. The positive impact of the AOD assimilation on simulated aerosols is demonstrated by comparing MERRA-2 aerosol fields to an identical control simulation that does not include AOD assimilation. Fianlly, after showing the AOD evaluation, this paper takes a first look at aerosol–climate interactions by examining the shortwave, clear-sky aerosol direct radiative effect. The companion paper (Part II) evaluates and validates available MERRA-2 aerosol properties not directly impacted by the AOD assimilation (e.g., aerosol vertical distribution and absorption). Importantly, while highlighting the skill of the MERRA-2 aerosol assimilation products, both studies point out caveats that must be considered when using this new reanalysis product for future studies of aerosols and their interactions with weather and climate.

54 ENVIRONMENTAL SCIENCES↗

Integrated Safety Management System Description

Personnel at Sandia National Laboratories (hereinafter referred to as Sandia) comply with United States Department of Energy (DOE) Policy 450.4A, Chg 1, Integrated Safety Management Policy, and implement an Integrated Safety Management System (ISMS) to ensure safe operations. Safety is integrated into management and work practices at all levels so missions are accomplished while protecting Members of the Workforce, the public, and the environment. As a result, safety is effectively integrated into all facets of work planning and execution. Thus the management of safety functions becomes an integral part of mission accomplishment and meets the requirements outlined in the DOE Acquisition Regulation (DEAR) 970.5223-1, Integration of Environment, 4/.01, and Health into Work Planning and Execution, clause incorporated by reference into the Prime Contract.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Integrated Safety Management System Description, Revision 9, PG470252

Personnel at Sandia National Laboratories (hereinafter referred to as Sandia) comply with U.S. Department of Energy (DOE) P 450.4A, Chg 1, Integrated Safety Management Policy, and implement an Integrated Safety Management System (ISMS) to ensure safe operations. Sandia personnel integrate safety into management and work practices at all levels so that missions are accomplished while protecting Members of the Workforce, the public, and the environment. As a result, safety is effectively integrated into all facets of work planning and execution. Thus, the management of safety functions becomes an integral part of mission accomplishment and meets the requirements outlined in the DOE Acquisition Regulation (DEAR) 970.5223-1, Integration of Environment, Safety, and Health into Work Planning and Execution clause incorporated into the Prime Contract. The DEAR 970.5223-1, Integration of Environment, Safety, and Health into Work Planning and Execution clause requires DOE contractors to manage and perform work in accordance with a documented Safety Management System that fulfills conditions of the DEAR clause, at a minimum. For purposes of this clause, safety encompasses environment, safety, and health, including pollution prevention and waste minimization.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Integrated Safety Management System Description (PG470252) (V.10)

Personnel at Sandia National Laboratories (hereinafter referred to as Sandia) comply with United States Department of Energy (DOE) Policy 450.4A, Chg 1, Integrated Safety Management Policy, and implement an Integrated Safety Management System (ISMS) to ensure safe operations. Sandia personnel integrate safety into management and work practices at all levels so missions are accomplished while protecting Members of the Workforce, the public, and the environment. As a result, safety is effectively integrated into all facets of work planning and execution. Thus the management of safety functions becomes an integral part of mission accomplishment and meets the requirements outlined in the DOE Acquisition Regulation (DEAR) 970.5223-1, Integration of Environment, Safety, and Health into Work Planning and Execution, clause incorporated by reference into the Prime Contract. The DEAR 970.5223-1, Integration of Environment, Safety, and Health into Work Planning and Execution, clause requires DOE contractors to manage and perform work in accordance with a documented Safety Management System that fulfills conditions of the DEAR clause at a minimum. For purposes of this clause, safety encompasses environment, safety, and health (ES&H), including pollution prevention and waste minimization.

99 GENERAL AND MISCELLANEOUS↗

LAW Primary Offgas Process (LOP) and LAW Secondary Offgas/Vessel Vent Process (LVP) System Design Description

This system design description (SDD) defines the technical, functional, and performance requirements of the Low-Activity Waste (LAW) Facility primary offgas process system (LOP) and the LAW Facility secondary offgas/vessel vent process system (LVP). This document details waste treatment requirements, environmental compliance requirements, and authorization basis requirements of the LOP and LVP systems as they are currently known and understood.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Activity Waste Melter Process (LMP) System Design Description (Rev. 4)

This system design description (SDD) defines the technical, functional, and performance requirements of the low-activity waste (LAW) melter process system (LMP). This document details the waste treatment requirements, environmental compliance requirements, and authorization basis requirements of the LMP system as they are currently known and understood. This SDD describes the process and functional design requirements of the LMP, including the following: 1) Services and utility requirements, operating materials and supplies, and other external interfaces; 2) Operations limits and design bases; 3) Other criteria and requirements pertinent to the design of the LMP system; 4) Boundaries, system interfaces, and functional description of the LMP system. The LMP system is composed of two LAW melters of the same design with the contingency to add the third. Also included in the LMP system are the pour spouts, which are positioned under the melter discharge chambers of each melter, and the container level detectors. The boundaries, system interfaces, and functional description of the LMP system are provided in Section 2.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

System Design Description and Requirements for Modeling the Off-Gas Systems for Fuel Recycling Facilities

This document provides descriptions of the off-gases evolved during spent nuclear fuel processing and the systems used to capture the gases of concern. Two reprocessing techniques are discussed, namely aqueous separations and electrochemical (pyrochemical) processing. The unit operations associated with each process are described in enough detail so that computer models to mimic their behavior can be developed. The document also lists the general requirements for the desired computer models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗